Migration from Contrast Transfer Function to ISO Spatial Frequency Response

Similar documents
Parameters of Image Quality

Refined Slanted-Edge Measurement for Practical Camera and Scanner Testing

A Study of Slanted-Edge MTF Stability and Repeatability

Practical Scanner Tests Based on OECF and SFR Measurements

ISO INTERNATIONAL STANDARD. Photography Electronic scanners for photographic images Dynamic range measurements

Edge-Raggedness Evaluation Using Slanted-Edge Analysis

Sampling Efficiency in Digital Camera Performance Standards

Influence of Image Enhancement Processing on SFR of Digital Cameras

Defense Technical Information Center Compilation Part Notice

An Evaluation of MTF Determination Methods for 35mm Film Scanners

Diagnostics for Digital Capture using MTF

digital film technology Resolution Matters what's in a pattern white paper standing the test of time

Determination of the MTF of JPEG Compression Using the ISO Spatial Frequency Response Plug-in.

Evaluating Commercial Scanners for Astronomical Images. The underlying technology of the scanners: Pixel sizes:

Fingerprint Image Quality Parameters

ISO INTERNATIONAL STANDARD. Photography Electronic still-picture cameras Resolution measurements

Camera Resolution and Distortion: Advanced Edge Fitting

Image Evaluation and Analysis of Ink Jet Printing System (I) MTF Measurement and Analysis of Ink Jet Images

ISO INTERNATIONAL STANDARD. Photography Electronic scanners for photographic images Dynamic range measurements

MTF Analysis and its Measurements for Digital Still Camera

Fast MTF measurement of CMOS imagers using ISO slantededge methodology

Commercial Scanners and Science

Measuring MTF with wedges: pitfalls and best practices

Digital Imaging Performance Report for Indus International, Inc. October 27, by Don Williams Image Science Associates.

QUANTITATIVE IMAGE TREATMENT FOR PDI-TYPE QUALIFICATION OF VT INSPECTIONS

CCD Requirements for Digital Photography

Non Linear Image Enhancement

Resolution test with line patterns

SCANNING GUIDELINES Peter Thompson (rev. 9/21/02) OVERVIEW

Basic Scanning in Adobe Photoshop

DIGITAL IMAGING. Handbook of. Wiley VOL 1: IMAGE CAPTURE AND STORAGE. Editor-in- Chief

Digital Photography Standards

Visibility of Uncorrelated Image Noise

EBU - Tech 3335 : Methods of measuring the imaging performance of television cameras for the purposes of characterisation and setting

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

KODAK VISION Expression 500T Color Negative Film / 5284, 7284

Measurement of Texture Loss for JPEG 2000 Compression Peter D. Burns and Don Williams* Burns Digital Imaging and *Image Science Associates

Fotografi Skannrar för fotografiska bilder Mätning av det dynamiska området (ISO 21550:2005, IDT)

Optical Performance of Nikon F-Mount Lenses. Landon Carter May 11, Measurement and Instrumentation

Device Independent Color Who Wants It?

TIPA Camera Test. How we test a camera for TIPA

ISO/IEC TS TECHNICAL SPECIFICATION

White Paper Focusing more on the forest, and less on the trees

1. Redistributions of documents, or parts of documents, must retain the SWGIT cover page containing the disclaimer.

Sampling Rate = Resolution Quantization Level = Color Depth = Bit Depth = Number of Colors

Photo Editing Workflow

A simulation tool for evaluating digital camera image quality

EASTMAN EXR 200T Film / 5293, 7293

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

ISO INTERNATIONAL STANDARD

Extensive Works of ISO/IEC and the Current Status (ISO/IEC JTC1/SC28 and JBMIA SC28/WG4)

Detection and Verification of Missing Components in SMD using AOI Techniques

The Unique Role of Lucis Differential Hysteresis Processing (DHP) in Digital Image Enhancement

Quantitative Analysis of ICC Profile Quality for Scanners

Basic Resolution Testing using Test Charts

Correction of Clipped Pixels in Color Images

What is a "Good Image"?

a marriage between Film and Video Viper FilmStream Camera: A Technical Overview Abstract Introduction

Outline: Getting the Best Scans

WORKING WITH COLOR Monitor Placement Place the monitor at roughly right angles to a window. Place the monitor at least several feet from any window

IEEE P1858 CPIQ Overview

Update on the INCITS W1.1 Standard for Evaluating the Color Rendition of Printing Systems

EKT 314/4 LABORATORIES SHEET

It should also be noted that with modern cameras users can choose for either

Digital Art Requirements for Submission

This PDF file is best viewed at actual size (Command-H on the Mac; Control-H on the PC) to maximize the clarity of photos and screenshots.

New Features of IEEE Std Digitizing Waveform Recorders

According to the proposed AWB methods as described in Chapter 3, the following

DIGITAL PROCESSING METHODS OF IMAGES AND SIGNALS IN ELECTROMAGNETIC INFILTRATION PROCESS

Capturing and Editing Digital Images *

1. Redistributions of documents, or parts of documents, must retain the SWGIT cover page containing the disclaimer.

Figure 1 HDR image fusion example

ALEXA Log C Curve. Usage in VFX. Harald Brendel

Determining MTF with a Slant Edge Target ABSTRACT AND INTRODUCTION

Colour Management Workflow

The IQ3 100MP Trichromatic. The science of color

Richard Sharman.

Technical Note How to Compensate Lateral Chromatic Aberration

Background. Computer Vision & Digital Image Processing. Improved Bartlane transmitted image. Example Bartlane transmitted image

USAF Bar Resolving Power Test Chart

Digital database creation of historical Remote Sensing Satellite data from Film Archives A case study

DIGITAL SIGNAL PROCESSOR WITH EFFICIENT RGB INTERPOLATION AND HISTOGRAM ACCUMULATION

AN ADAPTIVE MORPHOLOGICAL FILTER FOR DEFECT DETECTION IN EDDY

This document is a preview generated by EVS

Optical design of a high resolution vision lens

On Contrast Sensitivity in an Image Difference Model

Modified slanted-edge method and multidirectional modulation transfer function estimation

Version 2 Image Clarification Tool for Avid Editing Systems. Part of the dtective suite of forensic video analysis tools from Ocean Systems

Exercise questions for Machine vision

Part Number SuperPix TM image sensor is one of SuperPix TM 2 Mega Digital image sensor series products. These series sensors have the same maximum ima

DECODING SCANNING TECHNOLOGIES

SEAMS DUE TO MULTIPLE OUTPUT CCDS

TECHNICAL SUPPLEMENT. PlateScope. Measurement Method, Process and Integrity

Evaluating a Camera for Archiving Cultural Heritage

KODAK NEXFINITY Digital Press. 256 Shades of Gray

Edge Preserving Image Coding For High Resolution Image Representation

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

An Efficient Color Image Segmentation using Edge Detection and Thresholding Methods

8.2 IMAGE PROCESSING VERSUS IMAGE ANALYSIS Image processing: The collection of routines and

Slide Scanning Converting Your Film Photographs to Digital. Presentation to UCHUG - 8/06/08 G. Skalka

Transcription:

IS&T's 22 PICS Conference Migration from Contrast Transfer Function to ISO 667- Spatial Frequency Response Troy D. Strausbaugh and Robert G. Gann Hewlett Packard Company Greeley, Colorado Abstract With the advent of the ISO standard 667- Spatial Frequency Response for Electronic Desktop Scanners it becomes useful to compare established methods, such as Modulation Transfer Function or Contrast Transfer Function (MTF/CTF) to the new standard method. This facilitates communication between companies, vendors, OEM suppliers and end users as to the actual performance being provided or specified. However, when making a change in measurement method in an established field, it is important to understand the relationship between prior measurement methods and the one being adopted. This is required to provide clear migration paths for vendors, manufacturers and reviewers from the old method to the new, while preserving the knowledge inherent in the body of data available from prior measurements. This paper reports comparisons and conversion methods between the ISO 667- and a common MTF/CTF method and how to relate measurements made using the two methods. A number of consumer class desktop scanners with different optical systems are compared when operated at the optical sampling rate (ppi) as well as lower and higher sample rates (ppi). Preliminary results indicate a good correlation is found between the methods though different conversion factors must be used for different sampling rates. Introduction One of the key performance attributes of a scanner is the ability of the scanner to appropriately resolve detail in scanned originals both transmissive and reflective. During the initial years of consumer desktop scanner design and sales, the scanner sample rate, specified as pixels per inch or ppi, was a well correlated to the actual resolving power of the scanner. For this reason, the ppi is referred to as the resolution of the scanner, when in fact, it is the sample rate of the scanner. In more recent years, the relationship of the ppi of a scanner to its ability to resolve detail in an original has decreased. For instance, a 2 ppi scanner today can not be expected to resolve twice the detail that a 6 ppi scanner could just a couple of years ago. In fact, in the process of specifying and building scanners, the ability of a scanner to resolve detail it s real resolution is described in terms of a modulation transfer function. However, the methodologies utilized to mesure and specify Modulation Transfer Function (MTF) in a scanner are not standardized, nor has the target used been standardized. This greatly complicates product design and product processes because differences between different MTF or CTF measurement methods and targets must be continually addressed. To address this problem, the ISO 667- Spatial Frequency Response for Electronic Desktop Scanners was created. The ISO 667- Standard test enables developers, users and manufacturers to specify and verify the resolution of a scanner. In addition, a standard measurement method for scanner resolution provides a basis for more generic measurement related to the human visual system as well as various reproduction technologies for digital images based upon scanned images. Finally, the ISO 667- standard test enables quantitative measurements by technical reviewers attempting to evaluate the actual resolving power of a scanner as opposed to a specified ppi. Modulation Transfer Function MTF) is a well-recognized method for evaluating the frequency response of an optical system. In MTF measurements a sweeping sine wave is input to the system and the modulation of that sine wave at the output of the optical element is measured. Unfortunately, while MTF has been applied in optics for some time, the application in scanners is less standard. Modulation Transfer Function, as typically defined presents several challenges for mass production of scanners. First, obtaining a swept sinusoidal input target on a reflective media is difficult. In addition, the modulation of the media itself will enter into the result measures the modulation of the target will typically decrease as the frequency increases. For truly accurate measurement, the target must be measured using a microdensitomer or similar device. This is not practical in a high volume environment. A second issue with MTF is that it is typically measured in a manner that requires some normalization of the optical electronic contrast function (OECF) of the scanner. Typically MTF is calculated as: 36

IS&T's 22 PICS Conference MTF = MTF max MTF min MTF max + MTF min Equation. Min/Max per cycle method to compute MTF. Where MTF max and MTF min are the maximum and minimum value in the sinusoidal modulation. The figure below shows two sinusoidal modulations with the same modulation range (max-min) but with different nominal average reflectance. The following two MTF results are calculated using the above formula: 2 8 6 4 2 8 6 4 2 26 74 34 Max Min MTF Curve 74 66.45 Curve 2 34 26.675 Figure. MTF calculated using min/max per cycle method. Note the significant difference in MTF reported. In this trivial case, normalizing to an average reflectance of 28 resolves the difference, but in a more general case where the OECF of the scanner is not well controlled, the problem becomes difficult if not insoluble. Modification to MTF addresses the limitations of traditional MTF namely the requirement for sinusoidal input target and the lack of exposure control. Two modifications to MTF are done. This new method will be referred to as CTF in this paper however it is often called MTF. In CTF the input target is not a sinusoidal but a square wave test chart (alternating dark and light line) at a given frequency or set of frequencies. This is a less pure measurement for two reasons. First, the square wave represents an impure frequency input and second, the CTF target is not a sweep it provides only particular input frequency. However, the square wave target is much more cost effective for a product test. The second factor is a modification of the calculation method. In CTF, the modulation of a high frequency pattern is compared to the modulation of a low frequency pattern. The resulting number is between and and represents no modulation to perfect modulation. CTF is calculated as: 66 Test Test max min CTF = ref ref max min Equation 2. Reference method to compute CTF/MTF. In this case the reference pattern provides a more robust estimate of the contrast range of the scanner without MTF modifications. However, CTF still requires a linear response from the scanner and one that does not result in saturation or clipping in either the test or reference patterns. More information about MTF/CTF as applied to reflective flatbed scanners can be found in reference. Figure 2 below shows the signals for a typical CTF test. Shown are the reference signal that provides a measure of the contrast of the scanner, a representation of an ideal CTF signal (the square wave) and the scanned CTF signal. The scanned CTF signal is modulated by the limited optical resolution of the scanner. To calculate CTF for this example use Equation 2, and the max and min values shown in the graph. Using these values the results obtained are: 25 Ref erence Signal 2 5 5 76 43 53 Ideal CTF Signal Scanned CTF Signal Max Min CTF Reference 76 2 CTF Signal 43 53.58 2 Figure 2. CTF/MTF calculated using a reference. Note that in the example shown, the signal is not centered around 28 counts. If the signal were shifted up or down by an offset in the scanner response, the CTF calculation would be the same. Summary of CTF/MTF Although these tests have been utilized in the industry they are not standard methods as applied to scanners. As such, they cannot be relied upon when changes in the manufacturing process are made. For instance, hanging vendors or changing target vendors or materials can render results not comparable. When comparing competitive products, as reviewers may do, the multiple ways to calculate MTF can cause confusion and misalignment with 37

IS&T's 22 PICS Conference specifications. Targets used with MTF tests are not a standard therefore are not controlled or easily available and variations in the printing and imaging process can produce, wide variations of the same test. Finally, variation in the exposure or OECF of differing scanners may cause variations in results that are difficult to identify or rectify. ISO 667- The ISO 667- was created to address these problems for consumer class scanners. The standard is based upon the ISO 2233 for electronic still pictorial cameras. Spatial Frequency Response () for scanners utilizes a slanted edge with a sharp contrast of 8 to. This tool utilizes this contrast between gray and dark gray to compute the values. The slanted edge is used because it removes aliasing effects by changing phase relative to the sensor elements 2. Slanted edge is noise durable and has super sampling capabilities, 3 which can sample to four times the Nyquist sampling rate. The 667- test target includes a gray step target that can be used to measure the OECF of the scanner and compensate for exposure and linearity difference between scanners. This is also very important for technical reviewers who are often operating scanners in a default mode, which means that exposure and gamma compensation, are often applied to the image. OECF is used to place in a linear space because is defined as a linear measurement. OECF is a table of values that 2 relates its value by approximation. The accuracy of the measurement is dependent on how well this approximation is calculated. The OECF is a good analysis tool because it will distort if corrupt data is present creating easy assessment of the quality of the data. Correlation of CTF and Data Since most processes currently include CTF tests or specifications, a method must be established to convert CTF to. This enables moving from an existing process to one based upon without loss of continuity. In testing the method and comparing it to the CTF method, several scanners were examined, spanning competitors, type, ppi and price points. The scanners tested were operated using various resolutions (ppi), sharpening, saturation and exposure settings. Changing these settings was necessary to verify if the algorithm was capable of detecting changes or ignoring them completely. First, scans were performed measuring the traditional CTF tests using five cycle samples, 3, 7, 5, 4, 8 line pairs per inch (lppi). All available CTF target frequencies were used to provide the maximum number of points useful to the two different measurement tools. All of the CTF tests were scanned in linear space, while separating red, green and blue and with no sharpening applied. The reference pattern for this test is a large fiducial (cross). The reference area captures a portion of the black and white transition so a high contrast is made. Next the algorithm was used on the same scanners using the Labview executable file available on the PIMA website Calculation Method There are two different types of executables available for, Matlab and Labview. We utilized the Labview file because it was easily run with Windows and no separate software was needed. Prior to running the Labview program the test targets were scanned with various scanning parameters and the images saved. When the Labview test program is run it first asks for the scanned image. Then a selection area must be created around the target image so the regions of interest (ROI) and gray scale patches can be analyzed. The gray scale patches act as a radiometric reference for the OECF of the device. 4 This is shown in the following figure. Figure 3. scanner target with ROIs and gray scale selected. The program then calculates the and displays four different graphs separating RGB for each of the slanted edges of the target. At least two edges, one vertical and the other horizontal, are needed to measure both the X and Y directions. In Figure 4 two measurements for X and two for Y were provided. This can be useful in identifying anomalous data for instance, if the X is very different from the two slanted edges, one would be suspicious of the data. The test does not require the target to be in linear space, and was tested by scanning with both linear and nonlinear tonal transformations. Results between linear and non-linear scans were comparable. Testing was done first at 3ppi then 6ppi and 2ppi. Scanned files became very large in memory size after 2ppi, so these were not included in this paper, although they will be examined later in the research. 38

IS&T's 22 PICS Conference.4 y = -3.3329x 2 + 4.55x -.476 R 2 =.9549.2.8.6.4.2.2.4.6.8 Figure 5. versus CTF @ 3ppi with extreme sharpening applied. Figure 4. Output of executable file displaying 4 outputs of the 4 slanted edges. When comparing the data from CTF and the data was extracted corresponding to frequencies measured in the CTF tests and plotted versus the CTF data. This plot was produced with the on y-axis and the CTF on the x axis as seen in the following figures. This allows easy comparison of the results between the two tests. Although all three channels, red, green and blue were close in numbers and graphical analysis only the green channel is used. Fitting the graphical results, shown in the figures, equations were created. Several equations were tested such as exponential, linear and others, but the best fit was found with a second order polynomial. Testing the accuracy of the best-fit equation an R squared parameter was generated, which is shown with the equations in the following figures. Impact of Sharpening on Comparison The plot of versus CTF should reveal a linear relationship because it is measuring the same physical parameter (resolution), but as can be seen in Figures 5 and 6, that is not always the case. Figure 5 shows versus CTF at 3 ppi where sharpening is applied to the scan and not to the CTF scan. Figure 6 shows the same measurement where no sharpening is applied to either scan. As can be seen, the application of sharpening to created a non-linear relationship between and CTF. This is expected, and does point out that sharpening must be considered when comparing or converting from to CTF..8.6.4.2 y =.924x 2 +.7544x +.5 R 2 =.9856.2.4.6.8 Figure 6. versus CTF @ 3ppi with no sharpening applied. Interestingly, at higher ppi, such as 2 ppi, the relationship between sharpened and non-sharpened CTF is much more linear. This is shown in Figure 7. One might expect this because at very high ppi for a given sharpening kernel a much smaller sharpening effect will be obtained. In addition, at high ppi, it may be expected that the optics by far dominate. 39

IS&T's 22 PICS Conference.8 y = -.966x 2 +.229x -.539 R 2 =.994 y =.42x 2 +.824x +.448 R 2 =.9954.6.8.4.6.2.4..3.5.7.9..2.2.4.6.8 Figure 7. versus CTF for the green channel @ 2ppi with medium sharpening. In addition to examining the impact of sharpening on scans, other parameters were varied, such as the amount of saturation, noise levels, and exposure time. Although this information is not included within the text of this paper it will be examined in future work. Comparison of and CTF without Sharpening When sharpening is eliminated from the data, a linear relationship is seen between the and CTF results. This is as expected and very encouraging when considering the prospect of converting CTF specifications to. Figures 8 and 9 show a plot of the versus CTF for 6 and 2 ppi from one of the test scanners (3 ppi results are shown in Figure 6). Notice the relatively linear relationship and the similarity of the fitted equations. However, it is also noted that the equation is not identical for the three ppi scans..8.6.4.2 y = -.437x 2 +.667x +.566 R 2 =.9927.2.4.6.8 Figure 8. versus CTF for the green channel @ 6ppi with no sharpening. Figure 9. versus CTF for the green channel @2ppi with no sharpening. Figure shows the three curves plotted on one graph. The difference between the three curves would indicate that a single equation could not be used for conversions at all ppi..8.6.4.2 Green 3 ppi 6 ppi 2 ppi.5 Figure. Curves obtained from 3, 6 and 2 ppi with no sharpening, versus CTF comparison for a one scanner. Conclusions A CTF resolution testing method was compared to the ISO 667- test. The results show the relatively linear relationship between CTF and when no sharpening is applied to either. When sharpening is applied to the image, the relationship becomes non-linear as might be expected, at least at lower ppi rating however, conversion can be successful allowing comparison of non-sharpened CTF specifications to sharpened measurements for a 4

IS&T's 22 PICS Conference given sharpening kernel. Note that itself may be sensitive to sharpening. Curve fits allowing conversion from CTF to were created for 3, 6 and 2 ppi scans with no sharpening applied. While the results are similar and of the same character, they are not identical. This indicates that a different conversion equation will likely be required for each ppi being considered. However, since CTF is only typically specified at one or two ppi settings, this is not considered problematic. Given these results, we believe will become an effective tool for use in scanner resolution specification or comparison. Once conversion of specifications from CTF to has been performed, future products can be analyzed or specified using alone. Future work will include the impact on of sharpening, noise, etc., and examinations of more scanners than have been tested to date. References. Gann, Robert G., Desktop Scanners, Hewlett Packard Co., 999. 2. Higgins, E.W., Juenger, A.K., Parulski, K., Computation of ISO Draft Standard Spatial Frequency Response, IS&T, 3. Burns, Peter D. and Williams, Donald, Slanted Edge MTF for Digital Camera and Scanner Analysis, IS&T, Portland, OR, 2, pg.35-38. 4. Williams, Don, User s Guide, win_auto., PIMA website, 2. Biography Troy D. Strausbaugh received his B.S. degree in Electrical Engineering from Colorado State University. Troy has performed research in optical and laser development, signals and systems, microelectronics as well as photolithography. Troy is currently working on image quality for Digital Imaging within Hewlett Packard. Robert G. Gann received his Ph.D. in Electrical Engineering from Colorado State University. Dr. Gann is currently a master engineer working on Imaging System Architecture in Hewlett-Packard s Digital Imaging organization. Dr. Gann has been working in image quality of digital imaging system since 988 and has authored several papers and books on scanner image quality. 4