1 DCIM SmartZone Monitoring and Management Solutions: Portfolio Overview [08-09-2014] Alistair Hunt 10/8/2014
2 SmartZone Value proposition REQUIREMENTS DELIVERABLE DRIVERS Risk Mitigation Resilience Sustainability Bench mark and regain Capacity Plan for the future Optimise, reduce OPEX Cost Management Legislation & CSR Granular Monitoring Link Power and Environmental monitoring relationships Physical Security and Access control Real time Out of Norm exception reporting Historical analysis reporting Centralised data collection Non-Invasive technology [Legacy Data Centres] Cross department stakeholder reporting Integration of IT and FM management architectures Asset Management Connectivity Management Professional Services Asset & Connectivity Management Gateways SmartZone Access control and Security Power Monitoring PDU s Inline & Clamp Meters Environmental Monitoring
3 Mapping to the 6 Zone Methodology 6 Zone is a logical, step-by-step methodology of assessing simplified, individual zones of the data center facility to holistically monitor, manage, and optimize each zone with greater control. 10/8/2014
4 6 Zone Methodology A Holistic Approach to Data Center Management Zone 1: Fiscal Utility Meters Zone 6: Device Level Monitoring 1 6 5 Zone 5: Rack & Cabinet Level Monitoring 2 Zone 2: Main Switchboard Distribution Circuits. 3 4 Zone 4: Branch Circuit PDU Zone 3: Plant Equipment 6 Zone Methodology addresses power, environmental, asset, and connectivity needs individually by zone or collectively across the entire infrastructure.
5 SmartZone Solutions Portfolio Services SmartZone Solutions Software Hardware
6 SmartZone Hardware Services SmartZone Solutions Software Hardware SmartZone Gateways Network-Enabled Hardware Network-Enabled Hardware Gateway-Enabled Hardware PViQ Intelligent Patch Panels (Connectivity SmartZone Network- Enabled Rack PDUs (and Sensors) SmartZone Gateway- Enabled Rack PDUs SmartZone Inline Meters SmartZone Environmental Sensors SmartZone Access and Control
7 SmartZone Hardware World-Class Breadth of Power Monitoring IP Network Applications: Typical power deployment, each PDU requires an IP address and direct connection to network Addresses standard requirements of power and environmental monitoring, up to 2 sensors per PDU Do not connect to gateway Applications: Advanced environmental monitoring up to 12+ sensors per cabinet Access control and beacons Switch port conservation via connection to gateway Applications: Non-invasive power monitoring for existing single phase in-cabinet power infrastructure Utilize gateway for network connection Applications: Power monitoring for existing incabinet power infrastructure Requires disconnection of existing power to install between feed to cabinet and existing PDU Utilize for 3rd party cabinets (eg EMC storage cabinet) Network- Enabled Rack PDU Gateway- Enabled Rack PDU Clamp Meter Inline Meters
8 SmartZone Hardware Gateway-Enabled Architecture Centralizes Device Management Consolidates multiple devices into a 1RU gateway through RJ45 ports to simplify connection and expansion of devices Primary/Secondary Network Interface Design Simplifies the network architectures and lowers overall power consumption by retaining all non-essential intelligence, electronics, and provides DC power monitoring supply within the gateway Utilizes a single IP Address Reduces number of physical IP ports required, reducing the allocation of capital IP costs and management overhead
9 SmartZone Hardware Environmental Sensors Examples of the types of sensors we carry include Temperature Sensors Detect the air or surface temperature of equipment in and around a rack, cabinet or room in a data center. Humidity Sensors Measure relative humidity of air and abnormal conditions to ensure the environment does not get too moist or dry, thus preventing damage to equipment. Airflow Sensors Measure air velocity in and around a rack, cabinet, ceiling or wall. PIR Sensors Passive infrared receivers, which constantly monitor the infrared energy levels around a room and recognize change caused by entry of an intruder. Smoke Sensors Enable immediate data capture and alerting of potentially fatal smoke or fire conditions at different IT and facility domain points, in either new or retrofit installations.
10 SmartZone Hardware Cabinet Access and Controls The SmartZone EPA064 and EPA126 Gateways are capable of supporting a physical access control solution for cabinets. There are two options: Keypad + Electronic Swing Handle Lock Gateway HID Card Reader + Electronic Swing Handle Lock
11 Third-Party Hardware Third-Party Power Meters Power Meters Northern Design MultiCube Socomec Diris A20 Socomec Diris A40/A41 Schneider PowerMeter PM710 Schneider PowerMeter PM810 Schneider PowerLogic ION6200 Schneider 7550 IME Nemo 72-L 10781401 Energy Meters EM21 Autometers IC-970 UPS with Modbus Cards or SNMP Socomec Green Power Delphys Socomec MX/MP Elite ZONE 2: Main Switchboard Distribution Circuits ZONE 3: Plant Equipment The listed third-party meters above can be read by SmartZone Software today to supplement customer solutions.
12 SmartZone Hardware PViQ Intelligent Patch Panels (Asset and Connectivity Monitoring) Industry-first connectivity management system that provides: PViQ Intelligence Modules Intelligent monitoring of patch field connectivity A zero RU intelligence module A removable interface unit Elimination of individual active equipment panels and controllers PViQ Patch Panels PViQ Fiber Trays
13 SmartZone Rack Energy Kits SmartZone Rack Energy Kits help small data centers realize the benefits of DCIM with specifically designed kits to provide costeffective power and environmental monitoring for small data center environments. A simple out of the box solution that includes power and environmental monitoring hardware and software, to optimize energy costs and maintain optimal uptime. Designed for small data centers and telecom closets with 30 or fewer cabinets or racks (Max of 60 power devices). INCLUDED IN THE BOX SmartZone Rack Monitoring Software SmartZone Gateway EP042 SmartZone Power Monitoring Device(s) Four different kit options Two Temperature Sensors One Set of Patch Cords
14 SmartZone Rack Energy Kits Multiple Monitoring Options SmartZone Rack Energy Kit with Clamp Meters An ideal solution for small data centers looking to quickly add power and environmental monitoring without the hassle or concern of powering down equipment. SmartZone Rack Energy Kit with Zero-RU Inline Meters An ideal solution for small data centers looking to quickly add power and environmental monitoring by cost-effectively upgrading or maximizing current data center resources. SmartZone Rack Energy Kit with 1RU Inline Meter An ideal solution for small data centers looking to quickly and cost-effectively add or build in power and environmental monitoring capabilities for cabinets that require one or more direct power feeds, (such as large servers, disk storage arrays, blade server enclosures, and network switches). SmartZone Rack Energy Kit with Rack PDUs An ideal solution for new (greenfield) builds looking to quickly and cost-effectively build in power and environmental monitoring capabilities.
How do SmartZone Rack Energy Kits Work?
16 SmartZone DCIM Software Rack Monitoring Software DCiQ PIM Services SmartZone Solutions Software Hardware
17 SmartZone DCIM Software SmartZone Rack Monitoring Software Included with SmartZone Rack Energy Kits, the SmartZone Rack Monitoring Software (formerly ENV-U3) provides live and historical views of current, temperature and humidity data readings, coupled with simple trending information of the parameters monitored. Simple desktop application Standard SNMP protocol Supports up to 60 power devices Polls devices and creates and logs SNMP traps as alerts Live and historical view of data Simple trending information and management reports SmartZone Rack Monitoring Software is a simple power and environmental software platform for small data centers or telecom closets with 30 or fewer cabinets
18 SmartZone DCIM Software DCIQ Software Platform As part of the SmartZone Software Suite, the DCIQ Software Platform is a power and environmental monitoring and management solution that provides centralized visibility of energy, cooling, and capacity via networked DCIM instrumentation. World-class scalable data collection engine Highly customizable dashboards and analytics Power and environmental real-time monitoring Event management and alarms Power control Cabinet access control DCIQ is a power and environmental software platform
Real time reporting and Alarming dashboard 19
Alarm Status report 20
Reporting Examples, Real time Alerting 21
Reporting Examples, Visual enhancement 22
Report Examples, Zone 6 Device Level 23
Tailored monthly summary report 24
2 Rack power capacity 25
26 SmartZone Software Panduit Physical Infrastructure Manager (PIM ) Software Platform As part of the SmartZone Software Suite, the PIM Software Platform is asset and connectivity monitoring and management solution that tracks the allocation and utilization of critical IT assets and networking resources, within your data center and remote sites, while providing strong visualization and analytics. Monitors IT asset information Automates connectivity documentation Integrates with asset management and network management platforms NEW PIM v5.1 Features include Best Fit Capacity and Stranded Capacity PIM is our available asset and connectivity software platform
27 SmartZone Solutions Portfolio Available Today Implementation Services that provide fullscale implementation, training, and support for software and hardware projects: Leverage Panduit s proven methodologies and industry best practices Provide dedicated training Augment your team so that they can focus on more critical data center operations. Single source of technical support Services SmartZone Solutions Hardware Software
28 Applying SmartZone Solutions Solution Use Cases and Applications SmartZone Solutions help data centers address challenges and opportunities across physical infrastructure capacity, efficiency (energy and operational) and uptime. Some examples of challenges that SmartZone helps to resolve include: Stranded Capacity in Data Centers o Power o Cooling o Space o Connectivity Thermal Performance Optimization Remote Management Power Distribution Choices and Intelligent Monitoring What Are Your Challenges?
Questions? 29
building a smarter, unified business foundation 30