ROBOTICS DESIGN CHALLENGE. Colorado TSA State Conference (with special thanks to Pennsylvania TSA) Building Collapse

Similar documents
ROBOTICS DESIGN CHALLENGE. Colorado TSA State Conference BUILDING COLLAPSE

PokéBot GO! Rules 1. Participants will have 5 minutes to gain experience points. All team members may have hands on time in controlling the bots.

10 PVC Tree Instructions

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

Water Rocket Launcher

C-Leg Electric Height Adjustable Tables

User Instructions Multiline Otter Scoreboard Caddy Assembly

Instructions for the installation of Handy Well Pump Models HWP-E, HWP and HWP-L. **Read thoroughly before you start!**

2018 First Responders 4-H Robotics Challenge Page 1

BABY WOLF LOOM. Assembly Instructions for Knocked-Down Looms

Instruction Manual for MHE Products DeepWater2 PushPoint Sampler Ver. 2.0 November 21, 2016

Mounting Brackets for 8450 Drawer Slides KV Front Bracket 20 $1.30 KV P Rear Bracket 20 $5.20

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

3DOF Leg Kit Assembly Guide VERSION 1.0

Mueller Gas Products. Mueller H17800 Curb Stop Tee No Blo Curb Stop Tee Weld x Weld 1440 PSI

CADPIPE Industrial Pipe. Tutorial

Pipe Product Catalog Table of Contents

Section. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS

Acrylic Display Manufacturing

ASSEMBLY AND INSTALLATION INSTRUCTIONS

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Assembly Instructions

Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18. Manual 40100X35-8

Preference Collection and Treatment Console INSTALLATION GUIDE

DIY Field Guide ANDYMARK, INC.

This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum.

#11178 Providence ARBOR

what to do with PVC Do It Yourself Fall 2014

MAXYM Mortiser Operating Manual

#11179 Wellington ARBOR

Biomass Briquette Mold

Droplit v2 Frame Assembly

Cosmic Ray Telescope Construction Instructions for 2017 Eclipse Tracking design

Power drill with 5/16 & 7/16 nut driver, 3/16 drill bit, framing square, tape measure and Sharpie.

ORTOP Modular Robot v3.0 Arm Assembly

aluminium profile system

RANGER Class Preview Product Demonstration Inner Space: Rigs to Reefs

HYDRAULIC CONTROL DETAILS PARTS LIST

2018 Border Challenge Robotics Competition

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Pneumatic Clamp Carrier. Installation & Operation Manual

OPERATIONS MANUAL. Port-O-Slitter

8 th Annual Robotics Competition. High School and Middle School Teams. April 5th, Event Rules Booklet. Sponsored by

Installing Body Mounted Kadee Couplers on LGB Housecars

15 Ft. x 39 Ft. Hoop House Construction

411 West Congress St., Maple Lake, MN Toll Free

111628W FodderPro 2.0 Full Feed System Wall Mount

INSTALLATION INSTRUCTIONS

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Triangle Triumph Game Elements. Table of Contents

INSTALLATION INSTRUCTIONS FREE STANDING TUB FILLERS

HOW TO HOME IMPROVEMENT INSTRUCTIONS (Steps to make changes and before and after photos) Entrance to Front and Back of House

FITTINGS. Pneufit C composite and Pneufit M fittings Metric Ø 3 to 16 mm O/D tube

Cablelink Plus Flush Technical

Jass.Performance Low Profiles Installation Manual

Quick-Drain Installation Requirements

THE ROGUE TM GRAND RAPIDS TM ASSEMBLY AND INSTALLATION INSTRUCTIONS

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

Assembly and installation help

Spiral Slide

HALSEY TAYLOR OWNERS MANUAL Contour TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

Quick-Drain Installation Requirements Large Volume Drainage Models

3. Barrier elements. Barrier posts. Stainles steel

PLAYLAND 72 SPIRAL SLIDE 3.5 Posts, 3.5 Posts / 48 Grid and 5 Posts

X-stream Slide Assembly and Installation Instructions

Zip Block MODEL ZB INSTALLATION INSTRUCTIONS

Series B Medical Gas Service Outlet Upgrade Kits

PLASTIC BALLCOCK Includes: Vinyl Refill Tube, Float Rod, Flange Nut, Washer, 5/8 or 1/2 Coupling Nut and Water Level Adjustable Screw.

Before Assembling the Storage Wall

BP Brine Pro Brine Maker. Parts List. This Parts List is for BP-2000 brine makers with serial numbers beginning with and higher.

Legacy Woodworking Machinery a division of Phantom Engineering. The Legacy CNC. Assembly Manual

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.

World Robot Olympiad 2018

Illustrated Parts & Packing List 528 Gandrud Road, Owatonna, MN For a complete distributor & dealer list go to

PORTA~TRACE. GAGNE, INC. 41 Commercial Dr. Johnson City, New York Phone: Fax: ASSEMBLY INSTRUCTIONS

Optical Cable Entry Facility (OCEF) Installation Instructions

System 3000 specifications

Fodder-Pro Feed System

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.

Unit 8: Light and Optics

Job no. 5241_Accessories Brochure_Size: 8.2 x 8.2 _ KOHLER Genuine Accessories

SECTION 9: PARTS Cabinet & Base

LOM-15 CD-LOM15-01 PRODUCT OVERVIEW. Product. Description. Specifications SKU: LOM-15. Duplex Receptacle

Available in high-capacity. and assembled by hand for smooth operation. Durable chrome-plated finish. Heat-treated for long life.

DURASTALL SHOWER STALL ASSEMBLY INSTALLATION REPAIR PARTS FOR ONE OF THE FOLLOWING MODELS:

INSTALLATION GUIDELINES

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4

Strata. urniture Watch our assembly videos at Denali Arms. Parts in the Arm Box: Hardware in this Box:

Poke-Home Thru-Wire: WTW

Hollywood Style. Theater Dressing Room Make-up Mirror Lighting. Beautiful. 2+2 or SLC Decorative Strip Lights

Real Life Ninja Complete Starter Pack (14ft. Warped Wall) Assembly Instructions

PC-196 B-3-A 7-1/2 NYCOPAC BRAKE ASSEMBLIES PARTS CATALOG. Publication 501-TAB 8

Thermoplastic Valves Sewer Disconnect

OPERATIONS MANUAL. Port-O-Slitter

WASP Extended Shuttle Fitting. Process Overview

Scheduling and Motion Planning of irobot Roomba

Aluminum Frame Type Instruction Manual

Major 5001 Wire Stripper

PERSONAL RECORD KEEPING

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

Transcription:

ROBOTICS DESIGN CHALLENGE Colorado TSA State Conference 2017-2018 (with special thanks to Pennsylvania TSA) Building Collapse A building has partially collapsed due to recent earthquake. Search and rescue operations are ongoing, but have been suspended because a gas leak deep inside the building has been discovered. The mission of the team is to navigate through the rubble to the source of the leak and turn off the gas as soon as possible so search and rescue operations may resume. The rescue crews have identified an entry point (Zone 1) in the structure for the robot. It is through this entry point that the robot must enter and exit the structure. Once the gas leak has been located and turned off, the robot must return to the entry point for egress. All robots must start and finish within the 12 x 12 x 12 entry/egress The robot will need to navigate through the structure without disturbing any vertical support beams (vertical [upright] structures that the robot encounters cannot be disturbed, since they may be supporting the structure above). There are eight (8) vertical support columns in the structure that are represented by 12" x 1" diameter PVC pipe, standing on end. These vertical supports are randomly placed throughout the course. Penalty points will be assessed for each support structure that is knocked over. As the search and rescue crews exit the structure, the robot will need to move out of the way to allow them to pass (Zone 2), Each team must park their robot in the designated area in Zone 2. The entire robot must be inside of the parking area (25 long and 16 wide). The wheel(s) or tracks closest to the PVC pipe must be between the designated. Parallel parking is defined as having the side of the robot parallel to the pipe which represents the back wall of the parking area (see illustration below). The rescue teams have identified packed rubble the robots must traverse in order to get through the structure (Zone 3). The team must navigate the robot over packed rubble which is represented by four (4) bags (each containing 80-100 standard sized marbles) arranged in a staggered pattern. The robot will encounter several horizontal members that have fallen in the path of the robot that will need to be flipped out of the way to allow the robot to pass. The robot may not traverse over or around the horizontal members (they need to be moved out of the way) (Zone 4). The horizontal beams are represented by pieces of 1" diameter PVC pipe, each anchored on a pivot at one end. The search and rescue teams have also identified several loose obstacles the robot will need to move to an area they have designated as a safe zone before the gas can be shut off (Zone 5). The rubble in Zone 5 that needs to be moved to a designated safe area is comprised of:

Three (3) - 1" x 1" x 2" wooden cubes Three (3) baseball-sized Wiffle balls Three (3) golf balls The designated safe area is 14" long and 6" wide and parallel to the wall in front of Zone 5. In Zone 6, the robot must turn off the gas leak. The gas shut off valve is represented by a light bulb, controlled by a push button switch. The robot must turn the light off to represent turning off the gas leak. After the robot stops the gas leak it must return to the entry point (Zone 1) for egress. The time stops when the robot has returned and parked in the staging area. The robot may not navigate over any of the PVC pipe defining the course. Time is of the essence; each team has 3 minutes to prep their robot (not practice or modify the robot), and three (3) minutes to enter the structure, navigate the obstacles, shut off the gas leak and return to the entry point for egress.

Materials The Field: ROBOTICS DESIGN CHALLENGE COURSE MATERIALS AND SET UP The field boundaries, vertical and horizontal columns are as specified below. 5 pieces: Schedule 40 1" x 10' PVC Pipe 4 each: Schedule 40 1" x 1" x 1" Tee 5 each: Schedule 40 1 x 1 90 Elbow 4 each: Schedule 40 1 Cap OPTIONAL: Schedule 40 1 x 1 Couplers may be used to connect longer pieces for ease in transporting and storing the field. There is approximately 14 clearance between walls of the demonstration field. PART # LENGTH A 72 B 60 C 57 D 14 E 45 F 15 G 29-1/2 H 15 I 12 J 24 K 12 L 11 M 24

The Field Zones: The Zone 1 Entry/Egress Point: The entry/egress point is a 12 x 12 x 12 area from which the robot must start and return. The robot may expand as necessary once the time starts, but must start and stop within this 12 x 12 x 12 cube. No parts of the robot may extend past this cube until the time starts. Zone 2 - Parking Area: The Zone 2 Parking Area measures 25 L and 16 wide. The entire robot must be clear of the entrance hallway. The robot may parallel, head-on, or back-in park in the Parking Area (see rubric for points for each type of parking). The wheel(s) or track(s) closest to the back wall of the parking area must be in the striped area (as shown in the illustration at the right). Zone 3 - Packed Rubble: The packed rubble is represented by four (4) bags containing 80-100 standard sized marbles. Each bag is made from a lint snare (Ace Hardware #40960) and sealed with a zip tie. The snare filled with marbles is then placed inside a nylon stocking. Final approximate size is 7 L x 1-3/4 H (shown in the illustration at the right).

Zone 4 - Collapsed Beams: The collapsed beams are made from the following materials: 3 pieces - 1" diameter x 12" PVC Pipe 6 pieces - 3/4" T x 2" W x 4" H beam supports 3 pieces - 1/4" Diameter x 4" round stock 1 piece - 1/4" x 20 x 17 plywood for base Each beam fulcrum is 3 from above the base of the obstacle. Double beams are placed 10-1/2" O.C. Single beam centered between double beams. Minimum of 14" clearance between beam supports. Starting Position for the beams: Flipped position for the collapsed beams:

Zone 5 Loose Rubble: The loose rubble the robot must move is made from the following materials: 3 - standard golf balls 3-1" x 1" x 2" wooden blocks 3 - baseball-size Wiffle balls The loose rubble (shown in illustration at the right) is randomly placed in Zone 5. Zone 6 Gas Shut Off Simulator The Gas Shut Off Simulator is made from the following materials or their equivalent: 1 - Push Dimmer (ACE Hardware # 3217205) 1 - Toggle Cover (ACE Hardware # 30299) 1 - Handy Box (ACE Hardware # 30337) 1 - Keyless Plastic Lamp Holder (ACE Hardware #3217171) 1-7-1/2 watt incandescent bulb (ACE Hardware #3179082) 1 - Octagon Box ACE Hardware #30327) 3-3/8" NM Connector 1 Standard plug and wiring for wall outlet power supply Inside dimensions of box are: 6-1/4" W x 8" H x 5-3/4" D. The handy box containing the switch is surface mounted on the inside back wall of the box. The box is mounted on a ¼ piece of plywood 14 W x 14 L. The simulator is shown in the illustration at the right.

Field Set Up: