DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

Similar documents
DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

DS10000ULFS-10V/10kA

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

High Performance Current Transducer ITL 900-T = A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Current Transducer CTSR 1-P = 1A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

ULTRASTAB IHF Precision Current Transducer

ULTRASTAB I U Precision

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

DSSIU-6-1U-V. Features VOM:

Voltage transducer DVL 50

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

= 600 V. Voltage transducer DVM 600 V PN

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Sensors & Accessories

World-Class Accuracy & Measurement Range (40 Conventional Models)

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Current transducer FHS 40-P/SP600

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

V P N. Voltage transducer DVM 4200 = 4200 V

AUTOMOTIVE CURRENT SENSOR HC6H300-S

Current transducer FHS 40-P/SP600

SPECIFICATION Item No.: T60404-P4640-X100

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

SPECIFICATION Item no.: T60404-N4646-X764

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

V P N. Voltage transducer DVL 1000 = 1000 V

Technical catalog. Current sensors Voltage sensors. Contact John G Peck Ltd - jgpl.com

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Residual Current Monitoring Unit RCMU101SN-4P16

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

= 1000 V. Voltage transducer DVC 1000-P V P N

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Residual Current Monitoring Unit RCMU101SN-4P16C

AUTOMOTIVE CURRENT TRANSDUCER DHAB S/15

Technical catalogue. Current sensors Voltage sensors

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Current Sensor : F02P***S05L

Fluxgate system / Voltage-output type F03P***S05 SERIES

SPECIFICATION Item No.: T60404-P4640-X102

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

Transcription:

DL000ID Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 6 ppm offset Current output Fluxgate, closed loop compensated technology with fixed excitation frequency and second harmonic zero flux detection for best in class accuracy and stability Industry standard DSUB 9 pin connection Green diode for normal operation indication Full aluminum body for superior EMI shielding and extended operating temperature range Applications: MPS for particles accelerators Gradient amplifiers for MRI devices Stable power supplies Precision drives Batteries testing and evaluation systems Power measurement and power analysis Current calibration purposes Large aperture 68mm for cables and bus bars Specification highlights Symbol Unit Min Typ Max Nominal primary AC current IPN AC Arms 000 Nominal primary DC current IPN DC A -3000 3000 Measuring range ÎPM A -3000 3000 Primary / secondary ratio n : n :500 :500 Linearity error ƐL ppm - Offset current (including earth field) IOE ppm -6 6 DC-0Hz Overall accuracy @5 C (= Ɛ L + I OE ) accɛ ppm -7 7 AC Maximum gain error 0Hz to khz ƐG % ±0.0 Operating temperature range Ta C -40 65 Power supply voltages Uc V ±4.5 ±5.75 All ppm (or %) values refer to nominal current page - 07--9

DL000ID Electrical specifications at Ta=3 C, supply voltage = ± 5V unless otherwise stated Parameter Symbol Unit Min Typ. Max Comment Nominal primary AC current Nominal primary DC current I PN AC Arms 000 Refer to fig. & for derating I PN DC A -3000 3000 Refer to fig. for derating Measuring range I PM A -3000 3000 Refer to fig. & for derating Overload capacity Î OL ka 0 Non-measured, 00ms Nominal secondary current Primary / secondary ratio Measuring resistance Linearity error Offset current DC-0Hz Overall accuracy @5 C (= ƐL + IOE ) Offset temperature coefficient I SN ma -000 000 At nominal primary DC current :500 :500 R M Ω 0 3 Refer to fig. for details ppm - ppm refers to nominal current µa - µa refers to secondary current ppm -6 6 ppm refers to nominal current µa - µa refers to secondary current accɛ ppm -7 7 ppm refers to nominal DC current ppm/k -0. 0. ppm refers to nominal current µa/k -0. 0. µa refers to secondary current Bandwidth f(-3db) khz 300 Small signal, graphs figure 3 Amplitude error 0Hz khz 0.0% khz -0kHz ƐG %.50% % refers to nominal current 0kHz - 00kHz 3.00% Phase shift 0Hz khz 0.04º khz -0kHz q º 0.5º 0kHz - 00kHz 3º Response time to a step current IPN tr @ 90% µs di/dt = 00A/µs Noise 0-00Hz 0.0 0 - khz 0.0 noise ppm rms 0-0kHz.0 0-00kHz 3.50 Fluxgate excitation frequency Induced rms voltage on primary conductor Power supply voltages Positive current consumption Negative current consumption Operating temperature range Stability Offset stability over time Offset change with vertical external magnetic field Offset change with horizontal external magnetic field Offset change with power supply voltage changes Offset change with absolute power supply voltages tracking Ɛ L I OE TC IOE fe xc khz 5.6 µv rms 5 Uc V ±4.5 ±5.75 Ips ma 60 70 85 Add Is (if Is is positive) Ins ma 50 60 70 Add Is (if Is is negative) Ta C -40 65 ppm/mon th µa/mont Measured on secondary current -0. 0. ppm refers to nominal current -0. 0. µa refers to secondary current µa /mt µa /mt 0. 0.8 0.8 (perpendicular to bus bar) µa refers to secondary current (parallel to bus bar) µa refers to secondary current µa /V 0 0.04 µa refers to secondary current µa /V 0.0 0.04 µa refers to secondary current page - 07--9

Primary Current (A) Maximum measurement resistor Value (Ohm) DL000ID 5 Maximum measurement resistor vs. ambient temperatures 4 3 0 000 00 400 600 800 3000 300 3400 Primary Current, DC or peak (A) R_max_5 R_max_45 R_max_65 Frequency and ambient temperature derating (Fig. ) 0000 Maximum primary current A rms 000 00 0 0Hz 00Hz,000Hz 0,000Hz 00,000Hz,000,000Hz Primary Current (Hz) Max current (Arms) 65 deg Max current (Arms) 45 deg Max current (Arms) 5 deg Frequency characteristics (Fig. 3) 0.00 Amplitude / Phase 5.00 0.00 5.00 0.00-5.00-0.00 0Hz 00Hz,000Hz 0,000Hz 00,000Hz Amplitude (%) Phase Error (deg) page 3-07--9

DL000ID Isolation specifications Parameter Unit Value Clearance mm Creepage distance mm Comparative tracking index (CTI) V > 600 Rms voltage for AC isolation test, 50/60 Hz, min - Between primary and (secondary and shield) - Between secondary and shield kv 4.4 0. Impulse withstand voltage (./50µs) kv 6.3 Rated rms isolation voltage reinforced isolation, overvoltage category III, Pollution degree according to - IEC 600- - EN50780 V 500 500 Absolute maximum ratings Parameter Unit Max Comment Primary ka 0 Maximum 00ms Power supply V ±6.5 Environmental and mechanical characteristics Parameter Unit Min Typ Max Comment Ambient operating temperature range C -40 65 Storage temperature range C -40 65 Relative humidity % 0 80 Non-condensing Mass kg 6.5 Connections Standards Power supplies: D-SUB 9 pins male EN 636- EMC EN 600-:00 Safety page 4-07--9

DL000ID Advanced Sensor Protection Circuits ASPC Developed to protect the current transducer from typical fault conditions: Unit is un-powered and secondary circuit is open or closed Unit is powered and secondary circuit is open or interrupted Both DC and AC primary current up to 00% of nominal value can be applied to the current transducers in the above situations without damage to the electronics. Please notice that the sensor core can be magnetized in all above cases, leading to a small change in output offset current (less than 0ppm) Status pins When transducer is operating in normal condition, the status pins (3 and 8) are shorted. Status pins properties: - forward direction pin 8 to pin 3, maximum forward current 0mA - maximum forward voltage 60V, maximum reverse voltage 5V Accessories 4-channel power supplies unit for connection up to 4xDL000 : DSSIU-4 6-channel power supplies unit for connection up to 6xDL000 : DSSIU-6 Transducer cables in 5 lengths (m - 5m - 0m - 5m - 0m): DSUB - DSUB5 - DSUB0 - DSUB5 - DSUB0 Transducer cable 3m for connection to end-user s power supply: Transducer cable for lab PS (with access to current output via 4 banana jacks) Please visit Danisense homepage for relevant datasheets page 5-07--9

DL000ID Standard DSUB-9 current output 5 4 3 9 5 9 4 8 3 7 6 When sensor is operating in normal condition the status pins are shorted. 8 7 6 Status pin properties. - Forward direction pin 8 to pin 3 - Maximum forward current 0mA - Maximum forward voltage 60V - Maximum reverse voltage 5V -Vc +Vc 0V Status Status NC NC Out+ Out- External R Measurement Resistor Mounting instructions Positive current direction Base plate mounting 4 holes 5.5 x 4 x M5 steel screws / 6N.m Bottom direct mounting (after unscrewing the base plate) 6 holes 4. x 7 6 x M4 steel screw / 4N.m Is identified by an arrow on the transducer body page 6-07--9