LLC LLC "Innovation engineering centre "Kontur" (IEC "Kontur") RADIO-COMMUNICATION SERVICE TESTER РСТ-430 CERTIFICATE ИТЦК46866.002ПС 2005
ИТЦК46866.002ПС GENERAL GUIDELINES. This certificate certifies the РСТ-430 tester (hereafter referred to as tester ) parameters and specifications guaranteed by the manufacturer..2 The certificate contains the main technical characteristics of the tester and prescribes its operating rules..3 The manufacturer provides after-sales service and repair of the tester..4 Testers conform to the group 2 of GOST 2226-94 requirements for operation conditions..5 Testers are manufactured in climatic version УХЛ4.2 as per GOST 550-69..6 (3.2±2.4) V direct current power supply is required to feed the tester. 2 GENERAL INFORMATION ABOUT TESTER 2. Testers are intended for servicing and repairing communications radio stations with different purposes in the stationary and mobile laboratories (workshops). 2.2 Tester action The tester is a measuring and calculating instrument with following parameters: - clock frequency, MHz 0 - capacity, bit... 8 - program memory capacity, Kbyte. 28 - RAM capacity, Kbyte... 4. 3 KEY SPECIFICATIONS 3. The specifications are shown in the table. Table Characteristic, unit of measurement Output signal frequency range (highfrequency), MHz. Frequency tuning step is KHz. 2 Output voltage setting range (highfrequency), db. (0 db =mw). Voltage installation discrecity is KHz. Parameter 90 20 from -60 to -30 Error limits δ rel = ± 3 0-4 % Δ abs = ± [3 + (U hf dev / 40)], db. 3 Signal frequency deviation (highfrequency), KHz. Deviation setting step is 0. KHz. 4 Output signal frequency range (lowfrequency), KHz. Frequency tuning step is KHz. 5 Output voltage setting range (lowfrequency), V. Voltage setting step is 0 mv. 6 Output voltage distortion factor (lowfrequency), %. 0.2 20 0.02 20 ± Hz 0,02 2 No more than 7 Signal frequency measuring range 90 20 δ rel = ±3 0-4, %. δ rel = ± [5 + 5 (D f / D dev )] %, where D f = 20 KHz is upper value of frequency deviation setting range; D dev is a setpoint value of frequency deviation, KHz. Δ аbs = ± (0,02 + 0,05 U lf dev ), V, where U lf dev is a setpoint value of output voltage, V. 2
(high-frequency), MHz. 8 Signal frequency deviation measuring range (high-frequency), KHz. 0.2 20 9 Output signal power measuring range (high-frequency), W. 0.2 20 0 Signal frequency measuring range Δ аbs = ± Hz (low-frequency), Hz. 20 0 5 Alternating sinusoidal voltage measuring range in the frequency range from 0.02 to 20 KHz, V. 2 Direct voltage measuring range, V. 0.02 5 0.02 20 3 Alternating voltage distortion factor measuring range, %. 00 4 Continuous running time is no more than 8 hours. 5 Tester power consumption is not more than 20 V A. 6 Tester overall dimensions are not more than 270 60 270 mm. 7 Tester mass is not more than 8.0 kg. 8 MTBF is not less than 5000 hours. 9 mean lifetime is not less than 5 years. 20 Tester can be used in 2 hours after repairing. ИТЦК46866.002ПС δ abs =± [5 + 5 (D f / D m )], where D f = 20 KHz is upper value of frequency deviation measuring range; D m is measured frequency deviation, KHz. δ rel = ± [0 + (Р f / Р m )], %, where Р f = 20 W is upper value of output signal power measuring range (high-frequency); Р m is measured output signal power value (highfrequency), W. δ rel = ± [3 + 2 (U f / U m )], %, where U f = 5 V is upper value of alternating voltage measuring range; U m is measured alternating voltage value, V. δ rel = ± [2 + 2 (U f / U m )], %, where U f = 20 V is upper value of direct voltage measuring range; U m is measured direct voltage range, V. In the range from to 50 %: δ rel = ± [5 + 0,5 (DF f / DF m )], %, where DF f = 50 % is upper value of distortion factor measuring range, %; DF m is measured distortion factor value, %. In the range from 50 to 00 % distortion factor is not normalized. 4 COMPLETENESS 4. РСТ-430 tester completeness is in the table 2. Table 2 Name Delivery document Quantity Radio-communication tester РСТ-430 2 AC adapter, output: 5V, А 3 Cable HF 4 Cable LF 5 Stowage box 6 Certificate 7 maintenance manual ИТЦК46866.002 ИТЦК48542.005 ИТЦК48542.006 ИТЦК468976.005 ИТЦК46866.002ПС ИТЦК46866.002РЭ ИТЦК46866.002МП copy 3
ИТЦК46866.002ПС 8 test procedure copy copy 5 PACKING CERTIFICATE Radio-communication service tester РСТ-430 ИТЦК46866.002, works number, is packed in LLC IEC "Kontur" in accordance with circuit ИТЦК468976.002УЧ. Packing Date Packed by 6 ACCEPTANCE CERTIFICATE Radio-communication service tester РСТ-430 ИТЦК46866.002, works number, satisfies the specification requirements ИТЦК46866.002ТУ. Stamp here Release date Responsible for acceptance State verification officer Date of primary check 4
ИТЦК46866.002ПС 7 WARRANTY 7. Manufacturer guarantees that tester satisfies technical requirements ИТЦК46866.002ТУ. 7.2 Warranty period is 2 months after shipping. 7.3 Manufacturer guarantees to repair tester without compensation during warranty period. After warranty period manufacturer will repair tester by agreement. Producer address: Post: 630055, Novosibirsk - 55, LLC "IEC "Kontur" Sales department: Russkaya Street 39 office58. tel.: (383) 333-24-46, 292-8-75. E-mail: kontour@bk.ru 8 RECLAMATIONS 8. In the case of tester fault during warranty period the customer needs to draw up a report and send it to the manufacturer. 8.2 The report must contain the following information: ) product name 2) works number 3) release date 4) date of putting into operation 5) fault description. 5