RF Fundamentals Part 2 Spectral Analysis

Similar documents
Agilent Back to Basics. Spectrum Analysis Back to Basics. Presented by: Michel Joussemet

Utilizzo del Time Domain per misure EMI

Understanding RF and Microwave Analysis Basics

Spectrum Analyzer Training

Understanding Probability of Intercept for Intermittent Signals

Spectrum Analysis Back to Basics

8 Hints for Better Spectrum Analysis. Application Note

8 Hints for Better Spectrum Analysis. Application Note

Keysight Technologies N9320B RF Spectrum Analyzer

A year and a half after the first introduction of the PXA, Agilent is now introducing the world s highest performance mmw signal analyzer in April

Understanding New Pulse-analysis Techniques

Agilent N9320B RF Spectrum Analyzer

Chapter 5 Specifications

Interference Analysis and Spectrum Monitor Seminar

PXIe Contents SPECIFICATIONS. 14 GHz and 26.5 GHz Vector Signal Analyzer

ESA-E Series Spectrum Analyzer

Agilent ESA-L Series Spectrum Analyzers

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

Techniques for Characterizing Spurious Signals

Real-Time Spectrum Analysis (RTSA) -Triggering, and Signal Capture/Playback for Agile and Elusive Signals. Keysight Technologies

CXA X-Series Signal Analyzer, Multi-touch N9000B

100 Hz to 22. HP 8566B Spectrum Analyzer. Discontinued Product Support Information Only. Outstanding Precision and Capability

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Agenda. Spectrum Analyzer Basics

Measuring ACPR of W-CDMA signals with a spectrum analyzer

DSA700 Series Spectrum Analyzer

DSA800. No.1 RIGOL TECHNOLOGIES, INC.

3250 Series Spectrum Analyzer

Advances in RF and Microwave Measurement Technology

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

Keysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators. Application Note

GA GHz. Digital Spectrum Analyzer

Keysight Technologies

PXA Configuration. Frequency range

Advanced RF Measurements You Didn t Know Your Oscilloscope Could Make. Brad Frieden Philip Gresock

Specification RIGOL. 6 Specification

GET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals. Copyright 2001 Agilent Technologies, Inc.

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

Agilent 8560 E-Series Spectrum Analyzers

Advances in RF and Microwave Measurement Technology

Measuring Non-linear Amplifiers

Specifications Guide

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Agilent CSA Spectrum Analyzer

Introduction. In the frequency domain, complex signals are separated into their frequency components, and the level at each frequency is displayed

Keysight Spectrum Analyzer Option (090/S93090xA) for PNA/PNA-L/PNA-X/N5290A/N5291A

Agilent Spectrum Analysis Basics. Application Note 150

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software

Keysight X-Series Signal Analyzers

Spectrum Analyzers R3132/3132N/3162 R3132/3132N/3162. Low cost, high performance. General-Purpose Spectrum Analyzer Adaptable to Various Applications

A Guide to Calibrating Your Spectrum Analyzer

The Value of Pre-Selection in EMC Testing. Scott Niemiec Application Engineer

Appnote - Realtime Spectrum Analyzer vs Spectrum Analyzer

Keysight Technologies FieldFox Handheld Analyzers

GA GHz. Digital Spectrum Analyzer

S3503 Series Signal/Spectrum Analyzer Datasheet

Agilent N9340A Handheld Spectrum Analyzer

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Spectrum Analysis

Digital Spectrum Analyzer GA40XX Series

Understanding Low Phase Noise Signals. Presented by: Riadh Said Agilent Technologies, Inc.

Agilent N9343C Handheld Spectrum Analyzer (HSA)

AV4051A/B/C/D/E/F/G/H Signal/Spectrum Analyzer

Analyze Agile or Elusive Signals Using Real-Time Measurement and Triggering Ben Zarlingo, Agilent Technologies Inc.

Agilent E7400A Series EMC Analyzers

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

RF Measurements You Didn't Know Your Oscilloscope Could Make

Keysight X-Series Signal Analyzers

CXA X-Series Signal Analyzer N9000A

Addressing the Challenges of Wideband Radar Signal Generation and Analysis. Marco Vivarelli Digital Sales Specialist

Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface

Development of high cost performance signal analyzer MS2830A -044/045

Spectrum and signal analyzers for every requirement an overview

EMC Training. Ing Angelo Cereser Mobile:

HP 8560 E-Series Spectrum Analyzers Technical Specifications

Spectrum Analyzers 2680 Series Features & benefits

Satellite Communications: Part 4 Signal Distortions & Errors and their Relation to Communication Channel Specifications. Howard Hausman April 1, 2010

Keysight Technologies Spectrum Analysis Basics. Application Note 150

Product Overview. Main Characteristics. (3Hz~4GHz/9GHz/13.2GHz/18GHz/26.5GHz)

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Spectrum Analysis

DSA-815 Demo Guide. Solution: The DSA 800 series of spectrum analyzers are packed with features.

N9000A CXA X-Series Signal Analyzer 9 khz to 3.0 GHz or 7.5 GHz. Data Sheet

Agilent 8360B/8360L Series Synthesized Swept Signal/CW Generators 10 MHz to 110 GHz

GAO-SAU-105 Spectrum Analyzer with Wide Frequency Range

Agilent X-Series Signal Analyzer

Agilent X-Series Signal Analyzer

Understanding Level Accuracy specifications and techniques in Spectrum Analysers.

DSA800. No.2 RIGOL TECHNOLOGIES, INC. All-Digital IF Technology 9 khz GHz Frequency Range

TRANSCOM Manufacturing & Education

R&S FSWP Phase Noise Analyzer Specifications

Misure di pre-compliance EMI

Measurement of Digital Transmission Systems Operating under Section March 23, 2005

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation

Keysight Technologies N9051B Pulse Measurement Software X-Series Signal Analyzers. Technical Overview

Successful Modulation Analysis in 3 Steps. Ben Zarlingo Application Specialist Agilent Technologies Inc. January 22, 2014

Lab Assignment #3 Analog Modulation (An Introduction to RF Signal, Noise and Distortion Measurements in the Frequency Domain)

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

Agilent N9320B RF Spectrum Analyzer

Transcription:

Spectral Analysis Dec 8, 2016 Kevin Nguyen Keysight Technologies

Agenda Overview Theory of Operation Traditional Spectrum Analyzers Modern Signal Analyzers Specifications Features Wrap-up Page 2

Overview What is Spectrum Analysis Passive Receiver Display and measure amplitude versus frequency Separate or demodulate complex signals into their base components (sine waves) Page 3

Overview Frequency vs Time Domain Amplitude (power) Time domain Measurements (Oscilloscope) Frequency Domain Measurements (Spectrum Analyzer) Page 4

Overview Types of Measurements Available Frequency, power, modulation, distortion, and noise Spectrum monitoring Spurious emissions Scalar network analysis Noise figure & phase noise Harmonic & intermodulation distortion Analog, digital, burst, & pulsed RF modulation Wide bandwidth vector analysis Electromagnetic interference Measurement range: -172 dbm to +30 dbm Frequency range: 3 Hz to 1.1 THz Modulation Spur Search Noise ACP Page 5

Overview Different Types of Analyzers Swept Analyzer A Filter 'sweeps' over range of interest LCD shows full spectral display f 1 f 2 f Page 6

Overview Different Types of Analyzers A FFT Analyzer Parallel filters measured simultaneously LCD shows full spectral display f 1 f 2 f Page 7

Analyzer Definitions Spectrum Analyzer: A spectrum analyzer measures the magnitude of an input signal versus frequency within the full frequency range of the instrument. The primary use is to display and measure Amplitude vs. Frequency of known and unknown RF and Microwave signals. Page 8

Analyzer Definitions Vector Signal Analyzer: A vector signal analyzer measures the magnitude and phase of an input signal at a single frequency within the IF bandwidth of the instrument. The primary use is to make inchannel measurements, such as error vector magnitude, code domain power, and spectral flatness, on known signals. Page 9

Analyzer Definitions Signal Analyzer: A signal analyzer provides the functions of a spectrum analyzer and a vector signal analyzer. Page 10

Agenda Overview Theory of Operation Traditional Spectrum Analyzers Modern Signal Analyzers Specifications Features Wrap-up Page 11

Theory of Operation Swept Spectrum Analyzer Block Diagram RF Input Attenuator Mixer IF Gain IF Filter (RBW) Envelope Detector Input signal Pre-Selector or Low Pass Input Filter Local Oscillator Log Amp Video Filter Sweep Generator Crystal Reference Oscillator ADC, Display & Video Processing Page 12

Amplitude Theory of Operation Display Terminology Reference Level Start Frequency Stop Frequency Frequency Span Center Frequency Page 13

Theory of Operation Mixer Mixer fsig 1.5 GHz RF LO IF fsig fsig - flo flo fsig + flo 3.6 GHz flo 6.5 GHz Page 14

Theory of Operation IF Filter (Resolution Bandwidth (RBW) IF Filter Input Spectrum IF Bandwidth (RBW) Display A B C Page 15

Theory of Operation Envelope Detector Before detector After detector Envelope Detector Page 16

Theory of Operation Envelope Detector and Detection Types Envelope Detector Digitally Implemented Detection Types Bins/Buckets (Sweep Points) Positive Detection: largest value in bin displayed Negative detection: smallest value in bin displayed Sample detection: middle value in bin displayed Other Detectors: Normal (Rosenfell), Average (RMS Power) Page 17

Theory of Operation Average Detector Type Envelope Detector Positive Peak Detection Volts x bin Sample Detection x x Negative Peak Detection Time Power Average Detection (rms): Square root of the sum of the squares of ALL of the voltage data values in the bin divided by 50Ω Page 18

Theory of Operation Video Filter (Video Bandwidth VBW) Video Filter Page 19

Theory of Operation How it All Works Together 3 GHz Spectrum Analyzer Signal Range LO Range fs flo - fs flo flo + fs 0 1 2 3 GHz fs IF Filter Input Mixer 0 1 2 3 4 5 6 3.6 6.5 Detector 3.6 Sweep Generator f IF A LO flo 3 4 5 6 3.6 6.5 GHz 0 1 2 3 (GHz) LCD Display f Page 20

Modern Signal Analyzer Block Diagram Pre-amp Analog IF Filter Digital IF Filter Digital Detectors ADC FFT Attenuation Swept vs. FFT Digital Log Amp YIG Replaced by Page 21

Agenda Overview Theory of Operation Traditional Spectrum Analyzers Modern Signal Analyzers Specifications Features Wrap-up Page 22

Key Specifications Safe spectrum analysis Frequency Range Accuracy: Frequency & Amplitude Resolution Sensitivity Distortion Dynamic Range Page 23

Specifications Definitions Specifications describe the performance of parameters covered by the product warranty (temperature = 0 to 55 C, unless otherwise noted). Typical values describe additional product performance information that is not covered by the product warranty. It is performance beyond specification that 80 % of the units exhibit with a 95 % confidence level over the temperature range 20 to 30 C. Typical performance does not include measurement uncertainty. Nominal values indicate expected performance, or describe product performance that is useful in the application of the product, but is not covered by the product warranty. Page 24

Specifications Practicing Safe Spectrum Analysis - Safe Hookups to RF Use best practices to eliminate static discharge to the RF input! Do not exceed the Damage Level on the RF Input! Do not input signals with DC bias exceeding what the analyzer can tolerate while DC coupled!! 0 V DC MAX +30dBm (1W) MAX Page 25

Specifications Frequency Range Description Specifications Internal Mixing Bands 0 3 Hz to 3.6 GHz 1 3.5 to 8.4 GHz 2 8.3 to 13.6 GHz 3 13.5 to 17.1 GHz 4 17 to 26.5 GHz 5 26.4 to 34.5 GHz 6 34.4 to 50 GHz Page 26

Specifications Accuracy: Frequency & Amplitude - Components which contribute to uncertainty are: Input mismatch (VSWR) RF Input attenuator (Atten. switching uncertainty) Mixer and input filter (frequency response) IF gain/attenuation (reference level accuracy) RBW filters (RBW switching uncertainty) Log amp (display scale fidelity) Reference oscillator (frequency accuracy) Calibrator (amplitude accuracy) Page 27

Amplitude Specifications Accuracy: Absolute vs Relative Absolute Amplitude in dbm Relative Amplitude in db Absolute Frequency Frequency Relative Frequency Note: Absolute accuracy is also relative to the calibrator reference point Page 28

Specifications Accuracy: Frequency Response Signals in the Same Harmonic Band +1 db 0-1 db BAND 1 Absolute amplitude accuracy Specification: ± 1 db Relative amplitude accuracy Specification: ± 2 db Page 29

Specifications Accuracy: Frequency Readout Accuracy Frequency Readout Accuracy = ± [(Marker Frequency x Frequency Reference Accuracy) + (0.1% x Span) + (5% x RBW) + 2Hz + (0.5 x Horizontal Resolution)] = ± [(time since last adjustment x aging rate) + temperature stability + calibration accuracy] = 1.55 x 10-7 / year = span / (sweep points 1) Example: 1 GHz Marker Frequency, 400 khz Span, 3 khz RBW, 1000 Sweep Points Calculation: (1x10 9 Hz) x (±1.55x10 7 /Year) 400kHz Span x 0.1% 3kHz RBW x 5% 2Hz + 0.5 x 400kHz/(1000-1) Total uncertainty = 155Hz = 400Hz = 150Hz = 202Hz = ±907Hz Utilizing internal frequency counter improves accuracy to ±155 Hz The maximum number of sweep points for the X-Series Analyzers is 40,001 which helps to achieve the best frequency readout accuracy Page 30

Specifications Resolution What Determines Resolution? Resolution Bandwidth RBW Type and Selectivity Noise Sidebands Page 31

Specifications Resolution: Resolution Bandwidth Input Spectrum Mixer 3 db BW 3 db Envelope Detector LO IF Filter/ Resolution Bandwidth Filter (RBW) Sweep RBW Display Page 32

Specifications Resolution: Resolution Bandwidth 10 khz RBW 3 db 10 khz Determines resolvability of equal amplitude signals Page 33

Specifications Resolution: RBW Selectivity or Shape Factor 3 db 3 db BW 60 db 60 db BW Selectivity = 60 db BW 3 db BW Determines resolvability of unequal amplitude signals Page 34

Specifications Resolution: RBW Selectivity or Shape Factor RBW = 1 khz Selectivity 15:1 RBW = 10 khz 3 db 7.5 khz Distortion Products 60 db 60 db BW = 15 khz 10 khz 10 khz Page 35

Specifications Resolution: RBW Type and Selectivity ANALOG FILTER Typical Selectivity Analog 15:1 Digital 5:1 DIGITAL FILTER RES BW 100 Hz The X-series RBW shape factor is 4.1:1 SPAN 3 khz Page 36

Specifications Resolution: RBW Determines Sweep Time Meas Uncal Swept too fast The penalty for sweeping too fast is an uncalibrated display. Page 37

Resolution: RBW Type Determines Sweep Time Analog RBW Digital RBW 280 sec 2.3 sec Page 38

Specifications Resolution: Noise Sidebands Phase Noise Noise sidebands can prevent resolution of unequal signals. Page 39

Specifications Sensitivity/DANL RF Input Mixer Res BW Filter Detector LO Sweep A spectrum analyzer generates and amplifies noise just like any active circuit. Page 40

Specifications Sensitivity/DANL 2.2 db Sensitivity is the smallest signal that can be measured. Page 41

Specifications Sensitivity/DANL: IF Filter (RBW) Displayed noise is a function of IF filter bandwidth: noise decreases as bandwidth decreases. 100 khz RBW 10 db 10 db 10 khz RBW 1 khz RBW Page 42

Specifications Sensitivity/DANL: Mixer Video BW Filter or Trace Averaging Video BW or trace averaging smoothes noise for easier identification of low level signals. Page 43

Specifications Sensitivity/DANL: Input Attenuation Effective level of displayed noise is a function of RF input attenuation: signal to noise ratio decreases as RF input attenuation increases. signal level 10 db Attenuation = 10 db Attenuation = 20 db Page 44

Specifications Dynamic Range The ratio, expressed in db, of the largest to the smallest signals simultaneously present at the input of the spectrum analyzer that allows measurement of the smaller signal to a given degree of uncertainty. Dynamic Range Page 45

SIGNAL-TO-NOISE RATIO, dbc. Specifications Displayed DANL per RBW and Mixer Input Power 0-20 -40 Displayed Noise in a 1 khz RBW -60-80 -100 Displayed Noise in a 100 Hz RBW -60-30 0 +30 POWER AT MIXER = INPUT - ATTENUATOR SETTING, dbm Page 46

Specifications Distortion: Mixers Frequency Translated Signals Resultant Signal To Be Measured Mixer Generated Distortion Page 47

Specifications Distortion: Second and Third Order Distortion products increase as a function of fundamental's power. Power in db 2f - f 3 f 1 2 1 2 f 3 2f 2 - f 1 Power in db 2 3 f 2f 3f Two-Tone Intermod Harmonic Distortion Third Order: 3 db/db of Fundamental Second Order: 2 db/db of Fundamental Page 48

DISTORTION, dbc Specifications Distortion: A Function of Mixer Level 0-20 -40 Second Order -60-80 -100 Third Order -60-30 0 +30 TOI POWER AT MIXER = INPUT - ATTENUATOR SETTING dbm SHI Page 49

SIGNAL-TO-NOISE RATIO, dbc. Specifications Dynamic Range (DANL, RBW, Distortion) Dynamic range can be presented graphically.. -20-40 - 60-80 Maximum 2nd Order Dynamic Range Maximum 3rd Order Dynamic Range - 100-60 Optimum Mixer Levels - 30 0 TOI SOI +30 POWER AT MIXER = INPUT - ATTENUATOR SETTING dbm Page 50

Specifications Dynamic Range Dynamic range for spur search depends on closeness to carrier. Dynamic Range Limited By Noise Sidebands dbc/hz Dynamic Range Limited By Compression/Noise Noise Sidebands Displayed Average Noise Level 100 khz to 1 MHz Page 51

Specifications Dynamic Range vs Measurement Range DISPLAY RANGE 100 db @ 10 db/div (200 db @ 20dB/Div) INCREASING RBW OR ATTENUATION +30 dbm +3 dbm MEASUREMENT RANGE 195 db SIGNAL/NOISE RANGE 158 db -40 dbm SIGNAL /3rd ORDER DISTORTION 115 db range SIGNAL/ 2nd ORDER DISTORTION 105 db RANGE MAXIMUM POWER LEVEL MIXER COMPRESSION THIRD-ORDER DISTORTION (Dynamic Range) SECOND-ORDER DISTORTION -50 dbm (Dynamic Range) NOISE SIDEBANDS 0 dbc (Dynamic Range) SIGNAL/NOISE SIDEBANDS -129 dbc @ 10kHz OFFSET -155 dbm (1 Hz BW & 0 db ATTENUATION) -165 dbm with preamp MINIMUM NOISE FLOOR (DANL) Page 52

Agenda Overview Page 53 Theory of Operation Traditional Spectrum Analyzers Modern Signal Analyzers Specifications Features Wrap-up

N O I S E F L O O R E X T E N S I O N ( N F E ) Features Sensitivity/DANL: Noise Floor Extension Standard With NFE Standard With LNP With NFE The PXA combines real-time measurement processing with an unprecedented characterization of the analyzer s own noise to allow that noise to be accurately removed from measurements. The improvement from noise floor extension varies from RF to millimeter wave. At RF, from about 3.5 db for CW and pulsed signals to approximately 8 db for noise-like signals, and up to 12 db or more in some applications. DANL at 2 GHz is 161 dbm without a preamp and 172 dbm with the preamp. Page 54

Features Sensitivity/DANL: Low Noise Path (LNP) At microwave frequencies any sort of signal routing or switching results in signal path loss. Preamplifiers can compensate for this loss and improve signal/noise for small signals, but they can cause distortion in the presence of larger signals LNP allows the lossy elements normally found in the RF input chain to be completely bypassed for highest sensitivity without a preamplifier LNP allows measurements of small spurs w/o speed penalty imposed by narrow RBW that would otherwise be needed for adequate noise level Page 55

Features Sensitivity/DANL: Low Noise Path Block Diagram Page 56

Features Fast Sweep Processing By adjusting the phase response of the RBW filters, the LO can be swept at a faster rate without creating errors. ~36 seconds ~0.63 seconds Sweep without fast sweep enabled Sweep with fast sweep enabled Page 57

Data Acquisition and Processing Swept Mode Swept LO A swept LO w/ an assigned RBW. Covers much wider span. Good for events that are stable in the frequency domain. Magnitude ONLY, no phase information (scalar info). Captures only events that occur at right time and right frequency point. Lost Information Lost Information Lost Information Freq Data (info) loss when LO is not there. Time Page 58

Data Acquisition and Processing Vector Signal Analyzer Mode Parked LO A parked LO w/ a given IF BW Collects IQ data over an interval of time. Performs FFT for time- freqdomain conversion Captures both magnitude and phase information (vector info). Data is collected in bursts with data loss between acquisitions. Lost Information Analysis BW Freq Meas Time or FFT Window Length Meas Time or FFT Window Length Time Page 59

Data Acquisition and Processing Real-Time Mode A parked LO w/ a given IF BW Parked LO Collects IQ data over an interval of time. Data is corrected and FFT d in parallel Vector information is lost Advanced displays for large amounts of FFT s Freq Acquisition or slice time Acquisition or slice time Real Time Processing Some data may still be lost Time Real-time BW Page 60

Real-Time Spectrum Analysis Swept vs RTSA From this...to this Page 61

Real-Time Displays Density Spectrum Spectrogram Power vs Time Also know as Histogram Persistence Color indicates number of hits Screen typically updates every 30 ms Persistence can be manual or infinite Accumulate all FFT s to a single trace Apply detector Superimposed on the density display Used for marker operations Real-time spectrum slices no gaps 10,000 spectrogram traces available Scroll through stored traces Use markers on and between traces PvT over configurable range Gapless time data transformed to frequency domain Different displays available Level based trigger available Page 62

P R O B A B I L I T Y OF I N T E R C E P T D E T E C T L OW L E V E L S I G N A L S W I T H P R E C I S I O N Real-Time Spectrum Analysis Application: Detect Low Level Signals with Precision Short burst comms, LPI radar systems make it very difficult to analyze jamming & interference Communication jamming needs to be done very quickly for adaptive threats POI of 3.57 usec for 100% POI with full amplitude accuracy to catch the most elusive signals Excellent noise performance at X-band further improves POI Page 63

Features Trace Zoom Allows you to zoom in on your trace data Same trace in both screens, but bottom screen shows close up view with fewer points Great to look more closely at high-density traces Page 64

Scalability Multi-Channel, Higher Speed/Throughput, Smaller Footprint Page 65

Extend Frequencies to 325GHz and Beyond Better close-in phase noise performance than internallymixed 67 GHz analyzers! Supported measurements: Spectrum analysis PowerSuite one-button power measurements N9068A phase noise measurement application 89600A VSA Supported external mixers: M1970V/E/W 11970 Series OML Inc. VDI Page 66

Wide Analysis Bandwidth Modern designs demand more bandwidth for capturing high data rate signals and analyzing the quality of digitally modulated bandwidths. Aerospace and Defense Radar: chirp errors & modulation quality Satellite: capture 36/72 MHz BWs with high data rates Military Communications: capture high data rate digital comms & measure EVM Emerging Communications WLAN, 802.16 (wireless last mile), mesh networks Measure EVM on broadband, high data rate signals Cellular Communications W-CDMA ACPR & multicarrier pre-distortion High dynamic range over 60 MHz BW to see low level 3 rd order distortion for 4 carrier pre-distortion algorithms Page 67

RF Measurement Resources Keysight RF Learning Center www.keysight.com/find/klc Webcast Recordings Application Notes AN 150 Spectrum Analysis Basics 8 Hints for Better Spectrum Analysis 10 Hints for Making Better Noise Figure Measurements Videos Register for Future Webcasts Page 68