Snap Action Switches Technical Guide

Similar documents
Microswitches Limit switches

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

Characteristics 5 TeSys k contactors and reversing contactors

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Model Number Structure

OMRON MK-I / -S RELAY

PCB relay for DC voltage, polarized, monostable or bistable

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Safety switches with slotted hole lever

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

RU Series Universal Relays

2 or 4 pole changeover contact Plug-in/Faston 187

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

(1,5 modules per pole)

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Position switches FM series

General-purpose Relay

Classification Enclosure rating Contact form Contact material

FM series position switches

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

MT4 Relay. 4 pole telecom/signal relay Through Hole Type (THT) Non-polarized. non-latching 1 coil. Features. Typical applications

Control Stations ø 22

62.22 Copper side view

RJ Series Slim Power Relays

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

48 Series - Relay interface modules A. Features

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Complete units: Mushroom heads ø 22mm

38 Series - Relay interface modules A. Features /

Complete units: Push-buttons ø 22mm

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

TV-15, 30 AMP (1 Form A) Power Relay

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Instantaneous Overcurrent Relay

62 Series - Power relays 16 A. Features / /

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Products Available From

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

40 Series - Miniature P.C.B. Relays A

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Installation and Operational Instructions for ROBA -switch Type 017._00.2

General-purpose Relay

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Complete units: Selector switches ø 22mm

Technical Information General Purpose Relays

PROXIMITY SENSOR TERMINOLOGY

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

No-wear isolation of potentials in terminal block design

DEFENSE LOGISTICS AGENCY DLA LAND AND MARITIME POST OFFICE BOX 3990 COLUMBUS, OH

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Position switches FR series

Order/Technical Support Tel: (800) / FAX: (800) /

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40

Operator Heads: ø 22mm

Components for safety applications

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Electronic Circuit Breaker ESS20-0..

Modular equipment. Presentation, standards. Standard contactors TeSys GC

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Miniature Power Relay MSR

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

20 Series Power Relays

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

Relay interface modules A

Protection components

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

Three-phase monitoring relay CM-PFS

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

RELOG. All-or-nothing Relay

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Lexium integrated drives

Separate units: Blocks

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

TURQUOISE SWITCHES ABS TYPE

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

22/10/2012

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Output of three-phase motors at 50 Hz and 400 V

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Transcription:

These basic principles apply to all our precision switches. The specific characteristics of each model are given in more detail in the relevant production sections. Switch construction Single-pole changeover switch (i.e. 8 161) Push button Case Introduction Our switches are high-precision, snap-action switches and these are a few of the key features which distinguish our switches: -High ratings with small dimensions -Very short travels - Low operating forces -Highly dependable force and travel values - Long life - Large range of actuators for easy adaptation to the most varied applications Return spring Pivot point Blade Terminal NC nº2 Contact mobile Contact fixed Terminal NO nº4 Common terminal C nº1 Electrical function SPDT (C) Normally closed (NC) Normally open (NO) 2 1 2 1 4 1 4 Double-pole changeover switch (i.e. 8 12 0) Case Blade Push button Contact fixed Terminal NO nº Terminal NC nº1 Terminal NO nº4 Contact mobile Terminal NC nº2 Return spring Electrical function SPDT (C) Normally closed (NC) Normally open (NO) 4 1 2 1 2 4 The NO and NC circuits must both be of the same polarity. /104

Mechanical characteristics Terminology - Forces - Positions - Travel OF TTF RF Travel Positions Forces Electrical Position of pushbutton circuit RP Rest position Position of the operating device when no external mechanical force is applied. Also described as "height at rest". PT RP TP OL RLP OF Operating Force Maximum force which must be applied to the operating device to displace the rest position RP to the tripping point TP. TP Tripping point Position of the operating device relative to the fixing point (hole, face) at the moment when the microswitch trips. PT Pre-travel Distance between the rest position RP and the tripping point TP. OT TTF Total travel force Force required to displace the operating device from its rest position RP to its overtravel limit position. (We only specify this value if it is higher than the operating force. When not quoted, it is equal to or less than the operating force). MOF Maximum overtravel force The maximum force which can be applied to the operating device, without damaging it, in the end of travel position where it is in abutment internally or against the face of the case. OL Overtravel limit Position of the operating device when an extreme force has moved it to the effective end of the available travel. OT Overtravel Distance between the tripping point TP and the overtravel limit OL. DT RF Release force Force to which the operating force must be reduced to allow the snap-action mechanism to return to its release position RLP. RLP Release position Position of the operating device at the moment when the snap-action mechanism trips on its return to its original position. DT Differential travel Distance between the tripping point TP and the release position RLP. The reference point for the figures given for travel and forces is a point F situated on the button in the case of a plain microswitch, or, generally, mm in from the end of a plain actuator. The reference point for the positions is one of the fixing holes, unless otherwise indicated. Graphs of forces vs. travel Operating force (external) applied to the operating device depression return Contact force Force after depression: return outward Button movement Contact force /105

Mechanical characteristics Environmental conditions Changeover time This is the time taken by the mobile contact when moving from one fixed contact to another until it becomes fully stable (contact bounce included). This time is a function of the contact gap, the mechanical characteristics of the snap action and the mass of the mobile element. However, thanks to the snap-action mechanisms employed, the time is largely independent of the speed of operation. It is normally less that 20 milliseconds (including bounce times of less than 5 ms). about Bounce time Changeover time Resistance to shocks and vibrations Resistance to impact and vibration depends on the mass of the moving parts and on the forces holding the contacts together. Generally speaking, for a switch without an actuator : - Vibration >10 G 10 at 500 Hz - Impact > 50 G 11 ms 1/2 sine-wave Further information on request. Ambient operating temperature The maximum and minimum temperatures at which the mechanical and electrical characteristics of the switch will remain substantially unaltered. Mechanical durability This is an average value indicating the purely mechanical performance of a switch when not subject to any electrical load. It may be useful for evaluation purposes in cases where the power levels involved are very low and the electrical life is thus close to the mechanical life. Degree of protection Under the IEC 529 or NFC 20010 classification scheme, standards employ an IP code to define the degree or class of protection which electrical equipment provides against access to live components, the entry of solid foreign bodies and ingress of water. Maximum speed and rate of operation Our switches will work at speeds of operation varying over a very wide range : normally from 1 mm/min to 1 ms. The maximum rate of operation with a low electrical load may be as high as 10 operations/second. 1st numeral Protection equipment provides against the entry of solid foreign bodies 0 (not protected) 4 diameter 1 mm 5 protected against dust 6 sealed against dust Protection for persons against access to dangerous parts (not protected) 1 mm Ø wire 1 mm Ø wire 1 mm Ø wire Mounting - Operation To conform to the leakage paths and air gaps in the standard EEC24 - EN/IEC 61058 - EN/IEC 60947: - An insulation pad must be inserted between the switch and the fixing surface if the latter is metal. - Manual operation of a metal actuator must only be carried out with the help of a secondary actuator made of insulating materials. 2nd numeral Protection equipment provides against ingress of water 0 (not protected) 4 splashed water 5 hosed water 6 high-pressure hosed water 7 temporary immersion 8 prolonged immersion The installer must ensure adequate protection against direct contact with the output terminals. Fixing - Screw torque Unless otherwise indicated in the mechanical characteristics table, the torque required for the fixing screws must conform to the following values : Under this classification, our switches come within the following categories : - Plain switches = IP 00 - Protected switches = IP 40 with isolated connection - Sealed switches = IP 66 or IP 67 Ø of fixing screw 2 2.5.5 4 Screw torque maximum 25 5 60 100 150 in cm.n minimum 15 25 40 60 100 /106

Dielectric characteristics Circuit types Current rating This is the current the switch is capable of making and breaking which forms the basis for the life tests. Resistive circuit For a circuit with alternating voltage, this is in phase with the current : Cos ϕ = 1. Thermal rating This is the current the switch will withstand when not being operated, for a temperature rise of not more than 60 C. Switch rating AC voltages: see the current rating. With DC voltages the switch rating is very much dependent on the voltage, the contact gap (CG) and the nature of the load being switched. There is a risk of prolonged or indeed permanent arcing if the following limits are exceeded: τ = L R M Inductive circuit A circuit of this type with direct current is characterised by a time constant. An inductive circuit, with alternating voltage, for example, incorporating a motor (cos ϕ < 1) can cause current surges up to 6 times the normal current. For certain switches, we give electrical endurance curves with L = 5 ms in DC R and cos ϕ = 0.8 in AC. 220 110 48 24 12 Limit of constant current D.C. Resistive load Inductive load L/R = 5 ms EC=0.4 mm CG=0.4 mm EC= mm CG= mm Lamp and capacitance circuit The currents at the time when the circuit is closed are very high in this case, being up to 10 times the nominal figure. 0. 0.5 1 2 5 10 16 For special applications, please enquire. Operating curves These indicate the electrical life of the switches, under standard conditions (20 C, 1 cycle/2 seconds), by showing the number of switching operations which can be performed with given types of load. Number of operations Resistive circuit Inductive circuit Internal resistance This consists of the intrinsic resistance (fixed) of the parts carrying current and the contact resistance (variable). Close to the tripping point and release position, the force holding the contacts together drops considerably and this may cause a rise in internal resistance. Insulation resistance The insulation resistance of the switches is generally greater than 50,000 MΩ measured at 500 V DC. Dielectric strength The dielectric strength of our switches is generally better than: - 1500 volts between live parts and earth - 1000 volts between contacts - 600 volts between contacts for switches whose contact gap is less than 0. mm. Rating in Amps /107

Contact materials Choice of contact material To choose the best material for the contacts there are various factors to be considered: - the current and voltages levels - the type of load - the number of operations - the switching frequency - the environmental conditions. Electrical recommendations Inductive circuits To increase the life of contacts and their DC rating, arcing on opening can be cut down by using the following circuits: - for DC Fast diode V R > 5 x V nominal I nominal > 10 x I winding Contacts for general-purpose use Our switches are normally fitted with silver contacts. These are suitable for the majority of applications and provide the best compromise between electrical performance, thermal performance and life. Contacts for low-power circuits E < 20 V and/or I < 100 ma The contacts used in this case are plated with gold (or a gold alloy) for good reliability even in corrosive atmospheres. A B C D - for DC or AC A- RC circuit across inductor B - RC circuit across switch C (nf) ~100 x I nominal (A) V insulation > V peak R(Ω) ~ load resistance (Ω) C - Varistor circuit across load D - Varistor circuit across switch V > V peak supply P(V.A.) E (J) 100 Contacts for special applications We can supply special contacts suitable for particular applications, such as: - Ag CdO contacts for very high drawn currents, - Cross Bar gold-plated Ag Ni contacts which allow a very wide range of applications to be covered by a single type of switch. Very low power circuits In very low power circuits (I > 1 ma, V 5 V), switching is highly sensitive to environmental conditions (the atmosphere, pollution). If the supply is powerful enough, adding a passive resistor to increase the current broken by the switch to a few milliamps will substantially improve reliability of operation. R - Load resistance C - Very low current load /108

Methods of actuation Direct operation Preferably, force should be directly applied to the device the plunger along its axis for operation. However, the majority of our microswitches will accept skewed operation provided the angle of application is not more than 45. The device used to apply the force must never hamper the travel of the plunger to the tripping point (TP). It must under all circumstances move the plunger through at least 0.5 times the overtravel (OT) quoted. Steps must also be taken to see that it does not cause the overtravel limit (OL) or maximum overtravel force (MOF) quoted to be overrun or exceeded. Standards - Approvals Our switches are designed according to international recommendations (IEC), American standards (UL) and/or European standards (EN). Proof of compliance with these standards and recommendations is demonstrated by: - the manufacturer's declaration of conformity (drafted in accordance with the ISO/IEC 22 guidelines), or - approval granted directly by an accredited body, or by application of the CCA (Cenelec Certification Agreement). More detailed information on the approval for a particular type of microswitch can be obtained on request. Operation by actuator When operation is by a roller lever, force should preferably be applied in the direction shown on the left. + Quality Where the movements involved are fast, the ramp should be so designed as to ensure that the operating device is not subjected to any violent impact or abrupt release. Quality is built into our switches from the initial design stage right through to the point where they are put into action at the customer's premises. All departments of the company are guided by the Quality Manual and the stipulations of the ISO 9000 international standard. The location where the switches are manufactured (the la Plaine works at Valence) holds ISO 9001 certification, guaranteeing a high standard of quality. The 8170 switch as an example An 8 170 4 switch marked with the symbols for the European (according to CCA/MC12) and American approvals it holds. Control procedures Manufacturing quality of our switches is controlled systematically during assembly operations and on final completion. All our products are subjected to a final inspection, either at 100% on important characteristics, or according to the statistical sampling rules of French standards X 06-222 and X 06-02. The quality levels applied, for normal use such as defined in previous paragraphs are for the following defects, according to the standards : - critical fault : NQA : 0.40 - major fault : NQA : 1 - minor fault : NQA : 2.5 Rules and regulations EC directives Our switches are compatible with European Community technical directive (Low Voltage) 7/2 and can be used within the framework of Machinery directive 8/92. Environmental protection The modern concept of protection of the environment is an integral part of the manufacture of our switches, from product design through to packaging. At the customer's request, and for certain ranges of our products which must meet specific needs expressed in the specifications, it is always possible to adapt or create an inspection specification of a standard product. /109