Medium voltage products. Field Application Support Analysis and calculations in Medium-Voltage electrical networks

Similar documents
Tab 2 Voltage Stresses Switching Transients

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

HIGH VOLTAGE CIRCUIT BREAKERS

TN, TT & IT Earthing Arrangements

IV/IV B.Tech (Regular) DEGREE EXAMINATION. Electrical &Electronics Engineering

TECHNICAL BULLETIN 004a Ferroresonance

LV/MV/HV CIRCUIT BREAKERS (SWITCH GEAR) DESIGN, INSPECTION, MAINTENANCE, REPAIR & TROUBLESHOOTING

Stabilized Differential Relay SPAD 346. Product Guide

Ferroresonance in MV Voltage Transformers: Pragmatic experimental approach towards investigation of risk and mitigating strategy

SHORT CIRCUIT ANALYSIS OF 220/132 KV SUBSTATION BY USING ETAP

Problems connected with Commissioning of Power Transformers

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Real Time Monitoring of SF6 Gas Pressure for Optimization Point on Wave Switching of SF6 Circuit Breaker

ABB Power Systems AB Sweden

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

P. Larivière, Hydro-Québec, D. Vinet, SNC-Lavalin Inc.

Ironing out resonance

DEPARTMENT OF EEE QUESTION BANK

ANALYSIS OF VOLTAGE TRANSIENTS IN A MEDIUM VOLTAGE SYSTEM

Module 2 : Current and Voltage Transformers. Lecture 8 : Introduction to VT. Objectives. 8.1 Voltage Transformers 8.1.1Role of Tuning Reactor

Do Capacitor Switching Transients Still Cause Problems?

Choosing the right Pico Technology active differential probe

THREE-PHASE SHORT-CIRCUIT TESTING OF HIGH-VOLTAGE CIRCUIT-BREAKERS USING SYNTHETIC CIRCUITS

Ferroresonances during Black Starts - Criterion for Feasibility of Scenarios

Sensor Technology. Applications for medium voltage

Thyristorised Automatic Power Factor

Transformer Engineering

FERRORESONANCE SIMULATION STUDIES USING EMTP

QUINT-PS/ 3AC/24DC/10

EE171. H.H. Sheikh Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Capacitive Voltage Substations Ferroresonance Prevention Using Power Electronic Devices

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Summary of the Impacts of Grounding on System Protection

Quality of supply management by means of interruption statistics and voltage quality measurements

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected.

Introduction to Harmonics and Power Quality

Bruce L. Graves /01/$ IEEE. IEEE Industry Applications Magazine PhotoDisc, Inc.

COOPERATIVE PATENT CLASSIFICATION

Transformer energisation after network blackout

HEC-45LTN-45PFAS Rev A

WDG 51 - Technical Data Sheet

I -limiter The world s fastest switching device

FACTORY AND FIELD VERIFICATION TESTS OF CONTROLLED SWITCHING SYSTEM

Protecting Large Machines for Arcing Faults

Electrical Engineering. Power Systems. Comprehensive Theory with Solved Examples and Practice Questions. Publications

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

VT guard Frequntly Asked Questions

Industrial Controls SIRIUS Controls

Smart Grid Where We Are Today?

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

WHITE PAPER. Medium Voltage On-Site Generation Overview. BY MIKE KIRCHNER Technical Support Manager at Generac Power Systems

KRF EMC Filters Installation, Operation and Maintenance Manual

Protective Relaying for DER

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

Evaluating the Response of Surge Arresters

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

Instrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications.

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

The Effect of Various Types of DG Interconnection Transformer on Ferroresonance

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

Mounting Instructions / Manual MV1171

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

DIFFERENCE BETWEEN SWITCHING OF MOTORS & GENERATORS WITH VACUUM TECHNOLOGY

System Protection and Control Subcommittee

SPAD 346 C Stabilized differential relay

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Voltage Relays. Ensuring Reliable Protection for Electrical Systems against Voltage Faults. ISO 9001:2008 Certified.

Distribution Transformer Random Transient Suppression using Diode Bridge T-type LC Reactor

Upgrading Your Electrical Distribution System To Resistance Grounding

Ferroresonance Signal Analysis with Wavelet Transform on 500 kv Transmission Lines Capacitive Voltage Transformers

Webinar: An Effective Arc Flash Safety Program

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

# - - Internal * On Line Examination

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

Power systems Protection course

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PROTECTION of electricity distribution networks

Modeling insulation in high-voltage substations

Protect and survive. Fault protection analysis in low-voltage DC microgrids with photovoltaic generators

Differential Protection with REF 542plus Feeder Terminal

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Active: Active probes achieve low input capacitance and high sensitivity by buffering and amplifying the signal close to the point of measurement.

Fuseless Capacitor Bank Protection

Industrial Electrician Level 3

PHYSICAL PHENOMENA EXISTING IN THE TURBOGENERATOR DURING FAULTY SYNCHRONIZATION WITH INVERSE PHASE SEQUENCE*

Demagnetization of Power Transformers Following a DC Resistance Testing

Power Quality and Reliablity Centre

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

Bus protection with a differential relay. When there is no fault, the algebraic sum of circuit currents is zero

Residual Current Operated Circuit-Breakers (RCCBs)

WDG 12 - Technical Data Sheet

Medium Voltage Products. KECA 80 C85 Indoor current sensor

HEC-100RTA-48QSCA Rev A1.0

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Impacts of the Renewable Energy Resources on the Power System Protection by: Brent M. Fedele, P.E., National Grid for: 11 th Annual CNY Engineering

Phase and neutral overcurrent protection

Fundamentals of Power Quality

Transcription:

Medium voltage products Field Application Support Analysis and calculations in Medium-Voltage electrical networks

Concept The electrical installation of an industrial site is a complex structure. Analyzing behavior in a transient condition allows optimum selection of the operation and protection devices in the installation design phase. Highlighting possible weaknesses and critical points in advance allows prevention of potential problems, damage to machinery, and costly periods of down time. Therefore, in order to completely satisfy the needs and expectations of the customer, an important role is played by analysis and consulting services offered thanks to the skill and experience of our qualified technicians. 2

The customer can maximize the economic return on their investment thanks to better knowledge of the system and by selecting the best installation solution. The solutions are documented in detailed reports that become part of the electrical installation s technical file. Simulations and accurate technical analyses performed with the most up-to-date modern calculation systems ensure the adequacy of the selected devices. 3

Services Choose ABB as partner in order to verify the behavior of electrical networks. A team of qualified technicians is able to provide a wide range of technical analyses and simulations, creating complex models of the customer s network, with the goal of identifying the most dangerous transient phenomena for the electrical installation. 40 [ka] 30 20 10 0-10 P75: fault in D current in cb. 2 generators The following services are offered: Short-circuit current calculation This analysis consists in the calculation of short-circuit current that occurs in the event of faults in various points of the installation. This allows the choice of appropriate circuit breakers, panel and other equipment, optimizing the solution in both technical and economic terms. -20-30 -40 0.00 0.03 0.06 0.09 0.12 [s] 0.15 c: A2 -A4 c: B2 -B4 c: C2 -C4 4

Optimum circuit breaker selection to protect generators The selection of a generator circuit breaker is a very delicate choice and requires careful analysis over time of the shortcircuit currents and their asymmetry thanks to physicalmathematical models of the circuit breaker, the generator itself and the installation. Strong asymmetries may lead to the current zero-missing phenomena, a lack of current zeros for a number of cycles. Opening in these conditions places the circuit breakers and the plant under stress with consequences for the set-up of the protection relays. Analysis allows optimum circuit-breaker selection and indicates the required measures that should be taken for the protection and good operation of the plant. Calculation of transient overcurrent due to insertion of capacitor banks The purpose of this analysis is to calculate current transients that occur during insertion of a capacitor bank, with or without another charged in back-toback mode. The criteria to be followed in order to contain the maximum value of the transient current are also proposed, as well as offering advice on selecting suitable apparatus to turn the capacitor bank on and off e.g. using synchronous switches that eliminate the transients, or circuit breakers which are suitable and approved for operating this type of load. Calculation of power-transformer inrush transients The purpose of this calculation is to check the behavior of the installation during commissioning. Certain phenomena, such as closing on off-load transformers, can in fact cause stress to the transformer itself and other components of the installation. Through a detailed and accurate electromagnetic model of the machine, it is possible to assess the behavior of the magnetizing current and suggest the most suitable actions to minimize effects on the plant. Calculation of transient overcurrent due to insertion of filter banks The filter bank is an extremely delicate element, where the presence of current harmonics must be appropriately considered during the operation phase of the bank itself. The purpose of analysis is to model the installation and the circuit breaker in order to select the most suitable apparatus for this application, assessing the relative switching transients. 5

Services Calculation and analysis of the Transient Recovery Voltage The purpose of this analysis is to check the recovery voltage trend over time after the circuit breaker opening phase in order to assess the possibility of restrike and to suggest optimum selection of the circuit breaker itself suggesting solutions to avoid exceeding this value. Critical motor start-up current calculation This analysis aims to assess the starting transient of electrical motors, with critical dimensions and parameters, in terms of effects on the plant during the start-up phase and its effect on the voltage drops. Where necessary, power factor correction systems are proposed which are designed ad hoc for the purpose of optimizing use also from an economic point of view. Ferroresonance calculations Particular installation conditions and particular operation sequences can lead to phenomena known as ferroresonance. These phenomena cause damage in power and instrument transformers that can be very serious and require their replacement. Analysis, through electromagnetic modeling of the machine and the installation conditions allows identification of the limits and values and evaluation of countermeasures in order to prevent down time. Calculation of switching overvoltage and suppression methods Switching operations of highly inductive loads must be carefully studied. Overvoltages that may be generated are sometimes very high and can damage the insulation on the plant s components such as power transformers, motors or even worse, generators. Analysis checks these phenomena, proposing appropriate solutions if necessary. Network Analysis The purpose of this study is to conduct a general analysis on the fault conditions that may occur in the system, identifying the critical points to be checked based on skills and experience acquired by our technicians over many years through numerous analyses conducted on various types of electrical installations. 6

The unavailability of an electrical installation is often more than a simple glitch. Knowing the limits and critical points ahead of time and making the right choices in selecting the protection components can be a determining factor. 7

Contacts ABB S.p.A. Power Products Division Unità Operativa Sace-MV Via Friuli, 4 I-24044 Dalmine Telefono: +39 035 6952 111 Fax: +39 035 6952 874 e-mail: info.mv@it.abb.com www.abb.com Data and images are not binding. Depending on technical development and products, we reserve the right to modify the content of this document without notice.. Copyright 2015 ABB. All rights reserved. 1VCP000576 - Rev. -, en - Brochure - 2015.03 - (Brochure Field Application Support) (gs)