DLPlus. Dado and Skirting trunking LIMOGES Cedex. Phone : Fax :

Similar documents
DLP-S Trunking LIMOGES Cedex. Phone : Fax :

Snap-on Aluminium trunking. Number(s) : /13/17/19/22/24/28/30/34/36/40/42,

Trunking ZH with performances specific to fire: Low-Fire Hazard

Trunking with performances specific to fire: Low-Fire Hazard

Raised Floor system LIMOGES Cedex. Phone : Fax :

Flush Floor system LIMOGES Cedex. Phone : Fax :

Cable Management Solutions with DLP TM

General catalogue Export SMOUTS ARCHITECTEN

DLP mini trunking. DLP U-PVC trunking system mini-trunking system. DLP U-PVC trunking system and accessories 80 x 50. Comfortable implementation

Powerlink Plus Technical

colour Choose your more information Snap-on dlp trunking Snap-on DLP trunking Mechanisms for snap-on DLP trunking

IP30 floor Box wooden floors

Cablelink Plus Flush Technical

Ultra-efficient installation solutions

Trunking. light grey in U23X. Industrial Catalogue

Pinnacle Technical. Bench and Shelf Trunking. cable management perimeter and distribution. Features.

100% HALOGEN FREE TRUNKING SYSTEM

OptiLine 45 Floor boxes

Norwich Technical. Trunking PERIMETER AND DISTRIBUTION. Description CABLE MANAGEMENT. Colour: White only. Material: PVCu. mkelectric.co.

Prestige 2Com Technical

TRUNKING TRUNKING & MINI TRUNKING

ConnectionSolutions 4Workplaces. general catalogue

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

150mm to 200mm. With box in comp 2 2 = 1535mm² total area 2 = 691mm² 45% space factor. C. & C. Marshall Ltd.

Risk Assessment & Safe Working Practice

Workstation solutions

PRESTIGE 3D COMPACT RANGE INTRODUCTION PERIMETER AND DISTRIBUTION FEATURES & BENEFITS CABLE MANAGEMENT

Ega Industrial Technical

ConnectionSolutions 4Workplaces. general catalogue

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Trunking Guide. Colour List... W White M Magnolia B Black. shape & size (wxh) colours available

OptiLine 70 Trunking Product Overview Catalogue. Simple, modular, flexible.

Single phase meter with direct connection and pulse or Modbus RS485 output

OptiLine 45. The 45 direct Click-in installation system

List of Contents. Trunking systems. Selection of surface finish. Equipotential bonding. Cable ladders. Cable trays/ luminaire rails.

Junction boxes. Surface mounting - IP44 - IP55 - IP56 TECHNICAL CHARACTERISTICS

Cable Cover Guide. Color List... W White B Black P Premium Wood (stainable Floor Trim only) shape & size (wxh) colors available

Marshall Tufflex. Cable Management. Steel Trunking Systems

Warwick PVC Perimeter Trunking Systems

REHAU PROFILA BENCH TRUNKING INSTALLATION GUIDELINES. Building Solutions Automotive Industry

3-phase meter with direct connection and pulse or Modbus RS485 output

LEXUS LS460/600h/L INSTALLATION MANUAL FRONT HALF SPOILER. USF40/41 UVF45/46 (2012y~) ATTENTION WALD. INTERNATIONAL ATTENTION

GENERAL CATALOGUE. Connectivity for workplaces

Busbar and Modular Wiring Systems

Innovative Cable Management. Supplied by

CI/SfB. Marshall-Tufflex. (62) In6. Twin165 Trunking

(1,5 modules per pole)

Trunkingxxxxxx. aluminium colour U23X. Industrial Catalogue

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Wiring ducts Easily allows for organization, pulling and separation of cables

Technical Data Sheet Standard Sundeala FRB

Single Pole Switch. BR - White

Technical guide. The technical guide provides all the additional information you need on our cable management products.

SECTION BUILDING WIRE AND CABLE

PRESTIGE 3D ANTIBAC BLUE

Setting Standards Connectors M 16

Slotted trunking halogen free

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

CONTENTS. Hammerscrews White Zinc Plated 2 Hammerscrews Stainless Steel A Nylon Frame Anchors Yellow Zinc Plated 3 Nylon Plug 3

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

The new tehalit.sl skirting trunking Devices installed in style

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

SECTION ELECTRICAL IDENTIFICATION

05/11. CI/SfB (22) fire & sound. tenon. A cost effective performer.

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

Drywall, Wood and Truss Uplift

IPC 704. Signal conditioner FEATURES. For CA piezoelectric accelerometers and CP dynamic pressure transducers

CURVED TO PERFECTION. Range of upvc Three Compartment Trunking

Standard Halogen Light

FLATFROG MULTITOUCH 3200

Full-motion Wall Mount

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

Datasheet - ZQ Pull-wire emergency stop switches / ZQ 700

Ega Mini Trunking, Communication & Red Alert Trunking

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

Premier. cable management perimeter and distribution

Sport-Thieme Handball Goal, 3x2 m, Free-Standing or socketed

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

ConnectionSolutions 4Workplaces. general catalogue

ALPHA DIN Wall-Mounted. Distribution Boards

Resistance Thermometers Model Series TR7X0, Sheathed Design

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

Answer Power Beam and Boundary Screen

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

Simply versatile: Rapid 80 device installation trunking

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

Installation Guide. Rockfon Eclipse

Cable Management System. Metal Raceway Product Range

rondo exangle drywall finishing sections

Inductive sensor slot-type SI2-K08-AP7

Capacitive Proximity Sensor

GSE INTEGRATION INSTALLATION MANUAL For photo-voltaic systems partially covering the roof

TRASER-6. Concealed hangers. INDAUX s TRASER-6 cabinet hanger offers máximum simplicity, adjustment and resistance. Available in a non-tool version.

Sport-Thieme. Handball Goal. Assembly instruction. 3x2 m, without net brackets, in ground sockets

Room Temperature Controllers. for heating and cooling systems

Transcription:

87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 DLPlus CONTENTS PAGES 33744 33664 33745 33670 1.Range 80/120x20 1 to 2 2.Accessories 80/120x20 2 to 3 3.Range 140x35 4 4.Accessories 140x35 4 to 5 5.Technical characteristics 6 6.Material characteristics 6 33746 Dado trunking 80x20 1. RANGE 80/120x20. DLP Dado trunking offers: - the distribution, the protection and the derivation of various cables in an electrical installation. - trunkings, finishing accessories (end cap, cover joint, interior angle, exterior angle, flat angle, derivation) - all the easy ways/advantages for the installation. - to comply with the norm NF EN 50085-2-1, safety and technical performance. - a flexibility with the installation and maintenance: 1.1. Dado trunking 2 compartments, 1 cover ref. 030069/89 1. RANGE 80/120x20 (continued) 1.1. Dado trunking 2 compartments, 1 cover ref. 030069/89 Dimensions. Wiring capacity : Without central partition 80x20 ref. 030069 With central partition 120x20 ref. 030089 Trunking 80x20 Section in mm² /compartiment Câble Ø Max in mm Delivered in length of 2m. 2 compartments for the distribution of mains and extra low voltage possible to add 2 compartments with partitions ref 30867. Assembly of the body and covers by clips (disassembling with the assistance tool ex: screwdriver) Fixing by: - adhesive for glue gun ref 30949 - wall plugs for immediate fixing (without screw nor nail ref. 30899) - DLP rapid wall plug ref. 30897 (for 10mm min. plasterboard walls at least 20 mm away from a concrete surface. For fixing DLP plastic trunking in a single operation. - screw, nails Cutting with: - DLP cutting unit ref 30698, for cutting all plastic trunking (avoids vibration when cutting bases and covers) 1 350 14 2 500 2x14 3 180 7 4 191 8 5 320 15 6 180 7 Trunking 120x20 Section in mm² /compartiment Câble Ø Max in mm 1 350 14 2 1020 4x14 3 180 7 4 191 8 5 800 15 6 180 7 1 / 6

1. RANGE 80/120x20 (continued) 1.1. Dado trunking 2 compartments, 1 cover ref. 030069/89 Wiring capacity (continued) 80x20 1.5 mm² 2.5 mm² 4 mm² 6 mm² UTP FTP Cat. 6 1 21 15 13 10 6 2 30 22 19 14 9 3 10 8 7 5 3 4 11 8 7 5 3 5 19 14 12 9 6 6 10 8 7 5 3 120x20 1.5 mm² 2.5 mm² 4 mm² 6 mm² UTP FTP Cat. 6 1 21 15 13 10 6 2 61 45 40 29 20 3 10 8 7 5 3 4 11 8 7 5 3 5 48 35 31 23 15 6 10 8 7 5 3 1.2. clip on separation partition ref. 030867. 2. ACCESSORIES 80/120x20 (continued) 2.2. Internal angle ref. 033745/033665. Internal angle allows: Variable internal angles of 60 with 120. 033745 80x20 033665 120x20 2.3. External angle ref. 033746/033666. For the separation of various types of currents allows (sector, telephone, data processing ) Assembly with the trunking 80/120x20 by clips. Delivered in length of 2m White Color. 2. ACCESSORIES 80/120x20. 2.1. End cap ref.033744/74. External angle allows: Variable external angles of 60 with 120. 033746 80x20 033666 120x20 2.4. Cover joint ref. 033668. Allows to block the end of the trunking: - respect of the protection degree - improvement of aesthetics (covering of the cut) - left or right end cap. 033744 80x20 033774 120x20 - the junction end to end of two covers - to improve aesthetics (covering of the cut) Assembly of the joint by fitment and screwing To use with trunking 80x20 and 120x20 2 / 6

2. ACCESSORIES 80/120x20 (continued) 2.5. Convection heater outlet ref.033664. For end cap cap (right or felt) : 2. ACCESSORIES 80/120x20 (continued) 2.7. Flat junction/flat angle ref. 033670. For flat junction : Allows the flat junction of two same sections trunkings (80 or 120x20) End cap for junction with mini-trunking up to 75x20 For flat angle : For heating or air-conditionning : Allows the flat angle (right or felt) between trunkings (80 or 120x20) with mini-trunking up to 75x20 Can be used as cable outlet for convection heater or airconditionning with mini-trunking up to 75x20 - respect of the protection degree - improvement of aesthetics (covering of the cut) - left or right end cap. To use with trunking 80x20 and 120x20 (delivered with adaptors) 2.8. Flat angle ref. 033747/033667. To use with trunking 80x20 and 120x20 (delivered with adaptors) 2.6. Flat junction to floor duct ref. 032806. The junction in flat angle of two same sections allows: Assembly on the body by clipsage. To tap-off to floor duct ref. 032800. To use with trunking 80x20 and 120x20 (delivered with adaptors) Flat angles are variable (85 to 120 ) 033747 80x20 033667 120x20 3 / 6

3. RANGE 140x35. DLP Skirting trunking offers: - the distribution, the protection and the derivation of various cables in an electrical installation. - trunkings, finishing accessories (end cap, cover joint, interior angle, exterior angle, flat angle, derivation) - all the easy ways/advantages for the installation. - to comply with the norm NF EN 50085-2-1, safety and technical performance. - a flexibility with the installation and maintenance: 4. ACCESSORIES 140x35 4.1. Flat junction/flat angle ref. 033720. For flat junction : 3.1. Skirting trunking 2 compartments, 2 covers ref. 033700. Delivered in length of 2m. System with 2 zones: 1 zone for wiring accessories 1 zone for wiring (3 compartments) 2 independent covers (1 cover per zone) Wiring zone cover opens independently for ease of adding to the installation. Supplied with covers and clips Assembly of the body and covers by clips (disassembling with the assistance tool ex: screwdriver) Fixing by: - adhesive for glue gun ref 30949 - wall plugs for immediate fixing (without screw nor nail ref. 30899) - DLP rapid wall plug ref. 30897 (for 10mm min. plasterboard walls at least 20 mm away from a concrete surface. For fixing DLP plastic trunking in a single operation. - screw, nails Allows the flat junction to mini-trunkings up to 75x20 or dado trunking 80 or 120x20. For flat angle : Cutting with: - DLP cutting unit ref 30698, for cutting all plastic trunking (avoids vibration when cutting bases and covers) Dimensions. Allows the flat junction to mini-trunkings up to 75x20. Wiring capacity : To use with mini-trunking or dado trunking(delivered with adaptors) Skirting Trunking 140x35 Section in mm² /compartiment Number of conductors of 2.5mm²/ compartment Ref. 033700 150/345/510 6/15/22 4 / 6

4. ACCESSORIES 140x35 (continued) 4.2. Convection heater outlet réf.033714. 4. ACCESSORIES 140x35 (continued) 4.4. External angle ref. 033716. For end cap cap (right or felt) : End cap for junction with mini-trunking up to 40x25 For heating or air-conditionning : External angle allows: Variable external angles of 60 with 120. 4.5. Joint de couvercle réf. 033718. Can be used as cable outlet for convection heater or airconditionning with mini-trunking up to 40x25 - respect of the protection degree - improvement of aesthetics (covering of the cut) - left or right end cap. - the junction end to end of two covers - to improve aesthetics (covering of the cut) Assembly of the joint by fitment and screwing 4.6. Flat junction to floor duct ref. 032810. To use with mini-trunking (delivered with adaptors) 4.3. Internal angle ref. 033715. To tap-off to floor duct ref. 032800. Internal angle allows: Variable internal angles of 60 with 120. 5 / 6

5. TECHNICAL CHARACTERISTICS. Classification of DLP dado/skirting trunking systems EN 50085-2-1. 6.2 Resistance to impact for installation and application 2.0J 6.3 Minimum storage and transport temperature - 25 C 6.3 Minimum installation and application temperature - 5 C 6.3 Maximum application temperature + 60 C 6.4 Resistance to flame propagation Non-flame propagating 6.5 Electrical continuity characteristic With electrical continuity characteristic 6.6 Electrical insulating characteristic Without electrical insulating characteristic 6.7 Degrees of protection provided by enclosure IP40 6.9 The system access cover retention With a tool 6.101 The position when surface mounted Wall fixed Celling fixed 6.102 The functions provided Type 1 Rated current 500 V Protection against mechanical shocks IK 07 Compositions and functions of DLP Dado/Skirting trunking systems (1 system per line) EN 50085-2-1: DLP Dado/Skirting trunking Body/cover references Section (mm²) End cap 80x20 30069 350/500 33744 120x20 30089 350/1020 33774 140x35 33700 150/345/510 33714 6. MATERIAL CHARACTERISTICS. Trunking 80/120x20 and 140x35 in PVC white color RAL 9003 Accessories in PVC white color RAL 9003 6 / 6