LEADING THE WAY in Light Measurement Systems

Similar documents
illumia Plus Temperature Controlled Light Measurement Systems

KickStart Instrument Control Software Datasheet

Pulsed Laser Power Measurement Systems

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

SOURCE MEASURE UNITS. Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money

LED Lighting Flux and Color Measurement System (LFC)

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

We bring quality to light. MAS 40 Mini-Array Spectrometer

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Simplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies Making Current-Voltage Measurement Using SMU

Simplifying FET Testing with 2600B System SourceMeter SMU Instruments APPLICATION NOTE

Frame through-beam sensors

Cisco ONS Metropolitan Dense Wavelength Division Multiplexing 100-GHz FlexLayer Filter Solution

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

IESNA standards on LED and SSL: LM-79, LM-80, and future standards

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

Keysight Technologies

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

LED Tester BTS256-LED

Introduction. Part 1. Introduction...2

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Using the Ramp Rate Method for Making Quasistatic C-V Measurements with the 4200A-SCS Parameter Analyzer APPLICATION NOTE

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

Introduction. Part 1. Introduction...2

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

Solid State Luminance Standards

Using the 4200A-CVIV Multi-Switch to Make High Voltage and High Current C-V Measurements APPLICATION NOTE

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Measurement Statistics, Histograms and Trend Plot Analysis Modes

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Measuring CNT FETs and CNT SETs Using the Agilent B1500A

We bring quality to light. CAS 120 CCD Array Spectrometer

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

Trouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL

Stress Calibration for Jitter >1UI A Practical Method

Performing Safe Operating Area Analysis on MOSFETs and Other Switching Devices with an Oscilloscope APPLICATION NOTE

JETI Specbos Instruments

Through-beam ring sensors

WOODWORKING TECHNOLOGY IN EUROPE: HIGHLIGHTS European Federation of Woodworking Technology Manufacturers

BenchTop Extraction Arms with unbeatable flexibility

LED14.5WPAR30S/FL/827-DIM

Table of Contents Executive Summary 29

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Spectroradiometer specbos 1201

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

Keysight Technologies N4985A System Amplifiers

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

The compact test- disconnect terminal interface system for protection and secondary technology

Isolation Addresses Common Sources of Differential Measurement Error

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

Who Reads and Who Follows? What analytics tell us about the audience of academic blogging Chris Prosser Politics in

Keysight Technologies Resistance Measurements Using the B2900A Series of SMUs

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

specification display & lighting hera spectrometer

Keysight Technologies N9310A RF Signal Generator

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Creating the world technology leader in surface solutions under one roof

Photometric Test Report

In-circuit Measurements of Inductors and Transformers in Switch Mode Power Supplies APPLICATION NOTE

BTS2048-VL-CP-ILED-B-IS-1.0-HL

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

NI sbrio-9632/9642 Verification Procedure

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

STAINLESS STEEL STAINLESS STEEL MANUFACTURING STAINLESS STEEL TRADING BRIGHT BARS WIRES PRECISION COMPONENTS

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Time and Frequency Measurements for Oscillator Manufacturers

Keysight Technologies E1834E/G/J/M/Z Mounted Beam Delivery Optics. Preliminary Data Sheet

Broadbandradiometer specbos 1211

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

LM Test. for LED. Cabinet

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Transcription:

LEADING THE WAY in Light Measurement Systems LIGHT MEASUREMENT SYSTEMS THERMAL CONTROL SYSTEMS WIDE DYNAMIC RANGE SPECTROMETERS www.labsphere.com/illumia SOLUTION BASED PROFESSIONAL SOFTWARE

Welcome to Labsphere! This Product Guide is intended to give you an introduction and overview of Labsphere light measurement products and services. Labsphere s Light Measurement Systems offer a turn-key solution for R&D, production and quality assurance. They feature systems with the highest accuracy and dynamic range available today. Labsphere offers three Light Measurement Series illumia lite illumia illumia pro We invite you to visit our website at www.labsphere.com to view detailed data sheets for each product as well as our online library of technical articles and application notes. We look forward to earning your business! HISTORY Since 1894, when Richard Ulbricht built the first working integrating sphere, the integrating sphere photometer has been used to measure the total luminous flux of light sources. Today, the name Labsphere has become synonymous with the integrating sphere while, total radiant flux, luminous flux, and associated color parameters are measured and applied for the determination of lamp lumen efficacy, color rendering, appearance, optical performance and quality. With applications that include test and calibration in general lighting, automotive lighting, fiber illuminators, LCD backlighting, solid state lighting, LEDs, architectural lighting, lasers and laser diodes, Labsphere integrating sphere photometers, radiometers and spectrometers have become a staple tool in light test labs and industry throughout the world. Labsphere light measurement systems are designed to minimize spatial distribution sensitivity associated with directional and divergent light sources and provide easy to use systems designed in concert with industry measurement standards. Labsphere has created thousands of light measurement systems from universal bench top applications to fully integrated automated production line systems with customers ranging from universities and innovative start ups to the world leaders in general and automotive lighting industry and government organizations. Our customers rely upon our extensive knowledge and experience to provide high-end products that address their specific requirements.

ILLUMIA illumia Light Measurement Systems are designed to minimize spatial distribution sensitivity associated with directional and divergent light sources and provide easy- to-use systems designed in concert with industry measurement standards. All systems are certified by our calibration laboratory team with extensive experience in performing application specific calibrations, all of which are traceable to the National Institute of Standards and Technologies (NIST). Labsphere s Spectraflect sphere coating is a proprietary, high-reflectance coating that is useful over a wide wavelength range. This non-toxic material is near-lambertian in character and easily applied by spray to any substrate. Spectraflect is a specially formulated barium sulfate coating which produces a nearly perfect diffuse reflectance surface. Spectraflect is generally used as a reflectance coating in the UV-VIS-NIR region and is most effective over the wavelength range from 300 to 2400 nm. The range can be stretched to 185 nm before binder absorption peaks begin to appear. The coating is opaque with reflectance up to 98% over the wavelength range from 400 to 1100 nm. Spectraflect is thermally stable to approximately 100 C. illumia Light Measurement Systems are easily customized with a choice of three high-speed spectrometer series and a variety of interchangeable light measurement accessories. Achieve spectral results in milliseconds and conform to national standard measurement geometries. FEATURES INCLUDE: Wide Dynamic Range which Allows a Single Sphere to Measure a Wide Range of Light Levels NIST Traceable Standards for In-house Recalibration Spectral Results in Milliseconds Spectraflect Interior Sphere Coating Conforms to National Standard Measurement Geometries MEASURE: Total Spectral Flux Luminous Flux Radiant Flux Chromaticity CCT & CRI Peak Wavelength Dominant Wavelength I, V and Luminous Efficacy And Many More Measurements *NVLAP is in full conformance with the standards of the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC), including ISO/IEC 17025 and Guide 58.

illumia lite illumia 600/610 illumia 1100/2100 illumia 30x0 illumia pro 500 see brochure for product details see brochure for product details Luminous Flux Measurement 3 3 3 3 3 Spectral Measurements 3 3 3 3 3 Accuracy at Lower Light Levels ++ ++ +++ +++ ++ Sphere Sizes 25cm dia to 3m dia 3 3 3 3 Absorption Correction Lamps 3 3 3 3 3 Calibration Lamps 3 3 3 3 Dynamic Range ++ + ++ +++** + Single Scan Dynamic Range ++ + ++ +++ + Low Stray Light + ++ +++ +++ ++* Continuous Measurements + + + +++ ++ Speed of Minimum Exposure Time +++ +++ + ++ +++ Sensitivity + ++ + +++ ++ Maximum Exposure Time + + +++ ++ + Low Level Light Measurement ++ + +++ +++ + Stability for Long Integration Times @ Low Light Levels ++ + ++ +++ + Shutter 3 3 Temperature Controller Active Device Temperature Control 3 Temperature Sweeps 3 Voltage Sweeps 3 Current Sweeps 3 Soak Time Triggering 3 Performance Incandescent lamps +++ +++ +++ +++ +++ HID / CFL Lamps + +++ +++ + Low Level Sources + + +++ +++ + Blue LEDs + ++ +++ +++ ++* White LEDs ++ ++ +++ +++ ++* Customization Options Customized Ports / Baffles 3 3 3 3 3 Rotation Systems 3 3 3 3 Ambient Temp. Controlled Systems 3 3 3 3 Software Options MtrX-SPEC 3 3 3 3 illumia pro Software 3 Standards LM-79 3 3 3 3 * with stray light correction software ** with ND filters www.labsphere.com/illumia

SPECTROMETERS SMS-500/510 The highly sensitive SMS-500 and SMS-510 Mini CCD Array Spectrometers offer low noise and a broad spectral response with calibrated ranges from 360 to 1000nm or 300 to 1050nm. Within the illumia pro Thermal Measurement System, the spectrometers avoid the inherent photometric errors associated with filter-based photometers. Data is accurate even for narrow-band light sources such as LEDs, fluorescent lamps, and discharge lamps. The Labsphere SMS-5x0 CCD Array Spectrometers are multi-channeled spectral analyzers designed for real-time spectral analysis. Instantaneous spectral acquisition provides the radiometric, photometric, and color characteristics of the device under test (DUT). Fast results help to increase the rate of product development, decrease the time to market, and reduce development costs. KEITHLEY KEITHLEY 2400 SERIES SOURCEMETER OPTIONS We are pleased to offer the Keithley 2400 Series SourceMeters for optimum operation of the illumia pro systems. Our sales engineers can assist you in choosing the right model for your application. The Keithley SourceMeter is a required component for operating the illumia pro systems. For user convenience, the instrument can be supplied by the user and sent to Labsphere for integration into the electronics rack, or it may be purchased directly from Labsphere. * TEC - THERMAL ELEMENT FEATURES: Complete Thermal, Optical & Electrical Analysis Automated Data Acquisition & Analysis TEC Temperature Control and Monitoring Measure Optical Properties as a Function of Temperature and Operating Current Available in 20, 40, 65 and 76 inch Sphere Diameters Conforms to IESNA LM-79 & LM-80 Ambient Air Temperature Control Available Labsphere s illumia pro Thermal, Optical, Electrical Characterization Systems allow users to quickly, accurately and simultaneously measure the optical and thermal characteristics of various LEDs and arrays. LED manufacturers, integrators and users are paying more attention to the thermal and electrical characteristics of LEDs because thermal variances at the junction can affect an LED s performance in terms of color, output, life expectancy, luminous efficacy and linearity performance. MEASURE: Electrical: I, V, Electrical Watts Optical: Flux, Color, Luminous Efficiency Thermal: Case Temperature Control vs. Electrical and Optical Parameters APPLICATIONS: Packaged LEDs Modules & Arrays Backlight Displays Solid State Lighting MEASUREMENT FUNCTIONS: ILV @ constant T: step & control I, stabilize T, measure L & V VLI @ constant T: step & control V, stabilize T, measure L & I TLV @ constant I: step & control T, stabilize T, measure L & V TLI @ constant V: step & control T, stabilize T, measure L & I ILV/T: perform ILV @ constant T, step T and repeat at each T VLI/T: perform VLI @ constant T, step T and repeat at each T Key: L = Lumens V = Voltage I = Current T = Temperature * Keithley and the Keithley logo are registered trademarks of Keithley Instruments Inc. All rights reserved.

LAMPS Auxiliary Lamps for Absorption Correction Industry standards and Labsphere recommend applying absorption correction techniques. Self-absorption correction is critical, since the physical size and shape of SSL products and lamps under test are typically very different from the reference lamp size and shape. The use of an absorption correction lamp can correct for self-absorption errors. Lamp assemblies mount onto a Labsphere 1-inch port frame and auxiliary lamp port on our Light Measurement Spheres with no modifications required. Calibrated Lamp Standards Labsphere s Total Spectral and Total Luminous Flux Lamp Standards are selected for their stability and reproducibility. Each lamp has been carefully screened, seasoned and calibrated at our Optical Calibration Laboratory under the guidelines recommended by the IESNA (Illuminating Engineering Society of North America) to provide the highest degree of accuracy. A calibration certificate verifying traceability to NIST is provided with each lamp. Calibrated Forward Flux Standards Labsphere s Lamp Standards of Total Spectral Flux provide an exceptional artifact for calibrating integrating sphere spectrometers for total spectral radiant flux responsivity from 350 to 1050 nm. Labsphere s Lamp Standards of Forward Spectral Flux are selected for their stability and reproducibility. The selected lamps are then calibrated directly to the NIST lumen, for a calibration result you can rely on. SOFTWARE Sold Separately illumia pro software provides a powerful, yet easy-touse menu driven operating environment. It allows users to control the LED temperature and operating current at specified ranges. This control enables the software to measure and characterize the device under test (DUT) over a wide range of temperatures. AGILENT Agilent A3634A Programmable DC Power Supply System software automates procedures for measuring the spectral characteristics and controlling current and temperature. Software simultaneously collects electrical, optical and thermal data which is graphed and viewed on screen or can be exported to Excel format for further analysis. SOFTWARE OPERATING ENVIRONMENT Windows XP, 7-32 bit operating systems This single output power supply gives you the flexibility to select from a dual output range. Therefore you can drive the calibration lamp and the auxiliary correction lamp from one power supply. The output load is protected against overvoltage and overcurrent, which is easily monitored and adjusted from the front panel and illumia pro software. * Agilent and the Agilent logo are registered trademarks of Agilent Technologies Inc. All rights reserved.

Model Number: Part Number: illumia pro 500-050 AA-80510-050 illumia pro 500-100 AA-80510-100 illumia pro 500-165 AA-80510-165 illumia pro 500-195 AA-80510-195 SYSTEM SPECIFICATION SPHERE Sphere Size (m) Sphere Assembly Frame Style Sphere Coating Reflectance Radiometric Range of Coating TE Mounting Plate 2 Pi/TEC Port Size (mm) Sphere Assembly Dim. (WxHxD) (m) Recommended Lamp Size (LM-79) MAX Lamp Wattage SPECTROMETER Detector Spectral Range (spectrograph) Spectral Range (calibrated) Resolution Integration Time Cooling TE Temp Drift Linearity Wavelength Accuracy Performance (lumens) QTH CW WW Blue Red Average % Noise on 100% Line Stray Light (Y-50 filter) Stray Light LED/Laser Focal Length Optical Input Dynamic Range (single scan) Average Spectral Sample Interval Blaze Wavelength of Grating Peak Responsively Wavelength x, y Chromaticity Accuracy Software Stray Light Correction Mechanical Shutter AD Converter PC Interface Trigger: hardware Trigger: software 0.5 H Frame 97-98% @600nm 350-2499nm 76.2mm diameter 152 0.73x0.74x0.46 <0.07m diameter, <0.33m l Ambient temp. 100C SMS-500 2048 element Linear CCD 1.4nm 1.1ms - 4 sec +/-0.3% <+/- 0.3 nm Min Max 0.192 11369 0.42 4380 0.344 6185 0.354 446 0.412 1186 0.23% 39.0% (5.78% for ULS) 3.4E04-450-550nm 75mm 600um, 2m long 436.7 1nm 500nm 475nm <0.001 for x, y No 16 bit USB 2.0 1. Stray light (Y-50 filter) is the average reported transmittance from 360470nm trough a 500nm cut on filter 1.00 H Frame 97-98% @600nm 350-2499nm 76.2mm diameter 330 1.28x1.75x0.90 <0.14m diameter, <0.67m l Ambient temp. 100C SMS-500 2048 element Linear CCD 1.4nm 1.1ms - 4 sec +/-0.3% <+/- 0.3 nm Min Max 0.768 14875 1.68 9904 1.376 11924 1.416 1054 1.648 1573 0.23% 39.0% (5.78% for ULS) 3.4E04 from 450-550nm 75mm 600um, 2m long 436.7 1nm 500nm 475nm <0.001 for x, y No 16 bit USB 2.0 1.65 H Frame on rails 97-98% @600nm 350-2499nm 76.2mm diameter 533 1.96x2.14x1.83-2.85 <0.23m diameter, <1.10m l Ambient temp. 100C SMS-500 2048 element Linear CCD 1.4nm 1.1ms - 4 sec +/-0.3% <+/- 0.3 nm Min Max 2.08 73222 4.58 56691 3.74 67318 3.84 3044 4.48 7996 0.23% 39.0% (5.78% for ULS) 3.4E04 from 450-550nm 75mm 600um, 2m long 436.7 1nm 500nm 475nm <0.001 for x, y No 16 bit USB 2.0 1.95 H Frame on rails 97-98% @600nm 350-2499nm 76.2mm dia. 635 2.20x2.33x1.88-2.85 <0.27m dia., <1.3m l Ambient temp. 100C SMS-500 2048 element Linear CCD 1.4nm 1.1ms - 4 sec +/-0.3% <+/- 0.3 nm Min Max 2.912 102265 6.412 79177 5.236 94019 5.376 4252 6.272 11186 0.23% 39.0% (5.78%/ULS) 3.4E04-450-550nm 75mm 600um, 2m long 436.7 1nm 500nm 475nm <0.001 for x, y No 16 bit USB 2.0

Labsphere Locations and Dealers Around the Globe: North America South America Europe Africa & Middle East Asia/Pacific Canada Mexico United States Brazil Colombia Austria Belgium Denmark Finland France Germany Greece Hungary Ireland Italy Luxembourg Netherlands Norway Poland Portugal Russia Spain Sweden Switzerland Turkey United Kingdom Egypt Israel Saudi Arabia South Africa Australia China Hong Kong India Indonesia Japan Korea Malaysia New Zealand Russia Singapore Taiwan Thailand Turkey 231 Shaker Street North Sutton New Hampshire 03260 USA Phone: +1.603.927.4266 Fax: +1.603.927.4694 www.labsphere.com