sensicam em electron multiplication digital 12bit CCD camera system

Similar documents
pco.1600 cooled digital 14bit CCD camera system

sensicam qe cooled digital 12bit CCD camera system

pco.1300 solar cooled digital 12bit CCD camera system

pco.dimax digital high speed 12 bit CMOS camera system

hsfc pro 12 bit ultra speed intensified imaging

panda family ultra compact scmos cameras

edge 4.2 bi cooled scmos camera

: fps. pco.edge. 1.4 electrons. 5.5 megapixel. pco. high speed. high resolution. low noise. high dynamic range. scientific CMOS camera

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps : 1 > 70 % pco. low noise high resolution high speed high dynamic range

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range

pco.edge electrons 2048 x 1536 pixel 50 fps :1 > 60 % pco. low noise high resolution high speed high dynamic range

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps :1 > 70 % pco. low noise high resolution high speed high dynamic range

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range

pco.edge electrons 2048 x 2048 pixel 100 fps :1 > 70 % pco. low noise high resolution high speed high dynamic range

pco.dimax HS light sensitivity pco. high speed > Mpixel excellent

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

1469 fps. pco.dimax HD / HD+ ISO speed. color fidelity. HD 1920 x 1080 pixel HD x 1440 pixel. pco. high speed. excellent high.

pco.edge electrons 2560 x 2160 pixel 100 fps :1 > 60 % pco. low noise high resolution high speed high dynamic range

DV420 SPECTROSCOPY. issue 2 rev 1 page 1 of 5m. associated with LN2

pco.edge gold electrons 2048 x 2048 pixel -30 Celsius :1 > 70 % pco. low noise high resolution cooling down to high dynamic range

pco.edge electrons 2560 x 2160 pixel 100 fps :1 > 60 % pco. low noise high resolution high speed high dynamic range

DU-897 (back illuminated)

pco.edge electrons 2048 x 2048 pixel 100 fps :1 up to 82 % pco. low noise high resolution high speed high dynamic range

pco.edge electrons 2048 x 2048 pixel 100 fps :1 up to 82 % pco. low noise high resolution high speed high dynamic range

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available.

Upgrade to Andor s high-resolution Luca EM R EMCCD; the new price/performance benchmark.

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.

Fluorescence (Luminescence) Lifetime Imaging application simplified... with the pco.flim

Back-illuminated scientific CMOS camera. Datasheet

Optional AR coating and wedge windows are available

pco.dimax HD / HD+ ISO speed color fidelity pco. excellent highest high speed Full HD

ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View

PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels Direct detection

ixon NOW AVAILABLE WITH EX2 TECHNOLOGY New Specifications Summary 2 Active pixels 1024 x 1024 Active area pixel well depth 80,000 e -

ZEISS Axiocam 512 color Your 12 Megapixel Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution

OEM Low Cost CCD Cameras

Last class. This class. CCDs Fancy CCDs. Camera specs scmos

ABOUT RESOLUTION. pco.knowledge base

ixon Specifications Summary Active pixels 1024 x 1024 Active area pixel well depth 90,000 e - Gain register pixel well depth 730,000 e -

ixon ,000 1 x 1 Binning 14,000 12,000 Frame Rate (Frames/s) 10,000 4 x 4 Binning 8,000 2 x 2 Binning 6,000 4,000 2,000

400BSI V2.0. BSI Scientific CMOS Cooled Camera. 4 0 fps. 7 4 fps. 1.2 e % PRNU. 0.2 e μm 4.2 MP.

The new CMOS Tracking Camera used at the Zimmerwald Observatory

Applications for cameras with CMOS-, CCD- and InGaAssensors. Jürgen Bretschneider AVT, 2014

PIXIS-XO: 1024B 1024 x 1024 imaging array 13 x 13 µm pixels

Digital Cameras for Microscopy

PIXIS-XO: 1024B 1024 x 1024 imaging array 13 x 13 µm pixels

BSI scmos 400BSI. Super Signal to Noise Ratio NEW

X-Ray diffraction pattern of the Synchrotron Soleil,France. Courtesy of Vincent Jacques. Direct Detection X-Ray Imaging. Specifications Summary

The CCD-S3600-D(-UV) is a

Specifications Summary. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode. Maximum spectra per sec 1,612

The Condor 1 Foveon. Benefits Less artifacts More color detail Sharper around the edges Light weight solution

IPD3. Imaging Photon Detector APPLICATIONS KEY ATTRIBUTES

ikon-m 934 DO Series

AxioCam HR Success Through Performance

Lightning-Cam TM Camera

BaySpec SuperGamut OEM

Basler. Line Scan Cameras

MOTICAMPRO PROFESSIONAL CCD MICROSCOPY CAMERAS

Real-color High Sensitivity Scientific Camera

30 x 3.8 mm / 2000 x 256 pixel NIR Spectroscopy CCD. cooling. Specifications Summary. Active pixels 2000 x 256

TEM Cameras. Digital Cameras for Electron Microscopy

Real-color High Sensitivity Scientific Camera. For the first time with true color ISO9001

ULS24 Frequently Asked Questions

Welcome to: LMBR Imaging Workshop. Imaging Fundamentals Mike Meade, Photometrics

istar 712 Series Gen 3 - FL (HVS, -63) Gen 3 - FL (EVS, -A3) Gen 3 - FL (BGT, -C3) InGaAs (NIR, -93)

Data Sheet SMX-160 Series USB2.0 Cameras

NanEye GS NanEye GS Stereo. Camera System

Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS

Baumer FWX05c-II NeuroCheck Edition

WHITE PAPER. Sensor Comparison: Are All IMXs Equal? Contents. 1. The sensors in the Pregius series

e2v Launches New Onyx 1.3M for Premium Performance in Low Light Conditions

Baumer TXF50 Art. No: OD107988

Spectroscopy at Pace. Specifications Summary. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode

NEW. Spectroscopy at Pace. Specifications Summary 1. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

More Imaging Luc De Mey - CEO - CMOSIS SA

AxioCam MRc 5 A World of Digital Possibilities

Soft X-rays Hard X-rays. Specifications Summary. Active pixels 1024 x Pixel size (W x H) 13 x 13 µm

A 3MPixel Multi-Aperture Image Sensor with 0.7µm Pixels in 0.11µm CMOS

Cooled cameras for scientific applications and astronomy. Ian Alderton Alrad Imaging division of Alrad Instruments Ltd

Technical note EM-CCD CAMERA. 1. Introduction

CCD1600A Full Frame CCD Image Sensor x Element Image Area

ixon EM + Back-illuminated EMCCDs

The NIRDAPD TEC series photodetector is available in two different active area sizes: Key Features

BioSpectrum Imaging System

High Resolution BSI Scientific CMOS

OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

NOVA S12. Compact and versatile high performance camera system. 1-Megapixel CMOS Image Sensor: 1024 x 1024 pixels at 12,800fps

A 4 Megapixel camera with 6.5μm pixels, Prime BSI captures highly. event goes undetected.

Improved sensitivity high-definition interline CCD using the KODAK TRUESENSE Color Filter Pattern

idus 420 Series Specifications Summary 2 Register well depth (typical) 1,000,000 e - Maximum spectra per sec 88 Read noise As low as 4 e -

Time Delay Integration (TDI), The Answer to Demands for Increasing Frame Rate/Sensitivity? Craige Palmer Assistant Sales Manager

Sapphire FP. Fiber Pigtailed Lasers from Deep Blue to Orange FEATURES

idus 401 Series Specifications Summary Active pixels 1024 x 127 Register well depth (typical) 1,000,000 e - Maximum spectra per sec 88

UV-NIR LASER BEAM PROFILER

Automated Imaging Technology to Simplify Your Workflow!

Transcription:

sensicam em electron multiplication digital 12bit CCD camera system electron multiplication gain of up to 1000 superior resolution (1004 1002 pixel) for EMCCD extremely low noise < 1e excellent quantum efficiency of up to 65 % 12 bit dynamic range shutter / exposure times from 75 µs to 1 h thermo-electrical cooling of -45 C vs. ambient free software camware and software development kit included

sensicam em The new generation of electron multiplication CCD (emccd) sensors is integrated into a sensicam camera system. With this on-chip multiplication of the light signal the readout noise of the camera can be neglected (< 1 e rms @ gain > 50). With its excellent resolution of 1004 1002 pixel this high performance cooled digital 12 bit CCD camera system is best suited for extreme low light camera applications. The system features thermoelectrical cooling of the image sensor (down to -45 C vs. ambient) and an outstanding quantum efficiency (up to 65 %), which achieves a high spectral sensitivity in general and especially in the NIR. Exposure time modes (software selectable) range from 75 µs - 1 h. A high speed serial data link connects the system to the PC (fiber optic link available). This low light camera system is very well suited for scientific imaging (e.g. microscopy, bio marker and label imaging) and for night vision. technical data unit setpoint sensicam em resolution (hor ver) 1 pixel 1004 1002 pixel size (hor ver) µm² 8.0 8.0 sensor format / diagonal mm² / mm 8.03 8.02 / 11.35 peak quantum efficiency % @ 670 nm typical 65 full well capacity e 70 000 image sensor TC285SPD dynamic range db @ CCD + camera 72 dynamic range bit 12 A/D 2 readout noise e rms @ em gain = 2 @ em gain > 50 imaging frequency, frame rate 10 < 1 fps @ full frame 13 pixel scan rate MHz 16 A/D conversion factor e / count @ em gain = 2 6 spectral range nm 290..1100 exposure time s 75 µs..1 h anti-blooming factor typical 1000 smear % 0.6 binning horizontal pixel 1, 2, 4, 8 binning vertical pixel full resolution for 992 pixel ver 1, 2, 4, 8, 16, 32 dark current e / pixel s @ 15 C typical 0.9 region of interest pixel for 992 pixel ver down to 32 charge multiplication 9 steps 2, 5, 10.. 1000

technical data non linearity % full temperature range @ gain = 2 uniformity darkness e rms @ 90% center zone & DSNU 3 gain = 2 uniformity brightness % rms typical 0.6 PRNU 4 trigger, auxiliary signals internal / external software / TTL level power consumption W typical 36 power supply VAC 90..260 mechanical dimensions camera (w h l) mechanical dimensions power supply (w h l) < 2 mm³ 93 78 210 mm³ 84 50 155 weight kg 1.6 operating temperature range operating humidity range storage temperature range optical input optical input window C +5..+40 % 10..90 C -20..+70 2 c-mount, Nikon f-mount fused silica data interface PCI local bus, Rev. 2.1, burst rate 132 MByte/s CE certified cooled CCD temperature cooling method C versus ambient temperature yes Δ -45 5 2 stage Peltier cooler with forced air cooling [1] horizontal versus vertical [2] Analog-to-Digital-converter [3] dark signal non-uniformity [4] photo response non-uniformity [5] factory preset at -12 C for control margin

software options Camware software for camera control, image acquisition and archiving of images in various file formats, WindowsNT, 2K and XP, 32 bit-dynamic link library (DLL) is available for user customisation and integration on PC platforms (software development kit - SDK), software is operational in either single mode or with builtin recorder functions, drivers for popular third party software packages are available (see website) CCD image sensor in UV sensitive version custom-made versions frame rate table [frames per second] vertical resolution [pixel] vertical binning frame rate [fps] 1002 1 12.9 501 2 25.2 248 4 47.9 124 8 86.6 62 16 86.6 31 32 108.4 quantum efficiency (TC285SPD qe curves as measured by PCO AG)

areas of application laser induced fluorescence fluorescence microscopy electron microscopy Red and NIR fluorescence applications bioluminescence / chemoluminescence spectroscopy gel imaging ion imaging low light level imaging semiconductor quality control imaging of bio markers (e.g. green fluorescent protein, GFP) scientific imaging confocal microscopy night vision surveillance and security

contact The Cooke Corporation PCO AG 6930 Metroplex Drive Donaupark 11 Romulus, Michigan 48174 93309 Kelheim, Germany USA tel 248 276 8820 fon +49 (0)9441 2005 50 fax 248 276 8825 fax +49 (0)9441 2005 20 info@cookecorp.com info@pco.de www.cookecorp.com www.pco.de sensicam em product sheet 05/2005 subject to changes without prior notice PCO AG, Kelheim