E-STOP relays, safety gate monitors

Similar documents
Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

PNOZ X3. } Safety relays. Operating Manual EN-08

PNOZ X2.7P. } Safety relays. Operating Manual EN-19

02/11/2015

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

02/11/2015

Datasheet - PROTECT-IE-02

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Installation / Monitoring Technique

02/11/2015

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Electronic Circuit Breaker with reset input ESS20-1..

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Type CP-S, CP-C & CP-A Switch mode

Electronic Circuit Breaker ESS1 for System SVS1

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

Electronic Circuit Breaker ESS20-0..

Controls Contactors and Contactor Assemblies Special Applications

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

08/07/2015

Electronic Circuit Protector ESX10-T

38 Series - Relay Interface Modules A

PHOENIX CONTACT

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

08/07/2015

Protection components

05/09/2012

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

02/11/2015

3 - Protection components Circuit-breakers

RE17LLBM asymmetrical flashing relay s V AC - solid state output

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Technical features table for miniature circuit-breakers SH 200 Series

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

PHOENIX CONTACT

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

02/11/2015

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Measuring current transformers of the W, W series

Datasheet. Electronic Circuit Protection ESX10-T

PHOENIX CONTACT - 09/2009

Multi-function 11 pin Plug-in for use with 90 series sockets

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Measuring current transformers of the W AB(P) series

Solid-state Timer H3DS

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Electronic Circuit Breaker ESS1 for System SVS1

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

62 Series - Power relays 16 A. Features / /

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Subject to changes 11/2003 Page 1/7

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

MINI-PS AC/24DC/1.3

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Contactors and Contactor Assemblies

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Electronic timer CT-TGD.22

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Components for safety applications Preventa safety modules

FM series position switches

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Operating instructions Fail-safe delay timer AZS About this document. Content

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

38 Series - Relay interface modules A. Features /

Transformers, Power Supply Units and Socket Outlets

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

MINI-PS AC/2X15DC/1

Installation- / Monitoring Technique

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Safety Technique. SAFEMASTER Emergency Stop Module LG 5925

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Capacitor Switching Contactors

P RODUCT C ATALOGUE 1/2002

Safety switches with slotted hole lever

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Electronic timer CT-MFS.21

Transcription:

Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Connection options for: E-STOP pushbutton Safety gate limit switch Reset button Light barriers LED indicator for: Switch status channel 1/2 Supply voltage Plug-in connection terminals (either cage clamp terminal or screw terminal) See order reference for unit types Light barriers Safety features The relay meets the following safety requirements: The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. Block diagram Unit description The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with E-STOP pushbuttons Safety gates A1 A2 13 23 33 41 ~ = ( )* Input Input Input Reset/ Start K1 Power K2 14 24 34 42 *only with U B 24-240 VAC/DC

Function description Single-channel operation: no redundancy in the input circuit, earth faults in the reset and input circuit are detected. Dual-channel operation without detection of shorts across contacts: redundant input circuit, detects earth faults in the reset and input circuit, Timing diagram short circuits in the input circuit and, with a monitored reset, in the reset circuit too. Dual-channel operation with detection of shorts across contacts: redundant input circuit, detects earth faults in the reset and input circuit, short circuits and shorts between contacts in the input circuit. Automatic start: Unit is active once the input circuit has been closed. Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. Increase in the number of available contacts by connecting contact expander modules or external contactors/relays. 1 2 a b POWER Reset/Start Input Output safe Output aux. t1 t2 t1 t2 t1 t2 t1 t2 Key Power: Supply voltage Reset/start: Reset circuit - Input: Input circuits -, -, Output safe: Safety contacts 13-14, 23-24, 33-34, Wiring Please note: Information given in the Technical details must be followed. Outputs 13-14, 23-24, 33-34, are safety contacts, output 41-42 is an auxiliary contact (e.g. for display). To prevent contact welding, a fuse should be connected before the output contacts (see technical details). Calculation of the max. cable runs l max in the input circuit: Output aux: Auxiliary contacts 41-42 : Automatic reset : Manual reset a: Input circuit closes before reset circuit Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. b: Reset circuit closes before input circuit t 1 : Switch-on delay t 2 : Delay-on de-energisation I max = R lmax R l / km R lmax = max. overall cable resistance (see technical details) R l /km = cable resistance/km Use copper wire that can withstand 60/75 C. -2

Preparing for operation Supply voltage Supply voltage 24 240 V AC/DC 24 V AC/DC A1 A2 L1 N A1 L+ A2 L- Input circuit Input circuit Single-channel Dual-channel E-STOP without detection of shorts across contacts E-STOP with detection of shorts across contacts Safety gate without detection of shorts across contacts S2 Safety gate with detection of shorts across contacts S2 Light barrier with detection of shorts across contacts 24 V DC Gnd

Reset circuit Reset circuit E-STOP wiring (single-channel) Safety gate (single-channel) E-STOP wiring (dual-channel) Safety gate (dual-channel) Automatic reset Manual reset S3 S3 Feedback loop Feedback loop Automatic reset Manual reset Contacts from external contactors 13 (23,33) 14 (24,34) K5 K6 K5 K6 L1 N 13 (23, 33) 14 (24,34) K5 S3 K6 K5 K6 L1 N Key /S2 S3 E-STOP/safety gate switch Reset button Switch operated Gate open Gate closed -4

Terminal configuration A1 13 23 33 P1 41 42 P2 POWER CH.1 CH.2 13 23 33 41 18992 14 24 34 42 P2 P1 A2 14 24 34 Installation The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). Dimensions * with cage clamp terminals 121 (4.76") 94 (3.70") * 101 (3.98") 22,5 (0.88")

Notice This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit. Service life graph U B 24 VAC/DC D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 DC13: 24 V DC1: 24 V AC1: 230 V 0.1 AC15: 230 V 100 1000 10000 100000 D Schaltspielzahl x 10 3 E Número de ciclos x 10 3 GB Cycles x 10 3 I Numero dei cicli di commutazione x 10 3 F Nombre de manœvres x 10 3 NL Aantal schakelingen x 10 3 U B 24-240 VAC/DC D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 AC15: 230 V DC13: 24 V AC1: 230 V DC1: 24 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 GB Cycles x 10 3 F Nombre de manœvres x 10 3 E Número de ciclos x 10 3 I Numero dei cicli di commutazione x 10 3 NL Aantal schakelingen x 10 3 Technical details Electrical data Supply voltage Supply voltage U B AC/DC 24-240 V, 24 V Voltage tolerance -15 %/+10 % Power consumption at U B AC 4.0 VA Order no.: 777301, 787301 4.5 VA Order no.: 777302, 787302 Power consumption at U B DC 2.0 W Order no.: 777302, 787302 2.5 W Order no.: 777301, 787301 Frequency range AC 50-60 Hz Residual ripple DC 160 % Voltage and current at Input circuit DC: 24.0 V 25.0 ma Order no.: 777302, 787302 30.0 ma Order no.: 777301, 787301 Reset circuit DC: 24.0 V 50.0 ma Order no.: 777302, 787302 55.0 ma Order no.: 777301, 787301 Feedback loop DC: 24.0 V 50.0 ma Order no.: 777302, 787302 55.0 ma Order no.: 777301, 787301-6

Electrical data Number of output contacts Safety contacts (S) instantaneous: 3 Auxiliary contacts (N/C): 1 Category of output contacts in accordance with EN 954-1 Safety contacts (S) instantaneous: 4 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V I min : 0.01 A, I max : 6.0 A Order no.: 777302, 787302 8.0 A Order no.: 777301, 787301 P max : 1500 VA Order no.: 777302, 787302 2000 VA Order no.: 777301, 787301 Safety contacts: DC1 at 24 V I min : 0.01 A, I max : 6.0 A Order no.: 777302, 787302 8.0 A Order no.: 777301, 787301 P max : 150 W Order no.: 777302, 787302 200 W Order no.: 777301, 787301 Auxiliary contacts: AC1 at 240 V I min : 0.01 A, I max : 6.0 A Order no.: 777302, 787302 8.0 A Order no.: 777301, 787301 P max : 1500 VA Order no.: 777302, 787302 2000 VA Order no.: 777301, 787301 Auxiliary contacts: DC1 at 24 V I min : 0.01 A, I max : 6.0 A Order no.: 777302, 787302 8.0 A Order no.: 777301, 787301 P max : 150 W Order no.: 777302, 787302 200 W Order no.: 777301, 787301 Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I max : 3.0 A Order no.: 777302, 787302 6.0 A Order no.: 777301, 787301 Safety contacts: DC13 at24 V (6 cycles/min) I max : 4.0 A Order no.: 777302, 787302 5.0 A Order no.: 777301, 787301 Auxiliary contacts: AC15 at 230 V I max : 3.0 A Order no.: 777302, 787302 6.0 A Order no.: 777301, 787301 Auxiliary contacts: DC13 at24 V (6 cycles/min) I max : 4.0 A Order no.: 777302, 787302 5.0 A Order no.: 777301, 787301 Contact material AgCuNi + 0.2 µm Au External contact fuse protection (I K = 1 ka) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 10 A Order no.: 777301, 787301 6 A Order no.: 777302, 787302 Auxiliary contacts: 10 A Order no.: 777301, 787301 6 A Order no.: 777302, 787302 Blow-out fuse, slow Safety contacts: 4 A Order no.: 777302, 787302 6 A Order no.: 777301, 787301 Auxiliary contacts: 4 A Order no.: 777302, 787302 6 A Order no.: 777301, 787301 Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: 4 A Order no.: 777302, 787302 6 A Order no.: 777301, 787301 Auxiliary contacts: 4 A Order no.: 777302, 787302 6 A Order no.: 777301, 787301

Electrical data Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC 30 Ohm Order no.: 777301, 787301 45 Ohm Order no.: 777302, 787302 single-channel at U B AC 120 Ohm Order no.: 777301, 787301 45 Ohm Order no.: 777302, 787302 dual-channel without detect. of shorts across contacts at U B DC 45 Ohm Order no.: 777301, 787301 80 Ohm Order no.: 777302, 787302 dual-channel without detect. of shorts across contacts at U B AC 170 Ohm Order no.: 777301, 787301 80 Ohm Order no.: 777302, 787302 dual-channel with detect. of shorts across contacts at U B DC 15 Ohm dual-channel with detect. of shorts across contacts at U B AC 15 Ohm Order no.: 777302, 787302 25 Ohm Order no.: 777301, 787301 Times Switch-on delay with automatic reset typ. 250 ms Order no.: 777301, 787301 340 ms Order no.: 777302, 787302 with automatic reset max. 400 ms Order no.: 777302, 787302 450 ms Order no.: 777301, 787301 with automatic reset after power on typ. 250 ms Order no.: 777301, 787301 600 ms Order no.: 777302, 787302 with automatic reset after power on max. 450 ms Order no.: 777301, 787301 800 ms Order no.: 777302, 787302 with manual reset typ. 125 ms Order no.: 777301, 787301 180 ms Order no.: 777302, 787302 with manual reset max. 400 ms Order no.: 777302, 787302 450 ms Order no.: 777301, 787301 Delay-on de-energisation with E-STOP typ. 10 ms with E-STOP max. 20 ms Order no.: 777302, 787302 30 ms Order no.: 777301, 787301 with power failure typ. 40 ms Order no.: 777301, 787301 with power failure max. 60 ms Order no.: 777301, 787301 with power failure typ. U B AC/DC: 24 V Order no.: 777302, 787302 180 ms Order no.: 777302, 787302 with power failure max. U B AC/DC: 24 V Order no.: 777302, 230 ms Order no.: 777302, 787302 787302 with power failure typ. U B AC : 240 V 1,100 ms Order no.: 777302, 787302 with power failure max. U B AC : 240 V 1500 ms Order no.: 777302, 787302 Recovery time at max. switching frequency 1/s after E-STOP 50 ms after power failure 100 ms Order no.: 777301, 787301 250 ms Order no.: 777302, 787302 after power failure on universal power supply 1500 ms Order no.: 777302, 787302 Min. start pulse duration with a monitored reset with rising edge 30 ms Simultaneity, channel 1 and 2 Supply interruption before de-energisation 20 ms Environmental data EMC EN 60947-5-1, EN 61000-6-2, EN 61000-6-4 Vibration to EN 60068-2-6 Frequency 10-55 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78 Airgap creepage EN 60947-1 Order no.: 777301, 787301 VDE 0110-1 Order no.: 777302, 787302 Rated insulation voltage 250 V Order no.: 777301, 787301 Rated impulse withstand voltage 4.0 kv Order no.: 777301, 787301 Ambient temperature -10-55 C -8

Environmental data Storage temperature -40-85 C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20 Mechanical data Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0 Max. cross section of external conductors with screw terminals 1 core flexible 0.25-2.50 mm², 24-12 AWG Order no.: 777301, 777302 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.25-1.00 mm², 24-16 AWG Order no.: 777301, 777302 without crimp connectors or with TWIN crimp connectors 0.20-1.50 mm², 24-16 AWG Order no.: 777301, 777302 Torque setting with screw terminals 0.50 Nm Order no.: 777301, 777302 Max. cross section of external conductors with cage clamp terminals/spring-loaded terminals: Flexible without crimp connectors 0.20-1.50 mm², 24-16 AWG Order no.: 787301, 787302 Cage clamp terminals/spring-loaded terminals: Terminal points 2 Order no.: 787301, 787302 per connection Stripping length 8 mm Order no.: 787301, 787302 Dimensions Height 101.0 mm Order no.: 787301, 787302 94.0 mm Order no.: 777301, 777302 Width 22.5 mm Depth 121.0 mm Weight 185 g Order no.: 777301, 787301 205 g Order no.: 787302 210 g Order no.: 777302 The standards current on 2005-08 apply. Conventional thermal current Number of contacts I th (A) at U B DC I th (A) at U B AC 1 6.00 A Order no.: 777302, 787302 8.00 A Order no.: 777301, 787301 6.00 A Order no.: 777302, 787302 8.00 A Order no.: 777301, 787301 2 6.00 A 6.00 A 3 4.50 A Order no.: 777302, 787302 5.00 A Order no.: 777301, 787301 4.50 A Order no.: 777302, 787302 5.00 A Order no.: 777301, 787301 Order reference Type Features Terminals Order no. C 24 VAC 24 VDC Cage clamp terminals 787 301 24 VAC 24 VDC Screw terminals 777 301 C 24-240 VAC 24-240 VDC Cage clamp terminals 787 302 24-240 VAC 24-240 VDC Screw terminals 777 302