Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

Similar documents
Agilent U1271A/U1272A Handheld Digital Multimeter. Quick Start Guide

Agilent U1231A/U1232A/U1233A Handheld Multimeter. Quick Start Guide

Keysight U1231A/ U1232A/U1233A Handheld Multimeter. Quick Start Guide

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

Keysight U1461A Insulation Multimeter/ U1453A Insulation Tester

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

Keysight U1241C/ U1242C Handheld Digital Multimeter. Quick Start Guide

Agilent U1273A/U1273AX Handheld Digital Multimeter

Keysight U1273A/U1273AX Handheld Digital Multimeter

Keysight U1273A/U1273AX Handheld Digital Multimeter

Agilent U1211A, U1212A, and U1213A Clamp Meter. Quick Start Guide U1211A U1212A U1213A

Agilent U1231A, U1232A, and U1233A Handheld Digital Multimeter

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Agilent U1251A and U1252A Handheld Digital Multimeter

Agilent U1190A Series Handheld Clamp Meters

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Agilent U1271A/U1272A Handheld Digital Multimeter

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

DVM1190 DIGITAL MULTIMETER

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

MS2030 CAT III 600 V A V AUTO RS232

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Dawson DDM190. Digital Multimeter User s Manual

Keysight U1231A, U1232A, and U1233A Handheld Digital Multimeter

Agilent U1253B True RMS OLED Multimeter

USER'S MANUAL DMR-6700

Electrical Multimeter

Electrical Multimeter

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

Agilent U1450A/U1460A Insulation Resistance Testers

OPERATING INSTRUCTION

Keysight U1253B True RMS OLED Multimeter

Keysight U1253B True RMS OLED Multimeter

Keysight U1241B and U1242B Handheld Digital Multimeters

79/26 Series III Multimeter

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

400Amp True RMS AC/DC Clamp Meter Model EX613

1.General instructions Specifications Description...7

Autoranging Multimeter Extech EX503

Agilent U1241A and U1242A Handheld Digital Multimeters

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Pocket Size Digital Multimeter with USB Model: A & A

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Agilent U1251B and U1252B Handheld Digital Multimeter

Agilent U1251A and U1252A Handheld Digital Multimeter

Agilent U1241B and U1242B Handheld Digital Multimeters

Agilent U1731C, U1732C, and U1733C Handheld LCR Meter

Not for Reproduction

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

DM-45 Digital Multimeter

OPERATOR S INSTRUCTION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Agilent U1230 Series Handheld Digital Multimeter (DMM)

AMM-1022 Digital Multimeter USER`S MANUAL

200Amp AC Clamp Meter + NCV Model MA250

AC/DC CLAMP METER USER S MANUAL

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Analog Technologies. Multimeter 115C and 117C

400Amp True RMS AC Clamp Meter + NCV

The Meter Structure The Figure 2-1 shows the Meter structure.

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

User Manual Digital Multimeter

KMD-S04 Multímetro de bolsillo

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Agilent U1253A True RMS OLED Multimeter

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

AX-C Introduction. 2. Safety Information

Digital MultiMeter - Make your job efficiency User Instruction Manual

CONTENTS MS2033A. 1.Introduction Safety Information...01

Digital Multimeter User Manual

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

R/C SMD Tweezers Multimeter Model RC200

U1401A Handheld Multi-Function Calibrator/Meter

NOTE: Fully read and understand this manual before using this Digital Multimeter.

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Model : OPERATING MANUAL Table of Contents (1)

Compact MultiMeters + Voltage Detector

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

VC835 DIGTAL MULTIMETER Operation Manual

Keysight Technologies U1270 Series Handheld Digital Multimeters. Data Sheet

Keysight U1211A, U1212A, and U1213A Clamp Meters

Model UT10A: OPERATING MANUAL Table of Contents (1)

Sales: Technical: Fax:

User Manual Digital Multimeter. model no.: MSR-U1000

Model 77 Series IV. Digital Multimeter. Users Manual

Transcription:

Agilent U1273A/U1273AX Handheld Digital Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads One pair of 4 mm test probes One K-type thermocouple lead kit Four 1.5 V AAA alkaline batteries (for U1273A) or lithium batteries (for U1273AX) Printed copies of the Certificate of Calibration (CoC) and the U1273A/U1273AX Quick Start Guide (this manual) If any item is missing or damaged, keep the shipping materials and contact the nearest Agilent Sales Office. NOTE The descriptions and instructions in this guide apply to the U1273A/U1273AX handheld digital multimeter. All related documents and software are available for download at www.agilent.com/find/hhtechlib. Agilent Technologies

Install the Batteries Install the Batteries Your multimeter is powered by four 1.5 V AAA batteries (included with the shipment). 1 Turn the rotary switch to OFF and remove the test leads from the terminals. 2 Lift the tilt stand and loosen the screws with a suitable Phillips screwdriver. 3 Remove the battery cover and observe the polarity markings. 4 Insert the batteries and replace the battery cover and screws. Turn On the Multimeter To power ON your multimeter, turn the rotary switch from the OFF position to any other position. NOTE Your multimeter is capable of remote data logging. To use this feature, you will need an IR-USB cable (U1173A, purchased separately) and the Agilent GUI Data Logger Software (downloadable from www.agilent.com/find/hhtechlib). Auto Dim By default, the multimeter s Auto Dim function is enabled. The multimeter s backlight will dim automatically after 90 seconds of inactivity. Press any button to cancel this effect and reset the Auto Dim timer. You may change how the multimeter s backlight behavior through the Setup menu. Refer to the User s Guide for further instructions. 2 U1273A/U1273AX Quick Start Guide

The Multimeter at a Glance The Multimeter at a Glance Display screen Keypad Rotary switch Input terminals Test lead/probe holders IR communication port Battery cover (Lift tilt stand for access) Tilt stand U1273A/U1273AX Quick Start Guide 3

Understanding the Rotary Switch Understanding the Rotary Switch NOTE Press to switch between the primary and shifted functions shown on the rotary switch. Legend ZLOW Description Z LOW (low input impedance) AC/DC V for eliminating ghost voltages Off Smart Auto AC V AC V with Low Pass Filter AC mv AC mv with Low Pass Filter DC V AC V or AC+DC V DC mv AC mv or AC+DC mv Resistance Continuity or Smart Ω (offset compensation) Diode Auto-diode Capacitance Temperature DC ma (or A) AC ma (or A) or AC+DC ma (or A) DC μa AC μa or AC+DC μa 4 U1273A/U1273AX Quick Start Guide

Understanding the Keypad Understanding the Keypad Legend Null Scale MaxMin Peak Trig Hold Auto Dual Exit Setup Hz % ms Log Range Auto Key response when pressed for: Less than 1 second More than 1 second Sets the Null/Relative mode. Starts the MaxMin recording. Freezes the present reading in the display. Switches between available dual-combination displays. Increases the OLED brightness incrementally when LOW, MEDIUM, or HIGH setting is selected. Switches between frequency, pulse width, and duty cycle measurements. Sets a manual range and disables autoranging. Switches between the primary and shifted functions. Sets the Scale mode for the specified ratio and unit display. Starts and stops the Peak recording. Automatically freezes the present reading once the reading is stable. Exits the Hold, Null, MaxMin, Peak, frequency test, and dual display modes. Enters and exits the multimeter s Setup menu. Starts and stops the Data Logging. Enables auto-ranging. Enters and exits the Log Review menu. U1273A/U1273AX Quick Start Guide 5

Understanding the Input Terminals Understanding the Input Terminals WARNING Ensure that the terminal connections are correct for that particular measurement function before starting any measurement. To avoid damage to the device, do not exceed the input limit. Rotary position Input terminals Overload protection 1000 Vrms ZLOW Smart 1000 Vrms for short circuit <0.3 A Auto 11 A/1000 V fast-acting fuse or 440 ma/1000 V fast-acting fuse 6 U1273A/U1273AX Quick Start Guide

Performing Measurements and Tests Performing Measurements and Tests Voltage measurements The figure below highlights the primary functions allowing voltage measurements in your multimeter. Set up your multimeter as shown in the figure below to perform voltage measurements. 4 3 DC 2 1 U1273A/U1273AX Quick Start Guide 7

Performing Measurements and Tests LPF measurements: Passing the measured signal through a LPF help blocks unwanted voltages such as electronic noise. Use the LPF function to improve measurement on composite sine waves that are typically generated by inverters and variable frequency motor drives. Z LOW measurements: Press while performing ac voltage measurements to pass the measured signal through a low pass filter. Rotate the rotary switch s position to ZLOW to enable low impedance measurements. Use the Z LOW (low input impedance) function to remove ghost or induced voltages from your measurement. Z LOW can remove ghost voltages from your measurements by dissipating the coupling voltage. Use Z LOW to reduce the possibility of false readings in areas where the presence of ghost voltages are suspected. 8 U1273A/U1273AX Quick Start Guide

Performing Measurements and Tests Resistance measurements Set up your multimeter as shown in the figure below to perform resistance measurements. 4 3 2 Smart 1 Smart Ω measurements: While performing resistance measurements, press until BiAS is shown on the secondary display to enable the Smart Ω function. Use the Smart Ω (offset compensation) function to measure resistors affected by dc offset or leakage current. Smart Ω removes unexpected dc voltages within the instrument, at the input, or at the circuit being measured, which Dual will add error to resistance measurements. Press Exit to switch between the bias voltage (BiAS) display or leakage current (LEAk) display, calculated based on the bias voltage and corrected resistance value, on the secondary display. U1273A/U1273AX Quick Start Guide 9

Performing Measurements and Tests Continuity tests Dual Exit Set up your multimeter as shown in the figure below to perform continuity tests. Press to switch to the continuity test function ( is shown on the display). The beeper will sound as a continuity indication. Press to switch between normal open ( ) and normal close ( ) contacts. Normal open: Circuit is normally open, the beeper will sound when a short is detected. Normal close: Circuit is normally closed, the beeper will sound when an open is detected. 4 5 OFF (open) 3 ON (closed) 2 Smart 1 NOTE The continuity function detects intermittent shorts and opens lasting as short as 1 ms. A brief short or open causes the multimeter to emit a short beep. 10 U1273A/U1273AX Quick Start Guide

Performing Measurements and Tests Diode tests Set up your multimeter as shown in the figure below to perform diode tests. 4 3 2 Auto 1 Auto-diode tests: Press function. to use the auto diode The Auto-diode function tests both the forward bias and reverse bias directions of your diode simultaneously. The forward bias voltage is shown on the primary display and the reverse bias voltage is shown on the secondary display. GOOD is shown briefly on the secondary display along with a brief beep if the diode is found to be in good condition. If the diode is out of the thresholds, NGOOD is shown instead. U1273A/U1273AX Quick Start Guide 11

Performing Measurements and Tests Capacitance measurements Set up your multimeter as shown in the figure below to perform capacitance measurements. 4 3 2 1 NOTE is shown on the bottom left of the display when the capacitor is charging, and is shown when the capacitor is discharging. 12 U1273A/U1273AX Quick Start Guide

Performing Measurements and Tests WARNING Temperature measurements Set up your multimeter as shown in the figure below to perform temperature measurements. Press to switch to the temperature measurement function. Do not connect the thermocouple to electrically live circuits. Doing so will potentially cause fire or electric shock. 5 4 3 2 Heat source 1 K-type thermocouple NOTE The multimeter uses a type-k (default setting) temperature probe for measuring temperature. U1273A/U1273AX Quick Start Guide 13

Performing Measurements and Tests WARNING Current measurements Set up your multimeter as shown in the figure below to perform current measurements. Press to switch between ac, dc, ac+dc, or % scale current measurements. Always use the proper function, range, and terminals for current measurements. Set the positive input terminal to the terminal for currents below 440 ma, and the terminal for currents above 440 ma. 4 3 AC LOAD 2 1 NOTE For better accuracy when measuring low currents (up to μa), turn the rotary switch to the position. 14 U1273A/U1273AX Quick Start Guide

Check the Fuse Check the Fuse Follow the instructions below for a quick check on the fuses (Fuse 1 and Fuse 2) of your multimeter. Fuse Part Displayed readings Fuse rating number Fuse healthy Replace fuse 1 2110-1400 440 ma/1000 V 102 Ω OL 2 2110-1402 11 A/1000 V 0.05 Ω OL To check Fuse 1 To check Fuse 2 Smart Smart U1273A/U1273AX Quick Start Guide 15

Check the Fuse NOTE To check Fuse 1: Ensure that the probe tip is touching the top half metal contact inside the µa ma terminal. To check Fuse 2: Ensure that the probe tip is touching the left half metal contact inside the A terminal. The multimeter will sound an input warning alert if the probe tip is in contact with any other sides of the µa ma or A terminal other than the sides specified in the instructions above. 16 U1273A/U1273AX Quick Start Guide

Contacting Agilent To obtain service, warranty, or technical assistance, contact us at the following phone numbers: United States Call Center: 800-829-4444 Canada Call Center: 877-894-4414 China Call Center: 800-810-0189 Europe Call Center: 31-20-547-2111 Japan Call Center: (81) 426-56-7832 For other countries, contact your country s Agilent support organization. A list of contact information for other countries is available on the Agilent Web site: www.agilent.com/find/assist Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAU- TION notice until the indicated conditions are fully understood and met. Safety and EMC Information This meter is safety-certified in compliance with EN/IEC 61010-1:2001, ANSI/UL 61010-1:2004, and CAN/CSA-C22.2 No. 61010-1-04 for CAT III 1000 V/CAT IV 600 V pollution degree 2 environment. EMC is designed in compliance with IEC 61326-1:2005/EN 61326-1:2006. Use with standard or compatible test probes. Safety Symbols Earth (ground) terminal WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. CAT III 1000 V CAT IV 600 V Equipment protected throughout by double insulation or reinforced insulation Caution, risk of electric shock Caution, risk of danger (refer to the instrument manual for specific Warning or Caution information) Category III 1000 V overvoltage protection Category IV 600 V overvoltage protection For further safety information details, refer to the Agilent U1273A/U1273AX Handheld Digital Multimeter User s Guide.

Printed in Malaysia First Edition, August 5, 2012 Agilent Technologies, Inc., 2012 U1273-90004 Agilent Technologies