Guide to Confocal 5. Starting session

Similar documents
Leica SP8 TCS Users Manual

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

Things to check before start-up.

LSM 780 Confocal Microscope Standard Operation Protocol

LEICA TCS SP5 AOBS TANDEM USER MANUAL

Quick Start Guide. Leica SP5 X

Leica SPEII confocal microscope. Short Manual

LSM 710 Confocal Microscope Standard Operation Protocol

Leica SP8 TCS Users Manual

Zeiss LSM 880 Protocol

Title: Leica SP5 Confocal User Manual

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

LSM 800 Confocal Microscope Standard Operation Protocol

Widefield 1. Switching on

Cell Biology and Bioimaging Core

Confocal imaging on the Leica TCS SP8. 1) Turn the system on. 2) Use TCS user account. 3) Start LAS X software:

Zeiss LSM 780 Protocol

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

Leica Sp5 II Confocal User Guide

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Zeiss 880 Training Notes Zen 2.3

Leica TCS SP8 Quick Start Guide

Using the Nikon TE2000 Inverted Microscope

Zeiss 780 Training Notes

LSM 510 Training Notes

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol

MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL

Nikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope

LSM 510 Meta Training Notes

Nikon AZ100. Laser Scanning Macro Confocal Microscope. Jordan Briscoe Adam Fries Kyle Marchuk Kaitlin Corbin. May 2017.

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide

Leica TCS SL Confocal Training. Neuroscience Imaging Core Staff. Core Director. Facility Manager

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Zeiss Axio Imager.A1 manual

ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

b. Turn the power switch and key to on position for blue laser.

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Simplified Instructions: Olympus Widefield Microscope S1230

Olympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

TRAINING MANUAL. Olympus FV1000

Microscopy from Carl Zeiss

Title: Nikon A1R Confocal User Manual

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL

Nikon E800 Microscope. Operating Instructions

Leica SP8 Resonant Confocal. Quick-Start Guide

Nikon E800 Operating Instructions.

ZEISS LSM510META confocal manual

Leica TCS SP8 Quick Start Guide

Operating Instructions for Zeiss LSM 510

Brief manual how to start and close the Leica sp2 Confocal. (TCS SP2 AOBS system mounted on a DM IRE2)

REMEMBER: You have 5GB of disk space on this microscope. Check before you start if you have room for your experiment. If not delete your old data.

DIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands

Zeiss LSM 510 Multiphoton Confocal Microscope

Leica Confocal - 2. Instructions for Leica SP2 Confocal Equipped with Visible Laser Lines

Nikon SIM-E & A1-R System

Zeiss LSM 510 Multiphoton Confocal Microscope

Instructions for the Leica SP5 II laser scanning confocal microscope

DIC Imaging using Laser Scanning Microscopes (LSM) on Inverted Stands

Zeiss AxioImager.Z2 Brightfield Protocol

Axioscan - Startup. 1. Turn on the Axioscan (button to the left) and turn on the computer. 2. Log on and start the ZEN Blue software from the desktop

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide

OPERATING INSTRUCTIONS

3. are adherent cells (ie. cells in suspension are too far away from the coverslip)

Nikon E800 Operating Instructions.

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

QUICKSTART GUIDE: WIDEFIELD WF3 Zeiss Cell Observer Live Cell Imaging System (SAF, ROOM 409) Imperial College London

User Guide to the IBIF Leica TCS SP8 MP Confocal Microscope

Everest System / Slidebook Operating Procedures

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Olympus IX71 Microscope and DP71 Camera Instructions

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

Zeiss Axiovert 135 Fluorescence Microscope Quick Guide / Operations Manual (v. 1.0 February 09)

Characterization Microscope Nikon LV150

Diskovery Spinning Disk Guide

CONFOCAL MICROSCOPE (Zeiss LSM 510 META v4.2)

Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software

Nikon TE300 Eclipse Wide-Field Microscope

Contents. Introduction

CMI STANDARD OPERATING PROCEDURE. Fluoview 300 laser scanning confocal microscope

ZEISS LSM 710 NLO Multiphoton microscope Manual/Quick guide

Training Guide for Carl Zeiss LSM 880 with AiryScan FAST

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

Nasmyth Ultraview Vox User Protocol

The Leica Confocal Microscope System B46 Weill Hall (revised 4/01/10)

QUICKSTART GUIDE: WIDEFIELD HWF1 Zeiss Cell Observer Live Cell Imaging System (HAMMERSMITH, L BLOCK, ROOM 314) Imperial College London

Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope

Microscope Confocal Sp2 Upright.

Microscopy Suite. The Multi-Photon Confocal Microscope. Instructions for Leica SP2 Microscope #1 By Jon Ekman & Karl Garsha. Start-up.

Nikon A1Rsi Confocal Start-Up Sequence

personal DELTAVISION (pdv)

Microscope Confocal LSM510 META

Leica TCS SP2 User Manual 1.1. Markus Friedrich and James Lee. Department of Biological Sciences Wayne State University

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Usermanual for Leica SP8 confocal

Use of the HSW5 Spinning Disk Confocal Microscope Updated last May 25, 2010 OK

Transcription:

Guide to Confocal 5 Remember that when booking and before starting session you can check for any problems at https://www.bris.ac.uk/biochemistry/uobonly/cif/index.html Starting session Switch on microscope box under the table Switch on fluorescent lamp check that power is on 1st notch (at least) Box to the right of monitors: switch on scan electronics button, fan and turn key to vertical position. The PC is always left on. Heater Microscope power Fluorescent lamp

Using the microscope Very Important to avoid scratching lenses on the stage when changing lens position, lower the lenses down to bottom with the focus knob before turning the turret. Alternatively you can change the lens through the software which will lower and change the lens position for you Switch to brightfield. Press again for Phase Contrast then DIC. Switch to fluorescence Toggles between fluorescent filter cubes Adjust field diaphram of brightfield lamp Change intensity of fluorescence or brightfield lamp depending on what mode is in use Adjust field diaphram of fluo lamp Toggles between microscope and scan Toggles between Fluorescence And brighfield modes FITC filter cube TRITC filter cube Shutter DAPi filter cube

Fluorescent lamp igniter Power dial Move stage in X direction Move stage in Y direction Select fine XY control Focus Dial (behind) Select fine focus Select coarse focus Select coarse XY control Notes on using the microscope The stage of the microscope is fitted with a universal specimen holder adjust the sliders (gently) to the appropriate width. The 63x lens has an adjustable aperture on its collar. It s generally best to have this fully open (turned clockwise). Clean oil lenses with lens tissue before you start, then apply a small drop of immersion oil, preferably to coverslip than to lens to avoid over-doing it. If looking at microscope slides, invert the slide so the coverslip is on the underside. If using an oil lens, bring lens up until the lens touches oil (or oil touches coverslip if oil on lens). Get desired cells in focus and in the middle of the field of view before scanning. Avoid exposing your cells unnecessarily to fluorescent light (close shutter asap). Photodamage can also be reduced by reducing lamp intensity. Fluorescent lamp intensity can be increased if fluorescence is weak using the dial on the lamp igniter box. Heating control cube next to microscope. Controls on front can change desired temperature within plastic box. Heater should be switched on at least an hour (preferably much more) before experiment to allow temperature to stabilize.

Leica LAS AF software Double click Leica LAS AF icon on desktop to start. When prompted to initialize stage, click no (unless you re doing automated multi-position imaging) Once software is started, go to configuration, then lasers. Ignite the lasers you need by ticking the boxes. Note that the Argon laser (488 & 458/476/514nm) should be ignited at zero power and is then generally set to 20%. To switch on/off lasers, go to Configuration and select lasers Tick the boxes of the lasers that you need The argon laser should be switched on at zero power.

General software interface Fig. 1 View experiment folder Selecting a flurophore from Select method AOTF sliders control the list to brings up an emission spectra for reference only. LED indicates that laser is active % transmission of lasers Activates sequential scan setup Change Scan mode General scan settings Click here to select desired lens Tick box if capturing brightfield images To scan sample continuously whilst setting PMT gains, laser power, focus etc Fluorescence PMTs Brightfield PMT To capture series of Images (in Z, T or λ)

Basic image set up and capture Ensure the top of the microscope is in the upright position (90 vertical). In the software, select a method from list by double clicking Check general scan settings: Scan mode (default is xyz), image format (default is 512x512), scan speed (default is 400hz) Usually advantageous to tick [Bidirectional X] which doubles scan speed. (default position is 35.22 and should not be altered) Click [LIVE] sample is scanned continuously allowing you to see the changes to the image as you adjust the following main controls: Z position (focus) dial PMT gain (max 1250v, ideally <900v to reduce noise values given on display above Smart Gain dial) Laser power (using AOTF sliders and for the 488 laser the power slider in the laser configuration window) Zoom (type value required, move slider or tick [Zoom in], select rectangle tool and draw box on image) Adjust these controls quickly to reduce sample fading and then click [STOP] Select number of averages typically 3-4. (NB select either line or frame average the result will be the same for stationary cells but line averaging (or no averaging) preferable for most live cell imaging). Click [Capture Image] to capture single image. Notes Increase format (> 512x512) and/or zoom to optimise XY sampling (pixels 70-100nm, no point going smaller) for best resolution. You can decrease the Smart offset to make the background blacker. If required use carefully as negative offset may subtract real signal as well as the background. Pinhole should normally be left at its optimum size (1 Airy unit) but can be increased (e.g. to 2-3) to increase signal (with small loss of z-resolution). Use [QLUT] next to image window to help judge optimum brightness pixels will turn blue on saturation and green at zero. The standard beam path methods may not be ideal for your sample Double click the PMT slider to specify the emission wavelengths that you want to detect (emission range should start at least 10nm higher than the excitation wavelength). If you have more than 1 fluorophore it s usually advisable to use the sequential scanning mode (see next page) Smart Gain Smart offset Field Rotation Pinhole Soft Zoom Z position

Sequential Scanning set up for multi channel imaging 1) Click [seq] button and the sequential scan setup window will appear 2) Scan 1 is highlighted. Define settings for your 1 st fluorophore (which laser is active, which PMT is active and the emission wavelengths you want to detect). These settings will be saved inside scan 1. 3) Click on the + sign and scan 2 will appear and will be highlighted. Define settings for your 2 nd fluorophore (note you must use a different PMT for each fluorophore if between lines selected the fastest option). 4) Click + again and repeat if you have 3 or more fluorophores. 5) You can save these settings and then load them up next time by clicking [save] 6) Click [Live]. The software will scan your sample sequentially, switching between your scan channels after every line in your image allowing you to view and optimize all the channels at the same time: In your image window, click on the channel you want to adjust. The smart gain and smart offset dials will make their adjustments on the channel selected. To alter the laser power for a channel, 1 st click on the channel in the sequential scan window, then change the power using the slider (don t change a laser power before selecting the appropriate channel) 7) When all the channels are set up, stop the live scan then click [Start] to capture your images. Notes Remember to select a method (scan 1, scan 2 etc..) before altering the laser power for that method. If using the 405 laser for one of your channels, turn the laser power down to 0 for other channels but leave the laser on (so that the LED is still on [see Fig 1] ) The maximum number of fluorescent channels that can be captured using the between lines mode is 3. If more are required, select between frames sequential mode. Here you view 1 channel at a time whilst adjusting the settings with the [live] scan. Click [start] to capture all the channels.

Setting up a Z-stack 1) Open up Z-stack window by clicking arrow top right 2) Set upper and lower limits of the z position for your sample: Click [Live] and adjust the z position dial until you reach one extreme. Click [Begin]. The computer records this position and highlights the starting point. Then focus through in the other direction until the other extreme. Click [end]. Then click [Stop] 3) Define the size (better standardisation between stacks) or number of steps you want to take. Note that the system optimised value is the optimum step size to maximise Z-resolution with lens you are using this is likely to be OTT for most applications except for best quality 3D data. Step size 0.5-1.0 micron more commonly used, depending on data required and depth of specimen. 4) Click [Start] to capture the stack Notes Photobleaching is more likely to occur when capturing large stacks of data compared with single images. If this is a problem, try: Using a lower laser power and higher gain Taking fewer sections Using fewer averages As a rough guide, to get a decent set of data for 3D reconstruction, you typically need at least 20 sections and 0.5 micron steps or less for relatively thin samples. Brightness levels of your fluorophore may be different at different Z positions. When adjusting laser powers and gains, bear this in mind a good setting at one z position may oversaturate the PMT at another.

Timecourses 1. Select the appropriate acquisition mode from the drop down list XYT for capturing images at a single plane of focus over time. XYZT for capturing a z-stack over time 2. A new dialogue box appears in which you can define the timecourse o o o Time interval time between timepoints Ticking [Minimize] will give the minimum time interval at the current settings taking into account the scan speed, scan resolution, number of averages etc Number of frames or duration of experiment or whether to continue until stopped 3. Click [Apply] 4. In the XY dialogue box set the number of averages (best to use Line averages with live cells) 5. Click [Start] to begin capturing timecourse Notes Generally use a lower laser power, less averaging and consider opening pinhole for live cell imaging to limit photo-damage. To increase the speed of acquisition you can alter these settings in the XY dialogue box: o Bidirectional scanning (doubles speed. No effect on image quality). o Use less averages. o Change resolution (e.g. 512 x 256 pixel resolution will double speed). o Change scan speed (faster speeds will decrease quality). Multi stage timecourses can be set up using the FRAP wizard. FRAP and FRET wizards are available from a drop down menu. Use the Environmental chamber heater if you want your experiments to run at 37C the heater should be switched on at least 1 hour (preferably much longer) prior to use to allow the system to stabilize temperature.

Transmitted light images You can capture transmitted light images (brightfield, phase contrast or DIC) simultaneously as you capture fluorescence images. Often the microscope will be already set up correctly but if in doubt follow these steps: 1) Check that the microscope is set up correctly for viewing transmitted light. Get your sample into focus Push the top button behind the focus wheel on the left to view sample with brightfield. Push button again to go to phase contrast mode, again to go to DIC mode. Note that the current mode will be displayed on the front display on the microscope and if the mode is not possible with the current lens the the display will flash. Note that: 63x lenses can do DIC but can t do phase contrast 40x lens can t do DIC but can do phase contrast. 20x and 10x can only do brightfield Check aperture diaphragm is open (above 10 on display) using AP buttons on left side Check the condenser position is correct: Fully close field diaphragm (see figure), look down eyepieces and adjust height of the condenser until octagon of light comes into sharp focus. Center the light if necessary using the pull out screw adjusters (don t use these until you can see the outline of the octagon). Open field diaphragm 2) Set up the software for capturing transmitted light images by adjusting one of your fluorescence methods so that transmitted light images will be captured simultaneously using laser light. Activate the tick box additional channels Tick the box for PMT Trans and select the appropriate mode (BF, Phase contrast, DIC) Scan sample. Increase gain and decrease the offset to increase image contrast Adjust height of condenser Dials for adjusting light polarizers for DIC imaging Field diaphragm

Saving images Each single scan or series scan that you do sends a file to the experiment folder. These files are held in RAM until you save them to the hard disk. Click [Save all] to save the experiment folder and all of the images within it. The first time you click save you ll be prompted to give the experiment folder a name and location. Save your images in your own directory within the users directory on the C-drive. Unlike with the older Leica confocal software, images are not saved as tifs by default. Instead the LAS AF software will save a single.lif file for all the images within an experiment folder. An individual image or series can be exported as tifs by right clicking on the file in the experiment folder.export. Overlays and projections need to be saved by right clicking on the image Snapshot. These can also be exported as tif in the same way as above. Data on our computers should not be considered secure and should be backed up as soon as possible. Old data is also regularly deleted from our computers at the end of each month. The users directory is shared and can be contacted over the network from your own computer: Using a pc: go to the start menu.run enter \\ ip address of confocal 5 Using a mac: go to go menu.connect to server enter smb:\\ ip address of confocal 5

Ending session Clean oil off lenses with lens tissue. If doing live cell imaging, dampen lens tissue with 100% ethanol, clean lens, then dry lens with a dry piece of lens tissue. Clean other used surfaces with 75% ethanol Fill in log book Check Calendar (http://calendar.bris.ac.uk) selecting resources then bioc-confocal 5 to see if system is booked after you: If someone else is booked on within next 3 hours: Go to Laser configuration window: Turn power on Argon laser down to 0% but leave box ticked Untick other lasers Fluorescent lamp can be switched off if there is a small gap (>5 minutes) before next booking Leave everything else on If there is no booking within the next 3 hours: Go to laser configuration window: Turn down power on the Argon laser to 0% and untick box. Untick all other laser boxes Turn key off (box on right of table) and leave fan running for at least 5 minutes Switch off scan electronics button, exit software and switch off microscope.