WIRELESS TRANSMITTER for ph and ORP

Similar documents
WIRELESS TRANSMITTER for ph and ORP

Model 6081-C. Product Data Sheet PDS C/rev.D July 2010 FEATURES AND APPLICATIONS

Wireless Transmitter for Contacting Conductivity

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

The Rosemount 848T Wireless Temperature Transmitter

Regulatory status for using RFID in the UHF spectrum 3 May 2006

1204 Reflected Wave Reduction Device

Brochure More information from

The compact test- disconnect terminal interface system for protection and secondary technology

Table of Contents Executive Summary 29

2018/2019 HCT Transition Period OFFICIAL COMPETITION RULES

Sure Cross Radio Certifications

Who Reads and Who Follows? What analytics tell us about the audience of academic blogging Chris Prosser Politics in

Monthly Summary of Troop Contribution to UN Operations

SmartPower Solutions. Product Data Sheet February , Rev AD

Industrial Wireless LAN Radio Country Approvals for IWLAN Devices

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

Features and Applications

TwO-wIRE TRANSmITTERS FOR ph, ORP, CONDUCTIvITy, OxygEN, OzONE, AND CHLORINE

User Manual for 24 GHz Blind-Spot Radar Sensor

stripax The professional stripping tool

BenchTop Extraction Arms with unbeatable flexibility

Through-beam ring sensors

Process Control HPP-25

Frame through-beam sensors

Installation Data Sheet

NFC Forum: The Evolution of a Consortium

ICC Rev May 2008 Original: English. Agreement. International Coffee Council 100th Session May 2008 London, England

WOODWORKING TECHNOLOGY IN EUROPE: HIGHLIGHTS European Federation of Woodworking Technology Manufacturers

BenchTop Extraction Arms with unbeatable flexibility

dii 4.0 Global Industry 4.0 Readiness Report 2016 Industry 4.0 Readiness Index

RECOVERED PAPER DATA

Remote participation in Question sessions Audio options VoIP

Annex A. Countries and country groupings

Process-Controller HPP-25

Rosemount 708 Wireless Acoustic Transmitter

PO01275C Tabor East Neighborhood Meeting. Monday, April 20, :30 PM 8:30 PM

LPR WIRELESS TRANSMITTER

Instruction Manual PN P/rev.H November Model 5081-P. Two-Wire ph/orp Transmitter

RFC1000-CE Cloud Relay. MadgeTech Cloud Services Data Logger Hub. Product User Guide

The PCT in Latin America: its Role and Future. Recent developments of the PCT system in Latin America AIPPI Forum Buenos Aires, October 11, 2009

Features : Clamping Spring disconnectable terminal for solid or stranded copper conductors 0,25 to 2,5mm² VOLTAGE RANGE

Avery Dennison ICS Performance Guarantee Sign Cut and Wrapping Films Durability Bulletin 2.0

Cisco ONS Metropolitan Dense Wavelength Division Multiplexing 100-GHz FlexLayer Filter Solution

Economic Outlook for 2016

The Story of Why. #Wave 7

Rosemount 702 Discrete Input Transmitter

NOTE BY THE TECHNICAL SECRETARIAT SCALE OF ASSESSMENTS FOR 2019

SLC Servo Control System (Cat. No HSRV)

Reciprocity: What's New?

MICROCOR WIRELESS TRANSMITTER

ER WIRELESS TRANSMITTER

NI sbrio-9632/9642 Verification Procedure

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

FA Wireless SS Terminals

Tobacco: World Markets and Trade

Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note.

R&S SMZ Frequency Multiplier Precise andadjustable output levels from 50 GHz to 110 GHz

ANALYSIS OF THE WORLD-WIDE LICENSING AND USAGE OF IMT SPECTRUM

MICROCOR ER WIRELESS TRANSMITTER

ER WIRELESS TRANSMITTER

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Standard Economy Country Name. Each Minute. Initial. Additional

Chem & Bio non-proliferation

WIPO Capacity Building Activities and Programs: Activities for Innovation Promotion and Technology Transfer

TECHNICAL PROFILES CATALOGUE 2016

Z-Wave Alliance Recommendation ZAD Z-Wave transceivers - Specification of spectrum related components

COMPACT-LINE. Transmitter for ph-value

Open-ended Working Group on Ageing Second working session

19 and 20 November November 2018 Original: ENGLISH DECISION SCALE OF ASSESSMENTS FOR 2019

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Date of information. 18,690, est.

Walkie Talkie APMP300. User manual

PROGRAM AT-A-GLANCE: PRINT ENGINES SPECIALIZATION EUROPE, MIDDLE EAST AND AFRICA

Cisco ONS Erbium Doped Fiber Amplifier

Understanding Knowledge Societies Report of UNDESA/DPADM. Measurement Aspects. Irene Tinagli Tunis, 17 Nov World Summit on Information Society


CORIAN SOLID SURFACE. The Latin-America 54 colour portfolio

International Market Research Reports (IMRR)

ENHANCED OPTICAL BOOSTER AMPLIFIER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

Rosemount 248 Wireless Temperature Transmitter

Tire Pressure Monitoring Systems and Remote/Passive Keyless Entry

Capital Street Business News Institutional Investors. FIG Media Corporation Institutional Investors

NGR. Guided Wave Radar Level Transmitter

Sense. When thinking of silence, I hear gentle tunes played by an ocean orchestra nearby.

Coriolis Massflowmeter

Economic and Social Council

Wireless Acoustic Transmitters Series XYR 5000, Model WN571 Specifications - Americas

UMTS Forum key messages for WRC 2007

SECTION A APPENDIX J - COST-OF-LIVING INDEXES: Page 1 of 20

INTERNATIONAL CIVIL AVIATION ORGANIZATION

Temperature Transmitters

Exterior 200. / exterior 200 led

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

Trouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL

Rosemount 648 Wireless Temperature Transmitter

1.5 GHz Active Probe TAP1500 Datasheet

Radial riveting technology

TECHNOLOGIES READY TO MOVE smart innovation for successful results DAL MASCHIO

Transcription:

Product Data Sheet PDS 71-6081/rev E July 2010 Model 6081-P WIRELESS TRANSMITTER for ph and ORP HIGH ACCURACY AND RELIABILITY for monitoring applications SELF-ORGANIZING NETWORK for high data reliability and network stability INDUSTRY LEADING WIRELESS SECURITY COMPATIBLE WITH 1420 WIRELESS GATEWAY and Emerson Process Management WirelessHART TM networks EASY TO READ two-line display with easy to use menus in six local languages WirelessHART 7 Digital Communications SMART Sensor Enabled CONTINUOUS DIAGNOSTICS monitor sensor performance and health FEATURES AND APPLICATIONS The Model 6081-P transmitter is ideal for monitoring applications, especially in hard-to-reach or costprohibitive locations. Model 6081-P measures ph and ORP and is compatible with most Rosemount Analytical ph and ORP sensors. The transmitter has a rugged, cast aluminum weatherproof and corrosionresistant enclosure (NEMA 4X). The transmitter includes a two-line 16-character display with simple and intuitive menu screens. Plain language prompts in six (6) local languages guide the user through the programming and calibration procedures. Model 6081 is compatible with non-preamp ph and ORP sensors and SMART ph sensors from Rosemount Analytical. Installation and start-up of the Model 6081-P wireless transmitter is simple. Just power the Model 6081-P and assign it to a wireless network with a Model 1420 Gateway. The unit will auto-locate the most efficient path to the host and will begin transmitting measurement data via 2.4 GHz wireless communications. The Self- Organizing Network ensures exceptional data reliability and network stability. All of Emerson Process Management s wireless devices employ Encryption, Authentication, Verification, Anti-Jamming and Key Management to ensure data transmission and security. Rosemount Analytical devices include intelligent power management to reduce power consumption and extend power module life while delivering highly reliable measurements with rich HART data and diagnostic information. HART digital communication allows access to AMS (Asset Management Solutions) for live process variables, useful diagnostics and troubleshooting information. SPECIFICATIONS - GENERAL Enclosure: Cast aluminum. NEMA 4X. Dimensions: 6.55 x 5.40 x 5.15 (166mm x 137mm x 131mm). Conduit Openings: 3/4 FNPT Ambient Temperature: 32 to 149 F (0 to 65 C) Storage Temperature: -4 to 158 F (-20 to 70 C) Relative Humidity: 0 to 95% (non-condensing) Weight/Shipping Weight: 7 lbs/8 lbs (3.2/3.6 kg) Digital Communications: HART 7 WirelessHART

WIRELESS SPECIFICATIONS Output: WirelessHART V7 Transmit Rate: User selectable, 1/sec. to 1/60 min (via 1420 Wireless Gateway or AMS) Measurement update rate: 1/sec. to 1/60 min Antenna: PBT/PC integrated omni-directional antenna Radio Frequency: 2.4 GHz DSSS Transmission distance - line of sight: about 600 ft (ideal RF conditions and power module condition) Power: Lithium thionyl chloride long life power module. Power module life (estimated): six years at update rate of once per minute at 25 C ambient. FUNCTIONAL SPECIFICATIONS ph Range: 0 to 14 ORP Range: -1400 to +1400mV Compatible with Rosemount Analytical SMART ph sensors SMART ph Sensors: Avoid buffer calibrations in the field. Use Rosemount Analytical SMART ph sensors to automatically calibrate the measurement loop when connected to Model 6081. Choose from a complete range of SMART ph sensors suited to most applications. Recommended Sensors for ph: All conventional ph sensors without a + preamps and SMART ph sensors from Rosemount Analytical are compatible. All SMART sensors contain a microchip which stores complete diagnostics, including slope, offset, glass impedance, reference impedance, and software version. Recommended sensors for ORP: All conventional ORP sensors. Calibrations/standardization: The following calibration methods are supported: - Two point calibration with Low and High buffer (ph only) - Two point calibration with Automatic Buffer recognition (ph only) - Single point standardization - Single point Temperature Adjustment - Automatic calibration upon live connection to RAI SMART ph sensors and upload of stored cal data to transmitter Automatic Temperature Compensation: External 3-wire Pt100 RTD or Pt1000 RTD located in the sensor, compensates the ph reading for temperature fluctuations. Compensation covers the range -10 to 150 C (14 to 302 F). Manual temperature compensation is also selectable. Accuracy: ±1 mv @ 25 C ±0.01 ph Repeatability: ±1 mv @ 25 C ±0.01 ph Information and Status: Information screens display faults and warnings, radio transmission status, network ID number, Power Module voltage, transmitter model, and software version. Diagnostics: The internal diagnostics can detect: RTD Failure Glass Low Failure Glass High Failure Broken Glass Fault Reference High Failure CPU Error High Temperature Warning Low Temperature Warning Glass Impedance High Warning Glass Impedance Low Warning Reference Impedance High Warning EEPROM Warning Sense Line Open Warning Factory Cal Warning Keyboard Warning Once a fault or warning is detected, the display will show a message describing the problem. Sensor Temperature Range: -10 to 150 C (PT100 and PT1000) Display: 2-line, 16 character display supports display of ph and mv units. Display shows temperature. Approvals: RFI/EMI: EN-61326 R & TTE Directive: EN301 489-1 V1.2 2002 EN 301 489-17: V1.4.1 2002 EN 60950-1: 2001 EN 300 328 V 1.6.1 (2004-11) HAZARDOUS LOCATION APPROVALS Intrinsic Safety (with appropriate safety barrier): Class I, Division 1, Groups A, B, C and D Class II, Div 1, Groups E, F and G; Class III T4 Tamb : -20 C to +65 C Non-Incendive: Class I, Division 2, Groups A, B, C and D; Dust Ignition Proof Class II, Division 2, Groups F and G NEMA 4/4X Enclosure T4 Tamb : -20 C to +65 C 2

ORDERING INFORMATION Model 6081-P measures ph and ORP and is compatible with most Rosemount Analytical ph and ORP sensors. The transmitter has a rugged, cast aluminum enclosure (NEMA 4X). The device transmits live process variables and useful diagnostics via HART 7 digital communications to a Model 1420 Wireless Gateway. The Emerson Process Management complete wireless solution implements a Self-Organizing Network for high data transmission reliability and state-of-the-industry wireless security using robust 2.4 GHz DSSS radio transmissions. Model 6081 is compatible with non-preamp ph and ORP sensors and SMART ph sensors from Rosemount Analytical. Model Description 6081 Wireless Transmitter (must be operated with Model 1420 Gateway with Burst Rate, Operating Frequency and Protocol Ordering option A3 Measurement Required Option P ph/orp Agency Approval Required Option 60 None Required 69 CSA Approved, Intrinsically Safe Spectrum Approval Required Option 101 United States, Canada and Modular Approval Countries 1 102 EU and Modular Approval Countries 2 103 Mexico 104 Singapore 105 China 106 Australia 107 India 108 Brazil 109 France 110 Argentina 111 Ecuador 112 Japan 113 Malaysia 114 Peru 115 Qatar 116 Russia 117 Saudi Arabia 118 South Africa 119 South Korea 120 Turkey 121 Venezuela 122 United Arab Emirates ACCESSORIES 23820-00 Pipe/Wall Mounting Bracket kit for the Model 6081, carbon steel, painted 00753-9220-0001 Power Module Note: One power module included in price of Model 6081, but not installed 1. Modular Approval Countries for code -101: Aruba, Bahamas, Barbados, Belize, Bolivia, Bosnia & Herzegovina, Chile, Columbia, Costa Rica, Dominican Republic, El Salvador, Guatemala, Honduras, Jamaica, Kyrgyzstan, Montenegro, Morocco, Netherlands Antilles, Nicaragua, Panama, Puerto Rico, Serbia, Trinidad & Tobago. 2. Modular Approval Countries for code -102: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden. Switzerland, and United Kingdom. 3

EMERSON S SMART WIRELESS SOLUTION SELF-ORGANIZING, ADAPTIVE MESH ROUTING No wireless expertise required, devices automatically find the best communication paths Network continuously monitors paths for degradation and repairs itself Adaptive behavior provides reliable, hands-off operation and simplifies network deployments, expansion and reconfiguration Supports both star and mesh topologies INDUSTRY STANDARD RADIO WTH CHANNEL SEQUENCING Standard IEEE 802.15.4 radios 2.4 GHz ISM band sliced into 16 radio-channels Continually steps through channels to avoid interference and increase reliability Direct Sequence Spread Spectrum (DSSS) technology delivers high reliability in challenging radio environment SELF-HEALING NETWORK If an obstruction is introduced into the mesh network, devices will automatically find the best alternate communication path. This alternate path will be created and the information will continue to flow. SEAMLESS INTEGRATION TO EXISTING HOSTS Transparent and seamless integration Same control system applications Gateways connect using industry protocols 4

Model 6081-P Rosemount Analytical ph Sensor compatibility Compatible with standard ph/orp non-preamp sensors General Purpose 3300HT 3300HTVP 3400HT 3400HTVP 3500 3500VP 396 396P 396PVP 396R 396RVP 396VP 397 398 398R 398RVP 398VP 381 381+ 399 399VP 385 385+ 389 389VP Triple Junction 3800 3800VP 3200HP 328A 370 371 372 TF396 Special Purpose Compatible with all SMART preamp ph sensors SMART ph sensors 3500-01-10-21 3500VP-01-10-21 SMART ph sensors with VP8 connection 396P-01 396VP-54, 396PVP, 396RVP 389-01 389VP 399-10 and 399-14 399VP-09 385+-02 398RVP 3300HTVP-10 3400HTVP-10 Rosemount Analytical s SMART sensors extend the capabilities of traditional ph sensors. SMART sensor technology allows automatic calibration of sensors. Calibration data is automatically transferred to Model 6081 upon live connection of the sensor. Advanced diagnostics are displayed to indicate sensor health and predict sensor life. 5

6 Wall Mounting Installation Model 6081. Use Pipe/Wall Mounting Bracket Kit, PN 23820-00 Note: PN 23820-00 mounting bracket kit includes mounting hardware for pipe mounting only. Wall mounting hardware to be provided by customer. Only use suitable fasteners and hardware to securely fasten the bracket and transmitter to the wall surface.

Pipe Mounting Installation Model 6081. Use Pipe/Wall Mounting Bracket Kit, PN 23820-00 7

The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. 8 Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2010