NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A

Similar documents
Busbar Trunking Assembly

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit

RX 3 ->CATALOG PAGES INSIDE. the global specialist

Page 13-2 Page Page 13-7

RX 3 ->CATALOG PAGES INSIDE. the global specialist

(1,5 modules per pole)

Circuit protection devices

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

A9 R Range Family Code Internal code Poles Code Rating (A) Code Acti 9 (A9) iid R

NEW CIRCUIT PROTECTIONRANGE

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

COPYTRACER Anti-counterfeit registration number

Series P. Applications

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD)

Technical features table for miniature circuit-breakers SH 200 Series

Electrical Protection System Design and Operation

3 - Protection components Circuit-breakers

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

Residual current circuit breakers (RCCBs)

technical information

Components for Marine applications

Residual Current Operated Circuit-Breakers (RCCBs)

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Residual Current Operated Circuit-Breakers (RCCBs)


Technical catalogue. Emax Low voltage air circuit-breakers. Hotline:

Low Voltage. Residual-current protection relays

Protection of Electrical Networks. Christophe Prévé

Orbital GFI Inverter Series

Siemens AG New portfolio for reliable personnel, material and fire protection

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

SPAD 346 C Stabilized differential relay

Maintenance/Connection/Installation Service life C/O cyclesx1000

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Chapter 6. WIRING SYSTEMS Safe Electrical Design

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Protection and control VIP300. Technical manual

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Protection relays and transformers

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

Substation applications

TS RES - OUTSTANDING ISSUES

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

VI 3 - i TABLE OF CONTENTS

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

Three-phase monitoring relay

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

Circuit breakers for direct current applications

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

Integration between the MV protection and control unit REF542 and the LV protection trip unit PR123: selectivity and earth fault 1SDC007402G0201

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

Smart Power Relay E I...

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION)

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Stabilized Differential Relay SPAD 346. Product Guide

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

Power Quality Solutions

The future of installation testing is here. The 1650 Series Multifunction Testers

Type CP-S, CP-C & CP-A Switch mode

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

Power IT LV Active Filters PQFA - PQFL - PQFT

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Industrial Miniature Circuit-Breakers S 220 series

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

Instantaneous Overcurrent Relay

ER 87 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) ESR 27(2) (2 marks) ESR 74A(1AA)

90 ReStart AUTOMATIC RECLOSING DEVICES

04 Page. MCCBs characteristics 94. MCCBs & accessories selection guide 96. MCCBs x MCCBs x MCCBs h

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

Transformers, Power Supply Units and Socket Outlets

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

Inverter MICROMASTER 410

Datasheet - PROTECT-IE-02

Motor Protection Circuit Breaker Series 8146/5-V27

PROFiTEST C Test Instrument per DIN VDE /8.14

iprd, iprd IT surge arresters Type 2 or 3 LV withdrawable surge arresters

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET

7P Series - Surge Protection Device (SPD) Features 7P P P

Electrical Description

Automatic capacitor banks with detuned filters

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

Transcription:

High performance circuit breaker mcb and combined mcb with remote controls LV Distribution Products 2-63A

Mini motorized circuit breaker The mini-series of motorized circuit breakers operates both locally & with remote control The mimi-series circuit breakers are rated maximum up to 63A and have 2-pole and 4 pole versions. It gives protection against short-circuit and overloads. Also used as a breaking element. Includes auxiliary contacts for indicating overload status. After a disconnection from short-circuit, overload or manual disconnection, the overload switch may be connected again using an electrical order with the sequence "CONNECTION (I) - DISCONNECTION (0)" In Curve C Curve D Curve C Curve D (A) Type Code Type Code Type Cede Type Code 6 mini-mcc-e62/6a MC-P20110 mini-mcd-e62/6a MC-P20130 mini-mcc-e62/6a MC-P20120 mini-mcd-e62/6a MC-P20140 10 mini-mcc-e62/10a MC-P20111 mini-mcd-e62/10a MC-P20131 mini-mcc-e62/10a MC-P20121 mini-mcd-e62/10a MC-P20141 16 mini-mcc-e62/16a MC-P20112 mini-mcd-e62/16a MC-P20132 mini-mcc-e62/16a MC-P20122 mini-mcd-e62/16a MC-P20142 20 mini-mcc-e62/20a MC-P20113 mini-mcd-e62/20a MC-P20133 mini-mcc-e62/20a MC-P20123 mini-mcd-e62/20a MC-P20143 25 mini-mcc-e62/25a MC-P20114 mini-mcd-e62/25a MC-P20134 mini-mcc-e62/25a MC-P20124 mini-mcd-e62/25a MC-P20144 32 mini-mcc-e62/32a MC-P20115 mini-mcd-e62/32a MC-P20135 mini-mcc-e62/32a MC-P20125 mini-mcd-e62/32a MC-P20145 40 mini-mcc-e62/40a MC-P20116 mini-mcd-e62/40a MC-P20136 mini-mcc-e62/40a MC-P20126 mini-mcd-e62/40a MC-P20146 50 mini-mcc-e62/50a MC-P20117 mini-mcd-e62/50a MC-P20137 mini-mcc-e62/50a MC-P20127 mini-mcd-e62/50a MC-P20147 63 mini-mcc-e62/63a MC-P20118 mini-mcd-e62/63a MC-P20138 mini-mcc-e62/63a MC-P20128 mini-mcd-e62/63a MC-P20148 FEATURES Rating In (A) Number de Poles Rated cut off power Characteristic curve Overload 6-10-16-20-25-32-40-50-63 2 4 10 ka C or D according to type Rated voltage FEATURES Motor 230 V a.c. Rated operating voltage 240 / 415 V a.c. Minimum voltage 210 V a.c. Operating frequency range 50...60 Hz Activation impulse 50 ms Operating temperature -25... +55 C Deactivation impulse 50 ms Storage temperature -55... +55 C Mechanical features Mounting Panel (base + pluggable base) Dimensions 3 Poles: 81 x 130 x 185 Mechanical life 4 Poles 108 x 130 x 185 Weight According to type Protection degree IP 40 (DIN 40050) Standards IEC 947-2, IEC 60898

Miniature circuit breakers Model: X60H IEC 947-2 : 10KA type width rat. Product Product in mod. (A) ref. ref. of 9 mm B curve C curve 1P 3 2 3605102 3615102 6 3605106 3615106 1 10 3605110 3615110 16 3605116 3615116 20 3605120 3615120 25 3605125 3615125 32 3605132 3615132 40 3605140 3615140 2 50 3605150 3615150 63 3605163 3615163 1 protected pole 2P 6 2 3605202 3615202 1 3 6 3605206 3615206 10 3605210 3615210 16 3605216 3615216 20 3605220 3615220 25 3605225 3615225 32 3605232 3615232 2 4 40 3605240 3615240 50 3605250 3615250 63 3605263 3615263 2 protected poles 3P 9 2 3605302 3615302 6 3605306 3615306 1 3 5 10 3605310 3615310 16 3605316 3615316 20 3605320 3615320 25 3605325 3615325 32 3605332 3615332 2 4 6 40 3605340 3615340 50 3605350 3615350 63 3605363 3615363 3 protected pole Application: J control and protection of circuits against overloads and short-short-circuits in industrial distribution system. Technical data: J current rating: 2 to 63A at 40 o C. J voltage rating : 240/415 V AC. J breaking capacity: 10kA to IEC 947.2 (Icu) and BS 4752 (O-CO sequence) rat. type volt. breaking (A) (V) capacity (A) 10 to 1P 230/240 10000 63A 2, 3, 4P 230/240 20000 2, 3, 4P 400/415 10000 J positive contact indication J fast closing J tripping characteristics: B type : magnetic setting between 3 and 5In C type : magnetic setting between 5 and 10In J number of operating cycles (O-C) : 20000. J tropicalization : treatment 2 (relative humidity 95% at 55 o C). J weight (g): type 1P 2P 3P 4P 180 360 540 720 J connections : tunnel terminals for rigid cables up to: 25 mm 2 for rating o 25A 35 mm 2 for rating o 63A 4P 12 2 3605402 3615402 6 3605406 3615406 1 3 5 7 10 3605410 3615410 16 3605416 3615416 20 3605420 3615420 25 3605425 3615425 32 3605432 3615432 2 4 6 8 40 3605440 3615440 50 3605450 3615450 63 3605463 3615463 4 protected poles

Residual current circuit breaker (rccb) 10/30/100/300/500mA 100/300 ma time delayed type width rat. sens. BS4293 in mod. (A) (ma) 240V of 9 mm 50 Hz Cat. No 2P 25 10 366213 30 366214 300 366216 40 30 366231 300 366236 300 (S) 366237 Application: The rccb residual current devices provide the functions of isolation, switching and earth leakage protection of electrical circuits. They have a residual current operated electromechanical release which operates without any auxiliary source of supply to open a circuit automatically in the case of an earth leakage fault between phase and earth greater than or equal to a threshold of 10, 30, 100, 300 or 500 ma. T R N 1 N 2 63 30 366241 100 366243 300 366246 300 (S) 366247 80 30 366249 100 366251 300 366253 300 (S) 366254 J rccb time-delayed versions j 100 ma : provides discrimination with down stream 10mA and 30 ma sensitivity instantaneous residual current devices. j 300 ma : provides discrimination with down stream 30mA and 100 ma sensitivity instantaneous residual current devices. Technical data 100 30 366259 100 366261 300 366262 300 (S) 366263 J unwanted tripping All rccb incorporate a filtering device preventing the risks of unwanted tripping due to transient voltages (lightning, line disturbances on other equipment and transient currents (from high capacitive circuits. type width rat. sens. BS4293 in mod. (A) (ma) 415V of 9 mm 50 Hz Cat. No 4P 25 30 366414 J isolation and switching J positive contact indication : in accordance with 15th Edition of the IEE wiring regulations (Regs 537-5, 537-9). J trip indication on the front face by red flag. J compliance with standards rcd: BS 4293: 1983 or CEE 27 J current ratings: 16A to 100A. T R N 1 3 5 300 366416 40 30 366431 100 366433 300 366436 300(S) 366437 500 366438 63 30 366441 100 366443 300 366446 300 (S) 366447 80 300 366453 300 S 366456 100 300 366462 J voltage ratings: 2 poles: 240V AC +10-20% 4 poles: 415V AC +10-20% J sensitivities (non-adjustable) J operating temperature: -5 to +60 o C (-25 o C : consult us). J connections tunnel terminals for cables up to 35 mm 2 J number of operating cycles (on load) 20 000 cycles (O-C). J tropicalization: treatment 2 (relative humidity 95% at 55 o C. J weight (g) 2P 230 4P 450 N 2 4 6 300 S 366463

Miniature circuit breakers Model: X60N IEC 947-2 : 6KA Type Width In Product Product in mod. (A) ref. ref. of 9 mm B curve C curve 1P 2 2 3604102 3614102 6 3604106 3614106 1 10 16 3604110 3604116 3614110 3614116 20 3604120 3614120 25 3604125 3614125 32 3604132 3614132 40 3604140 3614140 2 50 3604150 3614150 63 3604163 3614163 1 protected pole 2P 4 2 3604202 3614202 1 3 6 3604206 3614206 10 3604210 3614210 16 3604216 3614216 20 3604220 3614220 25 3604225 3614225 32 3604232 3614232 2 4 40 3604240 3614240 50 3604250 3614250 63 3604263 3614263 2 protected poles Function: Adex circuit breaker combines the following functions : - protection of circuit against short-circuit current. - protection of circuit against overload current. - controls. Application: Specially suitable for residential /commercial and industrial installations. Technical data: - current rating : 2-63A - voltage rating : 230/400V ~ - breaking capacity : 6kA to IEC 947-2 - number of operating cycles (O-C) : 20000 - tripping characteristics : B & C curve connection: Tunnel terminals for cables up to 25mm 2 installation: standard 35 mm DIN rail mounted. 3P 6 2 3604302 3614302 6 3604306 3614306 1 3 5 10 3604310 3614310 16 3604316 3614316 20 3604320 3614320 25 3604325 3614325 32 3604332 3614332 2 4 6 40 3604340 3614340 50 3604350 3614350 63 3604363 3614363 3 protected pole 4P 6 2 3604402 3614402 6 3604406 3614406 1 3 5 7 10 3604410 3614410 16 3604416 3614416 20 3604420 3614420 25 3604425 3614425 32 3604432 3614432 2 4 6 8 40 3604440 3614440 50 3604450 3614450 63 3604463 3614463 4 protected poles

Bitoron- 400 LV power distribution system Specifications bitoron - 400 flush/surface mounting modular enclosures compliance with IEC 60439-1 bitoron-400 enclosures are made of 1.6 mm sheet metal anti-rust conditioning phosphatized & thermal polymerized polyester-epoxy powder paint or thermal stove enamel paint coated detachable gland plates(top & Bottom) for incoming and outgoing cables painting colour bitoron beige (others on request) DIN rail, neutral link earth bar and busbar 1, 2, 3, 4 poles breaker rating 2 to 63 A MCB s can be fitted conveniently at site on DIN rail suitable for use on 240/415V, 50/60Hz system degree of protection IP31 1 front plate with holes for circuit breaker s knob single door with lock bitoron 400-D suitable for 1/2 poles mcb w H h W D No of rows No of mcb Dimension Part No. W x H x D 1 1P-12 230x200x96 407-232009-00A

Remote controlled circuit breaker The combin-p or combin-t are circuit breakers which combine overload functions with contactor functions in the same equipment. The combin-t version also includes two auxiliary contacts which show the status of the remote control input and the overload input. Both the combin-p and the combin-t version include an ordinary contact to indicate a trip from an overload device or from the manual action of the circuit breaker. There are two trip conditions for the circuit breaker: I Tripping from overheating, delayed, (overload protection) I Rapid tripping, electromagnetic (protection against short-circuiting) Remote-control operates on the same contacts as the overload device. It guarantes disconnection for any event by remote control after manual or overload device tripping. The remote control operates electro-magnetically, applying a control voltage lasting 20 ms, to the ON terminals (Terminals 1-3) and OFF terminals (Terminals 2-3). It includes an optical displays of the system status (red = ON, green = OFF), regardless of the cause of the trip. In (A) Combin - P Combin - T Combin - P Combin -T Type Code Type Code Type Code Type Code 6 Combin-PC-2P/6A RC-P20210 Combin-TC-2P/6A RC-P20310 - - - - 10 Combin-PC-2P/10A RC-P20211 Combin-TC-2P/10A RC-P20311 Combin-PC-3P+N/10A RC-P20221 Combin-TC-3P+N/10A RC-P20321 16 Combin-PC-2P/16A RC-P20213 Combin-TC-2P/16A RC-P20313 Combin-PC-3P+N/16A RC-P20223 Combin-TC-3P+N/16A RC-P20323 20 Combin-PC-2P/20A RC-P20214 Combin-TC-2P/20A RC-P20314 Combin-PC-3P+N/20A RC-P20224 Combin-TC-3P+N/20A RC-P20324 25 Combin-PC-2P/25A RC-P20215 Combin-TC-2P/25A RC-P20315 Combin-PC-3P+N/25A RC-P20225 Combin-TC-3P+N/25A RC-P20325 32 Combin-PC-2P/32A RC-P20216 Combin-TC-2P/32A RC-P20316 Combin-PC-3P+N/32A RC-P20226 Combin-TC-3P+N/32A RC-P20326 40 Combin-PC-2P/40A RC-P20217 Combin-TC-2P/40A RC-P20317 Combin-PC-3P+N/40A RC-P20227 Combin-TC-3P+N/40A RC-P20327 50 Combin-PC-2P/50A RC-P20218 Combin-TC-2P/50A RC-P20318 Combin-PC-3P+N/50A RC-P20228 Combin-TC-3P+N/50A RC-P20328 63 Combin-PC-2P/63A RC-P20219 Combin-TC-2P/63A RC-P20319 Combin-PC-3P+N/63A RC-P20229 Combin-TC-3P+N/63A RC-P20329 FEATURES Overload Rating In (A) 6-10-16-20-25-32-40-50-63 Rated cut off power (IEC 947-2) 6...16 A: 20 ka 20...63 A: 15 ka Characteristic curve C or D according to type Rated operating voltage 230 / 400 V a.c. Operating frequency range 50...60 Hz Operating temperature - 25... +55 C Storage temperature - 40... +70 C Rated voltage Activation impulse Deactivation impulse Mechanical features Mounting Dimensions Mechanical life Weight Protection degree Standards FEATURES Motor 230 V a.c. < 20 ms < 20 ms DIN rail 3 modules 5 modules 20 000 operations 375 g 615 g IP 20 (DIN 40050) IEC 947-2, IEC 60898

Bitoron- 400 LV power distribution system bitoron 400-F suitable for 1/2/3 poles mcb w H h W D No of rows No of mcb Dimension Part No. W x H x D 1 1P-12 400x200x96 407-402009-00A 2 1P-24 400x400x96 407-404009-00A bitoron 400-M suitable for mccb as incomer & 1/2/3 poles mcb as outgoer w H h W D Type of Vert. mod for incomer No of No of Dimension Part No. Incomer mccb of 50mm rows mcb W x H x D 362437-100A 6 1 1P-12 400x500x125 407-402011-00A 362441-160A 6 2 1P-24 400x700x125 407-404011-00A 362445-200A 6 3 1P-36 400x900x125 407-406011-00A ADEX ENGINEERING LIMITED. Corporate Office : Baitul Abed 53 Purana Paltan (3rd Floor) Dhaka-1000, Bangladesh. Phones : 02-9559868, 9559826 Fax : 02-956 2705 e-mail : info@adexbd.com Web : www.adexbd.com Sales Office : Shakh Centre 56 Purana Paltan (3rd Floor) Dhaka-1000, Bangladesh. Phone : 02-956 0626 Fax : 02-956 2705 e-mail : sales@adexbd.com, web : www.adexbd.com Chittagong Office : Bank Asia Bhaban (4th Floor) 69 Agrabad Commercial Area Chittagong, Bangladesh. Phone : 031-2523993 e-mail : adex_ctg@adexbd.com web : www.adexbd.com Factory : West Dogri, Bhawal Mirzapur Gazipur, Bangladesh. e-mail : ael_works@adexbd.com web : www.adexbd.com Q:3000-Jan_15_gd_pulin