PROBLEMS on Transformers

Similar documents
86 chapter 2 Transformers

148 Electric Machines

Code No: R Set No. 1

Hours / 100 Marks Seat No.

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Practical Transformer on Load

VALLIAMMAI ENGINEERING COLLEGE

EN Assignment No.1 - TRANSFORMERS

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Chapter 2-1 Transformers

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING

Chapter 2: Transformers

Transformer & Induction M/C

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

Code No: R Set No. 1

Module 7. Transformer. Version 2 EE IIT, Kharagpur

EQUIVALENT CIRCUIT OF A SINGLE-PHASE TRANSFORMER

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Open Circuit (OC) and Short Circuit (SC) Tests on Single Phase Transformer

CHAPTER 2. Transformers. Dr Gamal Sowilam

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

Cork Institute of Technology. Autumn 2008 Electrical Energy Systems (Time: 3 Hours)

SECTION 4 TRANSFORMERS. Yilu (Ellen) Liu. Associate Professor Electrical Engineering Department Virginia Tech University

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS)

APPENDIX 4 TYPICAL LAYOUT, VALUES AND CONSTANTS

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Reg. No. : BASIC ELECTRICAL TECHNOLOGY (ELE 101)

ECG 741 Power Distribution Transformers. Y. Baghzouz Spring 2014

1. (a) Determine the value of Resistance R and current in each branch when the total current taken by the curcuit in figure 1a is 6 Amps.

Spring 2000 EE361: MIDTERM EXAM 1

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

AUTO-TRANSFORMER. This is having only one winding; part of this winding is common to both primary and secondary.

Downloaded From All JNTU World

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS) Dundigal, Hyderabad

Transformers. gpmacademics.weebly.com

Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

ELECTRICAL ENGINEERING ESE TOPIC WISE OBJECTIVE SOLVED PAPER-II

AP Physics C. Alternating Current. Chapter Problems. Sources of Alternating EMF

WELCOME TO THE LECTURE

Table of Contents. Table of Figures. Table of Tables

BE Semester- VI (Electrical Engineering) Question Bank (E 605 ELECTRICAL POWER SYSTEM - II) Y - Y transformer : 300 MVA, 33Y / 220Y kv, X = 15 %

SYNCHRONOUS MACHINES

Rony Parvej s EEE. Lecture 3 & 4: Transformer. Update: 30 April, fecabook.com/ronyiut

Rarely used, problems with unbalanced loads.

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

Downloaded From JNTU World. B.Tech II Year II Semester (R09) Supplementary Examinations December/January 2014/2015 GENERATION OF ELECTRIC POWER

ECE 321 Experiment No: 4 Energy Systems Lab 1 Fall 2009 TRANSFORMERS-1

Look over Chapter 31 sections 1-4, 6, 8, 9, 10, 11 Examples 1-8. Look over Chapter 21 sections Examples PHYS 2212 PHYS 1112

TRANSFORMER THEORY. Mutual Induction

APPLICATION NOTE - 018

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (EE, EN, EC, CE)] QUIZ TEST-3 (Session: ) Time: 1 Hour ELECTRICAL ENGINEE

Module 7. Transformer. Version 2 EE IIT, Kharagpur

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

A Thyristor Controlled Three Winding Transformer as a Static Var Compensator

ELECTRICAL MEASUREMENTS

Electrical Machines I : Transformers

1. THREE-PHASE TRANSFORMER. SHORT CIRCUIT TEST

PART A. 1. List the types of DC Motors. Give any difference between them. BTL 1 Remembering

EE2003 Circuit Theory Chapter 13 Magnetically Coupled Circuits

EE2022 Electrical Energy Systems

Transformers. Dr. Gamal Sowilam

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ACADEMIC YEAR / EVEN SEMESTER QUESTION BANK

QUESTION BANK ETE (17331) CM/IF. Chapter1: DC Circuits

Operating principle of a transformer

R10. III B.Tech. II Semester Supplementary Examinations, January POWER SYSTEM ANALYSIS (Electrical and Electronics Engineering) Time: 3 Hours

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

PROBLEMS. Figure13.74 For Prob Figure13.72 For Prob Figure13.75 For Prob Figure13.73 For Prob Figure13.76 For Prob


Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Class XII Chapter 7 Alternating Current Physics

EE 221 Circuits II. Chapter 13 Magnetically Coupled Circuits

Engineering Science OUTCOME 4 - TUTORIAL 3 CONTENTS. 1. Transformers

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

VS JE _D Please read the instructions carefully before attending the Question paper. All Questions are compulsory.

MGVCL VSJE - Question Booklet Code "A"

Transformer Factory Testing

AEIJST - January Vol 5 - Issue 01 ISSN Minimization Iron Losses in Transformer

Dhanalakshmi Srinivasan Institute of Technology, Samayapuram, Trichy. Cycle 2 EE6512 Electrical Machines II Lab Manual

Three Winding Transformer.

RESONANT TRANSFORMER

Three-phase short-circuit current (Isc) calculation at any point within a LV installation using impedance method

REV NO EXPERIMENT NO 1 AIM: To perform open and short circuit tests on 1-phase transformer and to calculate efficiency. Apparatus required:

Transformers 21.1 INTRODUCTION 21.2 MUTUAL INDUCTANCE

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Exercises of resistors 1. Calculate the resistance of a 10 m long Copper wire with diameter d = 1.0 mm.

Copper and Electricity: Transformers and. the Grid. Transformers

Outcomes from this session

Regional Technical Seminar TAP CHANGERS

By Gill ( ) PDF created with FinePrint pdffactory trial version

Experiment No. Experiments for First Year Electrical Engg Lab

Protection of Electrical Networks. Christophe Prévé

Transcription:

PROBLEMS on Transformers (A) Simple Problems 1. A single-phase, 250-kVA, 11-kV/415-V, 50-Hz transformer has 80 turns on the secondary. Calculate (a) the approximate values of the primary and secondary currents, (b) the approximate number of primary turns, and (c) the maximum value of the flux. [Ans. : (a) 22.7 A, 602 A; (b) 2121; (c) 23.4 mwb] 2. The primary winding of a 50-Hz transformer has 480 turns and is fed from a 6400-V supply. Determine (a) the peak value of the flux in the core, and (b) the secondary voltage if the secondary winding has 20 turns. [Ans. : (a) 0.06 Wb; (b) 266.4 V] 3. A single phase, 50-Hz transformer has 80 turns on the primary winding and 400 turns on the secondary winding. The net cross-sectional area of the core is 200 cm 2. If the primary winding is connected to 240-V, 50-Hz supply, determine (a) the emf induced in the secondary winding, and (b) the maximum flux density in the core. [Ans. : (a) 1200 V; (b) 0.675 T] 4. A 10-kVA, single-phase transformer has its primary connected to a 2000-V supply. It has 60 turns on the secondary winding and voltage across it is found to be 240 V. Assuming the transformer to be ideal, calculate (a) the number of turns on its primary winding; (b) the full-load primary and secondary currents. [Ans. : (a) 500; (b) 5 A, 41.67 A] 5. A 200-kVA, 3300-V/240-V, 50-Hz, single-phase transformer has 80 turns on the secondary winding. Assuming an ideal transformer, calculate (a) primary and secondary currents on full load, (b) the maximum value of flux, and (c) the number of primary turns. [Ans. : (a) 60.6 A, 833.33 A; (b) 0.0135 Wb; (c) 1100] 6. A single-phase transformer with 10 : 1 turns-ratio and rated at 50 kva, 2400-V/240- V, 50-Hz is used to step down the voltage of a distribution system. The low tension (LT) voltage is to be kept constant at 240 V. Find the value of the load impedance of the LT side so that the transformer is loaded fully. Find also the value of the maximum flux inside the core if the LT side has 23 turns. [Ans. : 1.152 Ω, 0.047 Wb] 7. The primary of a single-phase transformer takes 1 A at power factor of 0.4 when connected to a 240-V, 50-Hz supply and the secondary is on open circuit. The number of turns on the primary is twice that on the secondary. A load taking 50 A at a lagging power factor of 0.8 is now connected across the secondary. What is now the value of the primary current? (Neglect the voltage drops in the transformer.) [Ans. : 25.9 A]

8. A single-phase, 50-Hz transformer has 100 turns on the primary winding and 400 turns on the secondary winding. The net cross-sectional area of the core is 250 cm 2. If the primary winding is connected to a 50-Hz, 230-V supply, calculate (a) the emf induced in the secondary winding, and (b) the maximum value of the flux density in the core. [Ans. : (a) 920 V; (b) 0.414 T] 9. The no-load current of a single-phase transformer is 5.0 A at 0.3 power factor when supplied from a 240-V, 50-Hz source. The number of turns on the primary is 200. Calculate (a) the maximum value of the flux in the core, (b) the core losses, and (c) the magnetizing current. [Ans. : (a) 5.4 mwb; (b) 360 W; (c) 4.77 A] 10. A transformer on no-load takes 1.5 A at a power factor of 0.2 lagging when its primary is connected to a 50-Hz, 230-V supply. Its transformation ratio (N 2 /N 1 ) is 1/3. Determine the primary current when the secondary is supplying a current of 300 A at a power factor of 0.8 lagging. Neglect the voltage drops in the windings. [Ans. : 14.5 A] 11. The no-load current of a 50-Hz, 230-V transformer is 4.5 A at a power factor of 0.25 lagging. The number of turns on the primary winding is 250. Calculate (a) the magnetizing current, (b) the core loss, and (c) the maximum value of the flux in the core. [Ans. : (a) 4.35 A; (b) 258.75 W; (c) 4.14 mwb] 12. A 100-kVA transformer has 400 turns on the primary and 80 turns on the secondary winding. The primary and secondary resistances are 0.3 Ω and 0.1 Ω, respectively. The primary and secondary leakage reactances are 1.1 Ω and 0.035 Ω, respectively. Calculate the equivalent impedance referred to the primary side. [Ans. : 3.426 Ω] 13. A single-phase, 100-kVA, 1100-V/220-V transformer has following parameters : R 1 = 0.1 Ω, X 1 = 0.3 Ω, R 2 = 0.004 Ω and X 2 = 0.012 Ω. Determine (a) the equivalent resistance and leakage reactance as referred to the high voltage winding, and (b) the equivalent resistance and leakage reactance as referred to the low voltage winding. [Ans. : (a) 0.2 Ω, 0.6 Ω; (b) 0.008 Ω, 0.024 Ω] 14. In a 50-kVA, 11-kV/400-V, single-phase transformer, the iron and copper losses are 500 W and 600 W, respectively under rated conditions. Calculate (a) the efficiency at unity power factor at full load, (b) the load for maximum efficiency, and (c) the iron and copper losses for this load. [Ans. : (a) 97.85 %; (b) 45.64 kva; (c) 500 W, 500 W] 15. A 10-kVA, 200-V/400-V, 50-Hz, single-phase transformer gave the following testresults : OC test (HV winding open) : 200 V, 1.3 A, 120 W. SC test (LV winding shorted) : 22 V, 30 A, 200 W.

Calculate (a) the magnetizing current, and (b) the equivalent resistance and leakage reactance as referred to the low voltage side. [Ans. : (a) 1.15 A; (b) 0.0555 Ω, 0.1745 Ω] (B) Tricky Problems 16. A single-phase, 50-Hz transformer has 30 turns on primary and 350 turns on secondary. The net cross-sectional area of the core is 250 cm 2. If the primary winding is connected to a 230-V, 50-Hz supply, calculate (a) peak value of the flux density in the core, (b) the voltage induced in the secondary winding, and (c) the primary current when the secondary current is 100 A. Neglect the losses. [Ans. : (a) 1.3814 T; (b) 2683.33 V; (c) 1166.67 A] 17. A single-phase, 50-Hz, 100-kVA, 2400-V/240-V transformer has no-load current of 0.64 A and core loss of 700 W, when its high voltage (HV) side is energized at rated voltage and frequency. Calculate the two components of the no-load current. If this transformer supplies a load current of 40 A at 0.8 lagging pf on its low voltage side, determine the primary current and its power factor. Ignore the resistance and leakage reactance drops. [Ans. : 0.5697 A, 0.2917 A; 4.584 A, 0.762 lagging] 18. An ideal 50-Hz, core-type transformer has 100 primary-turns and 200 secondaryturns. The primary rated voltage is 220 V. If the maximum permissible flux density is 1.2 T, what should be the cross-sectional area? Also, find (a) the secondary voltage, and (b) the primary current in complex form with reference to the secondary voltage vector when secondary delivers a current of 8 A at a lagging power factor of 0.8. 3 2 [Ans. : 8.26 10 m ;(a) 440 V; (b) 16 143.1 A ] 19. A 500-kVA, 11000-V/400-V, 50-Hz, single-phase transformer has 100 turns on the secondary winding. Calculate (a) the approximate number of turns on the primary winding, (b) the approximate values of the primary and secondary current, and (c) the maximum value of the flux in the core. [Ans. : (a) 2750; (b) 45.45 A, 1250 A; (c) 0.018 Wb] 20. A single-phase transformer has a turns-ratio of 144/432 and operates at a maximum flux of 7.5 mwb at 50 Hz. When working on no load, it takes 0.24 kva at a power factor of 0.26 lagging from the supply. If it supplies a load of 1.2 kva at a power factor of 0.8 lagging, determine (a) the magnetizing current, (b) the primary current, and (c) the primary power factor. [Ans. : (a) 0.97 A; (b) 5.8 A; (c) 0.731 lagging] 21. The primary and secondary windings of a 30-kVA, 6000-V/230-V, single-phase transformer have resistances of 10 Ω and 0.0016 Ω, respectively. The total reactance of the transformer as referred to the primary side is 23 Ω. Calculate the

percentage regulation of the transformer when supplying full-load current at a power factor of 0.8 lagging. [Ans. : 2.54 %] 22. A transformer with turns-ratio 8 : 1, has the resistances of the primary and secondary windings as 0.85 Ω and 0.012 Ω respectively, and the leakage reactances as 4.8 Ω and 0.07 Ω respectively. Determine the voltage to be applied to the primary to obtain a current of 150 A in the secondary when the secondary terminals are shortcircuited. Ignore the magnetizing current. [Ans. : 176.6 V] 23. A single-phase, 50-Hz transformer has a turns ratio 6 : 1. The primary and secondary winding resistances are 0.90 Ω and 0.03 Ω respectively, and leakage reactances are 5 Ω and 0.13 Ω respectively. Find (a) the voltage to be applied to the high voltage side to get a current of 100 A in the low voltage winding on shortcircuit, and (b) the primary power factor on short-circuit. Neglect the no-load current. [Ans. : (a) 164.67 V; (b) 0.2 lagging] 24. For the transformer in Prob. 26, assuming the power factor to be 0.8, find the output at which the efficiency is maximum and calculate its value. [Ans. : 447 kva, 98.4 %] (C) Challenging Prolems 25. A single-phase transformer has Z 1 = (1.4 + j5.2) Ω and Z 2 = (0.0117 + j0.0465) Ω. The input voltage is 6600 V and turns-ratio is 10.6 : 1. The secondary feeds a load which draws 300 A at 0.8 power factor lagging. Neglecting no-load current I 0, determine the secondary voltage and the output in kw. [Ans. : 600 V, 144 kw] 26. A single-phase, 10-kVA, 4000-V/400-V transformer has following parameters : R 1 = 13 Ω, X 1 = 20 Ω, R 2 = 0.15 Ω, X 2 = 0.25 Ω, R 0 = 12000 Ω and X 0 = 6000 Ω. Determine (a) the equivalent resistance and leakage reactance as referred to the primary winding, (b) the input current with secondary terminals open-circuited, and (c) the input current when the secondary supplies a load current of 25 A at a power of 0.8 lagging. [Ans. : (a) 28 Ω, 45 Ω; (b) 0.745 63.5 A ; (c) 3.18 42.9 A ] 27. A single-phase, 200-V/2000-V transformer is fed from a 200-V supply. The equivalent winding resistance and leakage reactance as referred to the low voltage side are 0.16 Ω and 0.7 Ω, respectively. The resistance representing core losses is 400 Ω and the magnetizing reactance is 231 Ω. A load impedance of Z L = (596 + j444) Ω is connected across the secondary terminals. Calculate (a) the input current, (b) the secondary terminal voltage, and (c) the primary power factor.

25.96 40.78 A ; (b) 1859 V; (c) 0.757 lagging] [Ans. : (a) 28. A single-phase, 100-kVA, 2000-V/200-V, 50-Hz transformer has impedance drop of 10 % and resistance drop of 5 %. (a) What is the regulation at full-load 0.8 power factor lagging? (b) At what power factor is the regulation zero? [Ans. : (a) 9.196 %; (b) 0.866 leading] 29. The primary and secondary windings of a 500-kVA, 11-kV/415-V, single-phase transformer have resistances of 0.42 Ω and 0.0019 Ω, respectively. Its core losses are 2.9 kw. Assuming the power factor to be 0.8, calculate its efficiency on (a) full load, and (b) half load. [Ans. : (a) 98.39 %; (b) 98.13 %] 30. A single phase transformer has percentage regulations of 4 and 4.4 for lagging power factors of 0.8 and 0.6, respectively. The full-load copper loss is equal to the iron loss. Calculate (a) the lagging power factor at which the full-load regulation is maximum, and (b) the full-load efficiency at unity power factor. [Ans. : (a) 0.4472 lagging; (b) 96.15 %] 31. A 250-kVA, single-phase transformer has an efficiency of 96 % on full load at 0.8 power factor lagging and on half load 0.8 power factor lagging. Find iron loss and full-load copper loss. [Ans. : 2.78 kw, 5.56 kw]