DIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS

Similar documents
DIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

INSTRUCTION MANUAL DIGITAL MULTIMETER

Digital Multimeter with Backlight

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

AUTO RANGING DIGITAL MULTIMETER

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

M-1000D DIGITAL MULTIMETER

AMM-1022 Digital Multimeter USER`S MANUAL

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

770E DIGITAL MULTIMETER OPERATOR S MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL

DIGIT & POINTER MULTIMETER

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Model DIGITAL MULTIMETER

Model : OPERATING MANUAL

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

DMM8900 SERIES USERS MANUAL

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

ProfiScale MULTI Multimeter

USER'S MANUAL DMR-6700

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Accuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

AC/DC CLAMP METER USER S MANUAL

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Sales: Technical: Fax:

R/C SMD Tweezers Multimeter Model RC200

DVM1190 DIGITAL MULTIMETER

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

VC835 DIGTAL MULTIMETER Operation Manual

KMD-S04 Multímetro de bolsillo

Autoranging Multimeter Extech EX503

USER'S MANUAL DMR-4300

User Manual Digital Multimeter

METRAVI. Table of Contents

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Pocket Size Digital Multimeter Models: and

Model UT39A/B/C: OPERATING MANUAL

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Handheld Digital Multimeter PRO-50A

Analog Technologies VC99. Multimeter FEATURES

DIGITAL MULTIMETER AUTORANGING

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Model : OPERATING MANUAL Table of Contents (1)

3B SCIENTIFIC PHYSICS

UT207A/208A/209A Operating Manual. Table of Contents

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Digital Clamp Meter Model: &

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

400Amp True RMS AC/DC Clamp Meter Model EX613

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

OPERATING INSTRUCTION

Multifunction Digital

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

Model UT10A: OPERATING MANUAL Table of Contents (1)

User Manual Digital Multimeter. model no.: MSR-U1000

BENCH METER Model>9803. Wavecom Instruments

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

True RMS Digital Multimeter Model:

User Guide. Digital AC/DC Clamp Meter Model 38394

MODEL: D03128 CLAMP METER

User s Guide. Digital AC/DC Clamp Meter Model 38394

DIGITAL MULTIMETER AX-588B

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

MULTIMETRE DIGITAL 3 3/4 AVEC ECHELLE AUTOMATIQUE & EXTINCTION AUTOMATIQUE MANUEL D UTILISATION

DIGITAL MULTIMETER

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

AC Clamp Meter + Phase Rotation Tester

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Pen-type DIGITAL MULTITESTER

270 manual.qxd 5/9/2005 3:04 PM Page 1. Digital Clamp-on Meter Instruction Manual

ATK Clamp Meter

DIGITAL MULTIMETER OPERATOR S MANUAL

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Digital Clamp Meter (TRMS) Model : 2727

Not for Reproduction

Compact MultiMeters + Voltage Detector

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

MS2030 CAT III 600 V A V AUTO RS232

Digital Clamp Meter. User Manual

Digital Multimeter AX-572. Instruction manual

Mini Clamp Meter Model:

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Transcription:

DIGITAL MULTIMETER MODEL CDM-50 Part No.4500065 OPERATING INSTRUCTIONS 0607

DATA HOLD FUNCTION When this button is pressed, the last reading to be taken will be held on the display, and D-H will appear alongside it, until either the button is pressed again, or the function switch is used. MAINTENANCE Battery and/or fuse replacement should only be done after the test leads have been disconnected, and power is OFF. BATTERY AND FUSE REPLACEMENT Note the condition of the 9-volt battery using the procedure described above. If the battery needs to be replaced, unscrew the three screws and remove the back cover. Replace the spent battery with one of the same type (NEDA. 1604, 6F22 or equiv). The same procedure is used to replace the fuses. Ensure the replacement is of the same size and value as the original. 0.3A/250V or 10A/250V DC, fast blow type. REPLACEMENT PARTS 1. Test Leads (pair) Part No. CH5001 2. HoIster (Size AA) Part No. CH5004 3. Fuse (0.3A/250V) Part No. CH5002 Fuse (10A/250V) Part No. CH5003 CE STANDARDS This unit complies with 73/23/EEC, 89/336/EEC. PARTS & SERVICE CONTACTS For Spare Parts and Service, please contact your nearest dealer, or CLARKE International, on one of the following numbers. When disposing of this product, do not dispose of with general waste. It must be disposed of according to the laws governing Waste Electrical and Electronic equipment, at a recognised disposal facility. CMD50 - Page2 PARTS & SERVICE TEL: 020 8988 7400 PARTS & SERVICE FAX: 020 8558 3622 or e-mail as follows: PARTS: Parts@clarkeinternational.com SERVICE: Service@clarkeinternational.com CMD50 - Page11

Continuity/Diode Measurement 1. Connect the BLACk?test lead to the COM jack and the RED test lead to the V/Ω/F jack. 2. Set the FUNCTION switch to the Position and push the Button to select continuity or diode test mode. 3. In continuity testing, if the resistance is less than 20Ω, the built in buzzer will sound. 4. If testing diodes, connect the test leads across the diode under test, (red to the anode). Display shows the approx forward voltage of this diode. Transistor hfe Test 1. Set the FUNCTION switch to the hfe range. 2. Determine whether the transistor is NPN or PNP and locate the Emitter, Base and Collector leads. Insert the leads into the proper holes in the socket on the front panel. 3. Display will read approx. hfe value at the test condition/base Current l0µa VCE 3.2V Measuring Range Control Button AC/DC voltage AC/DC current ranges (µa and ma only), Resistance and Frequency, can be set manually using this feature as follows. 1. Switching power ON, or changing FUNCTION, will set the Measuring Range to automatic mode. 2. To select Manual, press range button (1) once, briefly. The letters R-H will appear on the LED. By pressing range button (1) again, briefly, (less than 1 sec), the range will change as seen by the decimal point on the scale, moving to indicate xl00 xl000 etc. Pressing the same button for approx 3 seconds, will return to auto mode. CMD50 - Page10 Thank you for purchasing this Clarke Multi-Range Digital Multimeter. This instrument is a compact, rugged, battery operated hand held, digital multimeter. It is designed to measure AC and DC voltage, AC and DC current, Resistance, Diode, Capacitance, for testing Transistors, and has an Audible Continuity function. The display is a 3¾ digit, 3260 count LCD, and a linear bargraph. The dual-speed A-D converter ensures a high speed, accurate performance. It is an ideal instrument for use in the field, workshops, and for hobby and home applications. GUARANTEE This product is guaranteed against faults in manufacture for 12 months from purchase date. Keep your receipt as proof of purchase. This guarantee is invalid if the product has been abused or tampered with in any way, or not used for the purpose for which it is intended. The reason for return must be clearly stated. This guarantee does not affect your statutory rights. SAFETY Read this information before using the meter, taking special care regarding any WARNING or IMPORTANT notices. The following safe practices and proper operating procedures should be followed when using any multimeter: Inspect the test leads for insulation damage or exposed metal. Damaged leads should be replaced. Select the proper function and range for your measurement. Avoid severe shocks and do not drop the multimeter. Do not allow the meter to be used if it is damaged or if its safety is impaired. WARNING: TO AVOID ELECTRIC SHOCK, USE CAUTION WHEN WORKING ABOVE 40V DC OR 25V AC RMS. SUCH VOLTAGES POSE A SHOCK HAZARD. Electrically disconnect the live, or hot, test lead before disconnecting the common test lead. Follow all equipment safety procedures. Disconnect the input power and discharge all high-voltage capacitors through a protective impedance before testing in Ω and with the multimeter. Avoid working alone. When making a current measurement, turn the power off before connecting the multimeter in the circuit. Overloading a current shunt will cause excessive heat. When measuring transformer secondary or motor winding current, check the multimeter fuses first. When testing circuits take extra care not to touch any bare metal including the ends of the test probes. The use of makeshift fuses and the short-circuiting of fuse holders is prohibited. Whenever it is likely that the protection has been impaired, the meter shall be made inoperative and be secured against any unintended operation. Never attempt to measure a voltage or current higher than the maximum rating of the meter. CMD50 - Page3

FEATURES Push button ON/OFF power switch. Single 13 position rotary switch for FUNCTION selection. Auto-Ranging. Data Hold function Automatic over-range indication, with OL being displayed on the display. Automatic reverse polarity indication on DC ranges. All ranges fully protected. DC Voltage measurement 100µV to 1000V AC Voltage measurement 1mV to 750V rms DC current measurement 0.1µA to 10A AC current measurement 0.1µA to 10A Resistance measurement 0.1Ω to 32.6MΩ. Capacitance measurements 0.1nF to 32.6µF. Transistor hfe test with l0µa base current. Frequency Range from 10Hz to 200kHz Low Battery indication with + - being displayed on LCD Holster with 2 position stand, and test lead holders to ease the taking of readings whilst holding the meter. SPECIFICATIONS DC Voltage - (Auto ranging) Accuracies are ± (% reading + No. of digits) 326mV ±0.5% of rdg ± 2 digits l00µv 3.26V lmv 32.6V ± 0.3% of rdg ± 2 digits l0mv 326V l00mv 1000V +0.5 of rdg ± 2digits lv Input Impedance: 10MΩ More than l00mω on 326mV range. Resistance Measurement IMPORTANT. When checking-in circuit resistance, ensure the circuit under test has all power removed and that all capacitors are fully discharged. 1. Connect the BLACK test lead to the COM jack and the RED test lead to the V/Ω/F jack. Note: the polarity of the RED test lead is +. 2. Set the FUNCTION switch to the position, and connect the test leads across the resistance to be measured. Note: 1. The Meter may take a few seconds to become stable for resistance over 3.26MΩ. This is normal for high resistance readings. 2. When the input is not connected, i.e. an open circuit, the figure OL will be displayed for the over range condition. Capacitance Measurements IMPORTANT. When checking-in circuit capacitance, ensure the circuit under test has all power removed and that all capacitors are fully discharged. 1. Connect the BLACK test lead to the COM jack and the RED test lead to the ma/cx jack 2. Set the function switch to nf or µe position to be used. Note that the polarity of the red lead is +. 3. Connect test leads across the capacitor to be measured, ensuring correct polarity is observed. Note: The range control mode in capacitance measurement is manual ranging, and only two ranges are provided - 326nF and 32.6 µf. AC Voltage - (Auto ranging) 3.26V lmv 32.6V ± 0.8% of rdg ± 3 digits l0mv 326V l00mv 750V lv Input Impedance: 10MΩ on all ranges. Frequency Range: 40Hz to 1000 Hz CMD50 - Page4 CMD50 - Page9

OPERATION 1. Check the 9-volt battery by setting the ON-OFF switch to ON, if the battery is weak, a + - sign will appear on the display. If this does not appear on the display, proceed as below. See MAINTENANCE if the battery has to be replaced. 2. The mark, or symbol, next to the test lead jacks, is a warning that the input voltage or current should not exceed the indicated values, to prevent damage to internal circuitry. DC Current - (Auto ranging for µa and ma) 326µA 0.lµA 3260µA 1 µa 32.6mA ± 1.2% of rdg ± 3 digits l0µa 326mA 0.lmA 10A ±2% of rdg ± 5 digits 10mA Overload Protection: 0.3A/250V and 10A/250V fuse AC/DC Voltage Measurement WARNING. Use extreme caution measuring high voltages, and do not attempt to measure voltages greater than 1000 Volts, as this can damage internal circuitry. 1. Connect the BLACK test lead to the COM jack and the RED test lead to the V/Ω/F jack. 2. Set FUNCTION switch to V~ or V range to be used and connect test leads across source or load. Reverse polarity is indicated by a sign being displayed in front of the reading. AC/DC Current Measurement WARNING: Do not attempt to measure a current in excess of 10 Amps 1. Connect the BLACK test lead to the COM jack and the RED test lead to the ma/cx jack for a maximum of 300mA. For a. maximum of 10A move the red test lead to the 10A jack. 2. Set the FUNCTION switch to the µa ma or A range to be used, and push /~ button (3) to select D/C A or A/C A measuring mode. 3. Connect the test leads in series with the load in which the current is to be measured. Reverse polarity is indicated by a - sign being displayed in front of the reading. 4. The maximum input current is 300mA, or 10A depending on the jack used. Excessive current will blow the fuse which must be replaced. The fuse rating should be 300mA and 10A and no more to prevent damageto the internal circuitry. AC Current - (Auto ranging for pa and ma) 326µA 0.lµA 3260µA ± 1.5% of rdg ± 5 digits 1µA 32.6mA l0µa 326mA 0.lmA 10A ±3% of rdg ± 7digits l0ma Overload Protection: 0.3A/250V and 10A/250V fuse. Resistance - (Auto ranging) 326Ω ±0.8% of rdg ± 3digits 0.1Ω 3.26KΩ 1Ω 32.6KΩ ± 0.8% of rdg ± 1 digit 10Ω 326KΩ 100Ω 3.26MΩ 1KΩ 32.6MΩ ± 1.2% of rdg ± 2 digits 10KΩ CMD50 - Page8 CMD50 - Page5

Capacitance - (Manual Ranging) DESCRIPTION OF PANEL 326nF ±3.0% of rdg ± 5digits 0.1nF 32.6µF l0nf Frequency 32.6kHz ± 1.2% of rdg ± 3 digit 10Hz 200kHz ± 2.5% of rdg ± 3 digit 100Hz Sensitivity: 200mV up to50k Hz, 1V from 50k Hz to 200k Hz GENERAL CHARACTERISTICS Display Digital Bargraph Measuring Method Overrange Indication Temperature Ranges :3260 counts (3¾ digits). 2/sec update. :32 segments, 12.5/sec update. :Dual-Speed integration A-D convertor system. :Figure OL displayed on the LED. :Operating 0ºC to 40ºC, 32ºF to 104ºF. >75% RH. :Storage ~10ºC to 50ºC 14ºF, to 122ºF. >80% RH. Power Supply Low Battery Indication :One 9V battery (NEDA 1604, 6F22 type or equiv). : + - On left of display. Nomenclature 1. Range Control Button. 2. Data Hold Button. 3. AC/DC Current or Selecting Button. 4. Transistor Test Socket. 5. Function Switch. 6. V/Ω/F Input jack. 7. COM Input jack. 8. ma/cx Input jack. 9. 10A input jack. CMD50 - Page 6 CMD50 - Page7