Temperature Transmitter ZTT series

Similar documents
SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Temperature measurement TMD 832 head transmitter

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Temperature transmitter itemp PCP DIN rail TMT 121

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Universal Intelligent 2-wire DIN Rail Transmitters

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

Temperature Transmitters TMT 136, TMT 137

Multifunction Intelligent 4-wire Isolated Signal Conditioner

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

HART Compatible Intelligent 2-wire DIN Rail Transmitters

HART Compatible Intelligent 2-wire In-head Transmitters

Temperature head transmitter itemp PCP TMT 181

Universal Intelligent 2-wire DIN Rail Transmitters

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Universal Intelligent 2-wire In-head Transmitters

itemp HART DIN rail TMT112

Temperature Transmitters - DIN Rail Mounted

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Temperature Transmitters - Head Mounted

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

FC-33, DC SELECTABLE SIGNAL CONDITIONER

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

P5201 Universal Programmable Transmitters with Galvanic Isolation

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

High-precision process calibrator Model CED7000

0 2 1 â Ó. itemp HART TMT182. Technical Information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

0 2 1 â Ó. itemp HART TMT182. Technical Information

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

S200 I/O System Units

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MEMOCAL 2000/2000S. Hand-held calibrator

4-20mA, 0-10V and general process measuring bargraph displays

Modular Smart Interfaces

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature head transmitter itemp PCP TMT 181

Excellent low-cost Process & Temperature Controllers

High Performance Process & Temperature Controllers

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Temperature transmitter with local display RIT 261

Temperature Measurement

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

2002 IS Catalog. Page

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

CALYS 100. Field precision documenting multifunction calibrator

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Process displays For standard signals, temperature, resistance measurement

Isolators A3/1.

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

CALYS 75. Field documenting multifunction calibrator

CALYS 150. Advanced documenting multifunction calibrator thermometer

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Additel 875 Series Dry Well Calibrators

Transmitter. Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter. Application Areas. Features and Benefits

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: W2TS. Mini-MW Series

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

itemp PA TMT184 Technical information

Temperature transmitter itemp RTD DIN rail TMT 127

2 WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. resistances. The RTD input may be with 2,3 or 4 wire connection.

ONE CALIBRATOR ONLY MAIN FEATURES:

Temperature head transmitter itemp TC TMT 188

SITRANS T measuring instruments for temperature

RTD/RES. Pot. Output type Min Max Min. span. Current 4 ma 20 ma 4 ma. Burn-out values Max. output value 21.8 ma Min. output value 2.

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

CALYS 150. Advanced documenting multifunction calibrator thermometer

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

Two-Wire Programmable Transmitter for:

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

CALYS 150. Advanced documenting multifunction calibrator thermometer

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Rail mounted Temperature Transmitter TH102/TH102-Ex

ADAM 4000/4100 Series

CALYS 50. Field multifunction calibrator for basic use

20 General technical data XI/ON

Hand-held temperature calibrator Model CEP3000

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

K3P ENG.qxd 23/10/ Pagina 1

Temperature Measurement

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

TxBlock-USB Transmitter

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

DRG-SC Series Signal Conditioners

CONTA-ELECTRONICS. Converter Units

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Installation and Operating Manual

Transcription:

BT.11.13 ZT/I ZTT series The ZTT series transmitter accepts the most commonly used temperature sensors (RTD, T/C) as well as mv and slide wire signals. All the models adopt a 2 wire 4...20mA output signal and can be supplied for head connection or top hat DIN rail mounting. The complete range provides from the analogue type with adjustable range to the SMART type with Quick selection via deep switches or PC programmable with a simple Software running on Windows 95. Several types can be provided with galvanic isolation and EEx for hazardous area The small dimensions grant a better use of the space in the cabinet. E ISO 9001 Certified

s ZTT series ZTT-10 2 or 3 wire Input Pt 100 T/C J, K, T Input User re-rangeable via links Low cost Head mounting ZTT-31 2 or 3 wire Input Pt 100 User selectable ranges 4...20mA output High performances Small size Top Hat DIN rail mounting ZTT-14 e ZTT-15 SMART Galvanically isolated Universal input (Pt100, TC, mv) High accuracy & thermal stability Quickly PC programmable Custom linearisation EEx version (ZTT-15) Head mounting ZTT-12 SMART 2 or 3 wire Input Pt 100 High accuracy & thermal stability Quick programmable Low cost Head mounting ZTT-33 SMART Galvanically isolated Universal input (Pt100, TC, mv) High performances Quickly switch & PC programmable Custom linearisation EEx version Small size Top Hat DIN rail mounting ZTT-32 Galvanically isolated TC J, K, N, R, S, T Input User selectable ranges High performances Small size Top Hat DIN rail mounting 2

Input RTD ZTT-10 Series ZTT-31 Series ZTT-32 Series Characteristics Description Spec.s @ 20 C Spec.s @ 20 C Spec.s @ 20 C Standard ranges SeeTable1 SeeTable1 SeeTable1 DIN43760 Custom [X] DIN43760 Custom [X] Output Approvals General Characteristics TC 4..20mA passive 2 wire EMC ±0.2 C ±0.2% of ±0.15 C ±% of see table 2 Burn-out Standard high range Excitation current 2 ma max Offset dependant Gain 25 C /500 C ZTT 10 K, T, J ZTT 32 J, K, N, R, S, T MilliVolt -50~50 mv Isolation Input/Output Offset Span Linear with signal (mv) ±0.1% FS plus cold junction error non-linearised ±100 C, solder link & potentiometer Linear with signal (mv) da 100 a 1000 C Impedance > 1 MΩ >1 MΩ Burn-out High range standard- Low range by link High range standard (Low range on request) Automatic for T/C and fixed zero compensation for mv or differential T/C measurement ±0.2 C@ 20 C ±0.05 C/ C typical 0.1% of output span max 30 ma max 30 ma max 30 ma Cold junction Automatic 0~70 C 0.2 C @20 C Total Protection Reverse connection protected BS EN 50081 Emissions BS EN 50082 Reverse connection and over voltage protected BS EN 50081 Emissions BS EN 50082 Reverse connection and over voltage protected BS EN 50081 Emissions BS EN 50082 Power Supply 10~30 Vcc 10~30 Vcc 10~30 Vcc Loop resistance 700Ω @ 24Vcc 700Ω @ 24Vcc 700Ω @ 24Vcc Stability 100 ppm/ C 2µVcc/ C Loop volts sensivity stability 10µA/V ZERO drift typ. 0.02%/ C SPAN drift typ. 0.005%/ C Response time (ripple) <40µA/V (1V ripple 50 Hz) (ripple) <40µA/V (1V ripple 50 Hz) 100 ms at 70% of final value 200 ms at 70% of final value Env.temperature 0~70 C 0~50 C 0~50 C Env. humidity 0~95% UR non condensing Characteristics 10~95% UR non condensing 10~95% UR non condensing Mounting Head connection Rail DIN EN 50022-35 Rail DIN EN 50022-35 Protection IP20 IP20 Dimensions ø 42 mm x 23 mm 12.5 x 75 x 67.5 mm 12.5 x 60 x 67.5 mm Table 1 Standard ranges C Used sensor ZTT 10 ZTT 31 ZTT 32-30 +35 RTD RTD -25 +75 RTD RTD 0 +50 RTD RTD 0 +100 RTD - TC K, T, J RTD TC N, K, T, J 0 +200 RTD - TC K, T, J RTD TC N, K, T, J 0 +400 RTD-TC K, T, J RTD TC N, K, T, J 0 +600 TC K TC N, K, J 0 +800 TC K TC N, K, J 0 +1000 TC K TC N, K, R, S 0 +1200 TC N, K, R, S 0 +1600 TC R, S 0 50mV Table 2 ZTT-31 % Reading 0.4 0.2 0.1 0.2 0.4 Temp. C -180-100 0 200 500 600 Overall Dimensions ZTT-10 ZTT-32 ZTT-31 Order Code 23 60 67.5 Example: ZTT-31 / GD / P / 0 200 33 2 holes ø5.5 mm 35 12.5 42 60 75 ZTT-10 / RD / Sensor / Lo - Hi ZTT-31 / GD / P / Lo - Hi ZTT-32 / GD / Sensor / Lo - Hi K T J L N R S Example: ZTT-32 / GD / K / 0 1200 RD P RTD (Pt100) CD K Cromel/Alumel T/C CD T Copper/Constantan T/C CD J Iron/Constantan T/C IEC CD L Iron/Constantan T/C DIN Example: ZTT-10 / RD / P / O 100 Cromel/Alumel T/C Copper/Constantan T/C Iron/Constantan T/C IEC Iron/Constantan T/C DIN Nicrosil/Nisil T/C Pt 13% Rh-Pt Pt 10% Rh-Pt 3

Characteristics Input and ranges Output Approvals General characteristics Comm.s Description RTD (Pt-100) TC mv Pt100 Ω a 0 C Thermal Drift Excitation current Max lead resistance Serie ZTT-12 SMART for RTD Spec.s @ 20 C @ 24Vdc EN60751 2 or 3 wire -200~850 C (18~390 Ω), minimum span 25 C DIN43760 Custom [X] ±0.01% span ±0.05% of zero 0.08 C/10 C, span 100 ppm/ C Characteristics Serie ZTT-14 & ZTT-15 SMART with galvanic isolation Spec.s @ 20 C EN60751 2 or wire -200~850 C (18~390 Ω), minimum span 25 C DIN43760 Custom [X] ±0.01% span ±0.05% of zero 0.08 C/10 C, span 100 ppm/ C 1 ma max. 300µA~550µA 50 Ω per leg drift 0.02 C/10ΩR 50 Ω per leg drift 0.02 C/10ΩR type K, J, T, R, S, E, F, N, [X] IEC 584-3 see table IEC 584-3 Cold junction compensation Thermal Drift ±0.04% full range input ±0.05% of or 0.5 C (max) (including effects of calibration, linearisation and repeatability) internal, error ±0.5 C, drift 0.5 C/10 C 40..+85 C zero 0.1µV/ C span 100ppm/ C -10~75 mv, min. 5 mv Characterisation Linear or custom ±10µV±0.07% of Input Impedance 10 MΩ Thermal Drift zero 1µV/10 C span 100ppm/ C 10~390 Ω, minimum span 5% Characterisation Linear or custom Potenziometro 0.1% of full range input Thermal Drift 100ppm/ C ±5µA ±5µA Power supply 4 20mA, influence 23 ma max 2 µa/10v 2 µa/10v a 2 fili Thermal Drift 10µA/10 C 10µA/10 C Power supply 10~35 Vcc 10~35 Vcc Maximum load 700Ω a 24Vcc 700Ω a 24Vcc Intrinsic safety EEx ia IIC T5 ZTT-15 Non Incendive ExNII Input/Output isolation 500 Vac 1 min Update tim 1 s at final value 250ms max. Sampling time <1s Warm-uptime Stability 2 min at the spec.s values 0.1% full range input or 0.1 C/year Filter factor Off, 2s, 10s, Adaptive Operating range -40~85 C -40~85 C Storage temperature -50~100 C -50~100 C EMC EN 50081 Emissions EN 50081 Emissions EN 50082 EN 50082 Humidity range 10~90% UR non 10~90% UR non condensing condensing Dimensions ø43 mm x 21 mm ø43 mm x 21 mm PC interface RS 232 by means adaptor Serial comm.s protocol ANSI X3.28 1976 Baudrate 1200 baud Max cable lenght 1000 m Minimum load of the line 100 Ω ZTT-14 & ZTT-15 - Standard ranges Sensor C Minimum span C RTD (Pt100) -200 850 25 K -200 1370 50 J -200 1200 50 T -210 400 25 R -10 1760 100 S -10 1760 100 E -200 1000 50 L -100 600 25 N -180 1300 50 [X] ±9999 Custom ZTT-14 & ZTT-15 - Block diagram A D C Dimensions 33 2 holes ø5.5 mm Order code ZTT-12 standard model ZTT-14 - RD / P / Programming Kit for ZTT12 including software interface, power supply unit and case ZTT-15 EEX ia IIC T5 version Galvanic isolation PSU -Main Comms DAC / RD / P / Lo - Hi AZTT-RCPW -KIT-EUR Programming Kit for ZTT14 and ZTT15 including software interface, power supply unit and case 43 Loop 21 V-- V+ Lo - Hi ZTT-14 - CD / K / Lo RTD standard model - Hi 4

Characteristics ZTT-33 Series SMART with galvanic isolation Characteristics Description Spec.s @ 20 C @ 24Vcc RTD (Pt-100) Excitation current Maximum lead resistanc Pt100 Ω a 0 C EN60751 2 or 3 wire -200~850 C (18~390Ω), minimum span 25 C DIN43760, CUSTOM [X] ±0.01% span ±0.05% of zero 0.08 C/10 C, span 100 ppm/ C 300µA~550µA 50Ω per leg, draft 0.02 C/10Ω R line K,J,T,R,S,E,F,N,[X] types IEC 584-3 see table IEC 584-3 Sensor C Minimum span C RTD (Pt100) -200 850 25 K -200 1370 50 J -200 1200 50 T -210 400 25 R -10 1760 100 S -10 1760 100 E -200 1000 50 L -100 600 25 N -180 1300 50 [X] ±9999 Custom Note: Quick standard ranges (57) selection my means 6 deep switches Input & ranges TC ±0.04% full range input, ±0.05% of or 0.5 C (max) (including the effects of calibration, linearisation and repeatability) ZTT-33 - Block diagram Output mv Potentiometer 4~20 ma (>3.8~<20.2mA) 23 ma max. Cold junction compensation Characterisation Input impedance internal, error±0.5 C, drift 0.5 C/10 C -40..+70 C zero 1µV/10 C span 100ppm/ C -10~75 mv, min. 5 mv Linear or custom (5th order polynomial) ±10µV±0.07%of 10 MΩ zero 1µV/10 C span 100ppm/ C 10~390Ω, min. span 5% Characterisation Protection Power supply influence Power supply Maximum load Linear or custom (5th order polynomial) 0.1% of span 100ppm/ C Reverse connection and over voltage protected ±5µA 2 µa/10v 10µA/10 C 10~35 Vcc 700Ω a 24Vcc Approvals Intrinsic safety EEx ia IIC T4, T5, T6 General characteristics Comm.s Input/Output isolation 500 Vac 1 min Updatetime 250ms max. Samplingtime <1s (63 % of final value) Warm-uptime 2 min at the spec.s values Stability 0.1% input range or 0.1 C/year Filter factor Off, 2s, 10s, Adaptive Operating range -10~70 C Storage time -40~70 C EMC Humidity range EN 50081-1 Emissions EN 50082-2 10~90% UR non condensing PC interface RS 232 via interface adapter Serial comm.sprotocol ANSI X3.28 1976 Baudrate 1200 baud Max cable lenght 1000 m Minimum loadoftheline 100~300Ω Conf. parameters Sensor, Burn-out, C/ F, Output, Filter, Tag, Offset A D C 0 1/on ZTT-33 - Wiring 1 2 3 4 5 6 7 8 9 10 Galvanic isolation ZTT-33 - Dimensions 99.0 Order Code ZTT-33 /GD standard model ZTT-33X/GD EEX ia IIC T5 version PSU -Main Deep switches 1 2 3 4 5 6 7 8 s selection Comms DAC Loop Burnout 0 = High Unit 0 = C nominal 24V Pt100 TC mv Potentiometer 99.5 18.25 AZTT-RCPW -KIT-EUR Programming Kit for ZTT33 including software interface, power supply unit and case V-- V+ 5

ASCON spa 20021 Bollate (Milano) Italy Via Falzarego, 9/11 Tel. +39 02 333 371 Fax +39 02 350 4243 http://www.ascon.it e-mail info@ascon.it Le informazioni del presente bollettino sono soggette a cambiamenti senza preavviso