Transport Canada Standard for LED Signal Modules at Highway/Railway Grade Crossings. TC E-14 (October 10, 2003)

Similar documents
Standard for LED Signal Modules at Highway-Railway Grade Crossings

daylight Spring 2014 College of Architecture, Texas Tech University 1

Lighting Terminologies Introduction

SPECIAL SPECIFICATION Inch LED Traffic Signal Lamp Unit

Photometry for Traffic Engineers...

Photometry for Traffic Engineers...

APPENDIX GLOSSARY OF TERMS

Lumen lm 1 lm= 1cd 1sr The luminous flux emitted into unit solid angle (1 sr) by an isotropic point source having a luminous intensity of 1 candela

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Light-Emitting Diodes

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Radiometric and Photometric Measurements with TAOS PhotoSensors

Basic lighting quantities

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Electrical Illumination and Design

Technical requirements. for solid-state lighting products (2010)

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

L E D L i g h t i n g G u i d e

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Electrical Installation LectureNo.10 Dr.Mohammed Tawfeeq Al-Zuhairi. Luminous flux Luminous intensity Illuminance Luminance

True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

07-Lighting Concepts. EE570 Energy Utilization & Conservation Professor Henry Louie

Basic Lighting Design Seminar

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

Solid-State Lighting Photometry Issues

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LED14.5WPAR30S/FL/827-DIM

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

Cat# LED Wall-PACK

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Indoor/ outdoor projector MINI-PROJECTOR-02 3LED RECESSED Ufo-02

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

Radiometry vs. Photometry. Radiometric and photometric units

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

12/02/2017. From light to colour spaces. Electromagnetic spectrum. Colour. Correlated colour temperature. Black body radiation.

Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined)

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

Eternal Shine Technology Co.,Ltd. EST

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

CHAPTER VII ELECTRIC LIGHTING

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

NVLAP LAB CODE:

NVLAP LAB CODE:

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

Report No.: EASZE Page 2 of 14

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

Physics of Light. Light: electromagnetic radiation that can produce a visual sensation.

Sometimes the axis of the I-U-dependence are shown in reverse order. In this case the graph shows the stabilized current and measured voltage.

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

Symbols and Terminology

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

1.2.2 All LED Traffic Signal Modules shall be produced in a NAFTA participating country.

Morris Products 53 Carey Road, Queensbury, NY 12804

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

INDEPENDENT TEST LABORATORY REPORT No

Photometric Test Report

Cat# LED Classic Large Wall-Pack

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

NVLAP LAB CODE:


LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

REVOLUTION LIGHTING TECHNOLOGIES INC

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

Light calculation example

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

It is important to use the right ballast to ensure the luminaire also ignites at low temperatures.

Dimming: PWM/TIME/0-5V/0-10V. RoHS

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

RoHS QPL ID # PLC6V1PABNUJS

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

Photometric Test Report

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

Transcription:

Transport Canada Standard for LED Signal Modules at Highway/Railway Grade Crossings TC E-14 (October 10, 2003)

- 2 - PURPOSE The purpose of this standard is to provide the minimum performance requirements for 200 mm and 300 mm Light Emitting Diode (LED) signal modules for use in highway/railway grade crossing signal assemblies in Canada. DEFINITIONS Burn-In Process The procedure by which a LED signal module is energized at an ambient temperature for a specified time duration to cause any early electronic component mortality failures to occur and to detect any component reliability problems before the product is shipped to the end user for installation. Candela (cd) SI unit of luminous intensity. The candela is the luminous intensity, in a given direction, of a source that emits monochromatic radiation of frequency 540 nm and that has a radiant intensity in that direction of 1/683 W per steradian (1 cd = 1 lm/sr). Chromaticity The colour of the light emitted by an LED signal module, specified as x-y or x and y chromaticity coordinates on the chromaticity diagram according to the 1931 Commission Inernationale d Eclairage (CIE) standard observer and coordination system. Duty Cycle The amount of time during a given unit of time that an LED signal module is actually energized, expressed as a percentage (i.e., 30 minutes per hour would be a 50% duty cycle). Illuminance (at a point on a surface) The luminous flux d v incident on an element of the surface containing the point divided by the area da of that element (footcandle, lux) LED Light Source A single light emitting diode (LED) or an array of LEDs.

- 3 - LED Signal Module An array of LEDs and a lens that together are capable of providing a circular signal indication. An LED signal module shall be capable of replacing the optical unit of an existing highway/railway grade crossing signal section. Light Stabilization Procedure The procedure by which an LED signal module is energized at a given temperature for a specified time duration to cause stabilization in light output. Long Term Luminous Intensity Degradation The reduction in luminous intensity that normally occurs when an LED is illuminated over an extended period of time. Lumen (lm) SI unit of luminous flux. Luminous flux emitted in unit solid angle [steradian (sr)] by a uniform point source having a luminous intensity of 1 candela (1 lm = 1 cd x 1 sr). Luminance (in a given direction, at a given point on a real or imaginary surface, Lv) Quantity defined by the formula where d v is the luminous flux transmitted by an elementary beam passing through the given point and propagating in the solid angle d containing the given direction; da is the area of a section of that beam containing the given point; is the angle between the normal to that section and the direction of the beam (footlambert, cd/m 2 ) Luminous Efficacy of Radiation (K) The luminous flux v divided by the corresponding radiant flux e (K = v/ e).

- 4 - Luminous Efficacy of a Source The luminous flux emitted divided by the power consumed by the source. Luminous Intensity (of a source in a given direction, Iv) The luminous flux d v leaving the source and propagating in the element of solid angle d containing the given direction, divided by the element of solid angle (Iv = d v/d candela) Luminous Flux ( v) Quantity derived from radiant flux e by evaluating the radiation according to its action upon the CIE standard photometric observer (lumen) Lux (lx) SI unit of illuminance. Illuminance produced on a surface of area 1 square metre by a luminous flux of 1 lumen uniformly distributed over that surface (1 lx = 1 lm/m 2 ) Power Consumption The electrical power in watts consumed by an LED signal module when operated at nominal operating voltage and ambient operating temperature range. Radiant Flux ( e) The total power emitted, received, or passing in the form of electromagnetic radiation. It is measured in watts. Rated Life The arithmetic average of burning hours for a sample number of signal modules operated at rated voltage and under defined operating conditions. Rated Voltage The nominal or design operating voltage of the LED signal module; the voltage at which rated watts, candelas, and life are determined.

- 5 - Rated Watts The average initial power (watts) consumed when the lamp is operated at rated voltage. Highway/Railway Grade Crossing Signal That part of a Highway/Railway Grade Crossing Warning System used at the crossing to provide visual warning to highway traffic. Spectral Luminous Efficiency Ratio of the radiant flux at wavelength m to that at wavelength such that both radiations produce equally intense luminous sensations under specified photometric conditions and m is chosen so that the maximum value of this ratio is equal to 1. PHOTOMETRIC REQUIREMENTS Luminous Intensity When LED signal modules are in use at a highway/railway grade crossing, they shall at all times and under all normal operational conditions meet the minimum luminous intensity values shown in Table A-1. Table A-1 - Minimum Luminous Intensity (Candela) over Temperature and Lifetime 0º 5º L/R 10º L/R 15º L/R 20º L/R 25º L/R 30º L/R 0º 400 375 250 150 75 40 15 5º D 350 325 250 150 75 40 15 10º D 130 125 110 85 60 35 15 15º D 45 40 35 30 25 20 15 20º D 15 15 15 15 15 15 10 Chromaticity A signal module shall produce a uniform red light output that conforms to the Equipment and Material Standards of the Institute of Transportation Engineers (ITE), Chapter 2, Section 8.04, 1998.

- 6 - Uniformity The ratio of the greatest and least luminance on the signal module shall not exceed 5:1, when measured over average areas of 500 mm 2. Rise/Fall Time The maximum rise time from zero intensity to full intensity, and the maximum fall time from full intensity to zero intensity, shall be 75 ms. PHYSICAL AND MECHANICAL REQUIREMENTS LED Signal Module Design The LED signal module shall be designed to replace the existing signal module holder, reflector, and lens in highway/railway grade crossing signal housings without requiring modification of the mechanical, structural, or electrical components of those housings, which are described in AREMA C&S Manual Part 3.2.35 (Recommended Design Criteria for Electric Light Unit for Highway-Rail Grade Crossing Signals Including Light Emitting Arrays and Incandescent Lamps). The LED signal module may be either 200 mm or 300 mm in size, and may have either a clear or a red lens. Any gasket or similar sealing provisions shall be made of a material in accordance with AREMA Manual Part 15.2.10 (Recommended Functional Guidelines for Gasket Material Suitable for Circuit Controllers, Signal Cases and Other Signal Apparatus Housings). Environmental Requirements The LED signal module shall operate over an ambient temperature range of -40 C (- 40 F) to 70 C (158 F) per MIL-STD-883, Test Method 1010. The LED signal module shall be protected against dust and moisture intrusion as per the requirements of NEMA Standard 250-1991, sections 4.7.2.1 and 4.7.3.2, for Type 4 enclosures. The LED signal module shall meet mechanical vibration and shock requirements as per AREMA Manual Part 11.5.1 (Recommended Environmental Requirements for Electrical and Electronic Railroad Signal System Equipment). The LED signal module lens shall be UV stabilized.

- 7 - Identification The LED signal module shall be clearly identified with the following information: Highway/Railway Grade Crossing: LED, Red Beam Deflection Classification: Universal Operating Voltage: Current Consumption at Operating Voltage: Meets Transport Canada Specifications: 2002 Serial Number: Date of Manufacture: If the module or its components require orientation, they shall be prominently and permanently marked with an indexing arrow. ELECTRICAL REQUIREMENTS Transient Voltage Protection LED signal module circuitry shall include voltage surge protection as specified in AREMA Manual Part 11.3.3 (Recommended Design Criteria for Surge Withstand Capability of Electronic Signal Equipment for Signal Systems). LED Drive Circuitry LED signal module circuitry shall operate in accordance with AREMA C&S Manual, Part 3.2.35 (Recommended Design Criteria for Electric Light Unit for Highway-Rail Grade Crossing Signals Including Light Emitting Arrays and Incandescent Lamps). Dielectric and Electromagnetic Interference LED signal module circuitry shall conform to dielectric and electromagnetic interference requirements for Class B equipment in AREMA Manual Part 11.5.1 (Recommended Environmental Requirements for Electrical and Electronic Railroad Signal System Equipment).