Lecture 2 Slit lamp Biomicroscope

Similar documents
11/10/2015. Haag Streit Topcon Zeiss Kowa Add On Systems- OIS/Escalon and Others. The Original Design. Photo Slit lamp Systems. Who Makes Them?

Eyes. Inspection Visual Acuity Visual Fields Pupillary Response Fundoscopic Exam

Smart-Device Ophthalmic Photography

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

OCULAR MEDIA* PHOTOGRAPHIC RECORDING OF OPACITIES OF THE. development by the control of diabetes, the supply of a deficient hormone

EYE ANATOMY. Multimedia Health Education. Disclaimer

Digital Slit Lamp Photography. A User s Primer

2 The First Steps in Vision

Television slit-lamp biomicroscopy

1. Introduction to Anatomy of the Eye and its Adnexa

Wide Angle Ophthalmoscope Instructions

Gonioscopy Wet-Lab. About Me. About Me Gonioscopy. Indications for Gonioscopy. Billing Gonioscopy 12/13/2012. Code: 92020

Basic Principles of the Surgical Microscope. by Charles L. Crain

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

Uses of the Slit Lamp. Parts of the Slit Lamp

Instruments Commonly Used For Examination of the Eye

11 Human Eye & colourful world IMPORTANT NOTES ANIL TUTORIALS

ensory System III Eye Reflexes

HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

Refraction, Lenses, and Prisms

EYE STRUCTURE AND FUNCTION

GIST OF THE UNIT BASED ON DIFFERENT CONCEPTS IN THE UNIT (BRIEFLY AS POINT WISE). RAY OPTICS

Keeler Direct Ophthalmoscopes

Chapter 36. Image Formation

In the following diagram the parts of the eye are visualized and labeled for you.

By Dr. Abdelaziz Hussein

Physics Chapter Review Chapter 25- The Eye and Optical Instruments Ethan Blitstein

Sense Organs (Eye) The eye is the sense organ of sight. The eye is shaped like a ball and is located in bony

Macrophotography of the anterior

Chapter 29/30. Wave Fronts and Rays. Refraction of Sound. Dispersion in a Prism. Index of Refraction. Refraction and Lenses

Instructional Resources/Materials: Light vocabulary cards printed (class set) Enough for each student (See card sort below)

Chapter Introduction. Chapter Wrap-Up. and the Eye

Macula centred, giving coverage of the temporal retinal. Disc centred. Giving coverage of the nasal retina.

Objectives. 3. Visual acuity. Layers of the. eye ball. 1. Conjunctiva : is. three quarters. posteriorly and

Chapter 6 Human Vision

Chapter 36. Image Formation

Image Modeling of the Human Eye

Light Microscopy. Upon completion of this lecture, the student should be able to:

30 Lenses. Lenses change the paths of light.

Chapter 25. Optical Instruments

Ocular Lenses. Head. Arm. Objective Lenses. Slide Holder Stage. On / Off Switch. Condenser with Iris Diaphragm. Light Intensity Control

Telemedical diagnosis of anterior segment eye diseases: validation of digital slit-lamp still images

Sensory receptors External internal stimulus change detectable energy transduce action potential different strengths different frequencies

The microscope is useful in making observations and collecting data in scientific experiments. Microscopy involves three basic concepts:

Class 10 Science NCERT Exemplar Solutions Human Eye and Colourful World

Reports. \ $mm>-j \ksiiimj

Vocabulary. Unit 9 Forms of Energy. ENERGY: The capacity for doing work.

Life Science Chapter 2 Study Guide

4Basic anatomy and physiology

Lenses- Worksheet. (Use a ray box to answer questions 3 to 7)

Person s Optics Test KEY SSSS

Sheep Eye Dissection

MAKING SENSE OF SLIT LAMP SERVICING

LAB 12 Reflection and Refraction

Dr. Magda Rau Eye Clinic Cham, Germany

Use these words to complete the sentences about light: absorb different diffuse focus prism refraction same slower specula transmit

Chapter Human Vision

Health Science 1110 Module 9 Sensations LAB 9. View the Film on Cornea Transplant and answer the questions on your laboratory worksheet.

Introduction. Chapter Aim of the Thesis

Biology 70 Slides for Lecture 1 Fall 2007

Handout G: The Eye and How We See

OPTICAL SYSTEMS OBJECTIVES

Section 1: Sound. Sound and Light Section 1

ABO Certification Training. Part I: Anatomy and Physiology

Mastery. Chapter Content. What is light? CHAPTER 11 LESSON 1 C A

Notes: Light and Optics. Reflection. Refraction. Law of Reflection. Light goes straight 12/13/2012

Light and Applications of Optics

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

family of lens designs fitting guide ICD is Exclusively Manufactured In

3. Study the diagram given below and answer the questions that follow it:

Yokohama City University lecture INTRODUCTION TO HUMAN VISION Presentation notes 7/10/14

Introduction. Strand F Unit 3: Optics. Learning Objectives. Introduction. At the end of this unit you should be able to;

ECEN 4606, UNDERGRADUATE OPTICS LAB

Chapter 23. Mirrors and Lenses

Basics of Light Microscopy and Metallography

Visual Optics. Visual Optics - Introduction

12.1. Human Perception of Light. Perceiving Light

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

General Physics Experiment 5 Optical Instruments: Simple Magnifier, Microscope, and Newtonian Telescope

Lenses. A lens is any glass, plastic or transparent refractive medium with two opposite faces, and at least one of the faces must be curved.

ECEN 4606, UNDERGRADUATE OPTICS LAB

The Eye. Nakhleh Abu-Yaghi, M.B.B.S Ophthalmology Division

The Human Eye and a Camera 12.1

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

EYE. The eye is an extension of the brain

Chapter 16 Light Waves and Color

Vision 1. Physical Properties of Light. Overview of Topics. Light, Optics, & The Eye Chaudhuri, Chapter 8

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Mirrors and Lenses. Images can be formed by reflection from mirrors. Images can be formed by refraction through lenses.

Using a Microscope. Year Group: BVSc1 + Document number: CSL_L07

Practice Problems for Chapter 25-26

Figure 1. Relative intensity of solar energy of different wavelength at the earth's surface.

Physics 9 Wednesday, February 1, 2012

Vision. The eye. Image formation. Eye defects & corrective lenses. Visual acuity. Colour vision. Lecture 3.5

Topic 4: Lenses and Vision. Lens a curved transparent material through which light passes (transmit) Ex) glass, plastic

Chapter 3 Optical Systems

Chapter Ray and Wave Optics

HEINE Direct Ophthalmoscopes

Unit Two Part II MICROSCOPY

Lecture 8. Lecture 8. r 1

Transcription:

Lecture 2 Slit lamp Biomicroscope 1

Slit lamp is an instrument which allows magnified inspection of interior aspect of patient s eyes Features Illumination system Magnification via binocular microscope 3 Slit lamp is used to evaluated the health of anterior segment of the eye it also conjunction with auxiliary lenses to view the anterior champers and retina 2

Basic components of slit lamp 1- Illumination arm contain the illumination system and the angle can be change from 0-90. It is has A- Slit controls to control the light width and orientations B- Click stop it is change the position of the reflecting mirror to change the angle of the beam with respect to the viewing system C- Filters used to change the appearance of the beam like cobalt blue filter green or red free filter 3

Basic Components: illumination Bulb Filters Slit height control Slit rotator Mirror Slit width control 5 Filters 1.Unfiltered 2. Heat absorbing 3. 10% Grey 4. Red free 5. Cobalt blue 1 2 3 4 5 6 4

Width 8 5

Microscope arm A- Oculars : it can adjust to the examiner refractive error the distance between them can be adjust as the examiner IPD B-Magnification changer Slit lamp position controls - Joystick ( elevation knops ) to control the movement of the slit lamp forward and right left movement to have sharp focus 6

Basic Components: magnification Eye pieces Magnification changer Joy stick Lock Base 10 7

Magnification Most slit lamps have: 2 objective settings (1 and 1.6) 2 eye piece options (10x and 16x) Total magnification ranges thus from 10x-25x 11 12 8

Use of the Slit Lamp Seat patient comfortabl y Adjust table, chair Position patient s head 13 Focus Patient s Eye Microscope straight Light column 20-30 degrees from side Microscope moves via joystick Move laterally Move in and out 14 9

Adjust the Illumination Brightness: filters Width: slit vs broad beam Height: long vs pinpoint 15 10

Illumination techniques Diffuse illumination Direct illumination Parallelepiped Optic section Conical(pinpoint) Tangential Specular reflection Indirect illumination Retro-illumination Sclerotic scatter Transillumination 11

Diffuse illumination Angle between microscope and illumination system should be 30-45 degree. Slit width should be widest. Filter to be used is diffusing filter. Magnification: low to medium Illumination: medium to high. Applications: General view of anterior of eye: lids,lashes,sclera,cornea,iris,pupil, Gross pathology and media opacities Contact lens fitting. Assessment of lachrymal reflex. Optics of diffuse illumination Diffuse illumination with slit beam and background illumination 12

Direct illumination Involves placing the light source at an angle of about 40-50 degree from microscope. This arrangement permits both light beam and microscope to be sharply focused on the ocular tissue being observed. Wide beam direct illumination is commonly used as a preliminary technique to evaluate large area It is particularly suitable for assessment of cataracts, scars, nerves and vessels. It is also important for the determination of stabilization of axis of toric contact lens Parallelepiped: Constructed by narrowing the beam to 1-2mm in width to illuminate a rectangular area of cornea. Microscope is placed directly in front of patients cornea. Light source is approximately 45 degree from straight ahead position. 13

Applications: Used to detect and examine corneal structures and defects. Used to detect corneal striae that develop when corneal edema occurs with hydrogel lens wear and in keratoconus. Higher magnification than that used with wide beam illumination is preferred to evaluate both depth and extent of corneal, scarring or foreign bodies. 14

Conical beam (pinpoint) Produced by narrowing the vertical height of a parallelepiped to produce a small circular or square spot of light. Light source is 45-60 degree temporally and directed into pupil. Biomicroscope: directly in front of eye. Magnification: high(16-25x) Intensity of light source to highest setting. Focusing: Beam is focused between cornea and anterior lens surface and dark zone between cornea and anterior lens observed. Principle is same as that of beam of sun light streaming through a room,illuminating airborne dust particles. Most useful when examining the transparency of anterior chamber for evidence of floating cells and flare seen in anterior uveitis. 15

Optic section Optic section is a very thin parallelepiped and optically cuts a very thin slice of the cornea. Axes of illuminating and viewing path intersect in the area of anterior eye media to be examined e.g. the individual corneal layers. Angle between illuminating and viewing path is 45 degree. Slit length should be kept small to minimize dazzling the patient. 16

With narrow slit the depth and portion of different objects(penetration depth of foreign bodies, shape of lens etc) can be resolved more easily. With wider slit their extension and shape are visible more clearly. Magnification: maximum. Examination of AC depth is performed by wider slit width.1-.3mm. Used to localize: Nerve fibers Blood vessels Infiltrates Cataracts AC depth. Optical section of lens 1.Corneal scar with wide beam illumination 2.optical section through scar indicating scar is with in superficial layer of cornea. 17

Examination methods A- direct illumination : angle between the light source and microscope is about 30-50 and both microscope and light will direct to the focusing area, different type of direct illumination can be used 1- wide-beam direct illumination use to evaluate large area 2- parallelepiped it is constructed beam occur by narrowing the beam to 1-2 mm in width use for examined the layered of cornea and lens especially in the depth and extent of the corneal abrasions, scarring and foreign bodies 3- optic section it is when the parallelepiped reduced in width to an extremely thin, it is use for evaluated the layer of cornea and the depth of the foreign body 4- conical beam produce by narrowing the vertical height of a parallelepiped to produce a small circular or square spot of light, used to examined the transparency of the anterior chamber for floating cells 5- Specular reflection Established by separating the microscope and slit beam by equal angles from normal to cornea. Position of illuminator about 30 degree to one side and the microscope 30 degree to other side. Angle of illuminator to microscope must be equal and opposite. Angle of light should be moved until a very bright reflex obtained from corneal surface which is called zone of specular reflection. 18

Schematic of specular reflection. Reflection from front surface endothelium 19

Observe: Anterior and posterior cornea Iris is best viewed without dilation by this method. Anterior lens (especially useful for viewing pseudoexfolation). Indirect illumination The beam is focused in an area adjacent to ocular tissue to be observed. Main application: Examination of objects in direct vicinity of corneal areas of reduced transparency e,g, infiltrates,corneal scars,deposits,epithelial and stromal defects 20

Indirect illumination Illumination: Narrow to medium slit beam Decentred beam Magnification: approx. m=12x (depending upon object size 21

Retroillumination Formed by reflecting light of slit beam from a structure more posterior than the structure under observation. A vertical slit beam 1-4mm wide can be used. Purpose: Place object of regard against a bright background allowing object to appear dark or black. Used most often in searching for keratic precipitates and other debris on corneal endothelium. The crystalline lens can also be retroilluminated for viewing of water clefts and vacuoles of anterior lens and posterior subcapsular cataract Slitlamp photo shows keratic precipitates inside the eye. These opacities are collections of inflammatory cells that collect on the inner surface of the cornea. 22

Direct retroillumination from iris: Used to view corneal pathology. A moderately wide slit beam is aimed towards the iris directly behind the corneal anomaly. Use magnification of 16x to 25x and direct the light from 45 degree. Microscope is directed straight ahead. Schematic of direct retroillumination from the iris. direct retroillumination from the iris. 23

Sclerotic scatter It is formed by focusing a bright but narrow slit beam on the limbus and using microscope on low magnification. Such an illumination technique causes cornea to take on total internal reflection. The slit beam should be placed approximately 40-60 degree from the microscope. When properly positioned this technique will produce halo glow of light around the limbus as the light is transmitted around the cornea. Corneal changes or abnormalities can be visualized by reflecting the scattered light. Used to observe: Central corneal epithelial edema Corneal abrasions Corneal nebulae and maculae. Depending on the density of the abnormality, the light from behind may reflect through, allowing detailed examination of the internal structure of the pathology. Observe: corneal opacities (edema, infiltrates, vessels, foreign bodies), lens, iris 24

Procedure: - Patient will examined without glasses - Room illumination is dim - Adjust the height of the slit lamp table to the comfort position for patient and examiner - Instruct the patient to place his chin on chin rest and his forehead against forehead rest - Adjust the chin rest to align the patient canthus - Set the magnification in low setting,remove all filters - Open the both eyes of you ( examiner) and set the IPD - Use one hand to use the joystick and the other hand to control the angle between the microscope and light Fluorescein staining: Fluorescein is an orange colored dye, it is instilled into the eye and a fine film over the corneal surface, it will appear by using ultra violet light as green color, it use in detected F.B and corneal abrasion 25

Ocular structure Type of slit lamp beam Angle of illumination arm magnification Lids / lashes diffuse 30 low conjunctiva parallelepiped 30 low cornea Anterior chamber Angle depth aqueous Iris Lens Narrow 30-45 medium parallelepiped Optic section 60 medium Conical beam 30 high Wide parallelepiped Narrow parallelepiped 30-45 medium 20-30 medium 26

Eye Anatomy 27

Anterior segment disease evaluation Lids and lashes Conjunctiva and cornea Instillation of fluorescein and BUT measurement Anterior chamber Depth and angle measurement Iris Crystalline lens 28

29

30