Agilent U1271A/U1272A Handheld Digital Multimeter. Quick Start Guide

Similar documents
Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

Agilent U1231A/U1232A/U1233A Handheld Multimeter. Quick Start Guide

Keysight U1231A/ U1232A/U1233A Handheld Multimeter. Quick Start Guide

Keysight U1461A Insulation Multimeter/ U1453A Insulation Tester

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

Keysight U1241C/ U1242C Handheld Digital Multimeter. Quick Start Guide

Agilent U1273A/U1273AX Handheld Digital Multimeter

Agilent U1231A, U1232A, and U1233A Handheld Digital Multimeter

Keysight U1273A/U1273AX Handheld Digital Multimeter

Keysight U1273A/U1273AX Handheld Digital Multimeter

Agilent U1211A, U1212A, and U1213A Clamp Meter. Quick Start Guide U1211A U1212A U1213A

Agilent U1251A and U1252A Handheld Digital Multimeter

Keysight U1231A, U1232A, and U1233A Handheld Digital Multimeter

Agilent U1271A/U1272A Handheld Digital Multimeter

Agilent U1190A Series Handheld Clamp Meters

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Agilent U1251A and U1252A Handheld Digital Multimeter

USER'S MANUAL DMR-6700

Agilent U1253B True RMS OLED Multimeter

Agilent U1251B and U1252B Handheld Digital Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Not for Reproduction

MS2030 CAT III 600 V A V AUTO RS232

Agilent U1450A/U1460A Insulation Resistance Testers

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

DVM1190 DIGITAL MULTIMETER

User s Guide. 400A AC/DC Clamp Meter. Model MA220

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Keysight U1253B True RMS OLED Multimeter

Dawson DDM190. Digital Multimeter User s Manual

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Agilent U1230 Series Handheld Digital Multimeter (DMM)

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Agilent U1241A and U1242A Handheld Digital Multimeters

Keysight U1253B True RMS OLED Multimeter

400Amp True RMS AC/DC Clamp Meter Model EX613

OPERATOR S INSTRUCTION MANUAL

Agilent U1270 Series Handheld Digital Multimeters

Autoranging Multimeter Extech EX503

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Keysight U1241B and U1242B Handheld Digital Multimeters

OPERATING INSTRUCTION

Agilent U1731C, U1732C, and U1733C Handheld LCR Meter

Digital Multimeter User Manual

79/26 Series III Multimeter

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

AC/DC CLAMP METER USER S MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

AMM-1022 Digital Multimeter USER`S MANUAL

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Pocket Size Digital Multimeter with USB Model: A & A

Keysight Technologies U1230 Series Handheld Digital Multimeters (DMMs) Data Sheet

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

1.General instructions Specifications Description...7

Keysight Technologies U1270 Series Handheld Digital Multimeters. Data Sheet

Agilent U1241B and U1242B Handheld Digital Multimeters

DIGIT & POINTER MULTIMETER

Agilent U1253A True RMS OLED Multimeter

200Amp AC Clamp Meter + NCV Model MA250

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Compact MultiMeters + Voltage Detector

VC835 DIGTAL MULTIMETER Operation Manual

User Manual Digital Multimeter

Keysight U1211A, U1212A, and U1213A Clamp Meters

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Electrical Multimeter

Keysight Technologies U1270 Series Handheld Digital Multimeters. Data Sheet

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

U1401A Handheld Multi-Function Calibrator/Meter

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

DIGITAL HiTESTER. Instruction Manual

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

MANUAL DE INSTRUÇÕES DO MULTÍMETRO DIGITAL MODELO MD-6

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

The Meter Structure The Figure 2-1 shows the Meter structure.

DM-45 Digital Multimeter

DIGITAL MULTIMETER AUTORANGING

AX-C Introduction. 2. Safety Information

Keysight Technologies U1280 Series Handheld Digital Multimeters

DIGITAL MULTIMETER INSTRUCTION MANUAL

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Keysight U1401B Handheld Multi-Function Calibrator/Meter

Analog Technologies. Multimeter 115C and 117C

True-RMS Digital Multimeter User Manual

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

DDM350 Pen-Type Digital Multimeter User s Manual

Transcription:

Agilent U1271A/U1272A Handheld Digital Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads One pair of 4 mm test probes One K-type thermocouple lead kit Four 1.5 V AAA alkaline batteries Printed copy of the U1271A/U1272A Quick Start Guide Printed copy of the Certificate of Calibration If any item is missing or damaged, keep the shipping materials and contact the nearest Agilent Sales Office. NOTE The descriptions and instructions in this guide apply to the U1271A and U1272A Handheld Digital Multimeters. The model U1272A appears in all illustrations. All related documents and software are available for download at www.agilent.com/find/hhtechlib. Agilent Technologies

Differences between the U1271A and U1272A Differences between the U1271A and U1272A The U1272A model offers these additional functions: Z LOW (low input impedance) measurements Smart Ω measurements Auto-diode tests AC+DC voltage and current measurements J-type thermocouple temperature measurements 30 Ω and 300 MΩ ranges for resistance measurements dbm and dbv measurements with selectable impedance Data logging up to 10,000 memories The U1271A model has one differing function: Qik-V tests Install the Batteries Your multimeter is powered by four 1.5 V AAA alkaline batteries (included with the shipment). 1 Turn the rotary switch to OFF and remove the test leads from the terminals. 2 Lift the tilt stand and loosen the screws with a suitable Phillips screwdriver. 3 Remove the battery cover and observe the polarity markings. 4 Insert the batteries and replace the battery cover and screws. Turn On the Multimeter To power ON your multimeter, turn the rotary switch to any other position. NOTE Your multimeter is capable of remote data logging. To use this feature, you will need an IR-USB cable (U1173A, purchased separately) and the Agilent GUI Data Logger Software (downloadable from www.agilent.com/find/hhtechlib). 2 U1271A/U1272A Quick Start Guide

The Multimeter at a Glance The Multimeter at a Glance Display screen Keypad Rotary switch Input terminals Test lead/probe holders IR communication port Battery access cover Tilt stand U1271A/U1272A Quick Start Guide 3

Understanding the Rotary Switch Understanding the Rotary Switch U1271A U1272A NOTE to switch between the shifted and regular func- Press tions. Esc Shift View Legend Description AC V with Low Pass Filter AC mv with Low Pass Filter DC, (AC, or AC+DC V, U1272A only) DC, (AC, or AC+DC mv, U1272A only) Smart Auto Resistance/Continuity/(Smart Ω, U1272A only) Diode/(Auto-diode, U1272A only) Capacitance/Temperature AC, DC, or (AC+DC ma and A, U1272A only) AC, DC, or (AC+DC μa, U1272A only) Qik-V ZLOW AC/DC V check for signal identification (U1271A only) Z LOW (low input impedance) AC/DC V for checking ghost voltages (U1272A only) 4 U1271A/U1272A Quick Start Guide

Understanding the Keypad Understanding the Keypad Legend Null Scale MaxMin Peak Trig Hold Auto Dual Exit Setup Hz % ms Log Key response when pressed for: Less than 1 second More than 1 second Sets the Null/Relative mode. Starts and stops the MaxMin recording. Freezes the present reading in the display. Switches between available dual-combination displays. Turns the backlight on/off. Switches between frequency, pulse width, and duty cycle measurements. Sets the Scale mode for the specified ratio and unit display. Starts and stops the Peak recording. Automatically freezes the present reading once the reading is stable. Exits the Hold, Null, MaxMin, Peak, frequency test, and dual display modes. Enters/Exits the multimeter s setup menu. Starts and stops the Data Logging. Range Auto Sets a manual range. Enables autoranging. Esc Shift View Switches between the regular and shifted (icons printed in orange) functions. Enters the Log Review menu. U1271A/U1272A Quick Start Guide 5

Understanding the Input Terminals Understanding the Input Terminals WARNING Ensure that the terminal connections are correct for that particular measurement function before starting any measurement. To avoid damage to the device, do not exceed the input limit. Rotary position Input terminals Overload protection Qik-V 1000 Vrms ZLOW Smart 1000 Vrms for short circuit <0.3 A Auto 11 A/1000 V, 30 ka fast-acting fuse 440 ma/1000 V, 30 ka fast-acting fuse 6 U1271A/U1272A Quick Start Guide

Voltage measurements The figure below highlights the primary functions allowing voltage measurements in your multimeter. U1271A U1272A Set up your multimeter as shown in the figure below to perform voltage measurements. DC U1271A/U1272A Quick Start Guide 7

LPF measurements: Press while performing ac voltage measurements to pass the measured signal through a low pass filter. Esc Shift View Passing the measured signal through a LPF help blocks unwanted voltages such as electronic noise. Use the LPF function to improve measurement on composite sine waves that are typically generated by inverters and variable frequency motor drives. Z LOW measurements (U1272A only): Rotate the rotary switch s position to ZLOW to enable low impedance measurements. Use the Z LOW (low input impedance) function to detect ghost or induced voltages. Ghost voltages can be caused by capacitive coupling between energized wiring and adjacent unused wiring. Qik-V test (U1271A only): Rotate the rotary switch s position to Qik-V to enable the Qik-V function. Use the Qik-V function to quickly identify the measured signal type. Use this function as a reference to determine if the measured signal is an AC or DC signal, then select the appropriate voltage measurement function by turning the rotary switch to an appropriate position (AC or DC). 8 U1271A/U1272A Quick Start Guide

Resistance measurements Set up your multimeter as shown in the figure below to perform resistance measurements. Smart Smart Ω measurements (U1272A only): While performing resistance measurements, press until is shown on the display to enable the Smart Ω function. Esc Shift View Use the Smart Ω function to measure resistors affected by dc offset or leakage current. If dc offset or bias voltages are detected on the resistor-under-measure, the offset or bias dc voltage value will be shown on the secondary display. If the dc voltage on the resistor is over +1.25 V, is shown on the secondary display. U1271A/U1272A Quick Start Guide 9

Continuity tests Set up your multimeter as shown in the figure below to perform continuity tests. Press to switch to the continuity test function ( is shown on the display). You can set the beeper to sound and the backlight to flash as a continuity indication whether the circuit-under-test is less than (short) or more than or equal to (open) the threshold resistance. Dual Press Exit to switch between short ( ) and open ( ) states for checking NO (normal open) and NC (normal close) contacts. Esc Shift View OFF (open) ON (closed) Smart NOTE The continuity function detects intermittent shorts and opens lasting as short as 1 ms. A brief short or open causes the multimeter to emit a short beep and flash. 10 U1271A/U1272A Quick Start Guide

Diode tests Set up your multimeter as shown in the figure below to perform diode tests. Auto Auto-diode tests (U1272A only): Press until is shown on the display to use the auto diode function. Esc Shift View The Auto-diode function tests both the forward bias and reverse bias directions of your diode simultaneously. The forward bias voltage is shown on the primary display and the reverse bias voltage is shown on the secondary display. will be indicated briefly on the secondary display along with a brief beep if the diode is found to be in good condition. is shown if the diode is out of the thresholds. U1271A/U1272A Quick Start Guide 11

Capacitance measurements Set up your multimeter as shown in the figure below to perform capacitance measurements. NOTE is shown on the bottom left of the display when the capacitor is charging, and is shown when the capacitor is discharging. 12 U1271A/U1272A Quick Start Guide

WARNING Temperature measurements Set up your multimeter as shown in the figure below to perform temperature measurements. Do not connect the thermocouple to electrically live circuits. Doing so will potentially cause fire or electric shock. NOTE The multimeter uses a type-k (default setting) temperature probe for measuring temperature. U1271A/U1272A Quick Start Guide 13

WARNING Current measurements Set up your multimeter as shown in the figure below to perform current measurements. Press to switch between ac, dc, ac+dc, or % scale current measurements. Always use the proper function, range, and terminals for current measurements. Set the positive input terminal to the terminal for currents below 440 ma, and the terminal for currents above 440 ma. Esc Shift View LOAD AC 14 U1271A/U1272A Quick Start Guide

Contacting Agilent To obtain service, warranty or technical assistance, contact us at the following phone numbers: United States Call Center: 800-829-4444 Canada Call Center: 877-894-4414 China Call Center: 800-810-0189 Europe Call Center: 31-20-547-2111 Japan Call Center: (81) 426-56-7832 For other countries, contact your country s Agilent support organization. A list of contact information for other countries is available on the Agilent Web site: www.agilent.com/find/assist Safety Notices CAUTION WARNING A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAU- TION notice until the indicated conditions are fully understood and met. A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. Safety Information This meter is safety-certified in compliance with EN/IEC 61010-1:2001, ANSI/UL 61010-1:2004, and CAN/CSA-C22.2 No. 61010-1-04. Use with standard or compatible test probes. Safety Symbols CAT III 1000 V CAT IV 600 V Earth (ground) terminal Caution, risk of electric shock Caution, risk of danger (refer to the instrument manual for specific Warning or Caution information) Category III 1000 V overvoltage protection Category IV 600 V overvoltage protection For further safety information details, refer to the Agilent U1271A/U1272A Handheld Digital Multimeter User s Guide.

Printed in Malaysia Third Edition, June 11, 2012 Agilent Technologies, Inc., 2010 2012 U1271-90000 Agilent Technologies