High Performance Current Transducer ITL 900-T = A

Similar documents
High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

Current Transducer CTSR 1-P = 1A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

Voltage transducer DVL 50

V P N. Voltage transducer DVM 4200 = 4200 V

= 1000 V. Voltage transducer DVC 1000-P V P N

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

V P N. Voltage transducer DVM 2000-B = 2000 V

= 600 V. Voltage transducer DVM 600 V PN

V P N. Voltage transducer DVL 1000 = 1000 V

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

The four pin one (J1) makes possible to supply the board and access to the output voltage easily. It has the following pin-out:

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

DS10000ULFS-10V/10kA

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

AUTOMOTIVE CURRENT SENSOR HC6H300-S

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

ULTRASTAB IHF Precision Current Transducer

ULTRASTAB I U Precision

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HSW S01

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

Residual Current Monitoring Unit RCMU101SN-4P16

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157

Current transducer FHS 40-P/SP600

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S0C

SPECIFICATION Item No.: T60404-P4640-X100

Residual Current Monitoring Unit RCMU101SN-4P16C

CMS2005 MagnetoResistive Current Sensor (I PN

SPECIFICATION Item no.: T60404-N4646-X764

I Pr I P I OUT R L. Applications. Standards

CMS2050 MagnetoResistive Current Sensor (I PN

AUTOMOTIVE CURRENT TRANSDUCER DHAB S/15

AUTOMOTIVE CURRENT TRANSDUCERS OPEN LOOP TECHNOLOGY

SPECIFICATION Item no.: T60404-N4646-X400

SPECIFICATION Item No.: T60404-P4640-X102

Sensors & Accessories

Current transducer FHS 40-P/SP600

SPECIFICATION Item no.: T60404-N4646-X975

Transcription:

High Performance Current Transducer ITL 900-T For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I PM = 0... 900 A Electrical data I PN Primary nominal rms current 400 A I PM Primary current, measuring range 0 ±900 A R M Measuring resistance R M min R M max with ±15 V @ ±900 A max 5 5 Ω @ ±800 A max 5 7.4 Ω @ ±700 A max 5 10.4 Ω @ ±500 A max 5 20 Ω @ ±265 A max 5 50 Ω I S Secondary current 0 ±600 ma I SN Secondary nominal rms current 266.6666 ma K N Conversion ratio 1 : 1500 U C Supply voltage (±5 %) ±15 V I C Current consumption 1) +15 V 280 +I S ma Accuracy - Dynamic performance data 15 V 45 +I S ma Typ Max ε L Linearity error @ T A = 10 C 50 F 50 C 122 F 2) 1 3 ppm I OE Electrical offset current + self magnetization + effect of earth magnetic field @ T A = 25 C 77 F 2) 10 20 ppm I OM Magnetic offset current in case of overload 3000 A @ T A = 25 C 77 F 2) and R M = 5 W - 20 ppm I OE Offset stability (4 hours) 2) - 0.5 ppm TCI OE Temperature coefficient of I OE (10 C 50 F 50 C 122 F ) 2) - 0.3 ppm/k ε G Sensitivity error @ T A = 25 C 77 F 2) 4 15 ppm General data T A Ambient operating temperature 10 +50 C 50 +122 F T S Ambient storage temperature 20 +85 C 4 +185 F R S Resistance of secondary winding @ T A = 50 C 13.1 Ω m Mass 1.5 kg Standards EN 50178: 1997 Features Closed loop (compensated) current transducer using an extremely accurate zero flux detector Electrostatic shield between primary and secondary circuit Can be synchronized with an external clock signal. Advantages Very high accuracy Excellent linearity Extremely low temperature drift Wide frequency bandwidth Negligible self-magnetization High immunity to external interference Current overload capability. Applications Feed back element in high performance gradient amplifiers for MRI Feed back element in precision current regulated devices. Application domain Industrial and Medical. Notes: 1) With external synchronization signal 2) All ppm figures refer to secondary measuring range 600 ma. N 97.C6.58.000.0 Page 1/6

Current Transducer ITL 900-T Insulation characteristics Between primary and secondary U b Rated insulation rms voltage, reinforced or basic insulation 650 V with IEC 61010-1 standards and following conditions - Over voltage category III - Pollution degree 2 U d Rms voltage for AC insulation test, 50 Hz, 1 min 5 kv Û W Impulse withstand voltage 1.2/50 µs 9.9 kv U b Rated insulation rms voltage, reinforced or basic insulation 800 V with EN 50178 standards and following conditions - Over voltage category III - Pollution degree 2 U d Rms voltage for AC insulation test, 50 Hz, 1 min 5 kv Û W Impulse withstand voltage 1.2/50 µs 9.9 kv d Cp Creepage distance 11 mm d CI Clearance 11 mm CTI Comparative tracking index (Group I) 600 V Between secondary and external synchronization SMA connector U b Rated insulation rms voltage, reinforced or basic insulation 100 V with IEC 61010-1 & EN 50178 standards and following conditions - Over voltage category III - Pollution degree 2 U d Rms voltage for AC insulation test, 50 Hz, 1 min 1.4 kv Û W Impulse withstand voltage 1.2/50 µs 2.5 kv d Cp Creepage distance 1.5 mm d CI Clearance 1.5 mm Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/6

Current Transducer ITL 900-T Output noise figures: @ 25 C 77 F Random noise rms: 0.125 Hz 1 Hz 1 Hz 10 Hz 12.5 Hz 45 Hz 55 Hz 100 Hz 95 Hz 1 khz 1 khz 10 khz 10 khz 30 khz < 10 µat rms < 15 µat rms < 15 µat rms < 12 µat rms < 15 µat rms < 5 µat rms < 5 µat rms Coherent noise: 50 Hz / 60 Hz < 50 µat rms Re-injected noise measured on 1 primary turn < 25 µv Dynamic performance data BW Frequency bandwidth for small signal 5 %, 32 A rms, R M = 5 Ω ( 1 db) DC 100 khz ( 3 db) DC > 200 khz di/dt di/dt accurately followed R M = 5 Ω > 100 A/µs t r Response time 1) to 90 % of I PN step < 0.5 µs PSRR Power supply rejection ratio R M = 5 Ω Frequency PSRR on + U C PSRR on U C 60 Hz 85 db 95 db 120 Hz 80 db 90 db 300 Hz 71 db 84 db 600 Hz 66 db 78 db 1000 Hz 64 db 75 db 2000 Hz 60 db 70 db 10 000 Hz 62 db 72 db PSRR = 20 Log V rippleon supply ( V measured on R 5 Ω 10 M = ) Note: 1) With a di/dt of 100 A/µs. Page 3/6

Current Transducer ITL 900-T Over current protection As soon as electrical saturation appears, the transducer switches from normal operation to over current mode. This electrical saturation is defined as 1.05 times the current range (I PM ) Under these conditions: the ouput (pin 6 of D-SUB-9 connector) of the transducer is short circuited to the 0 V inside the transducer (with the help of a relay contact). the contact (operation status) between pin 8 to 3 (of D-SUB-9 connector) switches off, this contact becomes open. the green LED (located on the cover plate of the transducer and related to operation status) switches off. The over current mode remains until the primary current decreases below the recovery current. The value of the recovery current is typically ±165 A (max 260 A, min 70 A). TO ENSURE PROPER OPERATION, THE MAXIMUM BURDEN RESISTOR ALLOWED IS 50 OHMS. (5 OHMS MINIMUM). Maximum measuring resistor Maxi measuring resistor 60 50 Maxi externally connected measuring resistor with respect to primary current 40 Ohms 30 20 10 0 0 50 100 150 200 250 265 300 350 400 450 500 550 600 650 700 750 800 850 900 Primary current [A] Page 4/6

Voltage across the maximum measuring resistor Voltage across the maximum measuring resistor 10 9 8 7 Miscellaneous Voltage that can be achieved across the externally connected maximum measuring resistor with respect to primary current 6 Voltage [V] 5 4 3 2 1 0 0 100 200 300 400 500 600 700 800 900 Primary current [A] Miscellaneous Bus bar free zone (from center) r 100 mm Disturbance by a dv/dt of 5000 V, 6000 V/µs < 100 ppm 1) Sensitivity to DC magnetic field 900 A @ 100 mm < 10 ppm 1) External synchronization signal: if needed, an external signal can be applied on the SMA connector. This signal consists in a square wave 0 to 5 V, 10 ma, 31.25 khz (±1 khz). Note: 1) All ppm figures refer to secondary measuring range 600 ma. Page 5/6

Dimensions ITL 900-T (in mm) Connection I P U C U C I s R M Connection Normal operation status (Pins 8 and 3): Normal operation means: - ±15 V present - zero detector is working - compensation current 105 % of I PM / K N The contacts of the related relay are closed under normal operation. Synchronization status (Pins 7 and 2) Synchronization means: working of ITL 900-T is synchronized with an external synchronization signal. Under this condition, the contacts of the relay are closed. Mechanical characteristics General tolerance Transducer fastening by busbar Primary connection ±0.5 mm 2 holes 9 mm 2 M8 steel screws Recommended fastening torque 4 N m Transducer fastening 2 M6 steel screws Recommended fastening torque 5 N m Connection of secondary on D-SUB-9, connector UNC 4-40 Connection of external synchronization signal on SMA connector Remarks I S is positive when I P flows in the direction of the arrow. Temperature of the primary conductor should not exceed 100 C (212 F). Page 6/6