Thermography. White Paper: Understanding Infrared Camera Thermal Image Quality

Similar documents
Understanding Infrared Camera Thermal Image Quality

High-performance MCT Sensors for Demanding Applications

Microbolometers for Infrared Imaging and the 2012 Student Infrared Imaging Competition

Development of a shutterless calibration process for microbolometer-based infrared measurement systems

Use of infrared thermography in electronics

LWIR NUC Using an Uncooled Microbolometer Camera

Testo SuperResolution the patent-pending technology for high-resolution thermal images

SMALL UNMANNED AERIAL VEHICLES AND OPTICAL GAS IMAGING

Large format 17µm high-end VOx µ-bolometer infrared detector

Enhanced LWIR NUC Using an Uncooled Microbolometer Camera

High Resolution 640 x um Pitch InSb Detector

Detection of the mm-wave radiation using a low-cost LWIR microbolometer camera from a multiplied Schottky diode based source

Chapters 1-3. Chapter 1: Introduction and applications of photogrammetry Chapter 2: Electro-magnetic radiation. Chapter 3: Basic optics

IR WINDOW TRANSMISSION GUIDEBOOK. Copyright CorDEX Instruments Ltd. ID 4015 Rev A

WHITE PAPER MINIATURIZED HYPERSPECTRAL CAMERA FOR THE INFRARED MOLECULAR FINGERPRINT REGION

Background. Chapter Introduction to bolometers

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

DESIGN NOTE: DIFFRACTION EFFECTS

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

Chapters 1-3. Chapter 1: Introduction and applications of photogrammetry Chapter 2: Electro-magnetic radiation. Chapter 3: Basic optics

CHAPTER 7. Components of Optical Instruments

Digital Imaging Rochester Institute of Technology

High Dynamic Range Imaging using FAST-IR imagery

Compact Dual Field-of-View Telescope for Small Satellite Payloads

OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

Photons and solid state detection

Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors

Improving the Collection Efficiency of Raman Scattering

Low-Cost Far-Infrared FPA based on High-Volume Pressure Sensor Process

Novel laser power sensor improves process control

SR-80 EXTENDED AREA BLACKBODY

PRODUCT OVERVIEW FOR THE. Corona 350 II FLIR SYSTEMS POLYTECH AB

Fluke TiR Series Thermal Imagers

746A27 Remote Sensing and GIS. Multi spectral, thermal and hyper spectral sensing and usage

A Low-Cost Thermal Imaging Sensor for Military Dismounted Operations

Computer simulator for training operators of thermal cameras

Design of Infrared Wavelength-Selective Microbolometers using Planar Multimode Detectors

IMAGE FORMATION. Light source properties. Sensor characteristics Surface. Surface reflectance properties. Optics

Technical Note How to Compensate Lateral Chromatic Aberration

See more with the thermal imager testo 880

Digital camera. Sensor. Memory card. Circuit board

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Detection Beyond 100µm Photon detectors no longer work ("shallow", i.e. low excitation energy, impurities only go out to equivalent of

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

Synchronized electronic shutter system (SESS) for thermal nondestructive evaluation Joseph N. Zalameda

CHARACTERISTICS OF REMOTELY SENSED IMAGERY. Radiometric Resolution

IR Laser Illuminators

Sensitivity Enhancement of Bimaterial MOEMS Thermal Imaging Sensor Array using 2-λ readout

Towards lower Uncooled IR-FPA system integration cost

What professionals look for in an infrared camera

TAMARISK INFRARED SOLUTIONS THAT FIT

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

Determining MTF with a Slant Edge Target ABSTRACT AND INTRODUCTION

High resolution images obtained with uncooled microbolometer J. Sadi 1, A. Crastes 2

X-SCOPE Ultra large FOV micro video colorimeter

EC-433 Digital Image Processing

Chapter 2: Digital Image Fundamentals. Digital image processing is based on. Mathematical and probabilistic models Human intuition and analysis

Be aware that there is no universal notation for the various quantities.

Stop Guessing, Start Seeing

Mercury Cadmium Telluride Detectors

Exercise questions for Machine vision

Uncooled microbolometer detector: recent developments at ULIS

Tunable wideband infrared detector array for global space awareness

Εισαγωγική στην Οπτική Απεικόνιση

Components of Optical Instruments

Lecture 9. Lecture 9. t (min)

AST Lab exercise: CCD

CPSC 4040/6040 Computer Graphics Images. Joshua Levine

ICU News Flash. ICU consortium. Infrared Imaging Components for Use in Automotive Safety Applications (ICU)

DIGITAL CAMERA SENSORS

The first uncooled (no thermal) MWIR FPA monolithically integrated with a Si-CMOS ROIC: a 80x80 VPD PbSe FPA

Based on lectures by Bernhard Brandl

Design and characterization of 1.1 micron pixel image sensor with high near infrared quantum efficiency

DEFENSE APPLICATIONS IN HYPERSPECTRAL REMOTE SENSING

Digital Image Processing

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

Evaluation of infrared collimators for testing thermal imaging systems

Camera Overview. Olympus Digital Cameras for Materials Science Applications: For Clear and Precise Image Analysis. Digital Cameras for Microscopy

This document explains the reasons behind this phenomenon and describes how to overcome it.

The Noise about Noise

FLIR K2. FLIR-DIRECT.ca

GPI INSTRUMENT PAGES

Lens Aperture. South Pasadena High School Final Exam Study Guide- 1 st Semester Photo ½. Study Guide Topics that will be on the Final Exam

Material analysis by infrared mapping: A case study using a multilayer

Challenges in Imaging, Sensors, and Signal Processing

A 3 Mpixel ROIC with 10 m Pixel Pitch and 120 Hz Frame Rate Digital Output

ECEN 4606, UNDERGRADUATE OPTICS LAB

Light gathering Power: Magnification with eyepiece:

PolarCam and Advanced Applications

Infrared Detectors an overview

Low-Power Ovenization of Fused Silica Resonators for Temperature-Stable Oscillators

Low-cost Approach for Far-Infrared Sensor Arrays for Hot-spot Detection in Automotive Night Vision Systems.

9/19/16. A Closer Look. Danae Wolfe. What We ll Cover. Basics of photography & your camera. Technical. Macro & close-up techniques.

Making NDVI Images using the Sony F717 Nightshot Digital Camera and IR Filters and Software Created for Interpreting Digital Images.

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

IPD3. Imaging Photon Detector APPLICATIONS KEY ATTRIBUTES

3/5/17. Detector Basics. Quantum Efficiency (QE) and Spectral Response. Quantum Efficiency (QE) and Spectral Response

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

Overview. Pinhole camera model Projective geometry Vanishing points and lines Projection matrix Cameras with Lenses Color Digital image

Receiver Design for Passive Millimeter Wave (PMMW) Imaging

Transcription:

Electrophysics Resource Center: White Paper: Understanding Infrared Camera 373E Route 46, Fairfield, NJ 07004 Phone: 973-882-0211 Fax: 973-882-0997 www.electrophysics.com

Understanding Infared Camera Electrophysics Resource Center: Understanding Thermal Camera Image Quality Abstract You ve no doubt purchased a digital camera sometime over the past few years to replace your old film camera. It s likely your purchased was influenced by your belief that the number of pixels was the most important specification when trying to judge image quality between all the camera choices offered. For anyone that reads Consumers Reports and their detailed evaluation of digital cameras you ll appreciate that camera performance includes careful analysis of much more than the pixel count. Because a thermal camera is basically an image converter (radiant thermal energy to visible image) you need to understand only a few attributes that determine thermal image quality; resolution, thermal sensitivity and fixed pattern noise. Often thermal camera brochures offer list specification that you, as a user, may never be able to confirm or even understand. This paper s objective is to help you simplify your understanding of how image quality is determined. We will cover three topics that directly influence thermal image quality and discuss a number of related topics as well. Topics: Pixel resolution Thermal sensitivity Non-uniformity correction Pixel Resolution The first consideration is the number of pixels. Today there are three resolution standards (some manufacturers cameras deviate slightly): Low Resolution 160x120 (19,600 pixels) Medium Resolution 320x240 (76,800 pixels) High Resolution 640x480 (307,200 pixels) How much resolution you need (verses want) is primarily determined by your application and by the value you give to image quality. When evaluating a digital camera with 5 verses 10 mega pixels most users will never benefit by purchasing a camera with 10 million pixels because they will never print the images on large enough paper where the resolution would provide better print quality. Whereas you will always print and display the full resolution of an infrared camera since the highest resolution available is relatively modest by today s digital camera standards. Even at 640x480 pixel resolution a high definition thermal image will only take up a fraction of today s computer displays and the resulting 2 2008 Electrophysics Corp. All rights reserved.

Electrophysics Resource Center: Understanding Camera thermal image print quality will always be fully realized. Therefore when evaluating a thermal camera the number of pixel is relevant and increased resolution is the most significant consideration in improving image quality. 160x120 320x240 640x480 160x120 (4X) 320x240 (4X) 640x480 (4X) Another benefit to high resolution is the ability to zoom into a scene and maintain good image quality. The majority of thermal cameras feature a standard optic with a horizontal fi eld of view of approximately 25. Regardless of pixel resolution the performance of a 640x480 camera set to 2X digital zoom is going to equal the performance of a 320x240 resolution camera with an optional (and often costly) 12 (2X) lens. If you anticipate the need for imaging objects at distances further than 20 feet you should consider the increased costs of a 2X lens for a 320x240 thermal camera when comparing the total costs between 320x240 and 640x480 systems. An ISO 9001:2000 Certified Company UKAS #7096 - ANAB #A060693 3

Understanding Infared Camera Electrophysics Resource Center: The second major issue that impacts image quality is thermal sensitivity. While there are a number of tests used to quantify this specification, thermal sensitivity basically defines how well the camera will image as you increase image contrast. Thermal sensitivity varies with object temperature, as object temperature increases the slope of the signal output of the detector increases with increased temperature. This means that the signal (increasing) to noise (fixed) ratio improves as you view hotter objects. However this is not usually a benefi t because the applications where better thermal sensitivity can be exploited are low temperature (room temperature) applications where the thermal contrast (temperature delta within an image) is very low. Typical low thermal contrast applications include building diagnosis where the camera is imaging interior walls with very little temperature variations or emissivity differences and issues like moisture or insulation quality can only be visualized by increasing the contrast to the point where the cameras thermal sensitivity limits the useful temperature span settings. As you review published camera specifications you will see thermal sensitivity specifications range between 0.25 C (250mK) and 0.05 C (50mK). While you might consider a quarter of degree to be adequate thermal sensitivity as soon as you look at a low contrast scene you ll discover the image quality adversely effects the image quality as noise begins to dominate the image. Thermal imagers usually display images in palettes comprised of 256 discreet color or gray levels. Imagine your target has a temperature difference between 0 C and 256 C each gray or color level would represent 1 degree of temperature difference. Now apply this same color mapping into a scene with temperatures between 25 C and 35 C or 10 degrees. Each color now represents 0.03 C (10 C 256), a value lower than the most sensitive uncooled cameras. The result is some display of noise. There are many applications in which it is very important to set the span as narrow as possible in order to see the smallest temperature variations possible. If you are using a camera with 0.25 C sensitivity and wanted to maintain the same level of noise you would have to set a temperature range of 65 C (150 F) which would likely result in a very low contrast image. You should recognize that the difference between a camera with 50mK sensitivity verses a camera with 100mK sensitivity is 100% better and not as 0.05 C better. 4 2008 Electrophysics Corp. All rights reserved.

Electrophysics Resource Center: Understanding Camera REFERENCE PICTURE 160x120 100mK Sensitivity 100mK sensitivity is adequate for most applications where the image temperature span is >10 C, but the image degrades if you narrow the span more than 10 C. 320x240 70mK Sensitivity 70mK sensitivity lets you set a narrower span to 5 C while maintaining good image quality. 640x480 50mK Sensitivity 50mK sensitivity creates the most smooth noise free images. This level of sensitivity rivals the thermal sensitivity of some cooled (costly) cameras. An ISO 9001:2000 Certified Company UKAS #7096 - ANAB #A060693 5

Understanding Infared Camera Electrophysics Resource Center: Thermal Sensitivity Tests NETD Noise Equivalent Temperature Difference: Quantitative Measurement NETD is the scene temperature difference equal to either the internal noise of the detector (detector NETD) or the total electronic noise of a measurement system (system NETD). As a camera buyer you need to evaluate system NETD. The test setup (as shown in Illustration 1) consists of temperature control blackbody reference and some type of ambient (passive) object that creates a simple slit target for the camera to visualize. The temperature of the black body is adjusted until it nearly equals the ambient target temperature. An oscilloscope measures the analog video output of one horizontal line and at the point where the temperature delta between the reference and the ambient targets no longer creates a measureable signal the NETD is determine by the measured temperature difference between the reference and the ambient reference targets. (Illustration 1 NETD Test Setup) 30 C 30.05 30 C Illustration 1 NETD Test Setup Infrared Camera Video Output 6 2008 Electrophysics Corp. All rights reserved.

Electrophysics Resource Center: Understanding Camera MRTD Minimum Resolvable Temperature Difference: Qualitative Measurement This is a system test. An observer is asked to assess the minimum temperature difference at which a 4 bar target (see Illustration 2 MRTD Test Setup) can be resolved by watching the video output displayed as the temperature set points of the reference and the ambient targets are brought close together. This minimum difference will change with the spatial frequency of the bar target used. A curve of MRTD against spatial frequency is obtained which characterizes the performance of the imaging system. Modern infrared imaging systems can have low spatial frequency MRTDs of tens of milli-kelvins. The benefits of large format cameras is significant we you combine the need for high sensitivity while viewing high spatial frequencies. To simplify explaining the fundamentals of thermal sensitivity let s focus on a single pixel of the infrared sensor in an uncooled infrared camera. Each pixel in an uncooled focal plane array image sensor is essentially a resistor fabricated using MEMS (micro electro mechanical systems). Illustration 2 MRTD Test Setup Temperature Control As the temperature of the reference is brought closer to the ambient target, a point at which the operator can no longer see, a temperature delta will occur. The temperature difference just before the operator loses the image of the grid is the MRTD. 30 C 30 C 30 C 30.25 C 30.05 C 30 C.05.25 An ISO 9001:2000 Certified Company UKAS #7096 - ANAB #A060693 7

Understanding Infared Camera Electrophysics Resource Center: IR Radiation Silicon Nitride Leg Structure with electrical conductor 25µm Thin Film Resistor/Absorption Layer 0.5µm Y-metal 2.5µm B X-metal E Readout Circuit The basis structure of a thermal uncooled camera pixel (illustration shown above) is a microscopic bridge structure on which a thin resistor material and an absorbing layer have been deposited. Legs suspend the deck of bridge above an integrated circuit and provide electrical connection between the resistive bridge and the silicon readout circuit. The readout IC controls the voltage that biases the thin film resistor and multiplexes all the pixel signals out to the cameras imaging electronics. As infrared radiation is absorbed by each pixel its temperature changes as the photon energy (8-14 micron wavelength) is converted to heat which in turn changes the resistance of the pixel s thin film resistor. The readout IC sends a voltage across each micro bolometer element and a signal proportional to heat absorbed by each detector is the basis of a real time video image. The electrical circuit of an infrared sensor is very simple, a voltage is turned on to each pixel and a change in resistance of the thin film resistor based on the pixels temperature is sampled and converted into a digital value. All analog signal carry some level of noise along with the signal generated by the sensor. The ratio of signal to noise strongly impacts the image quality of a camera because the noise level is usually a fixed amount and as the detector gain is increased the system will begin to display the signal noise and you ll begin to see snow in the image. 8 2008 Electrophysics Corp. All rights reserved.

Electrophysics Resource Center: Understanding Camera The signal level of this noise is commonly specified as Noise Equivalent Temperature Difference. 2 Imaging Array (MEMS Resistors) A B C D E F G H I J Z Multiplexer ADC Video Processor Display 1 Battery Like any electrical circuit there are a lots of opportunities for electrical noise to get into systems, but the quality (signal to noise) of the signal coming directly off the infrared pixel has the most impact on thermal sensitivity, since nearly all camera developers have access to the same electronic components with which to create a camera. Therefore the thermal sensitivity in large part is based on the quality of the infrared imager array. Noise{ Clean Signal An ISO 9001:2000 Certified Company UKAS #7096 - ANAB #A060693 9

Understanding Infared Camera Electrophysics Resource Center: Other issues like the f number of the lens also impact thermal sensitivity. Your camera s lens is likely ƒ1.0 (the focal length is equal to the lens diameter) which is considered a fast lens. By comparison the f number in your digital camera is likely between ƒ3 and ƒ5 while the cameras used in cell phones and other low cost systems can be as high as ƒ20! As application demands lead to longer focal length lenses it is practical to go to slower optics in order to reduce the size, weight and cost of telephoto lenses and trade off some thermal sensitivity. For example, an F1.4 optic will result in 2X reduction in thermal sensitivity and an F2.0 optic a 4X reduction in thermal sensitivity. Therefore a system with 50mK sensitivity using a standard lens will still maintain good sensitivity (100mK) when a ƒ1.4 telephoto lens is attached to the camera verses another camera whose thermal sensitivity started at 100mK and becomes 200mK when viewing through a slower (ƒ number higher than 1). As you can see from the various issues raised within this paper the nature of thermal sensitivity is very complex but in the real world the human eye is extremely good at differentiating small differences in image quality that you ll know it (good sensitivity) when you see it. Non-Uniformity Correction As the number of pixels increases and their sensitivity improves the quality of image is increasingly dependent on a process called Non Uniformity Calibration or NUC. As we described earlier a microbolometer imaging array is essentially an array of tiny resistors and because of the micro scale of these devices there are variations in how each pixel responds to the infrared energy from an object. During manufacturing the infrared camera s sensor must be normalized, meaning that the differences in response and DC output for each detector must be zeroed out. Here are two images from a camera. The first is what a typical image looks like without any corrections and the other the result of the calibration correction. Thermal cameras typically feature an internal flag or iris that periodically is positioned in front of the detector as a constant temperature reference to zero out differences amongst the pixels. This is a fine tuning of the factory NUC process and is sometimes referred to as a touch up. 10 2008 Electrophysics Corp. All rights reserved.

Electrophysics Resource Center: Understanding Camera Image 1: Uncorrected Image Image 2: Corrected Image Image 1: Histogram of uncorrected image Image 2: Histogram after correction Because the touch up source is inside the lens, additional image quality improvements are possible when performing a touch up calibration through the lens either using a lens cap or exposing the camera to a large uniform surface. As camera performance improves the non uniformities created by the lens will begin to be seen and for the ultimate image quality a simple through the lens calibration step will ensure the highest image quality the camera is capable of generating. Benefits of high increased image quality: Much greater flexibility to inspect targets are varying distances Ability to visualize low thermal contrast targets More intuitive diagnosis of heat related problems Improved infrared visible fused image quality due to better matching of infrared and visible camera resolution.. Flexibility to incorporate lower cost and lighter weight optional lenses More intuitive diagnosis of temperature anomalies An ISO 9001:2000 Certified Company UKAS #7096 - ANAB #A060693 11

For more comprehensive White Papers visit our online Knowledge Center at www.electrophysics.com. 373E Route 46, Fairfield, NJ 07004 Phone: 973-882-0211 Fax: 973-882-0997 www.electrophysics.com 2008 Electrophysics Corp. All rights reserved.