Brunata Optuna H. Properties. Counter

Similar documents
SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SONOMETER TM 1100 Ultrasonic compact energy meter

RAY COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL

SONOMETER TM 1100 Ultrasonic compact energy meter

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

INFOCAL 8 Energy calculator

RAY MC COMPACT ENERGY METER MECHANICAL

SonoMeter 31 Energy Meters

Infocal 9 Energy calculator

WESAN WP E ELECTRONIC METER WOLTMAN

SONOMETER TM 1000 Ultrasonic compact heat meter

ULTRASONIC D. Compact ultrasonic heat meter

SonoSelect 10 and SonoSafe 10 Energy Meters

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

SONO 1500 CT Ultrasonic flow sensor

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

MULTICAL 302 DATA SHEET

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Supercal 531 Multi function Integrator that lives up to Your highest expectations

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

HDU-SF (Horizontal Distribution Units - Single Flat)

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

SONOMETER 2000 Ultrasonic heat meter

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

MULTICAL 403. Data sheet

MULTICAL Energy meter TS PTB. Application

MULTICAL 601 DATA SHEET

Heat meter Q heat 5 US

SVM F22. Calculator for heating or cooling applications. Data sheet

User s Manual. F2 Calculator. A metering component for thermal energy applications

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

MULTICAL 403. Data sheet

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

Brunata. Technical Manual for HGP-series. Volume and Energy Meters, 15 to 600 m3/h

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat)

US-W/V US-S/FFL. Certificate No.: DE-09-MI004-PTB018 (MID heat) / 22.72/09.01 (National German cooling)

Annex to application for conformity assessment of Heat meters in accordance with MID

Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron

MULTICAL 602 DATA SHEET

FLOMID FX Electromagnetic Flowmeter

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Electronic Heating Energy Meters

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

MULTICAL 602. Data sheet. Heat and cooling meters with unlimited communication

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ultego III smart plus

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

SN+ MID MASTER + APPLICATION WATER METERS

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

SVM F27 Compact. Compact heat meter. Users manual

Installation & User Guide. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

PEM353. Universal measuring device

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Digital flow transmitter for continuous flow measurement

flowiq 3100 Data sheet

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters

Release A Member of the

ICARUS ELECTRONIC GAS VOLUME CONVERTER

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

E l e c t r o m a g n e t i c f l o w m e t e r s

Price list 2018 Devices

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

Current Clamp. 210

mass flowmeter for compressed air

Technical Description MULTICAL 302. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

The innovative way forward symphonic sensor net radio system

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

MID MP-01, MP WATER MEASUREMENT

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

EverBlu. Wireless fixed data collection system

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

INLINE flowmeter for continuous flow measurement

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

ULTRAFLOW TS Application OIML R75 DS/EN 1434

INLINE flowmeter for continuous flow measurement

WATERFLUX 3070 Technical Datasheet

4-20mA, 0-10V and general process measuring bargraph displays

sustainable savings that can be viewed directly on the internet

flowiq 3100 Data sheet

ULTRAHEAT T230 ULTRACOLD T230

Fluxi 2000/TZ. Turbine Gas Meter

INLINE flowmeter for continuous flow measurement

TYPE APPROVAL CERTIFICATE

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

HMM/LPHW LPHW Heat Meters

Transcription:

Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first generation of meters designed directly for remote reading. It records a large number of data, which allows a complete overview of the consumption as well as the operational load imposed by an installation. Together with its uniquely long life of 16 years, this makes Optuna H the most resource-optimising meter on the market, in financial, operational and environmental terms. Properties Temperature range 5-130/150 C No sensitivity to soiling Turbulence-free flow around the reflectors 16 year battery life with radio Extensive data saving of monthly values for two years, read via optical interface Much improved radio function for remote data reading Built-in radio module meeting Real Data and Open Metering Standard (868 MHz) Individual remote reading (AMR) via optional plug and play modules Two communication ports (e.g. M-Bus and pulse) and integral radio reading Several power supply options Great long-term stability Optional leak monitoring Further information The Optuna H heating energy meter consists of an ultrasound flow sensor, a counter with battery or power supply, which can be replaced without breaking any verification seal, two temperature sensors which can also be replaced and a wall bracket for mounting the integrator unit separately from the flow sensor, if desired. The meter is designed accor- ding to the ultrasound principle, without movable parts. This ensures great measuring accuracy and long life as well as great stability even at varying water quality. Counter The counter casing can be installed either as a compact unit directly on the flow sensor unit and turned in steps of 90 or externally on a wall using the accompanying bracket. The Optuna H meter s display is designed with strong, easy-to-read figures and symbols which are clearly visible from all sides. The meter can therefore be read without problems even in difficult conditions. A clear and user-friendly operating button to the right of the display makes it easy to switch between the different views. Any errors are automatically saved and shown in the display. Readings and other relevant values, are stored sagely in an EEPROM type memory. This memory regularly saves all measured values, the meter s parameter settings and any error reports. Brunata makes reservations against any errors and omissions in above UK-QB 101175/02.06.2015

General Use Heating cooling heating and cooling Approvals MID (DE-10-MI004-PTB013) Installation of flow sensor Optional Power supply with battery 3.6 VDC - A-type (max. life 11 years) - 3.6 VDC - D-type (max. life 16 years) Power supply from mains 24 VAC - 230 VAC Temperature sensor types Pt 100 or Pt 500, two-wire - Ø 52./2mm or direct sensor Cable length for sensors Pt 100 : 2M - Pt 500 : 2/3 1 /5m Measuring cycle for volume Mains powered: 1/8 s - A-type battery: 1/2 s - D-type battery : 1/1 s Integrator basic properties and functions Environment class Ambient class Ambient temperature Storage temperature Class C Protection Class IP 54 Class E2 + M2 5 55 C (>35 C have a positive lifetime effect) -25 +60 C (>35 C max. 4 weeks) Communication 3 communication ports (e. g. M-Bus + M-Bus + Int. Radio; 2 primary addresses, 1 secondary address) Integral radio Interface standard Interface, options Optional Optical ZVEI interface Temperature range, heating 5 130 / 150 C 2 outlets for modules with M-Bus, L-Bus, RS 232, RS 485, pulse output, pulse input or analogue output. Temperature range, cooling and heating/cooling Extensive saved data 5 50 / 5 105 C Saved monthly 1) ; saved history log; saved status codes 1) Programmable saving interval (daily, weekly, monthly...) Integrator integral radio Frequency wavelength Radio telegram type Updating, transmitted data Data transfer Transmission interval 868 or 434 MHz Real Data or Open Metering Standard (OMS) Online no time delay between meter registration and data transfer One way 12 20 s depending on telegram length (duty cycle) Display Display LCD, 8 digits Units MWh kwh GJ Gcal Mbtu gal GPM - C - F m3 - m3/h Mximum display values 99,999,999 9,999,999.9 999,999.99 99,999,999 Values displayed Energy - output - volume - flow - temperature - other

Interfaces Optical ZVEI interface, for communication of test, M-Bus protocol M-Bus Configurable telegram, meets EN 1434-3, data reading and parameter setting via polarity-secured two-wire cable, automatic recognition of Baud speed (300 and 2400 Baud), 2 M-Bus with 2 primary addresses L-Bus Adapter for extreme radio module, configurable telegram, meets EN 1434-3, data reading and parameter setting via polarity-secured two-wire cable RS232 Serial interface for communication with external devices, special data cable required, M-Bus protocol, 300 and 2400 Baud RS484 Serial interface for communication with external devices, power supply 12V + 5V, M-Bus protocol, 2400 Baud Pulse output Module with 2 pulse outputs (Open Collector, potential-free) 4 Hz (pulse width 125 ms), 100 Hz (pulse width 5 ms, relationship pulse duration/pulse pause 1:1, configurable with IZAR@SET software Pulse input Module with 2 pulse inputs, max. 20 Hz, configurable with IZAR@SET software, remote data transfer also possible Combined pulse input and output Module with 2 pulse inputs and 1 pulse output, configurable with IZAR@SET software, required for leak alarm Analogue output Module for 4 20 ma with 2 programmable passive outputs, programmable values at error states Temperature input Power in sensors, ma Pt 100 max. power < 8 (rms < 0,015), Pt 500 max. power < 2 (rms < 0,012) Measuring cycle with grid operation T With netdrift: 2 s; with A-type-batteri: 16 s; with D-type-batteri: 4 s Start temperature difference ΔΘ 0,125 K Minimum temperature difference ΔΘ min 3 K Maximum temperature difference ΔΘ max 177 K Absolute measuring range Θ 1 180 C

Technical data for flow sensor Nominal, continuous flow, q p : m 3 /h 0,6 0,6 0,6 1,5 1,5 1,5 Nominal diameter, DN: mm 15 20 20 15 20 20 Construction length, L: mm 110 130 190 110 130 190 Start value: l/h 1 1 1 2,5 2,5 2,5 Minimum flow rate, q i : l/h - - - 6 6 6 Maximum flow rate, q s : m 3 /h 1,2 1,2 1,2 3 3 3 Overload at: m 3 /h 2,5 2,5 2,5 4,6 4,6 4,6 Operating pressure, PN: bar 16 1 16 1 16 1 16 1 16 1 16 1 Head0 loss at q p p: mbar 85 85 85 75 75 75 Temperature range, heating: C 5... 130 5... 130 5... 130 5... 130 5... 130 5... 130 Temperature range, cooling: C 5... 50 5... 50 5... 50 5... 50 5... 50 5... 50 Temperature range, heating and cooling: C 5... 105 5... 105 5... 105 5... 105 5... 105 5... 105 Zeta resistance value: 21,3 67,5 67,5 4,3 13,6 13,6 Technical data for flow sensor Nominal, continuous flow, q p : m 3 /h 2,5 2,5 3,5 3,5 6 6 Nominal diameter, DN: mm 20 20 25 32 25 32 Construction length, L: mm 130 190 260 260 260 260 Start value: l/h 4 4 7 7 7 7 Minimum flow rate, q i : l/h 10 10 35 35 24 24 Maximum flow rate, q s : m 3 /h 5 5 7 7 12 12 Overload at: m 3 /h 6.7 6.7 18.4 18.4 18.4 18.4 Operationg pressure, PN: bar 16 1 16 1 16 1 16 1 16 1 16 1 Head loss at q p p: mbar 100 100 44 44 128 128 Temperature range, heating: C 5... 130 5... 130 5... 130 5... 130 5... 130 5... 130 Temperature range, cooling: C 5... 50 5... 50 5... 50 5... 50 5... 50 5... 50 Temperature range, heating and cooling: C 5...105 5... 105 5... 105 5... 105 5... 105 5... 105 Zeta resistance value: 4 4 2.8 7.4 2.8 7.4 Nominal, continuous flow, q p : m 3 /h 10 10 15 25 40 60 Nominal diameter, DN: mm 40 40 50 65 80 100 Construction length, L: mm 200 300 270 300 300 360 Start value: l/h 20 20 40 50 80 120 Minimum flow rate, q i : l/h 40 3 /100 40 3 /100 60 3 /150 100 3 /250 160 240 3 /600 4 1200 5 Maximum flow rate, q s : m 3 /h 20 20 30 50 80 120 Overload at: m 3 /h 24 24 36 60 90 132 Operation pressure, PN: bar 16 1 16 1 25 2 25 2 25 2 16/25 2 Head loss at q p p: mbar 95 95 80 75 80 75 Temperature range, heating: C 5... 150 5... 150 5... 150 5... 150 5... 150 5... 150 Temperature range, cooling: C 5... 50 5... 50 5... 50 5... 50 5... 50 5... 50 Temperature range, heating and cooling : C 5... 105 5... 105 5... 105 5... 105 5... 105 5... 105 Zeta resistance meter: 3,8 3,8 3,56 3,4 3,4 3,8 1): Also available with PN 25 bar 2): Also available with PN 40 bar 3): Only with horizontal installation 4): Only with vertical (up and down) or oblique installation 5): Only with installation upside down Head loss curve and accuracy curve Head loss (mbar) -------- Class 2 Optuna H Flow (l/h) Head loss curve Accuracy curve

Dimensions for threaded connection H2 B H1 H L L2 Nominal, continuous flow, q p : m 3 /h 0,6 0,6 0,6 1,5 1,5 1,5 Nominal diameter, DN: mm 15 20 20 15 20 20 Construction length, L: mm 110 130 190 110 130 190 Construction length with fittings, L2: mm 190 230 290 190 230 290 Length, counter, L1: mm 150 150 150 150 150 150 Height, H: mm 14,5 18 18 14,5 18 18 Height, H1: mm 82 84 84 82 84 84 Height, counter, H2: mm 54 54 54 54 54 54 Width, counter, B: mm 100 100 100 100 100 100 Connection threading, meter: G 3 /4 G1B G1B G 3 /4 G1B G1B Connection threading, fitting: R 1 /2 R 3 /4 R 3 /4 R 1 /2 R 3 /4 R 3 /4 Weight: kg 0,76 0,85 0,96 0,76 0,85 0,96 Nominal, continuous flow, q p : m 3 /h 2,5 2,5 3,5 3,5 6 6 Nominal diameter, DN: mm 20 20 25 32 25 32 Construction length, L: mm 130 190 260 260 260 260 Construction length with fittings, L2: mm 230 290 380-380 - Length, counter, L1: mm 150 150 150-150 - Height, H: mm 18 18 23-23 - Height, H1: mm 84 84 88,5-88,5 - Height, counter, H2: mm 54 54 54-54 - Width, counter, B: mm 100 100 100-100 - Connection threading, meter: G1B G1B G1 1 /4B - G1 1 /4B - Connection threading, fitting: R 3 /4 R 3 /4 R1 - R1 - Weight: kg 0,85 0,96 1,5-1,5 - Nominal, continuous flow, q p : m 3 /h 10 10 15 25 40 40 Nominal diameter, DN: mm 40 40 50 65 80 100 Construction length, L: mm 200 300 270 300 300 360 Construction length with fittings, L2: mm 340 440 - - - - Lenght, counter, L1: mm 150 150 - - - - Height, H: mm 33 33 - - - - Height, H1: mm 94 94 - - - - Height, counter, H2: mm 54 54 - - - - Width, counter, B: mm 100 100 - - - - Connection threading, meter: G2B G2B - - - - Connection threading, fitting: R1 1 /2 R1 1 /2 - - - - Weight: kg 2,9 3 - - - -

DN K Dimensions for flange connection L1 H H1 D D1 L F Nominal, continuous flow, q p : m 3 /h 0,6 0,6 0,6 1,5 1,5 1,5 Nominal diameter, DN: mm 15 20 20 15 20 20 Construction length, L: mm 110 130 190 110 130 190 Length, counter, L1: mm - - 150 - - 150 Height, H: mm - - 47,5 - - 47,5 Height, H1: mm - - 84 - - 84 Height, counter, H2: mm - - 54 - - 54 Width, counter, B: mm - - 100 - - 100 Flange dimensions, F: mm - - 95 - - 95 Flange diameter, D: mm - - 105 - - 105 Internal pipe diameter, K: mm - - 75 - - 75 Diameter, flange bore, D1: mm - - 14 - - 14 Number of flange bores: pce. - - 4 - - 4 Weight: kg - - 2,75 - - 2,75 Nominal, continuous flow, q p : m 3 /h 2,5 2,5 3,5 3,5 6 6 Nominal diameter, DN: mm 20 20 25 32 25 32 Construction length, L: mm 130 190 260 260 260 260 Lenght, counter, L1: mm - 150 150 150 150 150 Height, H: mm - 47,5 50 62,50 50 62,5 Height, H1: mm - 84 88,5 88,5 88,5 88,5 Height, counter, H2: mm - 54 54 54 54 54 Width, counter, B: mm - 100 100 100 100 100 Flange dimensions, F: mm - 95 100 125 100 125 Flange diameter, D: mm - 105 114 139 114 139 Internal pipe diameter, K: mm - 75 85 100 85 100 Diameter, flange bore, D1: mm - 14 14 18 14 18 Number of flange bores: pce. - 4 4 4 4 4 Weight: kg - 2,75 3,5 4,8 3,5 4,8 Nominal, continuous flow, q p : m 3 /h 10 10 15 25 40 60 Nominal diameter, DN: mm 40 40 50 65 80 100 Construction length, L: mm 200 300 270 300 300 360 Lenght, counter, L1: mm - 150 150 150 150 150 Height, H: mm - 69 73,5 85 92,5 108 Height, H1: mm - 94 99 106,5 114 119 Height, counter H2: mm - 54 54 54 54 54 Width, counter, B: mm - 100 100 100 100 100 Flange dimensions, F: mm - 138 147 170 185 216 Flange diameter, D: mm - 148 163 184 200 235 Internal pipe diameter, K: mm - 110 125 145 160 180 1 /22 Diameter, flange bore, D1: mm - 18 18 18 19 19 1 /22 Number of flange bores: pce. - 4 4 8 8 8 Weight: kg - 6,4 7,0 8,9 10,9 16,4 1): Values for PN 16 casing