INFITTING & OVERLAP HINGED DOORS

Similar documents
EXTRUTECH PLASTICS, INC. Custom Extruder of Close Tolerance Profiles

Pocket Door Installation Instructions

ICU TRACKLESS SLIDING DOOR

INSTALLATION INSTRUCTIONS KK-K9-F14-K K9 KIT FOR FORD EXPEDITION

INSTALLATION INSTRUCTIONS KK-K9-C12-K CHEVY IMPALA

Acoustical Surfaces, Inc.

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS and OPERATIONS & MAINTENANCE MANUAL for SUPER SIMPLEX DISAPPEARING STAIRWAYS

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

INSTALLATION INSTRUCTIONS

WPS crew Doors Installation instructions

Heavy Wall Applied Stop Tube Frame and Door Installation

Chapter 12 - Windows and Doors

Sun Windows General Information New Construction Hinged Door Installation Instructions

Swing Door Installation Manual

Senior Swing. Caution

ESA-300 Full Breakout

INSTALLATION GUIDE. TRANZFORM Sound TRANZFORM Space

Installation Guide. Evolve bi-fold. 8. Door restrictor- optional p9. 1. Before you start p2. 9. Adjustment. 2. Measuring and surveying p2

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

IMPACT DOOR 3000 SERIES. This Manual Covers All Doors Shipped To Date, Except For Revised Jamb Guards.

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

Installation Manual For ToddPod Outdoor Shower Enclosures

Shetland Stalls Installation Instructions

K9 KIT INSTALLATION INSTRUCTIONS CROWN VIC KK-K9-F7-K

Atrium Patio Door Field Service Manual

ICU TRACK SLIDING DOOR

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)

2300 BI-FOLD INSTALLATION GUIDE

Thermally Broken Framing and Door Installation

INSTALLATION INSTRUCTIONS

Sliding Glass Door Assembly and Installation Guide

FIG. #1 - ASD-90 & USD-90 Shower Door Assembly

Frameless Inline Door With Return QCI5263

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS K9-C20-32 & K9-C CHEVROLET 4 DOOR TAHOE, GMC YUKON, SUBURBAN and YULON XL

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

2. Skid should contain the following: A door & jamb B casing C seal cover kit & D extension jamb set (if ordered), E hardware box.

Vinyl Windows and Doors Manufactured by Pella Corporation

Motorized or Crank Operated Fortress Zipper Track Shade with Housing and Side Track Installation Instructions

K9 KIT INSTALLATION INSTRUCTIONS CROWN VIC with Fire Suppression System Model KK-K9-F7-K-FS

4-lite Patio Door. Installation Instructions

FIB-R-MAX STANDARD SINGLE DOOR

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

SLIDING GLASS DOOR ASSEMBLY INSTRUCTION Series 680/780

TRUE TECHNICAL SERVICE MANUAL - ALL MODELS. DOORS/DRAWERS/LIDS

Chapter 12 - Windows and Doors

DROPTRAC INSTALLATION INSTRUCTIONS

Contemporary 3 Panel Classic 5 Panel French Panel

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

Installation Instructions for Vista Air Vertically Folding Walls

Frameless Inline Door QCI5250

Vinyl Sliding Glass Door Assembly Instructions

Installation Recommendations for Finless Frame Doors

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION

Installation Instructions. Oakmont Folding Doors

Please read and understand all instructions before beginning. These instructions cover impact and non-impact aluminum French Door 650/750.

Lightline Movable Wall Installation Manual. Preliminary Draft #

Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors)

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

101B, 210X, ELM, VSTB Installation Manual

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS

PREHUNG DOOR SYSTEM INSTALLATION INSTRUCTIONS: FIBRECOMP COMBINATION UNITS

KS SERIES - VERTICAL INSTALLATION

LEGENDS RETRACTABLE DOOR SCREENS

Double Frameless Swing Door QCI5247

Mira Premium Series Bi-Parting French Sliding Patio Door Installation Instructions

INSTALLATION INSTRUCTIONS FOR FORGENT SLIDING PATIO DOORS RECOMMENDATIONS FOR COMMON INSTALLATION OF SLIDING PATIO DOORS.

GIRTS ON BACK OF BUILDING

INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL

UNIT 5: EXTERIOR DOORS AND WINDOWS

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS

INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO

western series 9500 f loor load The Volume Program window systems westernwindowsystems.com bi fold installation instructions

3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS

series 9500 top load bi4fold installation instructions

WOOD OUT SWING AWNING, CASEMENT, & HOPPER WINDOW

ESA-200 Fixed Sidelite

I n s t a l l a t i o n I n s t r u c t i o n s

INSTALLATION INSTRUCTIONS FOR CECO DOOR FLOOD RESISTANT DOOR AND FRAME ASSEMBLIES

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS

Instructions for the installation of Ellison Bronze balanced door models #137 & 138

Weatherfold 4s 50, 75 & 100

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

Oxford Stalls Installation Instructions

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

Frameless Heavy Glass Door with Wall Mount Hinges

POCKETING MULTI-SLIDE DOOR SYSTEM

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE

INSTALLATION INSTRUCTIONS

Frameless Inline Door QCI5254

Steel Reinforced Joining Guide (Horizontal / Vertical)

Transcription:

INFITTING & OVERLAP HINGED DOORS INSTALLATION MANUAL

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR OUR COMPLETE LINE TESTED & APPROVED Vertical Lift Bi-Parting Sliding BUILDING CERTIFICATION & GREEN TARGETS INDOOR ENVIRONMENTAL QUALITY LIFE-CYCLED BENEFITS Hinged-Infit & Overlap Horizontal Sliding 2

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL CONTENTS I. Important Notice 4 Figure 1: Infitting Door with Flush Sill 5 Figure 2: Infitting Door with High Sill 6 Figure : Overlap Door with Flush Sill 7 Figure 4: Overlap Door with High Sill 8 Figure 5: Double Infitting Door with Flush Sill 9 Figure 6: Double Infitting Door with High Sill 10 II. Installation Procedure 1 1. Installing Door 1 2. Electrical hookup of heat circuits (for freezer applications only) 15. Final Inspection 15 III. General Maintenance 17 IV. Troubleshooting Malfunctions & Problems 19 V. Parts List Parts Figure 1: Heater Details for lnfitting Door with Flush Sill 20 Parts Figure 2: Heater Details for lnfitting & Overlap Door with High Sill 21 Parts Figure : Gasket Assembly for Infitting Doors 22 Parts Figure 4: Gasket Assembly for Overlap Doors 2 Parts Figure 5: Hinge Assembly for Infitting Doors 24 Parts Figure 6: Latch Assembly for Infitting Door 24 Parts Figure 7: Hinge Assembly for Overlap Doors 25 Parts Figure 8: Latch Assembly for Overlap Doors 25 Parts Figure 9: Outside Release Assembly for Overlap Doors 26 Parts Figure 10: Inside Release Assembly for Overlap Doors 27

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR IMPORTANT I NOTICE Before beginning installation, please read this manual in its entirety. This door has been designed and built to provide years of trouble-free service in heavy duty commercial and warehouse operations. This Installation Manual may be used for all of the following door types: Infitting Door with Flush Sill Infitting Door with High Sill Overlap Door with Flush Sill Overlap Door with High Sill Double Infitting Door with Flush Sill Double Infitting Door with High Sill Reference to the following figures will provide general specifications for your model. Sub-assemblies are provided for rapid installation and adjustment. 4

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL INFITTING DOOR WITH FLUSH SILL Figure 1 All freezer doors must have separate 120 Volt supply for heater cables Jamb depth 5-1 2 Metal clad door Hardware Backing Hinge Buck opening = H.I.C. + 2 Latch Metal clad casing H.I.C. Pull handle Polyiso Insulation Sweeper gasket Buck opening = W.I.C. + 4 5-1 2 W.I.C. Return Safety jamb release Gasket Wallside Jamb depth Note: Left swing shown, right swing opposite. Note: Heat in three () sides of frame and in bottom of door (freezers only) 1-1 2 Hingeside Polyiso Insulation Note: Doors 60 x 84 and over will be required to use a floor roller with non-camlift hinges 5

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR INFITTING DOOR WITH HIGH SILL Figure 2 All freezer doors must have separate 120 Volt supply for heater cables Jamb depth 5-1 2 Metal clad door Hinge Buck opening = H.I.C. + 4 Latch Metal clad casing Hardware Backing H.I.C. Pull handle Polyiso Insulation Sweeper gasket Buck opening = W.I.C. + 4 W.I.C. 5-1 2 Return Safety jamb release Gasket Wallside Jamb depth Note: Left swing shown, right swing opposite. 1-1 2 Polyiso Insulation Hingeside 6

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL OVERLAP DOOR WITH FLUSH SILL Figure All freezer doors must have separate 120 Volt supply for heater cables Jamb depth 7-1 2 Hinge Latch Metal clad door Metal clad casing Hardware Backing Buck opening = H.I.C. + 2 Outside handle H.I.C. Pull handle Polyiso Insulation Sweeper gasket Buck opening = W.I.C. + 4 7-1 2 1-1 2 W.I.C. Gasket Inside Handle Polyiso Insulation Wallside Return jamb Hingeside 9-1 4 Jamb depth Note: Left swing shown, right swing opposite. Note: Heat in three () sides of frame and in bottom of door (freezers only) Note: Doors 60 x 84 and over will be required to use a floor roller with non-camlift hinges 7

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR OVERLAP DOOR WITH HIGH SILL Figure 4 All freezer doors must have separate 120 Volt supply for heater cables Jamb depth 7-1 2 Hinge Latch Buck opening = H.I.C. + 4 Metal clad casing Metal clad door Outside handle H.I.C. Polyiso Insulation 7-1 2 Buck opening = W.I.C. + 4 = 40 7-1 2 W.I.C. Gasket Inside Handle Return jamb Wallside 9-4 Jamb depth Note: Left swing shown, right swing opposite. 1-1 2 Polyiso Insulation Hingeside 8

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL DOUBLE INFITTING DOOR WITH FLUSH SILL Figure 5 All freezer doors must have separate 120 Volt supply for heater cables 5-1 2 Jamb depth 1-1 2 Hardware Backing Hinge Metal clad casing Latch Pull handle H.I.C. Metal clad door panel Polyiso Insulation Sweeper gasket Buck opening = W.I.C. + 4 W.I.C. Inactive Leaf Active Leaf Buck opening = H.I.C. + 2 5-1 2 Return jamb Wallside Safety release Gasket Jamb depth 1-1 2 Hingeside Polyiso Insulation 9

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR DOUBLE INFITTING DOOR WITH HIGH SILL Figure 6 All freezer doors must have separate 120 Volt supply for heater cables Jamb depth Header Latch 5-1 2 Hinge Latch Metal clad casing Hardware Backing H.I.C. Cane Bolt Metal clad door Polyiso Insulation Buck opening = W.I.C. + 4 5-1 2 W.I.C. Buck opening = H.I.C. + 4 Inactive Leaf Active Leaf 1-1 2 5-1 2 Wallside Safety Release Gasket 5-1 2 Jamb depth Polyiso Insulation Hingeside 10

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL 11

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR 12

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL II INSTALLATION PROCEDURE I. Installing Door a ) The opening of the door frame must be plumb, level and square. b) Apply Butyl caulk to the back of the door frame to provide a seal between the frame and the wall before installing the frame in the opening as shown in Figures 8-9 on page 14. c) If the floor slopes, start by setting the high side of the door frame first and shim to raise the other side so that the top of the door frame opening is level. d) Plumb as shown in Figure 7 and attach securely to door bucks. Make sure the inside of the door frame is plumb and square to ensure proper sealing of the door against the frame. e) Before mounting all bolts in frame, hang the door in the frame and check position of latch & strike (Door frame may need to be shifted to the left or right to level the latch to the strike). Note: Ensure the door is level in the opening of the frame. Figure 7 Mounting door in opening Left Side View Wall Shim if not plumb Door frame Top View Shim if not plumb Door frame Wall Door panel Vapor seal with caulking by installer Door panel Plumb line Floor Note: If walls are not plumb and parallel, shim as required. Note: If mounting walls are not on the same surface plane, shim as required. 1

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR f) Mount frame to wall as shown in Figures 8-9 below for frames with and without an inside casing. g) Once door is securely mounted apply sealant in all seams to provide vapor seal. h) Open door and check for freedom of movement. i) For flush sill doors, trim the neoprene foam gasket running down the sides at the bottom of the door so that it is flush with the floor as shown in Figure 10. Figure 8 Door frame mounting - with inside casing 8 Carriage bolt with nut and washer Inside vertical casing Lumber Sealant Butyl calk (typical) Lumber or channel trim Wall Outside vertical casing Note: All caulking is field applied. Butyl caulk between wall and frame and sealant in seams. Figure 9 Door frame mounting - without inside casing Sealant Butyl calk (typical) Lumber or channel trim Wall Outside vertical casing 8 Lag screw Lumber Note: All caulking is field applied. Butyl caulk between wall and frame and sealant in seams. 14

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL Figure 10 Neoprene foam gasket trimming Neoprene foam gasket Neoprene sweep gasket Front View Trim Neoprene foam gasket only Side View 2. Electrical hookup of heat circuits (for freezer applications only) 1) Before proceeding, check to see that available power supply (voltage and phase) matches that on name plate located adjacent to junction box on door frame. 2) Consult local electrical codes before proceeding with installation. ) Note: This unit must be properly grounded. A separate power supply (120V) is needed for each door. 4) Connect proper voltage to lead wires provided (Black, White, Green) as stated on name plate to junction box(es) mounted on door frame. (See Parts Figures 1 & 2) 5) If applicable, make sure that jumper cable is installed between door frame and door panel.. Final Inspection 1) Make sure door is plumb, level and square. This is critical for proper seal. If necessary to increase the pressure on the perimeter gasket, adjust the latch strike to the seal. 2) Recheck all steps above. Inspect door and frame. Make sure that door can travel freely (manually) from full closed to full open without obstruction. ) When installation is complete, store this manual in a safe place for future reference. 15

16

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL III GENERAL MAINTENANCE a) Maintenance on door parts should be performed as specified in the table shown below: Door Part Time Frame Maintenance Lubrication Every 6 months The frequency of lubrication is governed by the environmental conditions at the location of the door. The self-lubricating bushings, in normal service, need not be lubricated. However, it is recommended that a few drops of light oil periodically be used on all moving parts. Door gaskets and inner edge of door Latches, strikes, fasteners (includes all hardware) Every months Every months Clean gaskets to allow for smooth contact between door and gaskets. (Soap and water is recommended for cleaning) Check and re-tighten as required. Sealant Every months During the life of the door it is possible for the factory sealant in the seams and joints to come loose, either from abuse or normal use. It is critical that all seams and joints are kept vapor tight at all times Inspect seams and joints (of door, window, and frame) for loose or missing sealant. Approved sealant must be applied if replacement is necessary. Failure to do so will affect watertight integrity and cause deterioration of the door. Failure to maintain sealant will void the warranty. Special care must be taken in areas that are washed down with de-greasing chemicals. Electrical components must be protected and lubricants must be washed from the operator and other moving parts immediately to prevent permanent damage. 17

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR b) R eference pictures 1. Re-tightening latches, strikes etc. 18 2. Sealant replacement

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL IV TROUBLESHOOTING MALFUNCTIONS & PROBLEMS All door assemblies are thoroughly tested and inspected before leaving our factory. If a problem develops when the door is first installed, it is recommended that the installation manual be read through carefully again to determine whether an error has been made in the installation process. If you require further assistance, please contact us at the address and phone number below: Kingspan Insulated Panels, Inc. 726 Summerhill Drive Deland, FL 2724-2024 Phone (86) 626-6789 E-Mail: info@kingspanpanels.us 19

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR PARTS V LIST The Parts List is provided for your convenience when ordering replacement parts. Please use the model and serial number of your door when ordering parts, as this will expedite shipment of required parts and avoid unnecessary correspondence. Parts Figure 1: Heater for Infitting Door with Flush Sill (Freezer only) Detail: Heat in frame Detail: Heater cable routing 1 2 4 6 7 8 8 4 2 5 Part No Description 1 Aluminum Heater Cover Extrusion 2 Aluminum Foil Tape Heater Wire 4 Heater Wire Channel Extrusion 5 20 Ga. Galv Trim 6 Bell Box (Three Hole) 7 Jumper Cable 8 PVC Tubing 20

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL Parts Figure 2: Heater for Infitting and Overlap Door with High Sill (Freezer only) Detail: Heat in frame Detail: Heater cable routing 1 2 4 5 Part No Description 1 Aluminum Heater Cover Extrusion 2 Aluminum Foil Tape Heater Wire 4 Heater Wire Channel Extrusion 5 Bell Box (Three Hole) 21

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR Parts Figure : Gasket Assembly for Infitting Doors Perimeter door gasket Sweep gasket - Flush sill only 2 1 Part No Description 1 Neoprene Sweep Gasket - 1 16 x 2 2 Hollowcore Neoprene Gasket - 1 2 x 1 1 4 Note: Double sweep gasket for freezer doors only. 22

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL Parts Figure 4: Gasket Assembly for Overlap Doors Perimeter door gasket Sweep gasket - Flush sill only 2 1 Part No Description 1 Neoprene Sweep Gasket - 1 16 x 2 2 Neoprene Foam Gasket - 1 2 x 2

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR Parts Figure 5: Hinge Assembly for Infitting Doors 1 Part No Description 1 Hinge Base 2 Hinge Butt 2 4 #14 x 1 1 4 Phillips Head Screw 4 #14 x 1 4 Phillips Head Screw Parts Figure 6: Latch Assembly for Infitting Doors 2 1 Part No Description 1 Latch Base 2 Latch Strike #14 x 1 4 Phillips Head Screw 24

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL Parts Figure 7: Hinge Assembly for Overlap Doors 1 2 4 Part No Description 1 Hinge Base 2 Hinge Butt 8 x 2 1 2 Cap Bolt 4 8 Flange Nut Parts Figure 8: Latch Assembly for Overlap Doors 1 2 Part No Description 1 Latch Strike 2 Latch Base #14 x 1 4 Phillips Head Screw 4 Bolt Lock 4 25

INSTALLATION MANUAL HERCULES INFITTING & OVERLAP HINGED DOOR Parts Figure 9: Outside Release Assembly for Overlap Doors 1 2 Part No Description 1 Outside Release Handle 4 2 Outside Release Handle Bracket #14 x 1 4 Phillips Head Screw 4 Outside Handle Pin 26

HERCULES INFITTING & OVERLAP HINGED DOOR INSTALLATION MANUAL Parts Figure 10: Inside Release Assembly for Overlap Doors 2 1 4 Part No Description 1 Inside Release Handle 2 Inside Release Handle Bracket #14 x 2 Phillips Head Screw 4 Plastic Block - Freezer Doors only 27

Kingspan Insulated Panels 726 Summerhill Drive Deland, FL 2724-2024 Phone (86) 626-6789 E-Mail: info.na@kingspanpanels.com www.kingspanpanels.com 1/17