FORCE LIMITATION WITH AUTOMATIC RETURN MECHANISM FOR RISK REDUCTION OF REHABILITATION ROBOTS. Noriyuki TEJIMA Ritsumeikan University, Kusatsu, Japan

Similar documents
Three DOF parallel link mechanism utilizing smooth impact drive mechanism

Development of Variable Rate Spring by Permanent Magnet with Flux Concentration Method

Five-fingered Robot Hand using Ultrasonic Motors and Elastic Elements *

Introduction of Research Activity in Mechanical Systems Design Laboratory (Takeda s Lab) in Tokyo Tech

Technical Cognitive Systems

Robot Joint Angle Control Based on Self Resonance Cancellation Using Double Encoders

Designing Better Industrial Robots with Adams Multibody Simulation Software

Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures

DEVELOPMENT OF OPTO-PNEUMATIC ON-OFF VALVE AND ITS APPLICATION TO POSITIONING

Small Occupancy Robotic Mechanisms for Endoscopic Surgery

MODELLING AND CHATTER CONTROL IN MILLING

HAND-SHAPED INTERFACE FOR INTUITIVE HUMAN- ROBOT COMMUNICATION THROUGH HAPTIC MEDIA

The project. General challenges and problems. Our subjects. The attachment and locomotion system

A Compliant Five-Bar, 2-Degree-of-Freedom Device with Coil-driven Haptic Control

Actuators, sensors and control architecture

New Arc-welding Robots

Impact sound insulation: Transient power input from the rubber ball on locally reacting mass-spring systems

FLL Coaches Clinic Chassis and Attachments. Patrick R. Michaud

Challenges of Precision Assembly with a Miniaturized Robot

EXPERIMENTAL ANALYSIS OF BOLT LOOSENING DYNAMICS CHARACTERISTIC IN A BEAM BY IMPACT TESTING

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Department of Robotics Ritsumeikan University

Biomimetic Design of Actuators, Sensors and Robots

Diagnosis and compensation of motion errors in NC machine tools by arbitrary shape contouring error measurement

Development of Running Robot Based on Charge Coupled Device

CONTROLLING THE OSCILLATIONS OF A SWINGING BELL BY USING THE DRIVING INDUCTION MOTOR AS A SENSOR

Evaluation of Five-finger Haptic Communication with Network Delay

Development of Wooden Portal Frame Structures with Improved Columns

Description of Potential Errors in Laser Thickness Measurement Systems

Experimental Study and Circuit Analysis Model of Lightning Isolation Transformer for Railway Signal System

ACTUATORS AND SENSORS. Joint actuating system. Servomotors. Sensors

Table 1 Merits and demerits of the two types of haptic devices

Synchronization Control Scheme for Hybrid Linear Actuator Based on One Common Position Sensor with Long Travel Range and Nanometer Resolution

Development of Shape-Variable Hand Unit for Quadruped Tracked Mobile Robot

Wearable Force Display Using a Particle Mechanical Constraint

n Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S.

PRO LIGNO Vol. 11 N pp

Development of Shock Acceleration Calibration Machine in NMIJ

Development of Drum CVT for a Wire-Driven Robot Hand

Selective Stimulation to Skin Receptors by Suction Pressure Control

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Proceedings of Meetings on Acoustics

2. Refraction and Reflection

Development of a Walking Support Robot with Velocity-based Mechanical Safety Devices*

MA3. Miniature Absolute Magnetic Shaft Encoder Page 1 of 8. Description. Order Using #MA3 starting at $36.00 per unit. Features

Device for production of prototype moulds by milling

SGL Series. Single Guide Linear Motor Stage. Zero cogging and backlash ironless linear motor actuator. High speed and high acceleration

Cable lead-out. Standard. Rear lead-out (Connecter used in models 58 and 65) Variation. Side lead-out is available. (Models 25, 32, and 40) Option

high, thin-walled buildings in glass and steel

Electronic Instrumentation and Measurements

Theme 2: The new paradigm in robotics safety

CHAPTER 6 CARBON NANOTUBE AND ITS RF APPLICATION

A NOVEL PASSIVE ROBOTIC TOOL INTERFACE

Берг АБ Тел. (495) , факс (495)

Biologically Inspired Robot Manipulator for New Applications in Automation Engineering

Highly efficient water heaters using magnetron effects

Double-track mobile robot for hazardous environment applications

Monopile as Part of Aeroelastic Wind Turbine Simulation Code

On Observer-based Passive Robust Impedance Control of a Robot Manipulator

Module 4 General Purpose Machine Tools. Version 2 ME, IIT Kharagpur

Installation and Connection Manual

Calibration of Hollow Operating Shaft Natural Frequency by Non-Contact Impulse Method

FEKO-Based Method for Electromagnetic Simulation of Carcass Wires Embedded in Vehicle Tires

TH450A-T TH550A-T THP550-T/TS3000

NONDESTRUCTIVE EVALUATION OF CLOSED CRACKS USING AN ULTRASONIC TRANSIT TIMING METHOD J. Takatsubo 1, H. Tsuda 1, B. Wang 1

Products for fixing to Steelwork and Decking

EFFECTS OF ACCELEROMETER MOUNTING METHODS ON QUALITY OF MEASURED FRF S

ON THE PERFORMANCE OF LINEAR AND ROTARY SERVO MOTORS IN SUB MICROMETRIC ACCURACY POSITIONING SYSTEMS

Adaptive Humanoid Robot Arm Motion Generation by Evolved Neural Controllers

Manual Rotation Stages

Batteryless wireless transmission system for electronic drum uses piezoelectric generator for play signal and power source

A H M 531 The Civil Engineering Center

Section Content. Power Turntable Manual Turntable Low Profile Manual Turntable Optional Equipment and Devices

Robot Sensors Introduction to Robotics Lecture Handout September 20, H. Harry Asada Massachusetts Institute of Technology

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

UKEMI: Falling Motion Control to Minimize Damage to Biped Humanoid Robot

INFLUENCE OF PILES ON LOAD- SETTLEMENT BEHAVIOUR OF RAFT FOUNDATION

2D Asymmetric Silicon Micro-Mirrors for Ranging Measurements

Title. Author(s) P. WULANDARI. Issue Date Doc URLhttp://hdl.handle.net/2115/ Type. Note. File Information AND ANALYTICAL METHODS

Instruction Manual for installing

New Long Stroke Vibration Shaker Design using Linear Motor Technology

A study of Vibration Analysis for Gearbox Casing Using Finite Element Analysis

Study of a Miniature Air Bearing Linear Stage System

Gear Noise Prediction in Automotive Transmissions

DEVELOPMENT OF STABILIZED AND HIGH SENSITIVE OPTICAL FI- BER ACOUSTIC EMISSION SYSTEM AND ITS APPLICATION

RPE Parallel Gripper- Electric Gripper Series

MAGNETIC LEVITATION SUSPENSION CONTROL SYSTEM FOR REACTION WHEEL

ISMCR2004. Abstract. 2. The mechanism of the master-slave arm of Telesar II. 1. Introduction. D21-Page 1

SYNCHRONOUS MACHINES

Equivalent Circuits for Repeater Antennas Used in Wireless Power Transfer via Magnetic Resonance Coupling

Design Guide. Original version of the design guide

FLL Robot Design Workshop

Peter Berkelman. ACHI/DigitalWorld

Module 7 : Design of Machine Foundations. Lecture 31 : Basics of soil dynamics [ Section 31.1: Introduction ]

A study of small sized quartz tuning fork using finite element analysis

Vibratory Feeder Bowl Analysis

STUDY AND ANALYSIS OF ANGULAR TORQUING OF ENGINE CYLINDER-HEAD BOLTS USING TORQUE-TO-YIELD BOLTS: A CASE STUDY

Wheeled Mobile Robot Obstacle Avoidance Using Compass and Ultrasonic

Universal Screwdriver

ROBOTICS ENG YOUSEF A. SHATNAWI INTRODUCTION

Transcription:

FORCE LIMITATION WITH AUTOMATIC RETURN MECHANISM FOR RISK REDUCTION OF REHABILITATION ROBOTS Noriyuki TEJIMA Ritsumeikan University, Kusatsu, Japan Abstract In this paper, a new mechanism to reduce the risk of rehabilitation robots contacting the human body is proposed. It was composed of a force limitation mechanism and a soft structure with anisotropic viscosity. A prototype was developed, and its basic features were experimentally evaluated. The size of the prototype was too big, but it was confirmed that the new mechanism had many advantages. It could avoid a stronger force than a threshold level would affect a person. As the arrangement of the mechanism was not restricted to the robotic joints, the effect of posture of a robot upon the limitation force was able to be reduced to a certain degree (although not entirely). And, because elastic energy was consumed in the return process, it would not resonate. Introduction Lately rehabilitation robots have become of general interest. However, there are very few reports on how to reduce the risk of rehabilitation robots hitting humans. Because robots are essentially dangerous, industrial robots must be used in isolation from human work spaces. Contrary to this, rehabilitation robots cannot be separated from human work spaces because of their purposes. As a basic solution to this problem, a new risk reduction strategy for rehabilitation robots must be formulated to prevent accidents. Solutions to this problem have been previously suggested. The method by which a robot stops by ultrasonic or beam sensor signals before contact with a human body is unreliable [1][2]. Losing dead angles of the sensing area is difficult in this method. It can be considered that this is an additional method for risk reduction. As another method, force sensors and torque sensors were suggested to detect contacts [3]. However, problems lie in low reliability caused by intolerability of electronic devices to electromagnetic noise. Soft mechanisms, such as soft arms, soft joints or soft covers, feature to reduce the peak of impulsive force [4]. However, no report has clarified the most suitable compliance values. If a soft system such as a whip is resonant, it may be dangerous. It is also a problem that a soft structure is deformed even by a weak force. As practical solutions for a simple system, force (or torque) limitation mechanisms and small power actuators are suggested [5]. However, deciding the limitation torque value for an articulated robot is a difficult planning problem

because of its complex relationship between torques and an external force. Every method has its merits and demerits. In the present situation where a proper countermeasure cannot be found, it is difficult to make the use of rehabilitation robots widespread. The purpose of this study was to develop a new risk reduction mechanism that combines the advantage of a soft structure and a force limitation mechanism. Design Rationale A new force limitation mechanism was proposed. A force limitation mechanism is rigid against weaker forces than a threshold, but it is activated to move or to slip by stronger forces. It can protect a user against excessive forces from a robot. However, previous force limitation mechanisms could not return by themselves after releasing forces. They were restricted to be arranged on joints of articulated robots because their return movements were produced by actuators that drove the joints. If force limitation mechanisms can automatically return after releasing force, it becomes possible freely to arrange them on any part of the robot arm. It will be easier to decide the limitation force value and it will lead to new possibilities for the force limitation mechanism accordingly. Careful consideration should be given to a mechanical impedance of the return mechanism; If viscosity is set low when the mechanism operates under excessive forces, rapid responses to excessive Magnets Spring Damper Figure 1 Structure of a prototype of a force limitation with automatic return mechanism. Table 1 Feature of the damper Damper Type Stroke Max. Load Speed(compress) Speed(extend) ADA510MTP 100mm 2000N 0.47m/s(500N) 0.03m/s(500N) forces will be available. On the other hand, high viscosity on the return will avoid the resonant problem. The mechanism should have anisotropic viscosity after all. Development A prototype of this mechanism was developed to confirm its features (see Figure 1). The total size was 400 mm in length and 200 mm in diameter. A commercial damper (Enidine ADA510MTP) with anisotropic viscosity was used. The viscosity of the damper in extension, which was adjustable, was set at the highest value. Features of the damper are shown in Table 1. Two types of mechanical spring for generating the

return movement were prepared: spring type I had a stiffness of 2900 N/m and was fixed with a pre-load of 58 N, and spring type II had a stiffness of 4900 N/m and was fixed with a pre-load of 98 N. Force limitation was realized by four or five magnets, each of which had an ideal holding force of 98 N with steel. The straight movement was supported by a ball bearing. Methods A total of four prototypes of two kinds of spring and two kinds of magnet were examined by static forces. Each prototype was rigid against weak forces, but was activated to move by strong forces. Results of the threshold force are shown in Table 2. The threshold force was adjustable by the magnets and the spring. However, the results obtained did not agree with the theoretical results. The standard deviations were so wide as to be 3%, but I think that they were permissible because the diversities of a human are wider. The factors affecting it could be friction, the dead load, the unbalanced load, the flatness and the quality of the steel. This will be improved by introduction of a stiffer bearing system. The travel of the mechanism was measured with a laser displacement sensor (Keyence LK-2500) when a force was given and released statically. The constant force for the experiment is shown in Table 3. Results A typical example of the results is shown Travel(mm) Table 2 Results of threshold force Magnets Spring type I Spring type II 4 229.1±7.4[N] 283.0±8.5[N] 5 318.6±9.6[N] 371.1±4.9[N] Table 3 Loads for travel measurement Magnets Spring type I Spring type II 4 230[N] 330[N] 5 330[N] 430[N] Travel(mm) 60 40 20 0-0.3 0 0.25 0.5 0.75 1 Time(sec) (a) Forward movement 20 0-2 0 2 4 6 8 10 Time(sec) (b) Return movement Figure 2 A typical result of travel measurement (five magnets and spring type I). in Figure 2. The results obtained agreed approximately with those expected. When the force was given, the mechanism was started immediately and it traveled 55 mm within 0.25 seconds.

On the other hand, the mechanism returned slowly after release. Time constants of the return were 3.4 seconds for spring type I and 2.4 seconds for spring type II, which were long enough to avoid resonance. On the last two or three millimeters of movement, the mechanism quickly returned by the magnetic force, but this would not be a disadvantage of the mechanism. The distance of the quick movement was determined by the force of the spring and the magnets. A two-dimensional application model by which a force is given to a robotic link with two moment limitations with automatic return mechanisms is shown in Figure 3. Although the prototype moved straight, a rotation type was used in the simulation. When the threshold moment at mechanism A is M Amax and one at B is M Bmax, the external force F is limited as follows: F M A max M B max and F l 1sinθ l 2 sin( θ + α) A typical result of the simulation is shown in Figure 4. The force is limited as the thick line by two mechanisms. Because the threshold force is finite at any angle, the contact force can be limited in a certain range independently of the posture of the robot. As the result of simulation, a free arrangement of the mechanism will bring various advantages. Discussion To be applied to rehabilitation robots, the Figure 3 A two-dimensional model of a robot arm with torque limitation mechanism. 0 1/4% 1/2% 3/4% % Angle of force (radian) Figure 4 Result of simulation of the model. mechanism should be reduced to a size of 50-100 mm and a threshold force of 50-100 N. However, I believe that I showed this new idea to be beneficial. Being miniaturized by developing a small damper would be possible instead of a commercial one in which viscosity was adjustable. The viscosity, the stiffness and the threshold force value should be considered for a rehabilitation robot experimentally. There will be a better arrangement than the simulation by using three or more moment limitation mechanisms. It is easy to expand to a three-dimensional model. It would also

be applicable to an anisotropic force limitation mechanism. Conclusion A prototype of a new mechanism to reduce the risk of a rehabilitation robot hitting the bodies was developed. It was confirmed that the new mechanism had many advantages, such as a flexible arrangement, and no resonance. Miniaturization and a way to determine parameters will be subjects for future study. Acknowledgments The author would like to acknowledge the assistance and efforts of Tuyoshi Itoh; I also wish to thank the New Industry Research Organization and the KEYENCE Co. Ltd. for their support. Safety Method to Achieve Human-Robot Cooperation by 7-D.O.F. MIA ARM - Utilization of Safety Cover and Motion Control -; Proc. 14th Conf. Robotic Soc. Japan, 227-228 (1996) (in Japanese) [5] T. Saito, N. Sugimoto: Basic Requirements and Construction for Safe Robots; Proc. ROBOMEC 95, 287-290(1995) (in Japanese) Author Address Noriyuki Tejima Dept. of Robotics, Ritsumeikan Univ. 1-1-1 Noji-higashi, Kusatsu, Shiga, 525-8577, Japan E-mail: tejima@se.ritsumei.ac.jp Phone: +81 (77) 561-2880 Fax: +81 (77) 561-2665 References [1] M. Kioi, S. Tadokoro, T. Takamori: A Study for Safety of Robot Environment; Proc. 6th Conf. Robotic Soc. Japan, 393-394(1988)(in Japanese) [2] H. Tsushima, R. Masuda: Distribution Problem of Proximity Sensors for Obstacle Detection; Proc. 10th Conf. Robotic Soc. Japan, 1021-1022(1992) (in Japanese) [3] K. Suita, Y. Yamada, N. Tsuchida, K. Imai: A study on the Detection of a Contact with a Human by a Compliance- Covered Robot with Direct Torque Detection Function ~In Case of 1 Link Robot; Proc. ROBOMEC 94, 897-902(1994) (in Japanese) [4] T. Morita, N. Honda, S. Sugano: