Surface Roughness Tester TR110 Instruction Manual

Similar documents
Manual Surface Texture Meter PCE-RT 10

Instruction Manual TS

LEEB HARDNESS TESTER TH130/132/134

Recommendations for cot grinding

Chapter 9. Metrology of Surface Finish. Oxford University Press All rights reserved.

LEEB HARDNESS TESTER TH130/132/134

Top spin Nr /

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

VC835 DIGTAL MULTIMETER Operation Manual

INSTRUCTION MANUAL PCE-HT 550

INSTRUCTION MANUAL PCE-HT 500

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Photometer Maintenance Guide

Model R7900. Instruction Manual. Ultrasonic Thickness Gauge. reedinstruments. www. com

170 / 130 / 150 TH 132 TH 5100 (TH 130/150/170) TH 160 TH MHT

DIGITAL MULTIMETER AX-588B

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Precise Counting Scale GC. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGC

Non-contact Forehead IR Thermometer

Wind Transmitter First Class

Wireless Pressure Station with Backlight

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

170 / 130 / 150 TH 132 TH 5100 (TH 130/150/170) TH 160 TH MHT

Manifold Electronic Gauge. Model: KC-100B-1 Operation Manual

Wind Transmitter First Class / 141 / / 141 / 161

High Temperature InfraRed Thermometer with Laser Pointer

Head Office: Meieki, Nakamura-ku, Nagoya City , Japan TEL: +81(0) FAX: +81(0) Press Release

Instructions. Pocket Surf IV. Portable Surface Roughness Gages

Operating Manual MRL-101

CTS-27 Digital Gaussmeter OPERATION MANUAL. XIAMEN YUXIANG MAGNETIC MATERIAL IND CO., LTD. Jan 2005

Model EARTH RESISTANCE CLAMP USERS MANUAL EARTH RESISTANCE C L A M P : CAT II. 1mA 20A AL : ~ 600V

Preface. General Requirements for Safety. Precautions

ISH-R150 MANUAL ROCKWELL HARDNESS TESTER OPERATION MANUAL

Analog Technologies VC99. Multimeter FEATURES

HVS-1000DN. Digital Micro Vickers Hardness Tester. BMS Bulut Makina Sanayi Ve Ticaret Ltd. Şti.

WEATHER FORECAST MULTI-CHANNEL IN-OUT THERMOMETER WITH CABLE FREE SENSOR AND RADIO CONTROLLED CLOCK MAIN FEATURES: MAIN UNIT INTRODUCTION

User s Manual. hand-held laser distance meter

REV A.1 CMCP810PC SERIES RUNOUT KIT INSTRUCTION MANUAL STI VIBRATION MONITORING INC

Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight Ratio, Data Logging, USB Output, Single Type K Input, and Temperature Alarm


Ophthalmic Slit-lamp Microscope (SLM 1ER) Operation. Instruction

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

MANUAL. Electrostatic Field Meter EFM 235 / 255. System Prof. Dr.-Ing. Hans Kleinwächter

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Contents I. APPLICATIONS II. SPECIFICATIONS III. PRINCIPLES IV OPERATION V. MAINTENANCE

Precision Measuring Equipment and Industrial Supplies since 1924.

A510S Operation Manual

Wireless Rain Station

Laser Distance Finder Extech DT500

Bidirectional Ultrasonic Distance Measurement

Surface Finish Measurement Methods and Instrumentation

Quick Draw Electronics. Shooting Sports Timer II User Manual. Model TS1001

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

GFL-1000 User Manual Ground Fault Locator

WIRELESS 433MHZ WEATHER STATION

Module-5 Lecture-3 Stylus type surface measuring instruments. (Refer Slide Time: 00:16)

TPW899. Package Contents. Technical Details

Operating Instructions

USER MANUAL. Laser Distance Meter MODELS DT40M, DT60M, and DT100M

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

Mini Photo Printer User Manual

PARAGON BATH SHOWER DOOR/ BATH TUB SCREEN INSTALLATION INSTRUCTIONS. DR-584b

Engineering drawing. Semester I/II Mechanical Engineering Department Technical University of Gdańsk. Lecture 8

Micro-Ohmmeter Model UM200

CONTENT Warning...1 Ⅰ.Introduction...3 Ⅱ. Model...4 Ⅲ. Electrical Symbols...4 Ⅳ.Technical Specification Base Conditions and Working Conditions..

Laser Distance Finder Extech DT500

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Aeon CLR Series EDGE FREE CLR Fixed Frame Screen w/ StarBright CLR (Ceiling Light Rejecting ) Front Projection Material

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

PRODUCT BROCHURE PROFILER R. Tactile sensor for roughness measurement on Leitz CMMs

Model: &

Dawson DSM150. Digital Light Meter User s Manual

CONTENTS. Note: If using Alkaline Rechargeable battery place solar panel under light source for 6 hours with rechargeable battery in place to charge.

Keypad Quick Reference

Model: WS-7014CH-IT Instruction Manual DC: WIRELESS FORECAST STATION

ADAE portable X ray machine Operation manual

7. Operating instructions: EFL 300

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

LED Thin Frame Fixed Frame Screen User Guide

433 MHZ REMOTE THERMO

With the increased use of mobile & portable devices, the Ag301 & Ag311 wireless power modules offer a wide range of benefits: -

Stride / Stride Dual

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

grinding & polishing 39

SCREENING EFFICIENCY TESTER Model 271

Wireless Color Weather Station

Atomic Forecast Station with Moon Phase

InsuLogix T Portable One Channel Temperature Measurement System Manual

Fluke 125. Getting Started. Industrial ScopeMeter

Operating manual. TruTool N 500 (1A1) english

Standard Operating Procedure

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

Operator's manual TruTool PN 130 (1A1)

Ultra / Ultra Dual. Waterproof & Rechargeable Dog Training Collar. Note: Picture shown is Ultra Dual

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

FAG Detector II the mobile among data collectors. Technical Product Information

Ambient Light Rejecting Fixed Frame Screen. (3.9 width frame) User s Guide

Transcription:

Surface Roughness Tester TR110 Instruction Manual TIME Group Inc. Beijing TIME High Technology Ltd. Content 1 General Introduction...3 2. Work Principle...4 3. Standard Delivery...5 4. Name of each part...6 5. Operation...7 5.1 Preparation before operation...7 5.2 Switch on, Switch off and Backlight...9 5.3 Set up parameters...9 5.4 Measuring...11 5.5 Calibration...12 5.6 M/in Conversion...14 1

2 5.7 Switch off automatically...14 5.8 Indication of low battery...14 5.9 Battery recharge...15 6. Maintenance...15 7. Technical Parameters and Functions...16 7.1 Main Technical Parameters...16 7.2 Main Functions...18 7.3 Operating Environment...18 8. Terminology and Parameters for Surface Roughness...19 9. Recommended Sampling Length Table...21 10. Non-warranty Parts...22 1. General Introduction TIME Pocket-Sized Surface Roughness Tester TR110 is a new generation of Surface Roughness Tester Series, introduced to market by TIME Group Inc. in 2003. It features high accuracy, wide application, simple operation, portability and stable performance. The tester is widely used in measuring the surface roughness of various metals and non-metals. Its integrated structure of sensor and main body and hand-held design make it suitable to be used in production sites. Updated functions of TR110: TR110 s appearance, which tallies with current new design trend, makes it more amiable than previous product generation. More logical operation offers a comfortable use procedure to users. With a long-life Li-ion rechargeable battery, the tester can be worked for a long time with a short rechargeable time, and is workable during battery recharge. Circuit function is improved. Working voltage is debased. Accordingly, its work wastage and circuit noise are debased. Its pickup s driver setup, material and processing technics have been ameliorated. With a more precise assembly, the tester has gotten a more stable performance. 3

4 Some necessary instruction information such as testing indication, low battery indication etc has been added to the new designed LCD interface. A protective sheath for the sensor stylus offers an effective protect for the sensor stylus, so as to guarantee its precision. Backlight is adopted to assure the tester to be used in dark place. Smaller size and lighter weight. 2. Work Principle When the pickup was driven by a driver is making a linear uniform motion along the testing surface, the stylus which touches with the work surface moves up and down along the work surface perpendicularly. Its motion is converted into electric signals, which are amplified, filtered and transformed into digital signals through A/D. The signals are then processed by CPU into Ra and Rz values before being displayed on the screen. 3. Standard Delivery Standard sample plate 1 Main unit 1 Li-ion rechargeable Battery 1 5

6 4. Name of each part 1. Stylus mark 7 LCD 2. Switch of sensor stylus protective sheath 8 Start Key 3. Main body crust 9 Charging socket 4. Left Key 10 Reset Key 5. Middle Key 6. Right Key 11 Hole lid 12. Label 5. Operation 5.1 Preparation before operation The pickup stylus protective sheath should be closed, when the gauge is taken out of casing for the first time. Refer to Picture 1 Picture1 Closed pickup stylus protective sheath Pull the switch of pickup stylus protective sheath to the right and open the pickup stylus protective sheath. 7

8 The pickup stylus will show for measuring Refer to Picture 2 Picture2 Open pickup stylus protective sheath Show the location of stylus protective sheath (on or off) and the stylus status of being used or being protected. The key on the left means the pickup stylus protective sheath is closed and the stylus is protected. On the contrary the key on the right means the pickup stylus protective sheath is opened and the stylus can be used. 5.2Switch on, Switch off and Backlight Press the discretional Key to switch on. The screen will display as picture 3. After a d sound, the tester enters the measuring status and is ready to work with the display of measuring parameters and sampling length, which set at previous time.(refer to Picture 3) Picture 3 When the tester has been switched on, keep pressing the Right Key for 1.5 seconds, the Backlight will be turned on; if keep pressing the Right Key for 3.5 seconds, the tester will be turned off, and enter the status of low work wastage. 5.3 Set up parameters Before measuring the user should set up these parameters such as Ra, Rz and suitable sampling length (2.5mm, 0.8mm or 0.25mm) (refer to chapter 9). After switch on, press the Left Key gently and quickly to select the parameter Ra or Rz by turns. (Refer to Picture 4) Press the Middle Key gently and quickly to select the sampling length (0.25mm 0.8mm 2.5mm) by turns.(refer to Picture 5) 9

10 5.4 Measuring When the parameters are set up and the cut-off samples length is decided, it will come to measurement. Point the Stylus mark to the measured area stably and then press the Start Key on the top to start measurement. The stylus will move along the measured surface, and the screen will display as Picture 6. shows the stylus travel dynamically. The traverse length is 6mm. Pickup Stylus travels as Picture 7. When the icon is lighting, it means the pickup is coming to the start position and at this time it will be invalid to press the Star Key. After the icon disappeared with two d, d. sound, the measurement has being finished, and the screen will show as the picture8. Note: During the pickup s travel, do your best to make sure the tester is on 11

12 the measured surface stably so as to avoid its influence to the precision. Before the pickup return to its previous position, the tester will not make any response to further operation. New measurement is prohibited until the entire measurement is finished. When appears on the screen, that means a mistake. If the tester has been dying, you must press the Reset Key, and then you can use it again. (Refer to the picture9) 5.5 Calibration Before use, Calibration should be done with the standard sample plate.for example, there is a standard sample plate pointed to 3.27: Firstly, locate the tester onto the reticle area of the standard sample plate, and make the pickup s travel direction is vertical to the veins direction of the reticle (refer to picture 10). After that, press the start key to make measurement. The measuring value will be shown on the screen that is 3.21. And then it comes to the next step of calibration. When the tester is under non-measuring status, keep pressing the Left Key more than 2 seconds, the tester will enter the status of Calibration. (Refer to picture 11) Press the Left Key and Middle Key to adjust the displaying value to the value 3.27 (Refer to picture 12). Press the Start Key to exit the status of Calibration. After calibration, the calibrated measuring value Ra will show on the screen. (At the meantime, the new standard sample plate value Ra will be stored to the memory instead of the old one). 13

14 After the sensor returns to its original place, the tester can be used to make normal measurement. If the user has multi-reticle sample plate, he can choose suitable sample plate to calibrate the tester against his measuring range in common use. By this way, the tester s precision can be improved greatly. 5.6 M/in Conversion Keep pressing the Middle Key more than 2 seconds, the tester will enter the status of M/IN conversion. (Refer to Picture 13) 5.7 Switch off automatically The tester will switch off automatically if there is no operation in 90 seconds. 5.8 Indication of low battery When the battery symbol displays on the upper right of the screen, that means low battery. Recharging is needed. When are shown on the screen together with d,d.. sound, that means utmost low battery and prompt recharging should be done. (Refer to Picture14). 5.9 Battery recharge Plug the charger into the tester's recharge socket and have the tester recharged together with the battery symbol lighting (if no lighting, plug it again). 3 hours recharging-time is enough. The tester is workable during recharging. Recharge socket is on the right of tester. 6. Maintenance Protect the tester from collision, violent shock, heavy dust, dampness, oil stain and strong magnetic field etc. 15

16 Please switch off in time after each measurement to save the energy, and have the battery recharged promptly when necessary. The usual suitable recharging-time for the tester is 3 hours. Please pay attention to prevent the battery from being damaged by over-time recharge. The sensor is the precision part of the tester and particular care should be taken of it. After each use, put on the protective sheath gently so as to avoid violent shock to the sensor. Standard sample plate provided with the tester should be given special protection to avoid scratch that may make the calibration inaccurate. 7. Technical Parameters and Functions 7.1 Main Technical Parameters Parameters (µm): Ra, Rz Traverse Length (mm): 6 Sampling Length (mm): 0.25, 0.80 and 2.5 Evaluation Length (mm): 1.25, 4.0 and 5.0 Measuring Range (µm): Ra: 0.05--10.0 Rz: 0.1--50 Display error: ±15% Repeatability of Displayed Value: 12% Stylus: Diamond tip Radius: 10µm±1µm Diamond tip Angle: Stationary measuring force and its variations of the stylus: Stationary measuring force: 0.016N Variation of the measuring force: 800N/m Pressure of the skid-dependent of the sensor: 0.5N Power supply: 3.6V Li-ion battery Charger: DC 6V, with 3-hour recharging time. Overall Dimensions: 110 mm 70 mm 24 mm Weight: 160g 17

18 7.2 Main Functions Selectable measurement parameters: Ra, Rz Optional sampling length Calibration function Automatic testing of battery voltage and sound of alarm Battery recharging function, workable while recharging 7.3 Operating Environment Operating conditions Temperature: 0~40 Relative humidity: < 80% No vibration; no corrosive media Conditions for storing Temperature: - 25 ~ 60 Relative humidity: < 90% Ventilation: Grade 3 8. Terminology and Parameters for Surface Roughness Surface Roughness is the microcosmic geometric form on the work-piece surface composed by peak and valley with small interspaces. Sampling Length is the benchmark s length used to be distinguished its surface roughness. Evaluation Length is the necessary length for evaluating the roughness profile. It may include one or more sampling lengths. Ra: Arithmetical Mean Deviation of the Profile is arithmetic mean value of the deviation of the profile within sampling length. 19

20 Rz: The maximum Height of Irregularities is the distance between maximum depth of the profile peaks and maximum depth of the profile valley within the sampling length. 9. Recommended Sampling Length Table Ra (µm) Rz (µm) Sampling Length (mm) 40 80 160 320 20 40 10 20 5 10 2.5 5 1.25 2.5 0.63 1.25 0.32 0.63 0.25 0.32 0.20 0.25 0.16 0.20 80 160 40 80 20 40 10 20 6.3 10 3.2 6.3 1.6 3.2 1.25 1.6 1.0 1.25 0.8 1.0 8 2.5 0.8 0.25 0.125 0.16 0.1 0.125 0.08 0.1 0.63 0.8 0.5 0.63 0.4 0.5 21

22 0.063 0.08 0.05 0.063 0.04 0.05 0.032 0.04 0.025 0.032 0.02 0.025 0.016 0.02 0.0125 0.016 0.01 0.0125 0.008 0.01 0.0063 0.008 0.063 0.32 0.4 0.25 0.32 0.2 0.25 0.16 0.2 0.125 0.16 0.1 0.125 0.08 0.1 0.063 0.08 0.05 0.062 0.04 0.05 0.032 0.004 0.032 0.08 10. Non-warranty Parts Sheath of TR100, Pickup, Battery, Charger, Communication cable