Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T

Similar documents
SGMW-xxx Millimetre Wave Oscillator

PI-150 Broadband Power Indicator

PI-10 Broadband Power Indicator

BPM214: Bidirectional Power Meter for WR-975 Waveguide

Millimetre Wave Generator G4-143g

and GHz. ECE Radiometer. Technical Description and User Manual

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

PXA Configuration. Frequency range

2100L Broadband Power Amplifier

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

A 500 Broadband Power Amplifier

3100LA Broadband Power Amplifier

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

1140LA Broadband Power Amplifier

OPERATION & MAINTENANCE MANUAL FOR U-9353 UPCONVERTER JANUARY 2001 CUSTOMER

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.

EO Modulator Driver and Source Models 3363-A, 3363-B, and 3363-C

Full protection IN - OUT

LBI Installation & Operation

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

PowerMonitor III. Digital Power and SWR meter for HF bands

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

Ocean Controls KT-5221 Modbus IO Module

MADEinUSA OPERATOR S MANUAL. RS232 Interface Rev. A

Agilent E8267C/E8257C/E8247C PSG

3 AXIS RF ELECTROMAGNETIC FIELD METER

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Ultrasonic Multiplexer OPMUX v12.0

SV613 USB Interface Wireless Module SV613

Stensat Transmitter Module

SERIES 8000 LAN FOUR 1X6 TWO 1X2 Product Part Number:

Stensat Radio Beacon

IVCAD VNA Base Load Pull with Active/Hybrid Tuning. Getting Started v3.5

User Manual CXE Rev.002 Broadband Cable Networks March 3, (10) CXX Series. User Manual. Teleste Corporation CXE880.

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

High-speed programmable attenuator MAT800

GM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

Small RF Budget SRB MX145

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

COM-POWER OPERATION MANUAL ACS W

Q-SERIES. Amplifiers. QPAIR Redundancy Switch Amplifier System. Installation & Operation Manual

Microprocessor Control Board Set Up Procedures (OR PLC)

External Source Control

Artifex LIV 110. Laser Diode Characterization System. Engineering

TXS. KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel D Otterfing Fax

OHIO SEMITRONICS, INC. DIGITAL AC POWER MONITOR OSI SPECIFICATIONS

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

GPS Time and Frequency Reference Receiver

GHz UPCONVERTER TESTING TABLE. 2.3GHz Out-Band ( GHz) Spurious. Level (dbc) min

DEC-001 Installation Instructions

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

13. OP-03 RS-232C SERIAL INTERFACE

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Multi-Function Assemblies

MDS SD4 Software-Controlled Digital Communications Firmware Release 1.x.x

SMARTALPHA RF TRANSCEIVER

TELEDYNE MICROWAVE SOLUTIONS. Summary. NF v1. the carrier (10MHz

Endurance R/C Wi-Fi Servo Controller 2 Instructions

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Setup of Gain Control System (MGC/AGC)

Blue Bamboo P25 Device Manager Guide

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

Using the Integrating Sphere in the Multiple Application Platform (MAP)

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

ROTRONIC HygroClip Digital Input / Output

AVL-10000T AUDIO VIDEO LINK TRANSMITTER TECHNICAL MANUAL

DRF7020D20 20dBm ISM RF Transceiver Module V1.31

Blue Point Engineering

Agilent EPM Series Power Meters

15 Summary. Electrical Specifications. RF output Frequency. Out-Band Spurious. Mechanical and Environmental Specifications. Mechanical shock MTBF

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater

INCLINOMETER RS232 SWITCH

medlab Two Channel Invasive Blood Pressure OEM board EG 02000

InfraStruXure Manager v4.x Addendum: Building Management System Integration

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

SMR5000F. User Manual. Smart Radio Data Repeater. Web Site: P.N.: Book 092

Catalog

DRF7020D13 13dBm ISM RF Transceiver Module

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node

200 us/2 ms/20 ms/200 ms, TDS ( PPM ) Real time data logger, Data logger no., RS232 CONDUCTIVITY METER Model : YK-2005CD

User manual. Inclinometer with Analog-RS232-Interface IK360

(Translated with Google Translate. Sorry, probably not the best English )

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

RF EMF Strength Meter

Catalog

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

CW Transmitter. User s Manual

2.9GHz SPECTRUM ANALYZER

CXE880 FIBRE OPTIC NODE

Reference Standard Models RS 2120 RS 2320

Ku-Band VSAT Block Up Converters

Multi-Channel RS-232 Serial RF Transceiver

MD-5060 DIGITAL MEGOHMMETER

Thruline RF Directional Wattmeters

Quick Start Guide for the PULSE PROFILING APPLICATION

SDI SPECTRADYNAMICS, INC GHZ RUBIDIUM FREQUENCY SYNTHESIZER OPERATING MANUAL

PA FAN PLATE ASSEMBLY 188D6127G1 SYMBOL PART NO. DESCRIPTION. 4 SBS /10 Spring nut. 5 19A702339P510 Screw, thread forming, flat head.

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

Transcription:

ELVA-1 Microwave Ltd. S.A. Mm-wave Division e-mail: sales@elva-1.com Internet: http://www.elva-1.com/ Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T 1

Specifications Operating Frequency Range: 60-90GHz Max measured power level: 20 mw (+13dBm) Dynamic range (typ) 50 db Frequency set step: 1GHz, 0.5GHz, 0.25GHz, 0.2GHz, 0.1GHz, 0.05GHz, 0.02GHz, 0.01GHz Measurement time (max): 0.5 sec Input VSWR: 1.4:1 (max) Interface port: RS-232 (DB-9), GPIB Power sensor port: WR-12/UG-387/U Power supply: 110 VAC Software version 2620-110707 PC protocol ELVA and SCPI Ambient air temperature: +5 to +40 deg. C conditions: air humidity: Up to 95 % 2

General Description The power meter with E-band power sensors (further DPM) was designed for measurement of CW mm-wave power level within 60GHz - 90GHz frequency range. The following possibilities of operating are provided in DPM: - measurement of CW power level in Watt or in dbm - setting of frequency step, control mode - operating with PC using RS-232 port or GPIB ports - setting of frequency step, indication of measured CW power level in Watt or in dbm, control mode, squeak ON/ OFF mode through RS-232 or GPIB interface. Note: To avoid sensor damage do not measure mm wave power more than the MAX level indicated on power sensor: 20 mw (+13 dbm). One can measure mm-wave power until sign OVERLAOD appears on the top line of LCD. Alarm buzzer sounds at the same time. Measured power level is at the bottom line of LCD. If sign OVERLOAD appears one must decrease input mm-wave power until OVERLOAD disappears. The sensitivity of the sensor is frequency depended and the max measured power can exceed the MAX level at some frequencies. It does not result in damage of power sensor. 3

Block-scheme of the Power Meter is shown in fig. 1. 110 VAC Power supply Liquid Crystal Display Power sensor with EEPROM and pre-amplifier Video amplifier AD Converter Controller Interface board RS-232 or GPIB Control and Display Unit. Fig. 1. Block-scheme of the Power Meter. To get right absolute value of measured power it is necessary to set frequency of measured signal. Value of measured frequency is set manually using 12-buttons keyboard or automatically through interface port. Frequency format is XXX.XX. The frequency can be set manually in the format or insert through RS-232 or GPIB interface. It is possible to shift the set frequency manually using * and # buttons. One press on the buttons shifts the frequency correspondingly down and up on one step. Step of frequency has a few fixed values within 0.01GHz 1GHz range. Two line LCD displays set signal frequency in GHz and absolute power value in microwatts (uw), milliwatts (mw) or dbm. 4

Power Sensor The power sensor is based on Zero-Biased Detector (ZBD) with Low Barrier Schottky Diode of ELVA-1 Ltd. manufacture. The power sensor provides high sensitivity, fast measurement speed, and quick response to changes of input power. The sensitivity of the detector is frequency depended. To get right absolute value of measured power it is necessary to set frequency of measured signal using 12-bottons keyboard on front panel. The amplitude and frequency dependences of the power sensor are stored in EEPROM installed inside. There is an isolator at the input of the power sensor. Isolator provides good matching of the power sensor with output of mm-wave power source. To improve sensitivity and decrease noise level a pre-amplifier is built in the power sensor. That is very important when small (< 10 microwatt) power is being measured. Block-scheme of E-band power sensor is shown in fig 2. Outward appearance of the sensor is presented in fig.3. 60-90GHz Input Waveguide Attenuator Zero Biased Detector Pre-amplifier & EEPROM +5 VDC Signal Ground 1 Fig. 2. Block-scheme of E-band Power Sensor 2 Fig 3. Power Sensor 1- Case with Zero-Biased Detector and Pre-amplifier with EEPROM inside, 2 Mm-wave input 5

Control and Display Unit. Control and Display Unit has 12 keys keyboard, 2-lines LCD on upper panel and power switch, fuse and connectors on the rear panel. The top line of the display shows the set frequency of mm-wave signal entered by keyboard or through RS-232 or GPIB interface; the bottom line indicates measured power. Refresh rate of measured power is about 2 times per second. Ten digital keys ( 0 9 ) are to be used for manual input of the frequency, key * to decrease frequency, key # to increase it. One pressure on the key shifts frequency at set step value. Possible frequency values are within 60-90 GHz for E-band sensor. Input frequency format is XXX.XX GHz. All 5 figures must be entered. E.g. to set frequency 90.00GHz one enters symbols: 0-9-0-0-0.Wrong values will be rounded to one of boundary values. Note. In case of not valid actual signal frequency setting there is an error of displayed mm-wave power because of non-flatness of calibration frequency curve. Outward appearance of the power meter is shown in fig 4 and 5. 1 2 Fig.4 Upper Panel of the DPM-12 Power Meter 1 Decreasing frequency key, 2 Increasing frequency key 6

4 5 6 1 2 3 Fig.5 Rear Panel of the DPM-12 Power Meter 1- GPIB port, 2 RS-232 port, 3 AC power socket, 4 - Power sensor connector, 5 Fuse, 6 Power On/Off switch. Frequency setting and receiving of measured power value can be realized using interface ports. Interface dialog consists of request (PC DPM) and answer (DPM PC) data transmission. Request ASCII string represents current frequency in GHz and its format must be 000.00 (6 chars, fixed point with leading and trailing zeroes). For example frequency 62.50 GHz represents with string 062.50 gives request byte sequence 30 36 32 2E 35 30 (HEX values). It has not have terminator like [CR LF]. Any excess byte will cause an error! DPM answer depends on units what power level is measured in. If measurements are performed in Watt units, the answer is: ASCII string with current frequency in the same format as in input string, 7-th character is separator space (20 Hex value), then goes the same string as power displayed in DPM: 000.00mW/0.000mW or 000.00uW/0.000uW. In other words device response is exactly the displayed string without any terminators (14 chars). Chars in pos. 4,7,14 are constant and can be used to check if response is correct. The first six chairs mean set frequency. The rest chairs do power value. Decimal point in power value is not fixed! 7

For dbm units the answer is: ASCII string with current frequency in the same format as in input string, 7-th character is separator space (20 Hex value), then goes the same string as power displayed in DPM: +/-00.00dBm/ or +/-0.000 dbm. In other words device response is exactly the displayed string without any terminators (17 chars). Chars in pos. 4, 7, 15, 16, 17 are constant and can be used to check if response is correct. The first six chairs mean set frequency. The rest chairs do power value. Decimal point in power value is not fixed! Examples: 1) 12.34 μw at frequency 62.50GHz gives answer string 30 36 32 2E 35 30 20 31 32 2E 33 34 75 57 (HEX values). 2) -10.25 dbm at frequency 75.50GHz gives answer string 30 37 35 2E 35 30 20 2D 31 30 2E 32 35 20 64 42 6D (HEX values). 8

Automatic setting of power meter operational modes: Note: If PC control mode has been already set symbol * presents in LCD. The DPM automatically turns to PC control mode if a command comes into DPM from a PC. To leave PC control mode press any key. Automatic setting of DPM operational modes can be provided through RS-232 or GPIB interface of a PC. - send to DPM control and display unit 6-bytes command through RS-232 or GPIB port: BCDEFG 1 byte is B ( 42 hex) to choose set mode C - 2-nd byte 1 for Tab1, 2 for Tab2 to choose point of measured power. C must be 1 in this model. D - 3-rd byte 0 or 1 or 2 or 3 or 4 or 5 or 6 or 7 to choose frequency step: 10MHz, 20MHz, 50MHz, 100MHz, 200MHz, 250MHz, 500MHz, 1GHz correspondingly E - 4-th byte 0 Watt units for power indication, 1 dbm units F - 5-th byte 0 PC control OFF, 31 PC control ON to choose control mode G - 6-th byte 0 Squeak OFF, 1 Squeak ON - to choose alarm squeak mode Symbols 0, 1, 7 corresponds to 30, 31 37 in HEX format. There is a possibility to read with PC current mode of DPM, for this: - send to DPM block 6-bytes command through RS-232 or GPIB port: AXXXXX, 1-st byte is A( 41 ) to choose check mode Bytes X from 2-nd to 6-th can have any symbols; The reply from DPM is ACDEFG, Symbol A as in the request. Bites from C to G as above. C - means Tab 1 or Tab 2 9

D - means frequency step E - means units of measurements: Watt or dbm F - means PC control ON or OFF. Must be ON G - means squeak ON or OFF For Example: 1) On request A12345 (41 31 32 33 34 35 in HEX value) DPM reports current settings: For example: Settings Tab 1, Frequency step 20MHz, dbm units, PC control ON, Squeak ON DPM gives answer string 41 31 31 31 31 31 31 2) On request B10000 (42 31 30 30 30 30 in HEX value) DPM sets following settings: Tab 1, Frequency step 10MHz, Watt units, PC control OFF, Squeak OFF Serial interface: Data format 8 data bits, no parity, 1 stop bit ( 8N1 ). Connection speed 1200 bps. Connection cable: Really only 3 wires are used; case ground recommended for safety. The power meter with GPIB interface requires MODEM cable. GPIB interface: The Serial interface GPIB card of ICS Electronics model 4806 tested with GPIB card AX5488 with default jumper settings. http://www.icselect.com/pdfs/4806_ds.pdf http://www.icselect.com/ Device is configured for proper operation. Factory default GPIB address - 4. DPM GPIB configuration and operation commands. Device is configured for proper operation, so the only thing to be changed in it's settings is GPIB address - we left factory default 4. 10

Command strings and responses given in apostrophes to separate them from spaces and comments. Really there mustn t be apostrophes. GPIB configuration Action Command string Warning Set new GPIB SYST:COMM:GPIB:ADDR 11' Do not address 11 Address will be changed after 30 msec delay. forget it! Set baud rate 1200, update UART 'SYST:COMM:SER:BAUD 1200;UP Device works only at baud rate 1200. Set baud rate 1200, update UART and 'SYST:COMM:SER:BAUD 1200;UP;BAUD? response: 1200 query the value Set RS232 timeout 2.5 sec 'SYST:COMM:SER:TIME 2500' Recommended value Set factory default 'CAL:DEF'!!! This set settings Baud=9600 Save current *SAV 0 settings GPIB operation Action Command string Warning Get power at frequency 081.25GHz 081.25 (format 000.00, 6 chars) response(after approx. 1sec delay): 081.25 2.345mW or 081.25 0.000uW (microwatts) Response string is exactly like string on DPM display. Decimal point in power value is not fixed. Terminator mode must be OFF (see demo source)* * To set proper terminator mode for DPM GPIB interface card the following driver function call is used (Pascal with AX5488 library): ibeol(gpib_address,1{out_mode=1},oeol,strlen(oeol), 1{in_mode=1},ieol); where oeol any string, ieol any char with mode=1 they are void. For other GPIB card function may differs see manual for your card driver. 11

Power Meter Operating: 1. Connect the Control and Display Unit of Power Meter and the Sensor. 2. Connect the 110 VAC adapter plug of DPM Control and display unit to a power point. Then put AC switch ON. Wait for loading the DPM: - Lines with number of software will appear on the screen. Fig.6. Fig.6 Loading DPM screen Then tests of power sensor and software are doing. Note: The 2620-110707 version supports two protocols for control through PC. ELVA - normally used with RS-232 interface SCPI with GPIB interface. List of SCPI commands is included in the manual below (see Appendix 1). Read pages 14-15 and make sure the right protocol has been set for control following. If the tests have been successfully passed screens as in Fig.7 and in Fig.8 are Fig.7 Test of power sensor has been done OK 12

Fig.8 Test of software has been finished and OK - If symbol Fa appears in screen as in Fig.9 and alarm squeak sounds it means that connection between DPM and Power Sensor is unreliable. Fig.9 Failed sensor tests screen In this case one must switch DPM OFF and disconnect Power Sensor. Then connect the Power Sensor properly with using screws on power sensor connector (DB-9) and switch the DPM Control and Display unit again. If it is necessary one should repeat the operation until the line Program OK (Fig.8) appears on screen. One can skip tests pressing any key. Next screen shows two lines with current settings of the DPM Control and display unit block. The settings are the same which was at the moment when the DPM was switched OFF at last session. 13

If it is necessary to set default settings one should keep the key 5 pressed during switching ON and release it after two alarm squeaks. Default settings are (Fig.10): upper line: Tab1, step 1, W lower line: SCPI Fig.10 Screen with default settings of DPM SCPI control format has been set The values mean: Tab 1 - mode 1. Only this mode is available for this model. Step 1 step 10 MHz (the smallest step) W - indication in Watt units (uw, mw). Local SCPI - PC control with SCPI protocol. The DPM indicator block can be controlled with PC using ELVA or SCPI protocol. Check which SCPI or ELVA control protocol has been set. It can be read when DPM starts. SCPI has been set if screen as in Fig. 10. Fig.11 ELVA control format has been set 3. To check current control protocol or change control protocol: -Press any key -Insert symbols 992 14

One of two types of screen appears: I Fig. 12 Current control format SCPI Fig. 13 Current control format ELVA Choose a) or b) below a) -Press key * if current control format satisfies b) -Press any key except * to change format. -Press key * if indicated control format satisfies The DPM Power meter is ready for operation if lines with frequency and power values are displayed like in Fig.14 Frequency of measured signal Measured power level #Mode (#Tab) Fig.14 Power meter is ready for measurements If display like on fig 15 appears (symbol * or #* or sign READY TO START ), as shown on the Fig 15, it means that DPM is in the automatic mode at the moment. To leave the mode one should press any key. 15

Fig 15. Power meter is in automatic mode 4 Choose measurement mode (Watt or dbm), for this: - press any key; - insert 997 code using keyboard - press 0 for choosing Watt mode - press any key, except * for choosing dbm mode - press * to leave the mode 5 Choose TAB Number (TAB1 or TAB2) (mode number), for this: - press any key; - insert 999 code using keyboard - press 1 for choosing TAB1 - press 2 for choosing TAB2 - press * to leave the mode ATTENTION: Only one mode (Tab1=Tab2) is provided in this DPM model type. 6 Choose control and squeak mode (squeak ON or squeak OFF), for this: 16

- press any key; - insert 996 code using keyboard - press consistently any key except 3 and * for choosing manual mode. Line Remote Off means manual mode. In this mode squeak is always ON. - press consistently any key except 3 and * for choosing control mode through RS-232 or GPIB interface of a PC without squeak. Line Remote On means RS- 232 or GPIB without squeak mode ON. - press consistently key 3 for choosing control mode through RS-232 or GPIB interface of a PC with squeak. Line Remote On # means RS-232 or GPIB interface with squeak mode ON. - - press * to leave the mode. Sign Remote READY TO START or two lines FREQUENCY/POWER appear in LCD (sign * or *# in right upper corner of LCD means set automatic mode (Fig 15.)). 7 Connect input of the sensor to a source of mm-wave CW power. 8 In manual mode 8.1 choose frequency step, for this: - press any key; - insert 998 code using keyboard; - press consistently any key, except * for choosing frequency step; Example: Symbols 50 means frequency step 0.50GHz; - press * to leave the mode. 8.2 Set frequency of measured signal in GHz, for this: - press any key to get input frequency mode. Keep the key pressed until underline sign appears. Presence of underline sign in LCD means frequency setting mode. - insert frequency. Underline shows what symbol is being set. Frequency format is XXX.XX GHz. All 5 figures must be entered. If right frequency value is not determined, the absolute value of measured power will be wrong because output signal of power sensor is frequency depended. 17

- use key * to shift the frequency down and key # to shift it up on one step. Frequency step is: 1GHz, 0.5GHz, 0.25GHz, 0.2GHz, 0.1GHz, 0.05GHz, 0.02GHz, 0.01GHz. How to set frequency step, read in the item 8.1 above. 8.3 Frequency value without underline sign in LCD means measuring mode. 8.4 Read the value of the measured power in LCD. 9. In automatic mode: 9.1 Connect PC with DPM RS-232 or GPIB port; 9.2 There is a possibility to check current mode of DPM as it written above, for this: - by using software for checking RS-232 or GPIB port send to DPM 6-byte command: 1 byte - A( 41 ) to choose check mode 2-6 byte - any meanings; 9.3 There is a possibility to set mode of DPM as it written above, for this: - send to DPM 6- through RS-232 or GPIB port byte command: 1 byte - B( 42 ) to choose set mode 2 byte 31 Mode TAB1, 32 Mode TAB2 to choose mode. Note: Only one mode (Tab1=Tab2) is provided in this DPM model. Use Tab1. 3 byte - 30 1, 31 2, 32 10, 33 10, 34 20, 35 25, 36 50, 37 100, - to choose frequency step 4 byte 30 Watt units, 31 dbm units to choose measurement mode 5 byte 30 PC control OFF, 31 PC control ON to choose control mode (manually or automatically) 6 byte 30 Squeak OFF, 31 Squeak ON - to choose alarm squeak mode 9.4 Run softwear; Use ICS 4086 data sheet if needful 10. To leave automatic mode and proceed to manual mode - press any key; 11. Use switch ON/OFF if one needs to reset the power meter. Note: Do not switch the power meter ON/OFF if input mm-wave power exists at power sensor input. 18

Power Sensors calibration E-band power sensor with DPM indicator block were calibrated at ELVA-1 lab with ELVA-1 s reference power meters. Calibration setup is shown in fig.16. POWER METER UNDER CALIBRATION REFERENCE POWER METER CONTROL PC POWER SENSOR POWER SENSOR Directional coupler (calibrated) Calibrated attenuator SWEEPING OSCILLATOR Fig.16 Power meter calibration setup A sweeping oscillator provides mm-wave signal within full operating bandwidth of the power sensors. MM-wave power was measured with reference power meter and power meter under calibration at the same time. The calibration is being done automatically with frequency step 0.2GHz. Correction factors are obtained and loaded into EEPROM memory of power sensor under calibration. Obtained test data of power level measured with two power meters (reference and calibrated power sensors) after the calibration are presented in Tables 1. Linearity tests of calibrated power sensors are presented in Tables 2. 19

E-BAND POWER SENSOR Table 1 F, GHz Reference power meter reading, uw Calibrated power meter reading, uw Error, % 60 14110 13900-1.4 63 16730 16440-1.7 69 15630 15730 0.6 72 20680 20590-0.4 75 17240 17170-0.4 77 4449 4500 1.1 80 7661 7719 0.7 83 5296 5372 1.4 86 10870 10910 0.4 90 14480 14490 0.1 Table 2 Set attenuation, db F, GHz 0 5 10 15 20 Input Power, dbm 60 13.0 8.0 2.9-1.9-6.9 Linearity Error, db 0 0.1-0.1-0.1 63 12.6 7.5 2.5-2.4-7.4 Linearity Error, db 0.1 0.1 0 0 69 12.2 7.1 2.1-2.8-7.8 Linearity Error, db 0.1 0.1 0 0 72 13.0 8.0 3.0-2.0-6.9 Linearity error, db 0 0 0-0.1 75 12.7 7.7 2.7-2.4-7.3 Linearity Error, db 0 0 0.1 0 77 7.2 2.2-2.7-7.7-12.6 Linearity error, db 0-0.1-0.1-0.2 80 9 3.9-1.1-6.2-11.2 Linearity Error, db 0.1 0.1 0.2 0.2 83 7.8 2.8-2.2-7.3-12.4 Linearity error, db 0 0 0.1 0.2 86 10.3 5.3 0.2-4.8-9.9 Linearity Error, db 0 0.1 0.1 0.2 90 11.8 6.7 1.7-3.2-8.2 Linearity error, db 0.1 0.1 0 0 20

Appendix 1 Control of DPM power meter with SCPI protocol Software version #110707 1. Switch DPM power meter ON. 2. Immediately after switching ON make sure the software version 110707 is used Software version 110707 is loading 3. Check if SCPI control format is set. It can be read when DPM starts SCPI control format has been set ELVA control format has been set To check current control format or change control format: -Press any key -Insert symbols 992 One of two types of screen appears: 21

Current control format SCPI Current control format ELVA Choose a) or b) below a) -Press key * if current control format satisfies b) -Press any key except * to change format. -Press key * if indicated control format satisfies 1. Commands SYST2 (system) List of commands of SCPI format Command Description Respond SYST2:*** syst2:beep:stat off Turn Buzzer off Buzzer does not sound (is off) when a command receives at remote mode syst2:beep:stat on Turn Buzzer on Buzzer sounds (is on) when a command receives at remote mode syst2:beep:stat? Query of Buzzer status on, Buzzer is on syst2:pres Default DPM settings: Tab1 Frq_step=1 (10 MHz) Indication in uw/mw 22 off, Buzzer is off

syst2:err? Manual control syst:beep stat off, aver:count 50, disp:enab off Query to type of last error After the command error bite gets 0 0, No error -100, Command error -128, Numeric data not allowed -365, Time out error SENS:*** sens:corr:tabl 1 Set mode Tab1 (for sensors with directional coupler only) sens:corr:tabl 2 Set mode Tab2 (for sensors with directional coupler only) sens:corr:tabl? Query of status Tab 1, Tab1 is set 2, Tab2 is set sens:freq [xxx.xx] Setting of frequency of measured signal examples: sens:freq 91 sens:freq 091 sens:freq 91.0 sens:freq 091.00 sens:freq? Query of set frequency 91.00 CALC:*** calc:aver:coun [1 250] Setting of number of measurement points averaging calc:aver:coun? Query of set number of averaging 50 UNIT:*** unit:pow dbm unit:pow w unit:pow? READ:*** read? fetc? Setting of indication of power level in dbm Setting of indication of power level in uw/mw Query of type of power measurement unit Start of measurements and receiving data Reading of result of last done measurement (without new 23 W, power level in uw/mw DBM, power level in dbm 0.185 UW, measured power level or -37.3 DBM, measured power level 0.185 UW, measured power level or

process of measurement) -37.3 DBM, measured power level DISP:*** disp:enab off disp:enab on Display does not refresh measurement information at REMOTE(RS_control) mode Display indicates actual measurement information at REMOTE(RS_control) mode disp:enab? Display operation status on, Display indicates actual data (is on) off, Display does not refresh data (is off) gtl Setting of manual control (Go To Local control) Notes: DPM display unit with GPIB interface used ICS Electronics 4806 board http://www.icselect.com/pdfs/4806_ds.pdf http://www.icselect.com/ The board uses commands SYSTem, STATus, CALibrate, DIAGnostic and all IEE-488.2 Сommon Commands Command of SYST2:*** type is used for DPM control Only brief format of commands is allowed. Example: sens:aver:coun 50 Entire format is not allowed: Example:sensor:average:counts 50 Format of a command allows using Capital or lower-case letters Command with forward colon : is wrong. Example: :disp:enab?. Correct disp:enab? All commands have to have symbol LF (line feed, 0xA) in the end Switching from Manual mode to Remote (RS_control) mode makes automatically if a command through GPIB/ RS-232 interface appears. There is symbol * in LCD (14-th symbol in 1-st line) if REMOTE mode is ON (despite if disp:enab? is off). Frequency format in command and respond is numerical. Format with 2 symbols after decimal point. Examples: 93.00, 105.20 Power level format with uw/mw or dbm units. Examples: 0.185 UW, 0.185 MW, -37.3 DBM. If set frequency value is out of admissible range, the value has not been accepted and changed and error appears -128, "Numeric data not allowed. Can be read upon query. Code of last error is kept in DPM and can be read with command syst2:err? After the command the error bite gets 0. The error byte gets 0 also if send commands: syst2:pres or gtl or DPM is switching ON. If REMOTE(RS_control) is on, switching of DPM off and next on makes disp:enab? off (i.e. Display does not refresh indicated data) 24