INSTALLATION GUIDE. StreamLine Linear Drain. Supply Drainage Support.

Similar documents
INSTALLATION GUIDE StreamLine Linear Drain

Linear Drain Installation Guide

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

BARRIER FREE SHOWER PAN INSTALLATION INSTRUCTIONS

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

Quick Hook SS & LS Standard and Low Height Hooks for Side Mount Rails

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Two Panel Frameless Bypass Door

Frameless Inline Door With Return QCI5263

Quick Hook SB & LB Standard and Low Height Hooks for Bottom Mount Rails

Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY.

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

Before installation, check your local and state requirements for this type of install.

Curtain Wall Installation Guide

Vinyl Windows and Doors Manufactured by Pella Corporation

Sliding Glass Door Assembly and Installation Guide

Extra Wide Heavy Duty Plastic Lockers Series Locker Installation Instructions

TREX ENHANCE RAILING (Also Applies to Trex Select Railing) Installation Instructions

Butyl Flash. Installation Instructions. Prep & General Conditions

FITS MUSTEE 32 X 32 SHOWER RECEPTOR

DURASTALL SHOWER STALL ASSEMBLY INSTALLATION REPAIR PARTS FOR ONE OF THE FOLLOWING MODELS:

FIXED PANEL SLIDER QCI5241

WindowSeal. Installation Instructions. Prep & General Conditions

SERIES: CONFIGURATION: MOUNTING PACKAGE: 1200 Door-Door Frameless, sliding door

Frameless Inline Door QCI5254

Providing 3 Layers of Protection

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283

Series 7650 Installation Instructions Sliding Glass Door

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)

DOOR INSTALLATION GUIDE WOOD FRAMING New Construction

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

THANK YOU FOR PURCHASING FROM HERITAGE PATIOS

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

Vinyl Windows and Doors

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023)

INSTALLATION MANUAL WEEKENDER STEEL LADDER RACK

Sun Windows General Information New Construction Hinged Door Installation Instructions

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE 1400A-1700A-1800A

675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure

DURACRYL WALL INDEX INTRODUCTION. TOOLS AND MATERIALS REQUIRED. FLAT SHOWER WALL SIDE CONTOUR SHOWER WALL CORNER CONTOUR SHOWER WALL FLAT BATH WALL

Eagle clad double-hung window installation instructions

NOTE! The gully must be located centrally under the frame

IMPORTANT INSTALLATION GUIDE VALENCIA ANGLE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Frameless Door QCI5284

Frameless Inline Door QCI5248

Flashing Materials. Rough Opening Preparation

DURACRYL WALL INDEX INTRODUCTION TOOLS AND MATERIALS REQUIRED FLAT SHOWER WALL SIDE CONTOUR SHOWER WALL CORNER CONTOUR SHOWER WALL FLAT BATH WALL

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

Show them you're an InstallationMaster, and watch your business grow. InstallationMasters Training Manual Addendum Level RLC-1

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Installation of Balustrade Systems

Installation Manual MODEL NE-42

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

340 & 350 SERIES DELUXE FRAMELESS BYPASS

INSTALLATION INSTRUCTIONS FREE STANDING TUB FILLERS

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

INSTALLATION INSTRUCTIONS

Frameless Heavy Glass Door with Wall Mount Hinges

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD CASEMENT & AWNING WINDOW VENTANA DE DOS HOJAS CON REVESTIMIENTO

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

3M Air and Vapour Barrier 3015 Technical guide

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

PREMIUM GLASS BATH SCREEN

Oxford Stalls Installation Instructions

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

Chapter 22 - Cabinets & Vanities

INSTALLATION INSTRUCTION FOR CLAD BOW WINDOWS WITHOUT HEAD AND SEAT BOARD

INSTALLATION INSTRUCTIONS

Installation of Fiberglass Windows

PRO CYC PRO CYC, INC. SYSTEM SUPER 1.5QS

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE

FRAMED SLIDING DOOR FOR TUB OR SHOWER ENCLOSURE 6150A-7150A

How To Install Windows: Nail-Fin Application

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

SunTrackerTwo Preparation

Installation Recommendations for Finless Frame Doors

340 & 350 SERIES BATH ENCLOSURES

INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE

Double Frameless Swing Door QCI5247

REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT.

ALL SEASON PATIO COVER

VERSA-COM BOX; TURF VERSION WITH INFILL RETAINMENT BRUSHES ASSEMBLY INSTRUCTIONS

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

TURBOTWISTER TM ASSEMBLY AND INSTALLATION INSTRUCTIONS

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

Chapter 9. Windows and Exterior Doors

TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS

TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS

Series Sloped glazed Curtain wall. Installation Instructions

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

Life* Installation Instructions & User Care Instructions. (381kg) (60stone) (840lbs) (254kg) (40stone) (560lbs) (100kg) (220lb) (15stone)

Transcription:

INSTALLATION GUIDE TM StreamLine Linear Drain Supply Drainage Support www.siouxchief.com

TM StreamLine Linear Drain Installation Instructions 823 SERIES StreamLine Linear Drain Includes: Pre-Strainers Strainer Clamping Collar Pre-Planning Be certain to gather all required tools and materials required prior to installation. Sub-floor Caution: Sub-floor must meet local code requirements and Tile Council of North America (TCNA) guidelines. Clean sub-floor to be sure it is smooth and level. Drain Base Sloped Bed Requirements Follow manufacturers instructions. Use products recommended for the type of sloped bed being installed. StreamLine Linear Drain assembly is intended to install tight to toe plate and studs within shower PRIOR to installation of mortar bed, backer board, waterproofing and tile. Pre-Strainer Screw Screw #8 x 1/2" Phillips Phillips Pan Pan Head Head Screws Pre-Strainer Screws Screw #8 1/2" Phillips to Pan Base Head Strainer to Base Screw Screws #6 1" Phillips Pan Head Screws. Strainer Note: to Base Will Screw not be #6 x 1" Phillips Pan used #6 1" with Phillips Full Pan Mortar Head Head Screws Bed Screws. Kit. Note: Will not be used with Full Mortar Note: Will not be used with Base Bed Full Kit. to Mortar Sub-Floor Bed Screw Kit. #8 2-1/2" Phillips Course Deck Base Screws to to Sub-Floor Screw Screw #8 2-1/2" Phillips Course #8 Deck x 2-1/2" Screws Phillips Course Deck Screws Tube NobleSealant 150 Tube NobleSealant 150 Clamping Collar Screw Screw #6 5/8" x 5/8" Phillips Flat Flat Head Clamping Screws Collar Screw #6 5/8" Phillips Flat Strainer Height Head Strainer Screws Height Adjustment Screw Adjustment Screw #10 Strainer 1-1/4" Height Phillips Flat #10 x 1-1/4" Phillips Flat Head Adjustment Screws. Screw Note: Will Head Screws not #10 be 1-1/4" used with Phillips Full Flat Mortar Head Screws. Bed Kit. Note: Will Base not be to used Sub-Floor, with Full Concrete Mortar Bed Anchor Kit. 1" Base Long to to Sub-Floor, 1/4" Hole Concrete Anchor Anchor 1" Long, 1/4" 1/4" Hole Hole Strainer Height Adjustment Tool Strainer Height Adjustment Tool Strainer Height Adjustment Tool Waste Pipe Location If StreamLine Linear Drain assembly is installed inside toe plates within shower, add a properly sloped mortar bed to fill the space between the toe plates and the drain base. NobleSeal Flashing NobleSeal NobleSeal Flashing* Flashing NobleSealant 150 Note: If NobleSeal will be used to waterproof entire shower, the included piece will not be needed. Fill Waste Pipe Location Fill 1 www.siouxchief.com

Drain Sizes Confirm Drain Size, Waste Pipe Type and Waste Pipe Location Drain hole is off-set to accommodate floor joist location. Size of shower determines size of drain to be used, which determines location of waste pipe through sub-floor. Match 2" I.D Schedule 40 DWV material (PVC or ABS) to drain base material. 2-1/4" 1-1/4" 24" 15-3/4" 1-3/8" 32" 19-1/2" 1-7/16" 40" 23-3/4" 1-5/8" 60" 33-3/4" Typical Drain Locations Slope Back Wall Flush to back wall Full Curb Flush to curb Partial Curb Flush to curb Curb-less Flush to both side walls On Center Flush to both side walls www.siouxchief.com 2

1. Wall Preparation Blocking Blocking between studs may be needed for flashing and membrane attachment prior to drain installation. 3. Waste Pipe Option A: Waste Pipe Not Installed Place, Mark and Cut Place drain base in desired location on sub-floor. Mark waste pipe location on sub-floor. Cut opening in sub-floor to access plumbing below. Mark Cut Hole Place Sub-Floor Blocking 2. Sub-Floor Preparation Caution: Confirm that sub-floor meets all local code requirements and the Tile Council of North America s (TCNA) guidelines. Check for Level. Clean Sub-floor must be smooth and level. Clean sub-floor. Install Waste Pipe Follow local plumbing codes to properly install and secure 2" Sch. 40 ABS or PVC waste pipe 3/4" above sub-floor. Note: Waste pipe may be installed after fastening drain base if accessible from below. 2-1/4" 3/4" Level 2" Sch. 40 ABS/PVC Pipe 3 www.siouxchief.com

3. Waste Pipe (cont.) Option B: Waste Pipe Pre-Installed Dry fit drain base over location of existing waste pipe. If location does not allow drain base to fit flush against at least 2 shower walls, move location of plumbing to allow for proper installation. May also require moving existing studs and toe plate. 4. Preparation for Sloped Mortar Bed Mark Bed Slope 1/4" per foot slope to drain is required. Dry Fit 3/4" Studs Mark Waste Pipe Must Fit Flush to Sub-Floor 1/4" Per Foot Slope Front Edge of Drain Base Alternate Drain Mounting Methods Recessed mount in concrete substrate Recessed mount in wood sub-floor Note: Any modification of substrate must comply with local building codes. www.siouxchief.com 4

5. Fasten Drain Base to Sub-Floor For Concrete Sub-Floor A & B For Wood Sub-Floor B only A. Mark for Anchors Dry fit drain base over waste pipe. Mark all holes in outside flange of drain base on concrete floor. Remove drain base. Drill 1/4" holes, 1-1/2" deep where marked. Drive plastic anchors flush into all holes. 6. Sloped Mortar Bed Installation Protect Drain Base. Apply tape over entire top surface of drain base. Install Sloped Bed. Follow industry standards to complete sloped mortar bed installation. Be certain mortar completely fills void below drain base flange. Allow to dry before proceeding. Tape Mortar Bed B. Install Drain Base to Waste Pipe and Sub-Floor Caution: Confirm proper plastic pipe primer and cement for drain base type (PVC or ABS). Check drain base label to confirm. Apply appropriate plastic pipe primer and cement to drain and waste pipe following local plumbing codes and manufacturers instructions. Fit and fully seat drain base onto waste pipe. Fasten drain base to sub-floor by screwing 2-1/2" deck screws through all holes in outside flange of drain base into plastic anchors or directly into wood sub-floor. DO NOT OVER-TIGHTEN. 5 www.siouxchief.com

7. Prepare Flashing Option 1: For Drain at Back Wall Making Corners Tucked Corner (when space is available between studs) Fold and crease to size. Tuck shower pan liner into space between studs. Flashing must turn up the walls a minimum of 3" above shower curb and 6" above floor in showers without curbs. Measure width of shower floor across drain base. Lay flashing flat. Measure and mark flashing. Fold and crease for upturns and create corners. Note: Do not secure flashing at this time. 6" Tuck between Studs Fold Tuck or Fold Folded Corner Fold and crease to size. Fold corners behind shower pan liner. 6" Fold Corners Behind www.siouxchief.com 6

7. Prepare Flashing (cont.) Option 2: For Drain at Full Curb Entry Option 3: For Drain at Partial Width Curb Flashing must turn up the walls a minimum of 3" above shower curb and 6" above floor in showers without curbs. Prior to installing flashing, install pre-formed outside corners (available separately) following manufacturer s instructions. 2 per side. Measure width of shower floor across drain base. Measure up and over curb. Lay flashing flat. Measure and mark flashing. Cut, fold and crease to proper size and fit. Note: Do not secure flashing at this time. Note: Preformed curbs may also be used. See manufacturer s instructions. Flashing must turn up the walls a minimum of 3 above shower curb and 6 above floor in showers without curbs. Prior to installing flashing, install pre-formed outside corners (available separately) following manufacturer s instructions. 2 per side. Measure width of shower floor across drain base. Measure up and over curb. Lay flashing flat. Measure and mark flashing. Cut, fold and crease to proper size and fit. Note: Do not secure flashing at this time. Note: Preformed curbs may also be used. See manufacturer s instructions. Inside Shower Inside Shower 6" min. Outside Corners Under Flashing 6" min. Tuck or Fold Outside Corners Under Flashing Outside Shower Outside Shower 3" min. Outside Corners Under Flashing 3" min. Outside Corners Under Flashing 7 www.siouxchief.com

7. Prepare Flashing (cont.) Option 4: For Drain at Curbless Entry Flashing must turn up the walls a minimum of 3" above shower curb and 6" above floor in showers without curbs. Measure width of shower floor across drain base. Lay flashing flat. Measure and mark flashing. Cut, fold and crease to proper size and fit. Option 5: For Drain in Center of Floor Flashing must turn up the walls a minimum of 3" above shower curb and 6" above floor in showers without curbs. Measure width of shower floor across drain base. Lay flashing flat. Measure and mark flashing. Fold and crease for upturns. Note: Do not secure flashing at this time. Note: Do not secure Shower Pan Liner at this time. Inside Shower 6" min. Outside Corners Under Flashing 6" min. Fold Fold Outside Shower 2" min. Fold Outside Corners Under Flashing www.siouxchief.com 8

8. Secure Flashing A. Seal Drain Base Lift out flashing. Remove tape, leaving tape over drain hole only. Apply a 1/8" continuous bead of NobleSealant 150 around chamfer on base flange and another bead in groove on drain base. C. Press Into Sealant and Adhesive Align flashing and firmly press all areas of flashing into adhesive on walls, floor, curb and sealant on drain base and any pre-formed corners. Chamfer Groove 2 Beads NobleSealant 150 B. Apply Adhesives Apply latex-modified thin-set to mortar bed, walls and curb as needed. Apply NobleSealant 150 to any preformed corners. Adhesive 9 www.siouxchief.com

9. Fasten Flashing Nail through top 1" of flashing to studs and/or blocking. 11. Cut Out Flashing With a razor knife, carefully trim out flashing from center of collar. Remove tape from drain hole. Caution: Do not puncture flashing outside of collar. Nail Cut Out Flashing 10. Install Clamping Collar Align collar with drain base under flashing. Press firmly. Starting at one end, insert 5/8" screw through collar, punch through flashing and screw into base. Repeat for all screws. DO NOT OVER-TIGHTEN. 12. Complete Floor Waterproofing Complete installation of bonded waterproofing membrane (ANSI A118.10) on shower floor. Clamping Collar Overlap 2" Min. for any joints/seams in flashing www.siouxchief.com 10

13. Flood Test Flood test as required by local codes. 16. Install Height Adjustment Screws Screw in all 1-1/4" flat head height adjustment screws to approximately 3/8" above the clamping collar. 1-1/4" Screws 14. Install Backer Board and Wall Waterproofing 3/8" Note: TCNA guidelines require waterproofing or a vapor membrane be installed on all walls. Install 1/2" backer board and wall waterproofing according to manufacturer s instructions, local plumbing codes and TCNA guidelines. 3/8" Caution: Do not puncture flashing. Clamping Collar 15. Install Pre-Strainers Place short leg of Pre-Strainer down, facing drain hole. Install 1/2" pan head screw, align strainer and tighten screw. Repeat for opposite strainer. Note: On 24" drain, place long leg of Pre-Strainer down, facing drain hole. 17. Temporarily Attach Strainer Note: Strainer attachment holes are not symmetrical. If screws do not align with holes in drain base, turn strainer end-to-end. Place strainer over height adjustment screws. Temporarily fasten with three 1" pan head screws. DO NOT OVER-TIGHTEN. 1/2" Screws Pre-Strainer 1" Screws Strainer Short Leg 11 www.siouxchief.com

18. Tile and Grout Be certain strainer is protected with tape. Allow for 1/16" clearance between strainer and tile. Caution: Do not grout or seal this space. Tile and grout all surfaces following manufacturers instructions and TCNA guidelines. 20. Re-Install Strainer Note: Strainer attachment holes are not symmetrical. If screws do not align with holes in drain base, turn strainer end-to-end. Place strainer over height adjustment screws. Confirm that strainer is flush with all tiles. Fasten with three 1" pan head screws. DO NOT OVER-TIGHTEN. Tile 1/16" Cleanance Do Not Seal Or Grout 1" Screws Strainer 19. Adjust Strainer Height Remove strainer. Remove tape from strainer and clean any remaining residue. Place thin end of height adjustment tool on tile and rest other end on height adjustment screw. Adjust screws so heads are flat against bottom of tool, and tool is flat against tile. Repeat for all height adjustment screws. Height Adjustment Tool Remove Strainer Adjust Screws www.siouxchief.com 12

Cleaning Drain To clean drain, remove 3 screws in top of strainer. Clear any hair or other obstructions from drain. Remove Strainer 1" Screws Strainer Re-Attach Strainer Note: Strainer attachment holes are not symmetrical. If screws do not align with holes in drain base, turn strainer end-to-end. Place strainer over height adjustment screws. Replace all three screws. DO NOT OVER-TIGHTEN. 1" Screws Strainer 13 www.siouxchief.com

More than 50 years ago, Sioux Chief started manufacturing rough plumbing products. Today, we still do right in the heart of America. Many of you knew us when we started out. Some of you came to know us as we grew. Along the way, we made a name for ourselves with quality products, innovative ideas and dependable service. Since our start, Sioux Chief has changed a great deal. However, we are also very much the same. We make high quality rough plumbing products and systems that help plumbing contractors grow their businesses. We innovate. We manufacture in America. And we could not do it without you. Thank you for your business. We promise to continue to work hard to support you. Together, we will take the field. www.siouxchief.com 14

PMG 1065 File No. 7249 www.siouxchief.com B.2/18 #IS-823 STREAMLINE INSTALLATION INSTRUCTIONS