Distribution Transformers

Similar documents
Substation transformers

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Distribution/Substation Transformer

Howard Smart Transformer Specification Guide

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

SECTION TRANSFORMERS

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Two- and three-phase MagneX interrupter

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

CITY OF TACOMA Transmission & Distribution

Figure 1. Two- and Three-phase MagneX Interrupter.

Three-phase pad-mounted compartmental type transformer

7. INSPECTION AND TEST PROCEDURES

Liquid-Filled Transformers

Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

35 kv Class M.O.V.E. DirectConnect elbow arrester

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

POSI-BREAK Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Functional specification for 3-in-1 pad-mounted multi-phase 32-step voltage regulator with communication-ready controls

Eaton s Cooper Power Series DEADFRONT ARRESTERS

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

VariSTAR Type AZU heavy-duty distribution-class under-oil MOV surge arrester

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

B. Manufacturers: Square-D, G.E. or Westinghosue.

OIL-IMMERSED ARC-SUPPRESSION COILS

Type DMX-N Surge Arresters Maximum System Voltage 2 to 36 kv

SECTION 5 TRANSFORMERS

INTERNATIONAL STANDARD

Introduction. Centrado leading-edge transformer. Introduction

Section 2 Outdoor Voltage Transformers

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

UFGS (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Three-Phase VFI Padmount Transformers. Double Duty in a Single Package. www. ElectricalPartManuals. com

SINGLE-PHASE VSV SWITCH

Basic Principles and Operation of Transformer

Mechanical Design. Brian Brinson Mechanical Design Manager.

COOPER POWER. UltraSIL Polymer-Housed VariSTAR Type U2Surge Arrester for Systems through 275 kv IEC 10-kA; Line Discharge Class 2 SERIES

The relative simplicity of transformers belies their. Transformer Fundamentals

Distribution transformers Part 2 Ground mounted transformers not closecoupled

UNIFIED FACILITIES GUIDE SPECIFICATIONS

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Transformer Testing & Maintenance Fundamentals. AVO Training Institute, Inc. 2018

Onsite Mobile AC High Voltage Test System

SINGLE-PHASE VSV SWITCH

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

Specialty Switches. Inertia Engineering & Machine Works, Inc Hardaway Road, Stockton CA 95215

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Transformer Factory Testing

SECTION PANELBOARDS

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

Power-Sure 700. Technical Data TD158001EN. Contents

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

UltraSIL Polymer-Housed Evolution Distribution Class Surge Arrester Certified Test Report

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION DISTRIBUTION SWITCHBOARDS

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

Power transformers for Network, Rectifiers, Furnace

Power Processor - Series 700F 10KVA to 150KVA

ULTRA-K Series 600K - he

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

MESP TECHNICAL SPECIFICATION FOR A 1500V DC RECTIFIER TRANSFORMER

Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

SECTION DISTRIBUTION SWITCHBOARDS

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Transcription:

Distribution Transformers Single-Phase Pad-mounted Functional Specification Guide Functional Specification for Single-Phase Pad-Mounted Type Distribution Transformers 5 167 kva 1.0 Scope 1.1 This specification covers the electrical and mechanical characteristics of Eaton s Cooper Power series 5 167 kva Single-Phase Step-Down Pad-Mounted Distribution Transformers. Product is per catalog data CA201002EN. 2.0 Applicable Standards 2.1 All characteristics, definitions, and terminology, except as specifically covered in this specification, shall be in accordance with the latest revision of the following ANSI, IEEE, Department of Energy, and NEMA standards. IEEE Std C57.12.00 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers IEEE Std C57.12.38 - IEEE Standard for Pad-Mounted-Type, Self-Cooled, Single- Phase Distribution Transformers 250kVA and Smaller: High Voltage,,500 GrdY/19920V and Below; Low Voltage, 480/2V and Below IEEE Std C57.12.28 IEEE Standard Pad-Mounted Equipment Enclosure Integrity IEEE Std C57.12.35 IEEE Standard Bar Coding for Distribution Transformers and Step-Voltage Regulators IEEE Std C57.12.90 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers IEEE Std C57. 91 IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators IEEE Std C57.154 IEEE Standard for the Design, Testing, and Application of Liquid- Immersed Distribution, Power, and Regulating Transformers using High- Temperature Insulation Systems and Operating at Elevated Temperatures NEMA TR 1 (R2000) Transformers, Regulators and Reactors, Audible Sound Levels for Liquid-Immersed Power Transformers 1 of 10 April 2016 Supersedes August 2012 (G201-20-1) 2016 Eaton. All Rights Reserved.

3.0 Ratings 10 CFR Part 431 Department of Energy Energy Conservation Program: Energy Conservation Standards for Distribution Transformers; Final Rule. 3.1 The transformer shall be designed in accordance with this specification and shall have an Average Winding Rise (AWR) of one of the following: 65 C, 65/75 C, 75 C The applicable AWR rating shall be specified on the inquiry. 3.2 The transformer shall be designed in accordance with this specification and shall have one of the following kva ratings: 5, 10, 15, 25, 37.5, 50, 75, 100, 167 The applicable kva rating shall be specified on the inquiry. 2 of 10 April 2016 Supersedes August 2012 (G201-20-1)

Table 1 Transformer and Connector High-Voltage Ratings and Electrical Characteristics for deadfront transformers Transformer High-voltage Ratings (V) Single High-Voltage 4160GrdY/20 8320GrdY/4800 12000GrdY/6930 12470GrdY/7200 13200GrdY/7620 13800GrdY/7970 160GrdY/9430 2 22860GrdY/13200 23900GrdY/13800 249GrdY/140 500GrdY/19920 Minimum BIL (kv) 60 75 150 Phase-to- Ground (kv) ( or ) 2 21.1 Electrical Characteristics of the Completely Assembled High-voltage Connectors 1 High-voltage Rating Phase-to-Ground /Phase-to-Phase (kv) ( or /26.3) 2 /26.3 /26.3 /26.3 21.1/36.6 BIL (kv) ( or ) 2 150 60-Hz dry 1 minute withstand (kv) ( or ) 2 50 Series - Multiple High-Voltage 4160GrdY/20 x 12470GrdY/7200 4160Grdy/20 x 13200GrdY/7620 8320GrdY/4800 x 249GrdY/140 12470GrdY/7200 x 249GrdY/140 13200GrdY/7620 x 249GrdY/140 /26.3 /26.3 /26.3 1. For complete connector rating, see IEEE Std 386 2. 2 The required connector rating should be specified The applicable voltage rating and BIL shall be specified on the inquiry. Dual voltage primaries shall utilize an externally operable switch. Unit must be de-energized prior to changing voltages. The applicable multiple voltage rating shall be specified on the inquiry. 3.3 The secondary voltage shall be one of the following. The basic insulation level (BIL) of the secondary voltage shall be 30 kv. 2/120 (3-Bushings) 480/2 (3-Bushings) 120 (2-Bushings) 3 of 10 April 2016 Supersedes August 2012 (G201-20-1)

277 (2-Bushings) 120/2 (4-Bushings Very uncommon for pad-mounted transformers) The applicable secondary voltage shall be specified on the inquiry 3.4 When specified on inquiry, the transformer shall be furnished with full capacity highvoltage taps. The tap-changer shall be clearly labeled to reflect that the transformer must be de-energized before operating the tap-changer. The tap-changer shall be operable on the higher voltage only for transformers with dual voltage primaries. The unit shall have one of the following tap configurations: 4.0 Construction No Taps Two 2 ½% taps above and below rated voltage (split taps) Four 2 ½% taps below rated voltage (four below) NEMA taps (140, 13800, 13200, 12470, ) Non-standard tap configuration The applicable tap configuration shall be specified on the inquiry 4.1 The core and coil shall be vacuum processed to ensure maximum penetration of insulating fluid into the coil insulation system. While under vacuum, the transformer will be filled with preheated filtered degassed insulating fluid. The core shall be manufactured from burr-free, grain-oriented silicon steel and shall be precisely stacked to eliminate gaps in the corner joints. The coil shall be insulated with B-stage, epoxy coated, diamond pattern insulating paper, which shall be thermally cured under pressure to ensure proper bonding of conductor and paper. 4.2 The dielectric coolant shall be listed less-flammable fluid meeting the requirements of National Electrical Code Section 450-23 and the requirements of the National Electrical Safety Code (IEEE Std C2-2002 standard), Section 15. The dielectric coolant shall be non-toxic*, non-bioaccumulating and be readily and completely biodegradable per EPA OPPTS 835.3100. The base fluid shall be 100% derived from edible seed oils and food grade performance enhancing additives. The fluid shall not require genetically altered seeds for its base oil. The fluid shall result in zero mortality when tested on trout fry*. The fluid shall be certified to comply with the US EPA Environmental Technology Verification (ETV) requirements, and tested for compatibility with transformer components. The fluid shall be Factory Mutual Approved, UL Classified Dielectric Medium (UL-EOUV) and UL Classified Transformer Fluid (UL-EOVK), Envirotemp FR3 fluid. *Per OECD G.L. 203 4.3 All transformer components shall be certified to comply with industry standards when tested in Envirotemp FR3 fluid. Certified test reports for each transformer component shall be provided upon request. 4 of 10 April 2016 Supersedes August 2012 (G201-20-1)

4.4 In addition to the regular locking provision, all access doors or hood shall be secured by a recessed, captive, penta head bolt that meets the dimensions set forth in Rural Utilities Service (RUS) Drawing A3759 or IEEE C57.12.38. 4.5 The transformer shall be of sealed tank construction of sufficient strength to withstand a pressure of 7 psig without permanent distortion, and 15 psig without rupturing or affecting cabinet security. 4.6 The exterior of the unit shall be painted Munsell 7GY3.29/1.5 green unless otherwise specified. 4.7 The tank shall include a pressure relief device as a means to relieve pressure in excess of pressure resulting from normal operation. The venting and sealing characteristics shall be as follows: Cracking pressure: 10psig ± 2psig Resealing pressure: 6psig minimum Zero leakage from reseal pressure to -8psig Flow at 15 psig: 35 SCFM minimum 4.8 The tank shall be complete with an anodized aluminum laser engraved nameplate. Nameplate shall conform to IEEE Std C57.12.00, nameplate A. 4.9 High Voltage Bushings and Terminals 4.9.1 The high voltage bushings provided shall be externally clamped bushing wells. These wells shall be removable to allow for field replacement of the bushings without opening the tank. 4.9.2 The bushing configuration shall be per IEEE C57.12.38 Figure 1 (15 & 25 kv Class) and Figure 2 (35 kv Class) for ANSI Type I units, or per Figure 3 (15 & 25 kv Class) and Figure 4 (35 kv Class) for ANSI Type II units, or Eaton s Cooper Power series unique Shrub Plus configuration which offers an ANSI Type I high voltage bushing configuration and ANSI Type II low voltage bushing configuration. The applicable bushing configuration shall be specified on the inquiry. 4.9.3 A cable accessory parking stand shall be provided and shall be located such that the separable insulated connectors that are designed for operation after the transformer is in place can be operated with hot-line tools. 4.10 Low Voltage Bushings and Terminals 4.10.1 The configuration of the secondary bushings shall be per IEEE C57.12.38 Figure 1 (This specifies a horizontal or ANSI Type I bushing arrangement) or Figure 3 (This specifies an angled or ANSI Type II bushing pattern), or Eaton s Cooper Power series unique Shrub Plus configuration which offers an 5 of 10 April 2016 Supersedes August 2012 (G201-20-1)

ANSI Type I high voltage bushing configuration and ANSI Type II low voltage bushing configuration. These bushings shall be removable to allow for field replacement without opening the tank. The applicable bushing configuration shall be specified on the inquiry. 4.10.2 Transformer shall have threaded stud-type line and neutral terminals per Tables 2 and 3 below. Table 2 Stud-type line and neutral terminals LV bushing stud sizes Thread size Note 2 Minimum L Note1/Note 2 0.62-11 UNC-2A 31.75 (1.25) 1.000-14 UNS-2A 44.45 (1.75) 1.250-12 UNF-2A 63.5 (2.5) NOTE 1 Dimension L is in millimeters. Dimensions in parentheses are in inches. The tolerance is ±2mm (0.079 in). NOTE 2 Dimension L shall be the length of threads prior to any jam nuts, ground straps, or secondary connectors. Longer stud lengths may be required for user-supplied secondary connectors. Larger thread size or length, or both, may be required if materials other than copper are used. Stud thread sizes are in inches only Table 3 Transformer kva size 120 120/208Y Required stud size for LV rating of: 2 2/120 120/2 277 480 480/2 2/480 10 0.625-11 0.625-11 0.625-11 0.625-11 15 0.625-11 0.625-11 0.625-11 0.625-11 25 0.625-11 0.625-11 0.625-11 0.625-11 37.5 0.625-11 0.625-11 0.625-11 0.625-11 50 1.00-14 0.625-11 0.625-11 0.625-11 75 1.00-14 0.625-11 0.625-11 0.625-11 100 1.00-14 1.00-14 0.625-11 0.625-11 167 1.250-12 1.00-14 1.00-14 0.625-11 NOTE 1 Dimension L is in millimeters. Dimensions in parentheses are in inches. The tolerance is ±2mm (0.079 in). NOTE 2 Dimension L shall be the length of threads prior to any jam nuts, ground straps, or secondary connectors. Longer stud lengths may be required for user-supplied secondary connectors. Larger thread size or length, or both, may be required if materials other than copper are used. Stud thread sizes are in inches only 6 of 10 April 2016 Supersedes August 2012 (G201-20-1)

4.11 Overcurrent Protection 4.11.1 The protection scheme provided with the transformer shall consist of the following checked attributes. If for any reason a special protection scheme is required it shall be clearly stated on the inquiry. [ ] Standard Over-current protection shall be provided by a Bay-O-Net expulsion fuse with a flapper valve to minimize oil spillage. The Bay-O-Net assembly shall be used in series with an internally mounted isolation link. [ ] Protected Plus (CLF) Primary overcurrent protection shall be provided by a Bay-O-Net expulsion fuse mounted in series with a partial range under-oil current-limiting fuse such that the maximum interrupting rating is 50,000 A. This fusing scheme eliminates the requirement for the isolation link mounted in series with the Bay-O-Net assembly. [ ] Secondary Protected Plus (Breaker) Secondary over-current and transformer overload protection shall be provided by a breaker installed on the secondary side of the transformer. This breaker shall have the capability to energize and deenergize the secondary service by one hotstick operation. This device shall be used in conjunction with an expulsion fuse on the primary side of the transformer. [ ] Protected Plus (MagneX Interrupter) Primary and secondary over-current and transformer overload protection shall be provided by a breaker installed on the primary side of the transformer. This breaker shall have the capability to energize and de-energize the transformer by one hotstick operation. This device may be used in series with a current-limiting fuse to provide 50,000 A interrupting capability. [ ] MagneX Interrupter [ ] MagneX in series with current limiting fuse [ ] VFI Protected (ANSI I Only) The transformer primary shall include a Vacuum Fault Interrupter (VFI) to offer loop sectionalizing capability. The VFI shall have a maximum interrupting rating of 12,000 A RMS with resettable fault protection through 35 kv. The VFI shall also include a tri-phase electronic breaker control with over 100 minimum trip settings and 5 selectable time current curves. The trip settings and curve shall be as checked below. Trip Setting A (Default settings: 80 A minimum trip, instantaneous trip: off) Time-Current Curve: [ ] EF [ ] TF [ ] KF [ ] F [ ] H 4.12 Overvoltage Protection 4.12.1 The protection scheme provided with the transformer shall consist of the following checked attributes. If a special protection scheme is required it shall be clearly stated on the inquiry. 7 of 10 April 2016 Supersedes August 2012 (G201-20-1)

5.0 Labeling [ ] Standard No overvoltage protection is provided with the transformer. [ ] Primary overvoltage protection shall be provided by an internally mounted, heavy-duty distribution class MOV arrester or externally mounted M.O.V.E. distribution-class MOV elbow arrester. [ ] Internally mounted M.O.V.E. distribution-class MOV elbow arrester (STD when primary OCP is desired) [ ] Externally mounted under-oil VariSTAR surge arrester [ ] Secondary overvoltage protection shall be provided by an externally mounted, high-energy, ANSI approved light-duty distribution-class arrester. [ ] Storm Trapper H.E. (High Energy) low-voltage distribution-class surge arrester 5.1 A temporary bar code label shall be attached to the exterior of the transformer in accordance with IEEE Std C57.12.35. 6.0 Finish Performance Requirements 6.1 The tank coating shall meet all requirements in IEEE Std C57.12.28 including: Crosshatch adhesion Humidity Impact Insulating fluid resistance Ultraviolet accelerated weathering (QUV) Abrasion resistance taber abraser Gravelometer 6.2 The enclosure integrity of the tank and cabinet shall meet the requirements for tamper resistance set forth in IEEE Std C57.12.28 including but not limited to the pry test, pull test, and wire probe test. 7.0 Production Testing 7.1 All units shall be tested for the following: No-Load losses at rated current* Total losses at rated current** Percent Impedance at rated current Excitation current (100% voltage) test 8 of 10 April 2016 Supersedes August 2012 (G201-20-1)

Ratio tests using all tap settings Polarity and phase relation tests Induced potential tests Full wave and reduced wave impulse test *No load losses will be reported at C or 20 C for 75 C AWR units, and 85 C or 20 C for 65 C and 65/75 C AWR units. **Total losses and impedance values will be reported at C for 75 C AWR units, and 85 C for 65 C AWR units. 7.2 The manufacturer shall provide the guaranteed average, no-load, and load losses for the unit when specified. These losses will be subject to the tolerance specified in Table 4. Table 4 Tolerance for Transformer Losses No-Load Losses (%) Total Losses (%) 10 6 7.3 Transformers manufactured for sale in the United States shall conform to efficiency levels for liquid immersed distribution transformers, as specified in the Department of Energy ruling 10 CFR Part 431 Energy Conservation Program: Energy Conservation Standards for Distribution Transformers; Final Rule; April 18, 2013. Manufacturer shall comply with the intent of all regulations set forth in noted ruling. 8.0 Approved Manufacturers 8.1 Eaton s Cooper Power Systems Division 9.0 Accessories 9.1 The following checked accessories shall be provided: [ ] Stainless steel hardware [ ] Stainless steel tank, sill, door [ ] Stainless steel pedestal (bottom 1.5 of tank), sill, door [ ] Stainless steel nameplate [ ] Temporary service entrance (2.25 hole) in the sill [ ] Fault indicator provision [ ] Mounting cleats [ ] Lifting bolts [ ] Tank ground connector [ ] Internal high voltage arrester [ ] Arrester disconnect switch 9 of 10 April 2016 Supersedes August 2012 (G201-20-1)

[ ] ½ drain valve with sampling device [ ] 1 drain valve with sampling device [ ] Bushing wells with removable studs [ ] Load break bushing inserts [ ] Rotatable feed thru load break inserts [ ] 2-position, on/off load break switch [ ] 4-position V-blade load break switch [ ] 4-position T-blade load break switch [ ] Bay-O-Net drip shield [ ] Oil site gauge (glass window with ball float) [ ] Oil level gauge (dial-type) [ ] Thermometer (dial-type) without contacts [ ] Pressure/vacuum gauge (dial-type) [ ] Barrier between high voltage and low voltage [ ] Poly-pad combination shipping/mounting pad (10-75 kva) [ ] Internal fault detector 10.0 Shipping Any additional accessories will be specified on the inquiry. 10.1 The unit shall be banded, blocked, or bolted to a wood pallet or poly-pad. 10.2 When applicable, units shall be double stacked to reduce shipping cost and storage space. 11.0 Data With Proposal 11.1 The following data shall be submitted with the proposal when specified: Core losses Winding losses Percent Impedance 12.0 Service 12.1 The manufacturer of the transformer shall have regional service centers located within 2 hours flight time of each state within all contiguous 48 states. Service personnel shall be factory trained in commissioning and routine service of quoted transformers. 10 of 10 April 2016 Supersedes August 2012 (G201-20-1)