WIREMOLD Flushduct Infloor Duct System

Similar documents
WIREMOLD Access 5000 Series Raceway

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

The 400, 800, and 2300 Series Raceways, from

WIREMOLD AL7450 Series Isoduct Aluminum Raceway

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

The V2100 Series Steel Raceway provides wiring

Flush Round Single or Multi-Service Non-Metallic Concrete Floor Box Floor Boxes

Floor Boxes. Flush Service Floor Boxes

Multi-Service Pedestal Table Boxes for Laboratory Applications

DS4000/ALDS4000 Prewired Raceway

Assembly Instructions

Cable Management Solutions with DLP TM

TECHNICAL INFORMATION

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

Vista CP Consolidation Point

This attractive raceway conceals and

Track Rack. * Track Racks are not lockable

Figure A. Figure B. Figure C. Figure D

Floor Boxes. Table of Contents

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

Metal Components Incorporated

New Product Release: October 2014 Boone Racks

Factory Assistance: Phone: Fax: Page 1

Open Up Your View With CABLE SYSTEMS

Flush Floor system LIMOGES Cedex. Phone : Fax :

K.D. LOCKER ASSEMBLY INSTRUCTIONS

Raised Floor system LIMOGES Cedex. Phone : Fax :

FLOOR BOX KITS BOXES TRIM KITS ACCESSORIES

Gross Automation (877)

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Cablelink Plus Flush Technical

Trim & Auxiliary. Table of Contents

Subject: P0052 Bed Locator Installation Instructions

Parts list continues on Page 2 HOUSE PARTS PACKED IN HOUSE BOX PARTS IN SMALL PLASTIC BAG (HARDWARE) POST PARTS PACKED IN THIS BOX (LARGE PLASTIC BAG)

Installation manual. For setting in concrete/on base plates - Panel height 1830

Modular Gazebo Kit Series GardenHouse 12

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

OXYGEN INSTALLATION. Revision date

Lid, Floor Monument and Two Installation Fixtures. Floor Monument Installed with Lid On and Off

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

Our Marketing. Our Group. Our Mission. Our Quality Achievements

AUXILIARY FRAMING AND ACCESSORIES

Horizontal Cable Systems

Type 316SS Backed Conveyor Strip Brush Nylon Bristles, 6" O'all HT, 2' Lg, 3/16" Backing

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

Piper GI Conduits. Heavy Gauge Welded GI Conduit, threaded

INSTALLATION INSTRUCTIONS

ADJUSTABLE MOUNTING POST

300 Series Racks. 19" Wide Opening Stand-Alone Wall Cabinet with Adjustable Rails. Applications. Features. In The Box. Options

MX150L tm INDUSTRIAL SEALED CONNECTOR SYSTEM

SECTION COMMON WORK RESULTS FOR HVAC

March 1, Fax:

SLIDING DOOR SYSTEM_ S34 PRODUCT LIST. System description Accessories

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

OptiLine 45 Floor boxes

Floor Stops - Dome. FS13 Dome Stop. FS17 Dome Stop. R14 Riser. Features:

SpeedPRO Raceway System

Kiosk Solution W1000. Installation and Assembly Instructions July 2015 Edition

ACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES WIRE MESH PARTITION FOLDING GATE

COWO. Customer Wall Outlet. 1 General. 2 Kit content. 3 Handling of the box. TC-1203-IP Rev A, Apr

J-BOX. 3-O or 4-0 MUD RING J-BOX BRACKET BAR CABLE GRIPPER/ CANOPY MOUNTING STUD 8-32 BRACKET BAR SCREWS CANOPY STRAIN RELIEF POWER CORD CANOPY

6 Foot/ 1800mm Aisle Width Net-Contain Aisle Containment for N-Type and S-Type Cabinets

KITS BOXES TRIM KITS ACCESSORIES

Calf-Tel Pen System Assembly Instructions

Mast Solutions Document/Installation Manual

Installation Guide 888-4WB TRAY

TrendWall Floor-To-Ceiling Panels Installation Instruction

BIKE FILE (301)

General Information...SA1-SA4

N Nail on mounting H Face bracket for steel and wood stud mounting QT Quick Thread device hole option 16 Bar hanger max 16 joist spacing

19-in. Mini-Rack Cabinet, Type 1

Phone: Installation Instructions

A - Railing Frame Material Specifications

THRESHOLDS. Finishing Touch for Floor Closer Installations

END FEED INSTALLATION

Heat Exchanger Coil: Build Instructions

POWER, VOICE AND DATA ACCESSORIES FOR TRUNKING

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

PCS. Patient Security Service Console. Installation Instructions.

Clearview Railing System Installation Instructions

Assembly Instructions

Thru Wall Floor Seals For New Installation

Pressure Vessel Assembly Instructions

MC CHANGER CABINET INSTALLATION INSTRUCTIONS

Standard Product. Free-Stand Cabinets 19-in. Mini-Rack Cabinet, Components and Accessories

ED3000 Series. Exit Device Parts Manual

Squeeze-Eze Power Packs and Jaws

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

table of contents Sliding Door Accessories Page Latches & Snuggers Stay Rollers Brackets & Stops

Cable Hanging Instruction Manual

Angled Side Flush with Panel Face

Belham Living Harbor Bay Pergola

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE

Modular Gazebo Kit Series Victorian / Queen Anne 9

Transcription:

Thin infloor duct system provides maximum flexibility for renovations Wiremold Flushduct Infloor Duct System is available in 1, 2 or 3 duct combinations and installs flush with the finished floor. The system s slim design enables installation in projects with shallow concrete pours and also allows Flushduct to be used in retrofit applications. It s an ideal system for retail locations as well as any renovation project. Ducts include factory-installed screw plugs which can be activated after installation with a variety of pedestal service fittings. See page 5 for more information on fittings. Flushduct is intended to be fed with junction boxes or by conduit feeds. WIREMOLD Flushduct Infloor Duct System Flushduct Infloor Duct System with Junction Box. FEATURES & BENEFITS n Flush installation simplifies locating and accessing the system after installation n System works with a variety of pedestal style service fittings n Minimum system depth for distribution/feeder runs is 1 3/8" [35mm] n Minimum system depth for systems with junction boxes is 2 ½" n Constructed of 14-gauge galvannealed steel ED763R7 Updated May 2015 For latest specs visit www.legrand.us/wiremold

Walkerduct Flushduct Infloor Duct System Layout 334F-1-3 3222FB 336F-3 3222FST 3222F-0 3222FCSA-28 525 Series Fitting 255-1 338F-3 12F-0 Single Duct Blank Duct For feeder runs with 222F-0 Double Duct precise placement of openings. 3222F-0 Triple Duct Double and Triple Duct Systems are welded together. 10' [3.048m] standard length. Walkerduct Flushduct Duct Ordering Information 12FST Single Duct Ducts Provided with 1 5/8" 222FST Double Duct [41mm] diameter threaded 3222FST Triple Duct openings and removable plugs for service fitting attachment. Openings are staggered 24" [609.6mm] to facilitate placement of service fittings. 10' [3.048m] standard length. Walkerduct Flushduct Coupling & Supports Ordering Information 12FC Single Duct Couplings Used to couple ends 222FC Double Duct of duct together. Set screws used 3222FC Triple Duct to hold duct in place. 12FCS Single Duct Couplings/Supports Provides 222FCS Double Duct 1" [25mm] vertical adjustment 3222FCS Triple Duct and couples ends of duct together. Recommend at 5' [1.524m] intervals. 2

12F-WS Single Duct Blank Washer For closing off 222F-WS Double Duct unused junction box opening. 3222F-WS Triple Duct A dimension is 3 3/16" 1/2" [12.7mm] 1 1/4" [32mm] A [81mm] for 12F-WS, 6 5/16" [160mm] for 222F-WS, and 9 7/16" [240mm] for 3222F-WS. 334UF Single Duct Terminal Bushing For 334F-1-2 Double Duct securing Flushduct to cabinet. 334F-1-3 Triple Duct A dimension is 4 1/8" [105mm] for 334UF, 7 5/8" [194mm] for 334F-1-2, and 11 11/16" [281mm] for 334F-1-3. A Walkerduct Flushduct Fittings Ordering Information 336F Single Duct Vertical 90 Elbow For 336F-2 Double Duct extending Flushduct up wall. 336F-3 Triple Duct 4" [102mm] bend radii. 336F 6 1/4" [159mm] 336F-2 9 3/8" [238mm] 336F-3 338UF Single Duct Horizontal 90 Elbow 338F-2 Double Duct For turning corner with duct. 338F-3 Triple Duct 304 End Cap To close off end 1 1/8" [29mm] of duct. 1/2" [12.7mm] 255-3/4 [19.1mm] Box Conduit Corner -1 [25mm] Adapter For one conduit. -11/4 [32mm] Suffix denotes conduit -11/2 [38mm] trade size. -2 [51mm] Catalog No. "A" Dimension 2 1/4" [57mm] A Inches [mm] 255-3/4 1 7/8 [48mm] 255-1 1 7/8 [48mm] 255-1 1/4 2 1/4 [57mm] 255-1 1/2 2 1/4 [57mm] 255-2 2 3/4 [70mm] 312F-1 [25mm] Conduit Adapter Used to 312F-11/4 [32mm] feed single conduit into end of 312F-11/2 [38mm] A duct. Suffix denotes trade size. Catalog No. "A" Dimension "B" Dimension Inches [mm] Inches [mm] 312F-1 1 3/8 [35mm] 2 1/4 [57mm] 312F-1 1/4 1 11/16 [43mm] 2 7/16 [62mm] B 312F-1 1/2 3 1/8 2 3/4 [70mm] 338UF 338F-2 6 1/4" 338F-3 9 3/8" [159mm] [238mm] 342F Single Duct Horizontal 45 Elbow 342F-2 Double Duct For turning corner with duct. 342F-3 Triple Duct 342F 362F Single Duct Vertical Offset to 362F-2 Double Duct accommodate 1 3/8" [35mm] 362F-3 Triple Duct change in system depth. 362F 30" [762mm] 342F-3 25 1/4" [641mm] 342F-2 9 3/8" [238mm] 362F-2 27 1/2" [699mm] 6 1/4" [159mm] 6 1/4" [159mm] 324-3/4 Male Conduit Adapter Fits into end of No. 2 1 1/2" duct. For two 3/4" trade [38mm] size conduits. 362F-3 38 5/8" [981mm] 9 3/8" [238mm] 38 5/8" [981mm] 332F Single Duct Vertical 90 Elbow For 333F-2 Double Duct extending Flushduct up wall. 1 1/2" [38mm] bend radii. 3 7/16 [87mm] 6 9/16 [167mm] 372F 38 5/8" [981mm] Vertical Offset to accommodate 1 3/8" [35mm] change in system depth. 3 7/8" [98mm] 3 7/8" [98mm] 19 5/16" [490mm] 4" [102mm] 332F 4" [102mm] 332F-2 3

Walkerduct Flushduct Junction Box Ordering Information 12FB Single Duct Junction Box Used at duct intersections. Provide access to system for pulling and 222FB Double Duct splicing of wires. Constructed of cast iron. Interiors of two- and three-duct boxes 3222FB Triple Duct have partitions isolating each duct and forming a continuous raceway through the box. Conduit openings located at each corner of box. 12FB Single Duct 222FB Double Duct 3222FB Triple Duct 2 1/2" [64mm] 2 1/2" [64mm] 2 1/2" [64mm] 9 9/16" [243mm] 12 1/2" [318mm] 16" [406mm] 6LHX-* For 12FB Junction Box Carpet or Tile Holder Flanged stainless steel or brass holders recessed to hold 7LHX-* For 222FB Junction Box carpet or tile. NOTE: X= S for Steel or B for Brass. 10LHX-* For 3222FB Junction Box * Specify 1/8 or 1/4. 544021 Screw Plugs For threaded 544022 openings in Flushduct. 544022 (1 5/8" [41mm]) supports current FST System. 544021 (1 1/4" [32mm]) supports previous (now obsolete F Flushduct System). 7140F Brass Marker Screw Plug For 1 5/8" 7141F Zinc [41mm] threaded openings in Flushduct. Used to designate service in each duct. 450F-1 Brass Ferrule Used to create 450F-11/4 access into duct at a custom location.with internal threads for 1" [25mm] or 1 1/4" [32mm] nipple or standpipe. To install in Flushduct, field cut 1 1/2" [38mm] hole for 1" [25mm] ferrule (450F-1) or 1 7/8" [48mm] hole for 1 1/4" [32mm] (450F-1 1/4) ferrule. 450FP-1 450FP-11/4 Walkerduct Flushduct Afterset & Finishing Components Ordering Information Brass Plug Threads into brass ferrule to close deactivated opening. Use 450FP-1 for 1" [25mm] opening and 450FP-11/4 for 1 1/4" [32mm] opening. 455F-3/4 Threaded Outlet Flange 455F-1 For locking nipple or standpipe. 455F-3/4 is 3/4" [19.1mm] and 455F-1 is 1" [25mm]. 455FP-3/4 455FP-1 Die-Cast Plug Threads into 455F Outlet Flange. Use 455FP-3/4 with 455F-3/4 and 455FP-1 with 455F-1. 470F-1 Crimping Tool Used to install 470F-11/4 450F Brass Ferrule. 470F-1 is 1" [25mm] and 470F-11/4 is 1 1/4" [32mm]. 1124F-3/4 Locking Nipple 1124F-3/4 is for 1124F-1 3/4" [19.1mm] IPS opening, and 1124F-1 is for 1" [25mm] IPS opening. Both 1124F-3/4 and 1124F-1 are 5/8" [15.9mm] long. 4

500RT Faceplate Single opening. Ortronics Series II and TracJack adapters included. 500ACT Faceplate 2 5/8" [67mm] Single opening. Activate CM-MABadapter included. 4 7/16" [113mm] 525 Series Service Fitting Ordering Information 500SP- Faceplate Single opening. Suffix indicates hole diameter. SUFFIX HOLE DIAMETER 1/2 1/2" [12.7mm] 7/8 7/8" [22.2mm] 1.0625 1.0625" [27mm] 1 1/8 1 1/8" [29mm] 1.39 1.39" [35mm] 1 7/16 1 7/16" [37mm] 1 1/2 1 1/2" [38mm] 1 9/16 1 9/16" [40mm] 1 5/8 1 5/8" [41mm] 2 2" [51mm] 500B Faceplate Blank. 500DR Faceplate For single duplex receptacle. 500-MAAP Faceplate Accepts Extron Electronics MAAP device plates. 500-GFI Faceplate For Decora or GFI device. 500T Faceplate 1" [25mm] I.D. grommeted hole. 525HB Housing and Base Plate Only. 5

525 Series Service Fitting Ordering Information (continued) 436-2 -7/8 [22.2mm] Afterset Inserts for Duct -11/2 [38mm] 2" [51mm] IPS. 2 1/2" [64mm] -2 [51mm] core drill size; 2 1/4" [57mm] -23/8 [60mm] hole saw size. Suffix -3 [76mm] denotes height. 825SFCK Conversion Kit To attach service fitting to 800 Series floor boxes. Includes 825C Ring, 1124L-1 Locking Nipple, and 825P-1 Adapter. 424-3/4 [19.1mm] Extensions For 2" [51mm] -1 [25mm] IPS preset or afterset inserts. Suffix denotes height of extension. 430S505 Single Trim Plate To attach fitting to Walkerduct Pro Series Preset. Base of 525 fitting not needed. 1126A-1/4 [6.4mm] Adapter To change 2" [51mm] -3/4 [19.1mm] IPS preset or afterset to -1 [25mm] reduced opening size. -11/4 [32mm] Suffix denotes opening size. -11/2 [38mm] 431D505 Double Trim Plate To attach two fittings to Walkerduct Pro Series Presets. Base of 525 fitting not needed. 1124-1 [25mm] Locking Nipple For 1" [25mm] IPS opening; 1" [25mm] long. 1124L -1 [25mm] Locking Nipple For 1" [38mm] IPS opening; 1 1/2" [38mm] long. 428B525 Flush Carpet Plate To attach to Walkerduct Pro Series Plate. Includes hardware. 1124-11/4 [38mm] Locking Nipple For 1 1/4" [32mm] IPS opening; 1" [25mm] long. 1124L -11/4 [38mm] Locking Nipple For 1 1/4" [32mm] IPS opening; 1 1/2" [38mm] long. 1124F -1 [25mm] Locking Nipple For 1" [25mm] IPS opening; 5/8" [16mm] long. For use on Flushduct Infloor Raceway. 455F-1 Outlet Flange For 1 5/8" [241mm] diameter opening on Flushduct Infloor Raceway. Accepts 1" [25mm] locking nipple. Cross Reference OLD CATALOG NUMBER NEW CATALOG NUMBER 505A, 501E 525A 505ACT 525ACT 505B, 502E 525B 505C, 503E 525C 505F 525F 505G 525G 505H, 523E 525H 505HB 525HB 505I 525I 505J 525J 505RT 525RT 1044B 1044S 1045B 1045S 1046B 1046S 1043B 1043S For 3/4" IPS For 1" IPS For 1 1/4" IPS For 2" IPS Blanking Plates 3 1/2" [89mm] diameter top plate NOTE: B - Brass S - Stainless Steel 6

Multiplex Series Service Fitting Ordering Information Multiplex Selection and Ordering It is easy to design a unique Multiplex Service Fitting. Just follow these steps: 1. Determine what fitting will be mounted to (ie: Walkerduct Underfloor Duct, etc). 2. Determine size required based on single or dual service needed. For 8-Plex, select appropriate base style. 3. Select the required number of power, communication, A/V, or blank faceplates. Select two for 4-Plex and four for 8-Plex. 4. Select installation accessories. That s all! It s so easy! 4-Plex Single and 8-Plex Dual Service Fittings Ordering Information MP4 3" [76mm] Single service fitting includes housing, base, two mounting frames, and mounting hardware. For use on 2" [51mm] IPS underfloor duct systems. Can also be installed on single preset in Walkerduct Pro Series System. Has 1/2" and 3/4" trade size concentric conduit knockouts on each end. Overall capacity is 55.3 cu. in. [906 cu cm]. Fitting also provides 1" and 1 1/4" trade size concentric knockouts in baseplate. 6 3/4" [171mm] 4 3/4" [121mm] MP8 3" [76mm] 6 3/4" [171mm] 8 3/4" [222mm] Dual service fitting includes housing, base, two mounting frames, divider, and mounting hardware. For use on two No. 2 ducts or one No. 2 and one No. 4 duct. On Walkerduct Pro Series the fitting can be installed on any two-duct system. Has 1/2" and 3/4" trade size concentric conduit knockouts on each end. Overall capacity is 104.3 cu. in. [1709 cu cm]. Fitting also provides 1" and 1 1/4" trade size concentric knockouts and one 1" trade size knockout in baseplate. MP8-1 3" [76mm] Same as MP8, except mounts on PK and N-R-G Presets, one No. 2, or one No. 4 duct. On Walkerduct Pro Series the fitting can be installed on any two-duct system. Overall capacity is 104.3 cu. in. [1709 cu cm]. Has 1/2" and 3/4" trade size concentric knockouts on each end. Fitting also provides one 1" trade size knockout in baseplate. 6 3/4" [171mm] 8 3/4" [222mm] 1124-1 Locking Nipple For 1" [25mm] IPS insert opening. 1" [25mm] long. 1124L-1 Locking Nipple For 1" [25mm] IPS insert opening. 1 1/2" [38mm] long. Activation Accessories Ordering Information 1126A -1/4 [6.4mm] Adapter To change 2" [51mm] -3/4 [19mm] IPS preset to 1" [25mm]. -1 [25mm] Suffix denotes opening size. -1 1/2 [38mm] 1124F-1 Locking Nipple For 1" [25mm] IPS opening. 5/8" [15.9mm] long. For use on Flushduct Infloor Raceway. 455F-1 Outlet Flange For 1 5/8" [41mm] diameter opening. For use on Flushduct Infloor Raceway. 7

Multiplex Series Service Fitting Ordering Information Power Faceplates for Multiplex Service Fittings Ordering Information* M-DR Power Faceplate Single duplex opening. M-2GFI Power Faceplate Dual GFI opening. M-2DR Power Faceplate Dual duplex opening. M-DR/GFI Power Faceplate Single duplex and GFI openings. M-GFI Power Faceplate Single GFI opening. * All plates include mounting hardware. Plate dimensions are 3.365" [85.5mm] wide, x 2.98" [75.7mm] high, excluding flanges. Communication Faceplates for Multiplex Service Fittings Ordering Information* LTF48-RT Faceplate Single opening Accepts Ortronics MAB6TJ TracJack and MAB3S2 Series II adapters. LTF48-ACT Faceplate Single opening. Accepts the Activate CM-MAB adapter. LTF48-1 LTF48-2 Faceplate 1" [25mm] diameter bushed opening. Faceplate 2" [51mm] diameter bushed opening. LTF48-B Faceplate Blank. LTF48-MAAP** Faceplate Accepts four (4) Extron Electronics MAAP device plates. * All plates include mounting hardware. Plate dimensions are 3.365" [85.5mm] wide, x 2.98" [75.7mm] high, excluding flanges. ** Products are ETL Listed. ED763 R7 Updated May 2015 For latest specs visit www.legrand.us/wiremold Copyright 2015 Legrand All Rights Reserved 60 Woodlawn Street West Hartford, CT 06110 Phone: 1.877.BY.LEGRAND (295-3472) www.legrand.us/wiremold 570 Applewood Crescent Vaughan, Ontario L4K 4B4 Phone:905.738.9195