Datasheet. IndustryAmp PB-800-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Similar documents
PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

AXYS IndustryAmp PB-800

Datasheet. Intellivox - HP-DS370* Applies to Part Number: Intellivox HP-DS370. Datasheet frontpage picture

Datasheet. Applies to Part Numbers: / Intellivox - DC430

Datasheet. Applies to Part Numbers: / Intellivox - DSX280 HD

PowerMatch PM8500 / 8500N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

LBC 3253/xx Intellivox 2c Active Line Array Loudspeakers

LBC 3252/xx Intellivox 2b Active Line Array Loudspeakers

DSP AMPLIFIERS DI

H90. Intellivox ADC-H90. Datasheet EN Shaping the future of sound reinforcement. Applies to Part Numbers: , and

DNA Pro series 10K8 3K8

Vari directional Array

PowerMatch PM8500 / PM8500N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back

PowerMatch PM4250 / PM4250N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

Overview. Features. Technical Data Sheet 1 / 5. Power Amplifier XMV8140-D

FreeSpace IZA 250-LZ / 190-HZ TECHNICAL DATA SHEET. integrated zone amplifier. Key Features. Product Overview. Product Information.

Amplifiers and battery charger

PowerShare PS604A adaptable power amplifier

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

SPECIFICATION. Online UPS 3000VA

FreeSpace IZA 2120-LZ Integrated Zone Amplifier

Technical data sheet 1671 Power amplifier Art. no 19611

NE SERIES. ne Models ne800 ne1600 ne2400

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

PowerShare PS602 adaptable power amplifier

Multi-Channel, Network-Enabled

C1300FDi DSP power amplifier 2x650W, install

MA40E Mini Amplifier with DSP

AX6220Z/AX6240Z. Energy-Efficient, DSP-Powered and Ethernet/USB-Controlled 1000/900-Watt 70/100 V High-Impedance Power Amplifier.

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

MediaMatrix X-Frame 88

The AXYS Intellivox range

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

Protea-Equipped Media Amplifier

OWNER S MANUAL CPS 1 / CPS 2 CONTRACTOR PRECISION SERIES

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

DSA Parts included. Engineering Data Sheet. 4 x 1000 W. Class D. Optimized for permanent installation EN 54-16: 2008

C-Band Redundant LNA Systems

DSA Parts included. Engineering Data Sheet. 4 x 500 W. Class D. Optimized for permanent installation EN 54-16: 2008

Intelligent Acoustic Solutions M E S S E N G E R G 2. D e l i v e r i n g Y o u r M e s s a g e

Parque Tecnológico de Andalucía C/ Severo Ochoa Nº MÁLAGA, ESPAÑA Tlf: Fax:

MA80FT Mini Amplifier

X-Band Redundant LNA Systems

PERMA Series Revision 2 Amplifiers

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Sub218Lac. Self Powered Dual 18 inch Direct-Radiating Subwoofer. product specification. Performance Specifications 1

... yet still led out of the terminal quickly and safely in an emergency.

Specifications MPS 602

Protea-Equipped Media Amplifier

L1 Model I TECHNICAL DATA SHEET. portable line array system. AV-Concept - tlf web: Key Features.

TS212ac. Self Powered Dual 12 inch Direct-Radiating Subwoofer. product specification. Performance Specifications 1

Bosch Communications Systems Get your message across, effectively.

Z4MK3/Z8MK3 : Zone Mixers

FEATURES DESCRIPTION THE OEM ADVANTAGE

Dante. Dante Network Class D Professional Audio Amplifier D-3000

NXP SERIES. nxp Series. nxp nxp nxp nxp nxp nxp nxp nxp 3.02

High Stability Voltage Source

VSX Loudspeaker. Management Systems. VSX Output Filters

CX-A6 Amplifier Installation & User Guide V9.0

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

data sheet MS-HM.01 AUDIO SYSTEM FOR INTEGRATION INTO MEDIA BOARDS

DIGITAL CROSSOVERS AND DSP PROCESSORS

RM28ac. Self-Powered Dual 8 inch Coaxial Reference Monitor. product specification. Performance Specifications 1

MA6480A. Energy-Efficient, Multi-Function 240-Watt Mixing Amplifier with Dual 70/100 V and 4 Ohms Outputs. Features

B850 Boiler House Energy Monitor

The Micromega MyAMP. A serious design challenge

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

AXYS T-2112 data sheet rev 1.1 / GvB / Dec.15 th 1995

FA12ac. Self-Powered 12 inch Coaxial Loudspeaker. product specification. Performance Specifications 1

33609/J Limiter/Compressor

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

VX-3000 Series Voice Alarm and Public Address System

AC/DC Power Supply Series APPLICATION NOTE

TGX10 DSP power amplifier 4x2500W, live

Titan Modular Mainframe Amplifier Cards

MTS Automation P R O D U C T S P E C I F I C A T I O N. MaxPlus Digital Servo Drive. MP-FLX 230 Series. MP-FLX 230 Series. Single- and Dual-Axis

CPS4.5. Electro-Voice CPS x 500 W. High Efficient Class-D Design. Optimized for permanent installation EN 54-16: 2008

The D6 and D12 amplifiers

pêma protea êquipped media amplifier

WPE 48N USER MANUAL Version1.1

High Current, High Power OPERATIONAL AMPLIFIER

A6500-UM Universal Measurement Card

Correlation of Voltage and Temperature Measurement

TL082 Wide Bandwidth Dual JFET Input Operational Amplifier

Harman Pro Group Section: POWERED BY. Full Line Catalog Installed Sound Commercial Audio Portable PA Tour Sound Cinema Sound.

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

Josephson Engineering, Inc. 329A Ingalls Street Santa Cruz, California Josephson Engineering Rev B

Advanced Test Equipment Rentals ATEC (2832)

Boulder W Class A Stereo Power Amplifier

Tel. 0621/ FAX 0621/

PAM & SAM System User s Manual

PRELIMINARY AA35G/AA60G. 3-Input, 35-Watt Mixer Amplifier with Global Power Supply

L1 Model 1S TECHNICAL DATA SHEET. portable line array system. Key Features. Product Overview. Technical Specifications

DX 48 DX 24 DX 12 D X - S e r i e s

audionet AMP 1 V2 User s Manual Stereo - Amplifier

RoomMatch Utility Small-Format Loudspeakers. Award-winning RoomMatch sound for zone-fill/foreground music applications

Danley Sound Labs. DNA 5K4c DSP Amplifier. User Guide version 2

Portable Speakers. 2,500 Watt 2 Way 15" Loudspeaker with KLARK TEKNIK Digital Signal Processing and ULTRANET Networking

Transcription:

PB-800 800-CN Datasheet Applies to Part Number: 590803 IndustryAmp PB-800-CN * *This unit has a CobraNet interface installed

User Notice: No part of this document including the software described in it may be reproduced, transmitted, transcribed, stored in a database system or translated without the express written permission of Duran Audio BV. Documentation kept by the end-user for backup purposes is excluded from the above mentioned. All products and corporate names mentioned in this document may be registered trademarks or copyrights of their respective companies. They are used here for indicative purposes only. The information contained in this document has been carefully checked for accuracy, however no guarantee is given with respect to the correctness. Duran Audio BV accepts no responsibility or liability for any errors or inaccuracies that may appear in this document or the products and/or software described in it. Specifications and information contained in this document are subject to change at any time without notice. 2 201605/PB800CN_2.2

Table of Contents 1. Architectural and engineering specifications...................................4-5 2. Specifications...........................................................6-8 3. Measurement Plots........................................................9 4. Functional Diagram.......................................................10 5. Mechanical Details.....................................................11-12 6. DSP block diagram........................................................13 7. Optional Accessories......................................................14 201605/PB800CN_2.2 3

1. Architectural and engineering specifications The unit shall be constructed in a 3U 19 rack enclosure. It shall be a multi channel power amplifier with on-board DSP and RISC processor that is intended for use in distributed 70V/100V professional audio installations. All signal processing functions, necessary to properly control and monitor each amplifier channel shall be implemented on-board in order to reduce the overhead costs related to external processors. The electronics shall consist of a 2 channel analogue audio input module, 8 digital audio inputs and 8 digital audio outputs via CobraNet, a Digital Signal Processor with 10 inputs and 8 outputs, 8 class AB power amplifiers with protection circuitry and a high power switched-mode power supply with a very high peak power capability. The analogue audio inputs shall be transformer balanced. All necessary signal processing shall be implemented in the digital domain by means of a 32 bits floating point DSP. The DSP shall realize appropriate output channel gain, equalisation filters and delays. Besides the aforementioned, the DSP shall be able to realize EQ, pre-delay, volume and autogain, and compression as required. The DSP software and coefficients shall reside in non-volatile memory in order to facilitate adaptations and software updates. Audio AD and DA conversion shall be performed with high quality 24 bits converters. The output section shall be equipped with high-grade toroidal transformers to provide both 70V and 100V outputs. All loudspeaker terminals shall be protected against voltage spikes by means of gas discharge devices. The 8 outputs shall be driven by full complementary class AB amplifiers equipped with rugged industrial power mosfet devices capable of handling large currents without risk of failure. There shall be a large phase margin within the feedback loop to keep the amplifiers stable under any load condition. Each amplifier shall be capable of delivering 100 W rms into a 100 Ω load. 4 201605/PB800CN_2.2

The device shall be controllable over RS-485 as well as over Ethernet. The RS-485 interface shall be implemented as a fully isolated fullduplex serial network interface. Access over Ethernet shall be realized by using the CobraNet Serial Bridge protocol. This control unit shall serve four main functions: Remote monitoring of parameters like status of the DSP, amplifiers and their loads, monitoring and control of the internal fan, external pilot tone detection, status of the optional ambient noise sensing microphone, thermal overload protection, ambient noise level, ambient temperature, control for the input section etc. Remote control of DSP parameters: volume, pre-delay, EQ, output sections, autogain configuration and surveillance related parameters. The analogue audio signal shall be connected to a Phoenix type MC 1,5/ 3-ST-3,81 connector. The device shall be equipped with two RJ-45 sockets to allow connection to a fully redundant CobraNet network. The RS-485 signal shall be connected to a Phoenix type MC 1,5/ 5-ST-3,81 connector. Each of the amplifier outputs shall be connected to Phoenix type GIC 2,5/ 3-ST-7,62 connectors. The unit shall be equipped with a Neutrik Powercon mains inlet connector. The enclosure shall be constructed of steel finished with a nickel plating. All connectors, as well as the mains switch and fuse holder, shall be located on the rear of the enclosure. The front of the enclosure shall accommodate a bi-colour LED to indicate the status. Dimensions are: 132 mm H x 483 mm W x 342 mm D. Weight 22.6 kg. The amplifier unit shall be the AXYS model IndustryAmp PB-800-CN. Updating DSP software and factory unit programming. Configuration of the CobraNet (Ethernet interface only). node The device shall provide failure relay contacts for monitoring purposes. The failure relay connections shall be configurable for either 'volt-free' or 'impedance-sensing' operation (to allow for a direct connection to impedancesensing monitoring equipment). 201605/PB800CN_2.2 5

2. Specifications Electrical: Analogue Audio Inputs 1 - Number of inputs : 2 - Nominal level : 0 dbv (RMS, line input) - Maximum level : +19 dbv (peak, line input) - Type : dual line input, transformer balanced - Impedance (balanced) : 6k8 Ω - Frequency range : 70 to > 20k Hz (-3 db, analogue in to amp out, 100 Ω load) - CMRR : > 55 db (1k Hz), > 60 db (50 Hz) Digital audio interface 2 - Number of inputs : 8 - Number of outputs 3 : 8 - Format : 48 khz / 24, 20 or 16 bit - Type : Dual 100 Mb/s CobraNet Ethernet (IEEE 802.3u) connection General - Dynamic range 4 : > 90 db - THD + N : < 0.05 % @ 1k Hz (50 V rms in 100 Ω) < 0.2 % @ 50 to 10k Hz (50 V rms in 100 Ω) DSP module - Type : floating point 900 MFLOPS 32 bits - Memory 5 : 128 Mb SDRAM + 10 Mb non volatile - AD - DA conversion : 24 bits sigma-delta 128 x oversampling - Auxilliary processor : single cycle RISC - Sample rate : 48.0 khz (default) - Latency : 3.45 ms (analogue in to amp output) - Signal processing : - input channel delay (10 x 1.3 seconds) 5 - main pre-delay (21.8 seconds) 5 - output channel delay (43.6 seconds per output) 5 - equalizer - volume - individual RMS and peak limiters on each output - ambient noise level dependent gain adaptation ( fail-safe ) - eight output filters + delay ringbuffers - individual output EQ, gain and polarity control - input configuration (10 inputs) - CobraNet transmission routing : - Slot 1 ANS mic - Slot 2 Analogue out 2 - Slot 3 Analogue out 3 - Slot 4 Analogue out 4 - Slot 5 Analogue in 1 - Slot 6 Analogue in 2 - Slot 7 Analogue in processed 1 (before input selection processing) - Slot 8 Analogue in processed 2 (before input selection processing) 6 201605/PB800CN_2.2

Control & monitoring - Interface 6 : RS-485 or CobraNet Serial Bridge protocol - RS-485 interface type : serial full-duplex RS-485, autoswitching 115k2, 57k6, 38k4,19k2 baud, optically isolated - Maximum number of units 7 : 126 units - Remote surveillance : - general status (DSP running, signal present etc.) - amplifier monitoring and load monitoring schemes - pilot tone detection on analogue inputs (20k5-28k Hz, level > -22 dbv) - pilot tone detection on CobraNet inputs (19k2 to 23k5 Hz, software configurable threshold) - monitoring of optional external ambient noise sensing microphone - frost protection - fan monitoring and control for internal fan - thermal overload protection - Failure : - internal hardware bypass circuit for analogue audio inputs - failure relay (external connector, maskable conditions) SPDT 100 ma / 24 V - configurable for volt-free or impedance-sensing (10k / 20k Ω) operation (internal jumper) - failure status indicated at front by bi-colour LED - Load monitoring freq : 22k Hz - Load monitoring level : 8 V rms (unloaded) - Load monitoring maximum impedance :1600 Ω @ 22k Hz Power amps - Type : Full complementary FET class AB - Power : 8 x 100 W rms (100 Ω) - Protection :-DC failure - Short circuit - Output transformers : Toroidal - Taps : 70 V, 100 V - Minimum load : 100 Ω (@ 100 V), 50 Ω (@ 70 V) - Loudspeaker terminal surge protection clamping : 350 V @ 20 ka Connectors 8 - Analogue audio inputs : Phoenix type MC 1,5/ 3-ST-3,81 (2 x) 9 p1 = Line 1 +, p2 = GND, p3 = Line 1 - - CobraNet interface : RJ-45 (2 x) 2 - RS-485 interface : Phoenix type MC 1,5/ 5-ST-3,81 p1 = DGND, p2 = Y, p3 = Z, p4 = B, p5 = A - Ambient noise sensor : Phoenix type MC 1,5/ 3-ST-3,81 p1 = In +, p2 = GND, p3 = In - - Ambient temperature sensor (NTC) : Phoenix type MC 1,5/ 2-ST-3,81 p1 = In, p2 = GND - Failure relay : Phoenix type MC 1,5/ 3-ST-3,81 p1 = Common (CO), p2 = Normally closed (NC), p3 = Normally open (NO) 10 - Loudspeakers : Phoenix type GIC 2,5/ 3-ST-7,62 (8 x) 11 p1 = 0, p2 = 70 V, p3 = 100 V - Mains : 3p male Neutric Powercon 201605/PB800CN_2.2 7

PSU - Type : Switched-mode, power factor correction, standby supply - Rated mains voltage : 100 V to 240 V, 50 or 60 Hz - Mains fuse(s) : 1 x 8 A quick-blow/anti-surge 20 x 5 mm glass fuse (type F8A HBC) - Power consumption 12 : - 60 W (idle) - 11 W standby (main power supply shut down) - 134 W load monitoring active (all outputs 100 Ω) - 1000 W (rated full load) - Power factor : 0.50 (idle) / > 0.90 (full load) - Max mains inrush current : 20 A short-time peak (@ 230 V) - Protection : - thermal protection - output current limiting - under-voltage and over-voltage lock out Fans - Type : large low-speed temperature-controlled fans - Number of fans : 2 - Airflow : rear to front General: Temperature range (ambient) : 0 to 40 C (32-104 F) Dimensions (H x W x D) : 132 x 483 x 342 mm (3U 19 rack enclosure) Weight : 22.6 kg (50 lbs) Finish : Nickel Plated MTBF 13 : 70000 hours Standards - EMC : EN 55103-1:1996; E1, E2, E3 EN 55103-2:1996; E1, E2, E3 - Safety : IEC 60065:2001 (ed7) +A1:2005 +A2:2010 - Mains harmonics : EN 61000-3-2:2001 Certificates : CE Notes: 1. The device supports 2 analogue audio inputs and 8 digital CobraNet inputs. 2. The device is equipped with 2 RJ-45 sockets for a redundant CobraNet connection. 3. Various signals can be routed to the 8 CobraNet transmit channels, see section 'DSP block diagram' for details. 4. A-weighed, 10 to 22k Hz analyzer bandwidth, open input, 100 Ω load. 5. Devices with early serial numbers are equipped with 64 Mb SDRAM, this halves the maximum available delay times. 6. The device can either be accessed over RS-485 or over Ethernet by using the CobraNet Serial Bridge protocol. The interfaces cannot be used simultaneously. 7. Maximum number that can be connected to one subnet, multiple subnets can be controlled by one host PC. This also applies when accessing over the CobraNet Serial Bridge. 8. All Phoenix type numbers refer to the required cable parts, a complete set of Phoenix connectors is supplied with the product. 9. For solid and stranded wires with conductor cross sections from 0.14 to 1.5 mm 2. 10. For volt-free operation CO is connected to NC if the device is powered and the status is OK (no masked failure). 11. For solid and stranded wires with conductor cross sections from 0.2 to 2.5 mm 2. 12. Typical values, valid for nominal operating temperature of the amplifier. 13. At ambient temperature of 20 C. 8 201605/PB800CN_2.2

AXYS IndustryAmp PB-800-CN data sheet rev 2.2 3. PB-800-CN measurement plots Fig 1 CMRR versus frequency. Fig 2 Magnitude vs frequency, 100 Ω loaded, 36 Vrms out @ 1k Hz. Fig 3 FFT of residual noise with input 1 active (shorted), 100 Ω load. Fig 4 THD+N vs frequency, 100 Ω load, 50 Vrms output level (@ 1k Hz). Fig 5 THD+N vs output level, 1k Hz, 100 Ω load, output limiters not active. Fig 6 THD+N vs output level, 1k Hz, 100 Ω load, output limiters with default params. 201605/PB800CN_2.2 9

4. Functional Diagram (part number 590803) Bypass To Amps Load Amps Relays Monitoring Transformers Surge Protection Input 1 1 Out 1 Input 2 Digital Inputs 3-10 CobraNet DSP Processing 2 3 4 Out 2 Out 3 Out 4 5 Out 5 6 Out 6 x8 7 Out 7 Digital Pilot detect Analogue Pilot detect 8 Out 8 CobraNet 8 x Digital Outputs CobraNet Serial Bridge Ambient Noise Sensing Mic RS-485 Ambient Temperature Sensor External Failure Relay Micro Controller Internal Temperature Fan Monitoring Front LED Mains PSU Internal Supplies 10 201605/PB800CN_2.2

5. Mechanical Details (part number 590803) Front Panel 1 Rear Panel 4 2 3 5 8 9 10 11 19 20 R 18 17 7 6 12 13 14 15 16 1. Status LED bi-colour LED: normal (green), failure (red) 2. Failure relay connector 3. ANS microphone input 4. RS-485 network interface 5. Ambient temperature sensor connector 6. Analogue input 1 7. Analogue input 2 8. Output 1 (100 V / 70 V) 9. Output 2 (100 V / 70 V) 10. Output 3 (100 V / 70 V) 11. Output 4 (100 V / 70 V) 12. Output 5 (100 V / 70 V) 13. Output 6 (100 V / 70 V) 14. Output 7 (100 V / 70 V) 15. Output 8 (100 V / 70 V) 16. Mains power connector 17. CobraNet Port A 18. CobraNet Port B 19. Mains switch 20. Mains fuse 201605/PB800CN_2.2 11

5. Mechanical Details (part number 590803) 57,15 132 118 127 482,6 333 342 432 438 12 201605/PB800CN_2.2

6. DSP Block Diagram DIGITAL - via CobraNet ANALOGUE INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 INPUT 7 INPUT 8 INPUT 9 INPUT 10 P R I O R I T Y S W I T C H I N G EQ 8 band parametric EQ DELAY 4 band parametric GAIN Cobra xmt 5 Cobra xmt 7 Cobra xmt 6 Cobra xmt 8 OPTIONAL EXTERNAL MICROPHONE DELAY VOLUME AUTO GAIN Cobra xmt 1 DELAY 1 2 3 4 5 6 7 8 4 band parametric EQ GAIN & POLARITY Cobra xmt 1 Cobra xmt 2 Cobra xmt 3 Cobra xmt 4 Cobra xmt 5 Cobra xmt 6 Cobra xmt 7 Cobra xmt 8 To CobraNet Outputs T O A M P L I F I E R S Cobra xmt 3 Cobra xmt 4 Cobra xmt 2 201605/PB800CN_2.2 13

7. Optional Accessories Ambient Noise Microphone and Temperature Sensor Order code: 97661101 USB-RS485 converter Includes Wincontrol and Drivers Order code: 387802 WinControl Server Order code: 386600 14 201605/PB800CN_2.2

DURAN AUDIO BV Koxkampseweg 10, 5301 KK Zaltbommel, The Netherlands. tel. +31 418 515583 fax. +31 418 518077 http://www.duran-audio.com Info@duran-audio.com