Electric vacuum switch, series PSE 100 E PSE 100 EC 8.0 63.0 13.6 PSE 100 E 8.0 63.0 2 metres approx. 1.0 Connecting hollow shaft A.P.* for tube int. dia. 2. mm 1.0 Connecting hollow shaft A.P.* for tube int. dia. 2. mm.0.0 Vacuum * A.P.: Atmospheric pressure Male connector M12 3-wire cable The vacuum switch with electric output, in series PSE 100 E, allows the vacuum level in the system to be checked by means of a patented system. It can be adapted to all electric automatic controller systems. The choice between the N.O. and N.C. function is made when wiring. Two versions: PSE 100 E and PSE 100 EC Compatible fluids All non-corrosive gases Switching capacity 250 V - 5 A with cable 125 V - 3 A with connector M12 Electrical connection Female connector M12 or 3-wire PVC cable, 2 m long Adjusting range -300 mb to -830 mb Accuracy 3% 125 mb Authorized overpressure 2 bars (destructive at 5 bars) Protection class IP 54 with hollow shaft connected - IP 40 without hollow shaft 165 g: PSE 100 E and 3 g: PSE 100 EC Electrical connection: CONNECTOR M12 2 1 3 4 1: Common 2: N.O. contact 3: 4: N.C. contact PCV CABLE (2 m long) Connection for version EC (M12): Straight PVC cable, 2 metres: ref. CD M12 Elbowed PVC cable, 2 metres: ref. CC M12 Elbowed PVC cable, 2 metres with : ref. CC M12L See page 32. PSE 100 E 1 Brown: Common White: N.O. contact Black: N.C. contact 1: Version - PVC cable, 2 metres long C Connector M12 3.2.2 56
Pneumatic vacuum switch, series PSE 100 P Vacuum threshold 8.0 51.6 Hollow shaft for tube int. dia. 2. mm Vacuum 1.0 N.O. or N.C. output.0 Pressure input The vacuum switch with pneumatic output, in series PSE 100 P, allows the vacuum level in the system to be checked by means of a patented system. This vacuum switch is available in two versions: N.O. version recommended for the «air saving» function on a venturi and N.C. version for the «safety» function (part present, etc.) and «grafcet signal». Two versions: N.O.and N.C. Compatible fluids All non-corrosive gases Operating pressure 2 to 6 bars Adjusting range -300 mb to -830 mb Accuracy 3% 80 to 100 mb Authorized overpressure 2 bars (destructive at 5 bars) 32 g Flow rate at 6 bars 0 Nl/min N.O. N.C. Pneumatic connection: 2: N.C. or N.O. output 1: Pressure input Special design: On request, factory preset version Optional fitting GVO on GVP range. PSE 100 P 1 3.2.2 1: Version NO Normally open (N.O.) NC Normally closed (N.C.) 5
Pneumatic vacuum switch, series PSE 100 PK 8 51.40 5.9 0 Signal output tube NO or NF 1 30 Vacuum threshold adjusting screw "Vacuum" input Pressure input tube Ø4 Applications : The vacuum switch with pneumatic output, in series PSE 100 PK, allows the vacuum level in the system to be checked by means of a patented system. Thanks to its high precision it is particulary suitable for the control of microleaks and the control of vacuum volumes of more than 1 litre. This vacuum switch is available in two versions: N.O. version recommended for the «air saving» function on a venturi and N.C. version for the «safety» function (part present, etc.) and «grafcet signal». Specifications : Two versions: N.O. and N.C. Compatible fluids All non-corrosive, non-lubricated gases Operating pressure 2 to 6 bars Adjusting range NC : -250 to 830 mb - NO : -350 to -880 mb Accuracy +/-10% NC : 10 mb - NO : 200 mb Authorized overpressure 2 bars (destructive at 5 bars)(on vacuum port) 32 g Flow rate at 6 bars 66 Nl/min N.O. N.C. Pneumatic connection: 2 : Output NC or NO 1 : Pressure input Special design: On request, factory preset version Optional fitting GVO on the GVP venturi range. 3.2.2 PSE 100 PK 1 1 : Version NO Normally open (N.O.) NC Normally closed (N.C.) 58
Electronic vacuum switch, series PSX 100 PSX 100 L PSX 100 LC8 30.9 84.4 30.9 8 62.9 8 62.9 5. 1 1 indicator threshold Threshold adjustment adjustment x 8 G 1/8 M indicator threshold Threshold adjustment adjustment x 8 G 1/8 M PVC cable (2 metres long) Connector M8 4 pins 5. Electrical connections: PVC CABLE (2 metres long) CONNECTOR M8 1: Brown (+24 V) 3: Blue (0V) 4: Black (Contact) 2 4 1 3 1: +24 V DC 2: - 3: Common 4: Output 1 Characteristics: PSX 100 L PSX 100 LC8 Compatible Fluids All non-corrosive, filtered, non lubricated gases Power supply 18-30 V CC regulated, pole changing protection Current draw < 20 ma Transistor outputs N.O. 125 ma at 24V CC Thermal error ±3 % measuring scale from 0 to 50 C Output display Threshold adjustment By potentiometer 3/4 turn 0 to 30% adjustment by potentiometer 3/4 turn EMC Industrial standard class B Material Polyacetal Operating temperature 0 to +50 C (storage -10 to +60 C) Protection class IP 50 Electrical connection PVC cable (2 m long) Connector M8 (4 pins) Pneumatic connection 1/8 Gas or 60g 30g Accessories: Straight and elbowed connector: see general catalogue page 32. Optional fitting GVO : réf. GVO PSX 100 PSX 100 1 Characteristics Measuring Overpressure range in Model bar bar PSX 100 0 / -1 +3 Contact outputs 1 contact output Connector M8 or Cable IP50 (2 m) 3.2.2 1: Electrical connection: L Cable 2 m LC8 Connector M8 59
Display-type vacuum switch, series PSA 100 C 8 58 12.50 1.30 16 9.20 26.80 Connector M8 4-pole threshold 1 threshold 2 Up 1/8 gas Menu selection mode Down Digital display of value in vacuum % The electronic vacuum switch in series PSA100C is the most efficient CO- VAL pressure measuring component. It allows easy installation on all machines and robots, etc., thanks to its compact lightweight design. In addition, it provides display after vacuum level with two contact outputs and independent adjustments. Every step has been taken to facilitate its use : programming on front panel, adjustment by threshold and the hysteresis of each output can be adjusted independently of the others. Characteristics: Electrical connection: Characteristics Measuring Overpressure range Model in bars in bar PSA 100 C 0 / -1 4 CONNECTOR M8 2 4 1 3 1: +24V DC 2: Anal./Output 2 3: Common 4: Output 1 Compatible fluids All non-corrosive gases, filtered, non-lubricated air Power supply 18-30 VDC. pole changing protection Current draw < 100 ma Transistor output PNP 125 ma 24 V DC, programmable N.O. or N.C. Output indicators Output 1 Red Output 2 Green Programming Key buttons Display In vacuum % (2-digit, -segment red, 8.5 mm) Electromagnetic Industrial standard, class B compliance Body material Polyacetal Protection IP 65 Electrical connection M8-connector Pneumatic connection 1/8 G or Impact strength 10 G XYZ Resolution display 1 % Resolution setting Accessories: Straight or elbowed connector, see page 32. Fitting on venturi, series GVP : GVO PSA 100 C, see page 28. PSA 1 2 configurable contact outputs Adjustable hysteresis M8 connector IP65 display 1: Range 100 0 / -1 C 60