ND 510 ND 550 Y Z SPEC FCT MOD

Similar documents
ND 530 ND 570. Reference mark crossed over datum points are now stored in nonvolatile memory. Blinking: Waiting for confirmation from operator.

Select datum Page backward in parameter list

Select datum Page backward in. parameter list

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED,

User s Manual ND 930 ND 970. Position Display Units for Lathes 5/95

User s Manual. Position Display Units for Milling Machines 9/2000

User s Manual ND 221 B. Measured Value Displays

* Confirm entry value Actual value and input display. Select datum. . set display to Value iron. Wsegmenr LED, * Page backward in

IBV 100/EXE 100 Interpolation and Digitizing Electronics

Operating Instructions. VRZ 740,780 Bidirectional Counters DR. JOHANNES HEIDENHAIN

User's Manual POSITIP 855. for Lathes. April 1996

Product Information. ERN 1085 Incremental Rotary Encoder with Z1 Track

100S READOUTS APPLICATIONS FOR GENERAL PURPOSE REFERENCE MANUAL

Touch Probe Cycles itnc 530

Touch Probe Cycles TNC 426 TNC 430

VUE READOUTS REFERENCE MANUAL

200S READOUTS REFERENCE MANUAL

DIGEM f 96 x 48 EK. Applications. Description

Wizard 450/450L Digital Readout Operations Manual

DRO 100 REFERENCE MANUAL

User s Manual Cycle Programming TNC 320. NC Software

Angle Encoder Modules

Product Information. ECN 413 ECN 425 ERN 487 Rotary Encoders for Elevator Drive Control (IP64 Degree of Protection)

Product Information. AK ERM 2xx0 TTR ERM 2x00 Modular Angle Encoders with Magnetic Scanning and Mechanical Fault Exclusion

EnDat 2.2 Bidirectional Interface for Position Encoders

Product Information. ECN 413 ECN 425 ERN 421 ERN 487 Rotary Encoders for Drive Control in Elevators

DRO 200T REFERENCE MANUAL

Product Information. EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface

Product Information. ECA 4000 V Absolute Modular Angle Encoder for Application in High Vacuum

Rotary Encoder System Compact Model Range

Digital Readouts for Manually Operated Machine Tools

RGH24 encoder system. Data sheet L C. RGH24 readhead: RGS20 scale:

Product Information ECN 424 S EQN 436 S. Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications

Product Information. ECA 4000 V Absolute Modular Angle Encoder for Application in High Vacuum

Product Information. RCN 2000 RCN 5000 RCN 8000 Absolute Angle Encoders for Safety-Related Applications

Product Information ECN 424 S EQN 436 S. Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications.

Product Information ROC 424 S ROQ 436 S. Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications

Product Information. ECN 1313 ECN 1325 ERN 1387 Rotary Encoders with Plane-Surface Coupling for Elevator Servo Drive Control

User s Manual. F2 Calculator. A metering component for thermal energy applications

Manual WDRO-L DIGITAL READ-OUT UNIT

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER

RGH25F encoder system

Computer-14d - xx - 144a

EnDat 2.2 Bidirectional Interface for Position Encoders

Product Information. ERM 200 Series Modular Magnetic Encoders

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

rotary encoder system

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Digital Readout. Type: BC-01-HS

RGH34 encoder system. Data sheet L A. RGH34 readhead and RGI34 interface: RGS40 scale:

DIGITAL STORAGE OSCILLOSCOPES

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE

Electronic timer CT-TGD.22

DM 162 S-DIAS Digital Mixed Module

NUMERIK JENA. LIA Series. Exposed Linear Encoder with Signal Control

Product Overview. Rotary Encoders with Optimized Scanning

Product Information. EBI 1135 Absolute Rotary Encoder, Multiturn Feature via Battery-Buffered Revolution Counter

Product Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface.

Q-SERIES. Amplifiers. QPAIR Redundancy Switch Amplifier System. Installation & Operation Manual

ABSOLUTE MAGNETIC ROTARY ENCODER ANALOG

2016 Motorized Shades Basic Programming

Manual MicroProgel TC 323

Copyright X02827C00 - Ed. 1-04/16

Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS

Encoder - Absolut 2RMHF-SSI

STYLE RA DIO France Inter - DCF

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

PWM 9. Universal Test Unit PWM 9 2/2004. Description. Dimensions. Mounting. Electrical Connection. Features

DIGITAL LENGTH GAUGES

Incremental hollow shaft encoder BRIH EcoMag

ProScale. Compact LCD Readout. Installation & Operation

ProScale Compact LCD Readout. Operation. Firmware version C 2.xxx and higher

AMANO PIX-21. Electronic Time Recorder. Operation Manual

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

EL 300. Operational Manual. Digital Readout System For Machine Tool

Datuming And Tool Setting Instructions for Renishaw Tool Touch Probe

Three-phase monitoring relays

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Electrical devices may only be mounted and connected by electrically skilled persons.

Digital Readout. Type: BC-01

RGH22 encoder system. Data sheet L B. RGH22 readhead. RGS20 scale

RGH41 encoder system. The Renishaw RGH41 series is a non-contact optical encoder system, providing highly-reliable positional feedback.

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

EL 400. Operational Manual. Digital Readout System For Machine Tool (Ball Scale Interface)

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

EVOLUTE absolute optical encoder with Yaskawa serial communications

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

LENORD. +BAUER... automates motion. Magnetic incremental encoder GEL 293 for heavy duty applications. Technical Information Version 04.

Error-Free Workpiece Transfer. HEIDENHAIN ROQ rotary encoders in INDEX lathes TECHNOLOGY REPORT

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

ISOMETER IRDH575. Approvals

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Phase and neutral overcurrent protection

Dialight Daylight Harvesting Sensor User Guide

Transcription:

HEIDENHAIN Working with the digital readouts ND 510 ND 550 Actual value and input display (7-segment LED, 8 decades and sign) Downwards: X-axis, Y-axis, ND 550 only: Z-axis Select coordinate axis (Z-axis with ND 550 only) Select axis-based operating parameters Numeric keypad and decimal point X Y Z 7 8 9 4 1 5 2 6 3 Sign Change parameter 1 2 CL 0 SPEC FCT MOD ENT Confirm entry values REF 1 2 in. SCL HEIDENHAIN Status indicators Call operating parameters Page forward in parameter list Datum setting function Select datum Page backward in parameter list Clear entry CL plus two-digit number: select parameter Clear parameter entry Indicator Meaning REF in. Reference mark was crossed over datum points are now stored in non-volatile memory. Blinking: Waiting for reference mark to be crossed over. Position values displayed in inches. 1 / 2 Datum point 1 / Datum point 2 currently active. SCL Scaling factor active. Define workpiece edge as datum. Blinking: Waiting for operator to confirm selection. Define centerline between two workpiece edges as datum. Blinking: Waiting for operator to confirm selection.

The ND 510 and ND 550 digital readouts accept HEIDENHAIN linear encoders with sinusoidal output signals. These linear encoders have one or more reference marks, preferably of the distancecoded type. When a reference mark is crossed over, a signal is generated which identifies that position as a reference point. After switch-on, simply crossing over the reference mark restores the relationship between axis positions and display values last defined by datum setting. With distance-coded reference marks, a maximum traverse of only 20 mm is sufficient to re-establish the relationship between axis positions and display values after switch-on. Switch-On Turn on the power The power switch is located on the rear panel. The display shows and REF blinks. Turn on reference mark evaluation Press the ENT key. The display shows the value last assigned to the reference mark position, the REF indicator glows and the decimal point blinks. Cross over the reference mark in each axis Move the axes one after the other until the display becomes active and the decimal point glows. The display unit is now ready for operation. If you do not wish reference mark evaluation, press CL instead of ENT. Setting the Datum The datum setting procedure assigns a display value to a specific axis position. Two separate datum points can be defined. You can switch from one datum to the other Z at the touch of a key. Use datum 2 if you want to display incremental values. Y Select the datum. X Select the coordinate axis in which the tool moves, for example the X-axis. Touch the workpiece with the tool. Touching the workpiece Enter the position of the tool center with the numeric keypad, for example X = 5 [mm]. The minus sign can only be entered when at least one digit is shown in the display. The display unit stores the value for this tool position. Follow the above procedure for other axes.

Datum Setting Functions The special functions which your display unit is capable of allow you to define a workpiece edge or the centerline between two workpiece edges as the datum. With the SPEC FCT feature, the display unit takes into account the tool diameter you entered in operating parameter P25. Workpiece edge as datum Select the datum. Z Press the SPEC FCT key once. The indicator "Workpiece edge as datum" starts blinking. Y The indicator glows. Select the coordinate axis in which the tool moves. The selected coordinate axis glows more brightly. Touch the workpiece with the tool. Workpiece edge as datum The display shows the current position of the edge. Enter the new coordinate value for the workpiece edge that was touched. The display unit sets the workpiece edge to the new value and displays the position of the tool center based on the new datum. This function ends automatically. Centerline between two workpiece edges as datum Select the datum. Press the SPEC FCT key twice. The indicator "Centerline as datum" Z starts blinking. The indicator glows. Select the coordinate axis in which the Y tool moves. The selected coordinate axis glows more brightly. X? Touch the first workpiece edge with the tool. The decimal point in the display blinks. Touch the second workpiece edge with the tool. Centerline as datum The display shows the current position of the centerline. Enter the new coordinate value for the centerline between the two touched workpiece edges. The display unit sets the centerline to the new value and displays the position of the tool center based on the new datum. This function ends automatically. X? X X Aborting the datum setting functions To abort when the indicator for the function is blinking: Press CL. To abort when the indicator for the function is glowing steadily: Press SPEC FCT.

Non-linear Error Compensation To work with the non-linear error compensation it is necessary to activate the function via the operating parameter P40. traverse the reference marks after switching on. enter the compensation values in the table. For every axis compensation values can be entered over 16 compensation points. To determine the compensation values with a comparator system from HEIDENHAIN, such as VM 101, you must select the REF display. Selecting the Compensation Value Table Select the operating parameter P00 and enter the code number 105 296. Use the following keys for the entries: Key MOD Function Save input value and select next input parameter. 1 / 2 Save input value and select preceding input value. SPEC FCT Select REF display. ENT Save entry. Exit compensation value table. CL Delete entry. Delete all compensation values. Enter the parameters and compensation values as follows: Display Entry Enter the axis to be compensated, e.g. X. Enter the axis causing the error, e.g. X, i.e. X = F(X). Enter the datum on the axis causing the error. Enter the distance of the compensation points on the errorcausing axis, e.g. 14 (= 2 14 µm = 16.384 mm). Minimum input value: 10 (= 1.024 mm) Maximum input value: 23 (= 8388.608 mm) Select compensation point No. 1. The compensation point number can be seen while pressing the MOD key. After letting go of the MOD key the coordinates of the selected compensation point can be seen in the upper line. Enter the compensation value in the lower line. Enter all following compensation points. Delete all compensation values: Display Entry Press key CL. Press key ENT. Compensation values are deleted.

Working with Scaling Factors The ND 510 and the ND 550 can display the axis traverse lengthened or shortened by a scaling factor. You enter a scaling factor separately for each axis in the user parameter P12, then activate the scaling factor function with the user parameter P11. SCL is highlighted. Error Messages Message Cause and effect Traverse distance with datum setting function (SPEC FCT) is too short Incorrect input value Input frequency too high for encoder input (will occur for example when traverse speed too high) Internal counter overflow Error while crossing over reference marks To clear the error message: Switch of the display unit. Should any of these error codes recur, contact your HEIDENHAIN service agency. Compensation values for nonlinear axis error compensation have been erased Datums have been erased Erase the operating parameters If all decimal points light up, the measured value is too large or too small. Set a new datum. To clear error message : When you have removed the cause of the error, press CL.

Operating Parameters User Parameters User parameters are operating parameters that can be changed without entering the codes: P00 to P25 Axis assignment Parameters which are entered separately for each axis have axis codes: "1" signifies the X-axis, "2" the Y-axis, and (with the ND 550) "3" the Z-axis. A point separates the axis code from the parameter number. In the operating parameter list, these parameters are set off with a superscript " A ", the parameter for the X-axis (e.g. ) is in the list. You select axis-specific operating parameters with the yellow arrow keys. To call the operating parameter list: Press MOD. To go directly to a certain operating parameter: Press and hold CL, then press the first digit of the parameter number. Release both keys and enter the second digit of the parameter number. Protected Operating Parameters In order to change protected operating parameters, the code number 95 148 must be entered via P00 Code: They remain accessible until the position display is switched off. To page through the operating parameter list: Page forward: press MOD. Page backward: press the 1 / 2 key. Any changes are automatically activated when you resume paging. To change a parameter setting: Change the value with the minus key, or Enter the desired value directly, e.g. for P25. To correct an entry: Press CL. To exit the operating parameters: This activates all changes made. Operating Parameter List Parameter Meaning Function / Effect Setting Scaling Tool Code Number 95148: protected operating parameter 105296: select compensation value table Unit of measurement Radius-/diameter display A Scaling factor Scaling factor A Tool diameter Display in mm Display in Zoll Radius Diameter Scaling factor on Scaling factor off Enter value for each axis separately Enter tool diameter

Operating Parameter List cont'd. Parameter Meaning Function / Effect Setting Model Counting direction A Signal period [µm] Reference marks Normal (Direction: Positive) Inverse (Direction: Negative) Signal period of encoder A (Period:) 2, 4, 10, 20, 40, 100, 200 Subdivision of the encoder signals A (Subdivision:) 4, 2, 1, 0.8, 0.5, 0.4, 0.2, 0.1 Select error compensation Error compensation not active Linear error compensation 1) A Compensation 99 999 < P41 < + 99 999 [µm/m] Reference marks A Encoder Linear error compensation active Non-linear error compensation active One reference mark Distance-coded with 500 SP (SP = signal period) Distance-coded with 1000 GP (e.g. for LS 303 C / LS 603 C) Distance-coded with 2000 SP Distance-coded with 5000 SP Monitoring off (Alarm Off) Encoder monitoring A Monitoring on (Alarm On) Axis display A Display measured position (Axis) Do not display measured position / no encoder Function of Resets display to zero CL key Does not reset display to zero 1) Calculate the entry value for P41 Example: Displayed measuring length La = 620.000 mm Actual length (determined with, for example, the VM 101 comparator system from HEIDENHAIN) Lt = 619.876 mm Length difference L = Lt La = 124 µm Compens. factor k: k = L / La = 124 µm / 0.62 m = 200 [µm/m] Parameter Settings for HEIDENHAIN Linear Encoders P43 Display step (unit: P01) mm inches LS 303 20 one single 0.005 0.000 2 4 Subdivision P32 LS 603 dist.c. 1 000 0.01 0.000 5 2 LB 302 40 one single 0.01 0.000 5 4 LIDA 10x dist.c. 2 000 LB 3xx 100 one single 0.025 0.001 4 dist.c. 1 000 0.05 0.002 2 0.1 0.005 1 Example: Linear encoder with signal period s = 20 µm Desired display step a = 0.005 mm Subdivision P32 = 0.001 s / a = 4

Rear Panel Inputs for HEIDENHAIN linear encoders (ND 510: 2, ND 550: 3) with sinusoidal output signals (7µA pp to 16 µa pp ), Connecting cable max. 20 m (66 ft), Input frequency max. 50 khz with 6 m/20 ft cable (35 khz with 10 m/32.8 ft, 20 khz with 20 m/66 ft) X3 X2 X1 Power switch Ground terminal Interfaces X1, X2 and X3 comply with the recommendations in EN 50 178 for separation from line power. Installation You can mount the display unit on a surface using M4 screws, or on a tilting base from HEIDENHAIN (Id.-Nr. 281 619 01). 93+2 3.66+.08" 43.3 1.704" 92 3.622" M4 56±0.2 2.204±.008" 20.79" 0 21±0.2 1±.008" 209±0.2 8.228±.008" 230±0.2 9.055±.008" 29+0.5 1.14+.02" Power Supply and Connection Danger of electrical shock! Unplug the power cable before opening the housing. Connect a protective ground. This connection should never be interrupted. Danger to internal components! Do not engage or disengage any connections while the unit is under power. Use only original replacement fuses. Primary-clocked power supply. Voltage range 100 V to 240 V ( 15% to +10 %) Frequency 48 Hz to 62 Hz Power consumption ND510: 9 W, ND550: 12 W Line fuse F 1 A (in unit) Minimum cross-section of power cable: 0.75 mm 2 To increase the noise immunity, connect the ground terminal on the rear panel to the central ground point of the machine. (Minimum cross-section 6 mm 2 ) Ambient Conditions Temperature range Operation: 0 C to +45 C (32 F to 113 F) Storage: 30 C to +70 C ( 32 F to 158 F) Rel. humidity Annual average: < 75%; maximum: < 90% Weight 2.3 kg DR. JOHANNES HEIDENHAIN GmbH Dr.-Johannes-Heidenhain-Straße 5 D-83301 Traunreut, Deutschland (0 86 69) 31-0. 56 831 FAX (0 86 69) 50 61 FAX Service (0 86 69) 31-12 72 TNC-Service (0 86 69) 31-14 46 (0 86 69) 98 99 281 615-23 SW 246 119 02 10 6/99 H Printed in Germany Subject to change without notice