Note The module converts unipolar and bipolar input signals

Similar documents
1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

5 years! Modular Housings. VariTrans P Warranty

DRG-SC Series Signal Conditioners

CONTA-ELECTRONICS. Converter Units

S200 I/O System Units

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

Coupling Relays and Converters

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

Tel: (949) Fax: (949) IAA100 Product Manual

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DATA SHEET Selectable AC transducer TAS-311DG

Transducer for Measurement Bridges SCM90, SIGS15

ADAM Isolated DC Input/Output Signal Conditioning Module. User s Manual

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Process displays For standard signals, temperature, resistance measurement

Adjustable Digital Process Instrument MDK480

Modicon Momentum automation platform 0

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Switching power supplies CP range, Linear power supplies CP-L range. Content

CAN-IO Custom IO remote module

Monitoring Relay MR 50

P5201 Universal Programmable Transmitters with Galvanic Isolation

VariTrans P V. Safe and Sound.

Theta Hz. Technical Data Sheet. Special Features

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

Datasheet ACT20M Signal Isolation and Conversion NEW

Bulletin 931 Signal Conditioners Technical Data

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

WAVESERIES Signal converters

Electronic timers CT-S range Selection and ordering details

FC Series Signal Conditioners

THE SIGNAL CONDITIONING SPECIALISTS

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

38 Series - Relay interface modules A

High Performance Process & Temperature Controllers

38 Series - Relay interface modules A

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

Theta 20A / 20V. Technical Data Sheet. Special Features

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

RENATO DESIRÒ PARABIAGO (MI) Via Sant Anna, 51 Tel Fax

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

MINI MCR-SL-UI-I-LP-NC

Monitoring Relays 3-Phase Active power Types DWB02, PWB02

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

MACX MCR-UI-UI-UP(-SP)(-NC)

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Signal conditioner - MACX MCR-UI-UI-NC

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Type CP-S, CP-C & CP-A Switch mode

Multifunction Intelligent 4-wire Isolated Signal Conditioner

CP-E range Benefits and advantages

38 Series - Relay Interface Modules A

Analog signal converters CC range

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Excellent low-cost Process & Temperature Controllers

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

FC-33, DC SELECTABLE SIGNAL CONDITIONER

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Conductive Sensors 2 to 4-point level controller Type CL with potentiometer

Watts HCP Series

SINEAX V 604s Programmable multifunctional transmitter

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

DC Current Transducers

MODEL AT-10 ANALOG TRANSMITTER

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Temperature Transmitters - DIN Rail Mounted

48 Series - Relay interface modules A. Features

Pulse Scaler for DIN Rail Attachment

Energy Management Three-phase energy meter with output modules Type EM4-DIN

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Transmitter / Signal Conditioning

MBS AG EMBSIN 120 UV. without auxiliary voltage supply housing for 35 mm DIN rail mounting

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

For non-electrical quantities

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Protection and safety SQZ3 phase and sequence relay

CP-T range Product group picture

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD-F18 Hydraulic-Series. Key-Features:

Analogue Signal Processing

Energy Management Modular Smart Power Transducer Type SPT-90

ISOLATED 4-20 ma TRANSMITTERS

Transcription:

PROGRAMMABLE ANALOG SIGNAL CONVERTER THREE WAY GALVANIC ISOLATOR - 19 input scales - 7 output scales - 1 SPDT alarm contact - input/output isolation 3kV - auxiliary supply output for loop powered sensors - auxiliary supply output for potentiometer function Note The module converts unipolar and bipolar input signals On input section two auxiliary dc output (5V,15V) are available for feeding potentiometers (5V) or remote loop powered sensors (15V), no additional power supply is required, though reducing costs. Connection example: OUTPUT STAGE The output section of the module is suitable for unipolar and bipolar signals (see TAB.2) : LIMITER function is programmable for limiting the output signal to the minimum or maximum scale value in case of input overload or broken wire/sensor. In this case the red LED on front pannel turns on, the relay and its SPDT contact are switched on. The contact output connections are the terminal blocks 5, 6 and 7, and can be used as process alarm. The dimension of 108mm includes the pluggable connection terminal blocks, supplied with the module. * NOTE: the modules are factory calibrated for 4-20mA / 4-20mA. Other possible set-up calibrations are available upon customer request.

Ordering information CA-PI/PO cod. XSSAPIPO Input Technical Data Input signal Inpedance voltage/current 19 scales programmmable 1MΩ / 50Ω Output Technical Data Supply voltage 15 36Vdc Current consumption 100mA max. @ 24Vdc Auxiliary dc outputs max. current 5mA @5Vdc, 30mA @15Vdc Gain error < 0.1% @ full scale Offset error < 0.05% @ full scale Linearity error < 0.1% @ full scale Zero adj ± 10% @ full scale Span adj ± 10% @ full scale Limit frequency 400Hz 1kHz depending on scale Rise time 150mV/µs Bandwidth 1kHz 6dB Phase delay < 10 µs Input/output/power isolation > 3kVac/60sec. Output/contact isolation > 500Vac/60 sec. Continuous input/output isolation 800Vac max. Reference Standards IEC 664-1, DIN VDE0110.1 Overvoltage cathegory 2 Pollution group 2 Operating temperature 10 + 65 C T 5 C Contact rated current 1A /30Vdc, 0,5A /125Vac Protection degree IP30 EMC Standards EN 50081-2, EN 50082-2 Terminal blocks 2.5mm pluggable Housing material poliamyde 6.6, V0 acc. to UL94 Mounting rail EN50.022 Mounting position any, no spacying required Weight 160gr. ca.

CA-PI/PO FUNCTION DESCRIPTIONS LIMITER : with input signal lower or higher than standard levels, or input broken wire, limits the output signal at min. or max. scale levels according to the set-up and makes the relay to turn on ; the module is supplied with LIMITER disabled (dip 1, 8 ON, dip 2, 3, 4, 5, 6, 7 OFF on SW4) ; LIMITER cam be activated by setting SW4, see TAB1, according to unipolar / bipolar input and output scale ZERO ADJ : the trimmer adjusts ±10% the lower signal level SPAN : the trimmer adjusts ±10% the higher signal level Note : turning one trimmer, influence the set point of the other, so few regulations of the two trimmers are necessary to achive the best accuracy. BROKEN WIRE DETECTION : the function works only with voltage or 4-20mA input signal ; set-up JM1 in position A (Neg), B (Pos) or C (None), see TAB.4, and set up the LIMITER acc. to input signal JM1 in position A (Neg) : output signal reaches the full scale negative value 10.05V, 5.05V with bipolar signals ; or 0.1V, 0.05mA, 2mA (with 4-20mA) with unipolar signals ; the contact is switched and the red led is on JM1 in position B (Pos) : output signal reaches the positive full scale value 10.1V, 20.05mA either with unipolar or bipolar signals ; the contact is switched and the red led is on JM1 in position C (None) : the function is off ; output signal is like with 0V input signal ; the function works in any case with 4-20mA input signal if LIMITER is setted- up Note : with current input signal, the function broken wire detection is possible only with 4-20mA signal ; the output signal works as in the case of JM1 in position A, but the jumper have to be setted in position C. LIMITER red led : indicates LIMITER is activated by an input overload, signal lower than minimum, or broken wire, if the function is activated or input set-up is 4 20mA ; with current output set-up, it displays also broken wire on the output ; the red led is on, the contact is always switched POWER green led : power ok TERMINAL BLOCK 1 : positive signal input TERMINAL BLOCK 2 : negative signal input TERMINAL BLOCK 3 : 5Vdc/5mA aux. supply output TERMINAL BLOCK 4 : 15Vdc/30mA aux. supply output TERMINAL BLOCK 5 : relay contact 14 output TERMINAL BLOCK 6 : relay contact 11 output TERMINAL BLOCK 7 : relay contact 12 output

TERMINAL BLOCK 8 : negative signal output TERMINAL BLOCK 9 : positive signal output TERMINAL BLOCK + : positive power supply input TERMINAL BLOCK - : negative power supply input CA-PI/PO MODULE SET-UP The module is programmable by setting the dip-switches on one side of the module, by adjusting the trimmers ZERO ADJ, SPAN, SW3 switch and JM1 jumper bridge accessible by opening the front pannel. ANALOG CONVERTER / ISOLATOR FAST SET-UP PROCEDURE 1-set up input scale by setting SW1, see TAB.1 2-set up output mode voltage/current by setting SW3 on U / I position, see TAB.4 3-set up output scale by setting SW2, see TAB.2 4-if required set up the LIMITER by setting SW4, see TAB.1, and JM1, see TAB.4 5-if required, set up the function broken wire detection by setting JM1, see TAB.4 This procedure mayght introduce an error up to 2% with unipolar/unipolar conversion, up to 4% with unipolar/bipolar conversion and vice/versa, depending on the type of signal and on the scale difference compared with the factory scale set-up (4-20 / 4-20). ANALOG CONVERTER / ISOLATOR PRECISION SET-UP PROCEDURE To get an error 0.1%, connect the power supply and feed the module for a few minutes warm-up time. The needed instruments are : 15 36Vdc stabilized power supply, analog signal generator or a process calibrator, 4½ digit display U/I meter. For the calibration it is raccomanded to use a process calibrator. The accuracy of the calibration depends on the precision of the instuments Procedure A-disable LIMITER function by setting ON dips 1, 8 and OFF dips 2, 3, 4, 5, 6,7 on SW4 B-set-up input scale by setting SW1, see TAB.1 C-set-up output mode voltage/current by setting SW3 on U / I position, see TAB.4 D-set-up output scale by setting SW2, see TAB.2 F-connect the meter to the output terminal blocks 9 (+), 8 (-) G-connect the power supply to terminal blocks + and - and turn on power H-connect the signal generator to the input terminal blocks ; set-up the signal generator at lower level unipolar signal output, (or at the max. negative level wit bipolar signal), adjust ZERO ADJ trimmer to read 0 on the output meter display (or the max. negative level with bipolar signal) ; (set up the signal generator under the min. scale signal to chek the LIMITER function is operating ok if it is activated). I-set up the signal generator to the max. positive signal level ; adjust SPAN trimmer to read on the meter the same signal applied to the input ; (set up the signal generator over the max. signal level to chek the LIMITER function is operating o.k, if it is activated) L-repeat the procedue on points H and I to get the required accuracy J-LIMITER function set-up: turn OFF power ; set-up SW4, see TAB.3, according to choosen scale ; to chek the function is operating ok, repeat procedure on points H and I K-in case of unipolar to bipolar conversion set-up, or vice/versa, it is raccomanded to chek the calibration also at 0 signal level (middle scale)

POTENTIOMETER CONVERSION FAST SET-UP PROCEDURE 1-connect one pole of the potentiometer (value 1kΩ) to terminal block 3 (aux.voltage 5V/5mA potentiometer feeder) 2-connect the cursor of the potentiometer to terminal block 1 (positive signal input) 3-connect the third pole of the potentiometer to the terminal block 2 (negative signal input) 4-set-up input scale to 0-5V by setting SW1, see TAB.1 5-set-up output scale by setting SW3, see TAB.4 and SW2, see TAB.2 6-if required set-up the function LIMITER by setting SW4, see TAB.3 7-if required set-up the function broken wire detection by setting JM1, see TAB.4 8-connect 15 36Vdc power supply to + / - terminal blocks and turn on power POTENTIOMETER CONVERSION FAST SET-UP PROCEDURE To get an error 0.1%, proceed as above up to point 8, then connect to terminal blocks 9 (+) and 8 (-) a 4½ digit display U/I meter for reading the output signal ; wait a few minutes warm-up time, and proceed as follows : 9-turn the potentiometer to 0, adjust ZERO ADJ trimmer for reading 0 on the meter display, or the max. negative value in case of bipolar signal 10-turn the potentiometer to max. and adjust SPAN trimmer for reading the full scale signal on meter display