Conductors and Raceway Design

Similar documents
CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

14 AWG 2 AWG: 600 Volt

CIR (Crush & Impact Resistant) VFD Power Cable

TIGER BRAND MINING CABLES

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

A. Product Description: Stranded conductor insulated wire.

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

Power Cables and their Application

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

MV Power Cable Testing Training

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DLO Flexible Power Cable

5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables

MEDIUM VOLTAGE

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

Underground System Design TADP 547

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Medium Voltage Power Cables

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

Nual Installer s guide for wire and cables

Fault location on power cables. Fault location on power cables

P Low Voltage Catalogue Cables Australia Powering your Project

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

SIMpull THHN, it slips and slides - all with NoLube.

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

METAL CLAD WIRING SYSTEM

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Flexitime! Our flexible cables save you time and money.

SECTION MEDIUM-VOLTAGE CABLES

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

Addison Medium Voltage Cables

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

THHN12STGN500 THHN 12 STR Green 500

THHN2BK2500 THHN 2 STR Black 2500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

GEXOL WORLD CLASS OIL & GAS CABLES

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

Underground System Design TADP 547

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

POWER CSA. Jacket Black sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.

Instrumentation Cables

HELUKABEL UL-LISTED CABLES

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

Module 2 Unit 6, 7, 8

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

Creating. There is one basic question every customer needs to address when creating custom

POWER AND COMMUNICATION CABLES Theory and Applications

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Kerman & Kavian Cable Industries ( KCI )

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

ÖLFLEX 409 P. Heavy duty control cable with PUR jacket

Industrial Automation & Control Cables

MarineLine YOZp 0,6/1 kv

Chapter 6. WIRING SYSTEMS Safe Electrical Design

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

Low Voltage Splices, 1000 V or less

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

EDS LV WAVEFORM MAINS CABLE RATINGS

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

FieldLink MC at 20 x outer diameter Torsion

3 Splices. Splices. 5700A-MT Trifurcating Accessory Kit pg. 302 MT-C pg. 302 MT-E pg. 302

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

Cable Solutions for Servo and Variable Frequency Drives (VFD)

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

Selection table for flat & ribbon cables

Notes 3 Explanatory Information 4-10

CABLES AND BUSBAR SYSTEMS

Industrial Data. Conductor (stranding) Diameter Nom. DCR. Shielding Materials Nom. DCR. Color Code. (2)18 AWG TC Data Pair:

Electrical Standards Division 16

J S C E l e c t r o c a b l e W o r k s, K o l c h u g i n o. Product Catalogue

CUSTOM DESIGN COAXIAL CABLES BY SICAB

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

Contents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12

Transcription:

IEEE Southern Alberta Section, Industrial Applications and Power & Energy Chapter Technical Program Conductors and Raceway Design Blair Sackney, Southwire Canada George Morlidge SMIEEE, Fluor Canada May 12, 2014

Conductors, Cables, and Raceways Appendix A Safety standards for electrical equipment, Canadian Electrical Code, Part II

C22.2 No. 0.3-0909 Test methods for electrical wires and cables Scope This standard describes the apparatus, test methods, and formulas to be used in carrying out the tests and calculations required by CSA electrical wire and cable Standards. d

C22.2 No. 38-14 Thermoset-insulated wires and cables Scope This Standard specifies the requirements for singleconductor and multiple-conductor thermoset-insulatd wires and cables rated 600V, 1000V, 2000V, and 5000V.(tri-national i standard) d)

C22.2 No. 38-14 Thermoset-insulated wires and cables Definition An insulating or jacketing polymeric material which, when cross-linked, will not flow on subsequent heating. Cross-linking is accomplished by either chemically or by radiation. i Example - RW90 XLPE RW90

C22.2 No. 51-09 Armoured Cables Scope This standard specifies requirements for single- and multi-conductor insulated cable having metalic interlocking armour without an overall jacket (Type AC90 or ACG90) or with an overall jacket (Type ACWU90 or ACGWU90) that are intrended for installation in accordance with the CEC Part 1 on systems having a nominal voltage of 600v or less. ACG90 and ACGWU90 apply to multi-conductor insulated cables only.

ACWU90 Construction

AC 90 ACG 90

C22.2 No. 51-09

C22.2 No. 51-09

C22.2 No. 51-09

C22.2 No. 51-09

C22.2 No. 51-09

C68.10-08 08 Shielded power cable for commercial and industrial applications, 5 46 kv Scope This Standard applies to the materials, construction, and testing of one- to four-conductor cross-linked polyethylene or ethylene propylene rubber-insulated shielded power cables, rated 5 to 46 kv, that are used for the distribution of electrical energy under normal conditions of installation and service in indoor, outdoor, aerial, underground, or underwater locations.

HVTECK HVTC

C68.10-08 08 Shielded power cable for commercial and industrial applications, 5 46 kv Definitions See a long list of definitions pertinent to medium voltage power cables such as insulation level etc

C68.10-08 08 A Standard specifying the construction of Shielded Power Cable TOC 4.0 Conductors 5.0 Conductor shield (stress control layer) 6.0 Insulation 7.0 Extruded insulation shields and coverings 8.0 Metallic shielding 9.0 Jackets and metalic and associated covering 10.0 Constructon of specific types of cable 11.0 Cable assembly and fillers 12.0 Cable identification 13.0 Production tests etc

C22.2 No. 75-08 Thermoplastic-insulated insulated wires and cables Scope This Standard specifies the requirements for 600V, single-conductor, thermoplastic-insulated wires and cables,.(tri-national standard). In Canada and the United States, requirements for multi-conductor thermoplastic-insulated and jacketed cables rated 600V are covered in other Standards..

C22.2 No. 75-08 Thermoplastic-insulated insulated wires and cables Definitions PVC a thermoplastic compound whose characteristics constituent is polyvinyl chloride or a copolymer of vinyl chloride and vinyl acetate. (Type TW)

C22.2 No. 75-08 Referenced CSA Standards Referenced CSA Standards CEC Part 1 C22.2 No. 0.3-96 Test methods for electrical wires and cables C22.2 No. 131M89 Type TECK 90 cable C22.2 No. 230 M1988 Tray cables C22.2 No. 239-97 Control and instrument cables C22.2 No. 2556-05 Wire and cable test methods Plus many U.S. and European standards

C22.2 No. 75-08

C22.2 No. 75-08

C22.2 No. 75-08

C22.2 No. 96-13 Portable power cables Scope This standard specifies construction and testing requirements for portable power cables normally used in applications where the cables are subject to frequent flexing and where installation i is in accordance with CSA M421 and/or the CEC Part 1. SHD-GC

C22.2 No. 96-13 Portable power cables Definitions See a long list of definitions pertinent to portable See a long list of definitions pertinent to portable power cables such as mine trailing cables etc

C22.2 No. 96-13 Contents This is an extensive standard that includes much detail on construction and testing of different types of Portable Power Cable. Type GGc

C22.2 No. 123-08 Metal Sheathed Cables Scope This Standard applies to single-conductor and multiconductor Type RA90 and RC90 cables having a maximum temperature rating of 90 degrees C in both dry and wet locations and dintended d for installation i in accordance with the Rules of the CEC Part 1.

C22.2 No. 123-08 Metal Sheathed Cables Definition RA90 an aluminum sheathed cable incorporating a thermoset insulated conductor(s) having 90 degree C temperature rating RC90 a copper sheathed cable incorporating a thermoset insulated conductor(s) having 90 degree C temperature rating

C22.2 No. 123-08 Contents This is an extensive standard that includes much detail on construction and testing of different types of Metal Sheathed Cable.

C22.2 No. 131-07 Type TECK 90 cable Scope This standard applies to single- and multi-conductor Type TECK 90 armoured cable intended for installation in accordance with the rules of the CEC Part 1 on systems having nominal voltages of 5000V and less and having a maximum temperature rating of 90 degrees C in both dry and wet locations.

TECK90 Construction

C22.2 No. 131-07

C22.2 No. 131-07

C22.2 No. 230-0909 Tray Cables Scope This standard applies to single conductor and multiconductor constructions, without metal sheath or armour, suitable for use in cable trays and other applications i when installed in accordance with the CEC Part 1. (a very brief Standard does not include construction details, only references other Standards and includes testing for same)

Tray Cable Construction

C22.2 No. 230-0909 Construction Constructions include types specified in the following Standards: (a) CAN/CSA 22.2 No. 38 Thermoset-insulated wires and cables (b) CSA 22.22 No. 75Thermoplastic-insulated insulated wires and cables (c) CSA 22.2 No. 96 Portable power cables (d) Can/CSA-22.2 No. 239 Control and instrumentation cables; and (e) CSA C68.10 Shielded power cables for commercial and industrial applications 5-46kV

C22.2 No. 230-0909 Tests 5.1 General 5.2 Flame 5.3 Abnormal low temperature impact 5.4 Mechanical damage impact 5.5 Mechanical damage crushing 5.6 Weather resistance 5.7 Oil resistance (optional) 5.8 Explosion on cables with bundled subassemblies

C22.2 No. 239-09 Control and instrumentation cables Scope This Standard applies to multiple-conductor control and instrumentation cables (including thermocouple cables and thermocouple extension cables) having a voltage rating not exceeding 1000V and intended d for installation in accordance with the CEC Part1. Note: The designations for such cables are CIC for unarmoured cables and ACIC for armoured cables.

C22.2 No. 239-09

C22.2 No. 239-09

C22.2 N0. 2556-13 Wire and cable test methods Scope This standard describes the apparatus test methods This standard describes the apparatus, test methods, and formulas to be used in carrying out the tests and calculations required by wire and cable Standards.

C22.2 N0. 2556-13 This Standard is very similar to C22.2 2 No. 0.3-09, Test methods for electrical wires and cables. It is the tri-national equivalent and is referenced in many new Standards instead of C222No C22.2 No. 0.3 03-09.

C22.2 No. 174-M1984 Cables and cable glands for use in hazardous locations Scope This Standard allies to cables and cable glands intended for (a) fixed wiring in Class 1, Groups A, B, C, and D; Class II, Groups E, F, and g; and Class III hazardous locations in accordance with the Roles of the CEC Part 1; and (b) fixed wiring and portable cables in gaseous mines in accordance with the Rules of the CEC Part V; and is in addition to the basic electrical requirements applicable to such cables and cable glands for use in other hazardous locations.

C22.2 No. 174-M1984 Cables and cable glands for use in hazardous locations Scope cont d Note: The requirements of this Standard for cables and cable glands for use in hazardous locations in accordance with the Rules of the CEC, Part 1, are based on the premise that the basic electrical requirements for such cables and cable glands exist in other published CSA documents.

C22.2 No. 174-M1984

C22.2 No. 174-M1984

C22.2 No. 126.1-09

C22.2 No. 126.1-09 Metal cable tray systems Scope This Standard specifies the requirements for metal cable trays and associated fittings designed for use in accordance with the rules of the CEC Part 1, and the National Electrical Code (NEC)

C22.2 No. 126.1-09 Metal cable tray systems Preface This is the common CSA and NEMA Standard for metal cable tray systems. It is the third edition of CSA C22.2 No. 126.1, superseding the previous edition published in 2002 and 1998, and the fifth edition i of NEMA VE 1, superseding the previous edition published in 2002. (CANENA Technical Harmonization committee)

C22.2 No. 126.1-09

Cable Tray Loading

Cable Tray Support

Conductors CEC Section 4 Conductors Section 12 Wiring Methods

Conductors

Conductors

Conductors

Conductors

Conductors

IEEE 835 Table

Conductors

Conductors

Underground Duct Banks

Underground Duct Banks

Underground Duct Banks

Underground Duct Banks

Underground Duct Banks