Grounding Complications

Similar documents
GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

Device Interconnection

Grounding Recommendations for On Site Power Systems

Grounding for Power Quality

Grounding and Bonding

ECE 528 Understanding Power Quality

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

Wiring of the Main Distribution Panelboard

Application Note # 5438

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Article 250 Grounding & Bonding

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

GROUNDING / POWER ISSUES ISWM UNIVERSITY 2015

A statistical survey of common-mode noise

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Preface...x Chapter 1 Electrical Fundamentals

American Electrical Institute

EMC of Power Converters

Experiment 1: Instrument Familiarization (8/28/06)

Superior Measurements with a PXI Differential Amplifier

ECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motor Transformers and Distribution Systems

Experiment 1: Instrument Familiarization

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

Grounding Systems and Their Implementation By: Charles Atkinson Canadian Broadcasting Corporation Toronto, Canada

SureTest Model ST-1THD & ST-1THDC Instructions

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Course Introduction. Content: 19 pages 3 questions. Learning Time: 30 minutes

Wisconsin Contractors Institute Continuing Education

Realisation of the galvanic isolation in customer-end DC to AC inverters for the LVDC distribution

Measurement and Analysis for Switchmode Power Design

Categorized by the type of core on which inductors are wound:

Comparison of IC Conducted Emission Measurement Methods

Fluke Clamp Meters Solutions for every need

Chapter 3 G rounding Grounding Electromagnetic Compatibility Compatibility Engineering by Henry W Ott.

GROUNDING. What is it? Al Lewey K7ABL. Disclaimer

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

Experiment 5: Grounding and Shielding

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

Grounding and Bonding of Service Equipment

Technology in Balance

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

Switched Mode Power Supply Measurements

EMC review for Belle II (Grounding & shielding plans) PXD DEPFET system

80i-110s AC/DC CURRENT PROBE

BEST BMET CBET STUDY GUIDE MODULE ONE

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

SENSOR AND MEASUREMENT EXPERIMENTS

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

AIM & THURLBY THANDAR INSTRUMENTS

Overview of the ATLAS Electromagnetic Compatibility Policy

Part VI: Requirements for Integrated Services Digital Network Terminal Equipment

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

TEST REPORT... 1 CONTENT...

G.F.C.I. by Sam Goldwasser -- exerpts from: Sci.Electronics.Repair FAQ:

FTTH ENGINEERING AND INSTALLATION INTRODUCTION

2-Slot Desktop Chassis (DC) Extended Temperature

Debugging EMI Using a Digital Oscilloscope. Dave Rishavy Product Manager - Oscilloscopes

Surge Coupling Decoupling Network (S-CDN) Considerations

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

CONTINUING EDUC ATION

NEC 2014 Code Changes

Experiment 4: Grounding and Shielding

CS101. Conducted Susceptibility CS101. CS101 Maximum Current. CS101 Limits. Basis For CS101 Limits. Comparison To MIL-STD Vdc or Less

EMI Filters Demystified. By William R. Bill Limburg February 21, 2018 Phoenix Chapter, IEEE EMC Society

Emerging Standards for EMC Emissions & Immunity

Solution of EMI Problems from Operation of Variable-Frequency Drives

Top Ten EMC Problems

VLSI is scaling faster than number of interface pins

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Telecommunication Wiring Questions

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment)

Exam Booklet. Pulse Circuits

Alternating Current Power

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

Power Processor - Series 700F 10KVA to 150KVA

Signal and Noise Measurement Techniques Using Magnetic Field Probes

Busbars and lines are important elements

The Discussion of this exercise covers the following points:

Practical Measurements considerations for GaN and SiC technologies ANDREA VINCI EMEA MARKET DEVELOPMENT MANAGER POWER ELECTRONICS

Internal Model of X2Y Chip Technology

Schlöder GmbH - EMC Test and Measurement Systems Model #

Need for grounding Codes and Standards for grounding Wind Turbine Generator grounding design Foundation + Horizontal Electrode grounding design

LFR: flexible, clip-around current probe for use in power measurements

Charge-Sensing Particle Detector PN 2-CB-CDB-PCB

AC LAB ECE-D ecestudy.wordpress.com

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Decoupling capacitor placement

WHY YOU NEED A CURRENT BALUN

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

Data Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050

User s Manual for Integrator Short Pulse ISP16 10JUN2016

2. Determine the number of Modules/Microinverters required. (1134 modules is 2 less than 250 KW but works well with max comm.

Suppression of Powerline Noise with Isolation Transformers

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Magnetic field measurements, Helmholtz pairs, and magnetic induction.

Transcription:

Grounding Complications Sensitive Equipment Isolated grounding Supplemental grounds Sensitive Electronic Equipment NEC 647 [2002-2005] Originally intended for audio studios -- now Industrial/commercial applications Requirements Separately derived system 2 pole breakers 2.5% & 1.5% feeder/branch circuit voltage drop All 15 & 20 amps circuits must be GFCI protected Ground bus label -- Technical Power IG receptacles allowed Three phase applications require the use of 6 phase transformers 1

Isolated Grounding (IG) Isolated grounding receptacles NEC 250-74 Exception No. 4 [1996] NEC 250-146(d) [1999-2005] Isolated equipment grounding NEC 250-75 [1996] & NEC 250-96(b) [1999-2005] Isolated grounding passing through panelboards NEC 384-20 [1996 & 1999] & NEC 408.20 [2002-2005] Grounding must terminate within the derived service IG vs Regular Receptacle IG Receptacle Regular Receptacle NEUTRAL GROUNDED CONDUCTOR SILVER SCREW HOT UNGROUNDED CONDUCTOR BRONZE SCREW NEUTRAL GROUNDED CONDUCTOR SILVER SCREW HOT UNGROUNDED CONDUCTOR BRONZE SCREW EQUIPMENT RECEPTACLE GROUND GROUND GROUNDING CONDUCTOR GREEN SCREW GROUND GROUNDING CONDUCTOR GREEN SCREW 2

IG Application (1) IG Normal application -- IG passes back through panels to service origin. Grounding wire size must increase to match ampacity of panels it passes through. IG Application (2) IG must terminate at the derived service. Stepdown transformer is the derived service, not the main electrical entrance. 3

IG Position Reality Check Normal distribution wiring spreads incoming signals across many circuits. IG circuit extending back to service entrance assures larger signals at "protected" load. IG Circuit Coupling -V = L(di/dt) -- mutual inductance Functions as a 1:1 transformer IG use may contribute to "ground loops" IG #1 GROUND LOOP DATA CABLE IG #2 4

IG Circuit Induced Voltage Chassis voltage and data cable current Phase current & induced chassis voltage IG Ground Referenced Oscillation 5

Common IG Error (1) NEC violations IG run separately from current carrying conductors IG does not terminate at the derived service Common IG Error (2) NEC violations IG grounding is separate from facility grounding. Supplemental grounding at IG cannot serve as the sole grounding 6

Isolated Ground Path Problem Common mode voltage propagation - Source is equipment leakage current due to an overloaded EMI/RFI power supply filter. Effects include lockup, reset & blown serial ports. 12KV 480/277 208/120 Equipment CMI E=IZ E=IZ V=IR E=IZ CMI Isolated Grounding Effects Destructive Common mode voltage Voltages develop across I/O circuits 7

Supplementary Grounding (1) Use is permitted NEC 250-91(c) [1996] & NEC 250-54 [1999 & 2002] Earth is not an effective grounding means and cannot be the sole grounding means as specified in 250.4(A) and 250.4(B)(4) Supplemental grounding need not meet the electrode grounding provisions of NEC 250.50 or 250.53(C) Equipment must still be effectively grounded 250-51 [1996] & 250-2 [1999] & 250.136 [2002-2005] Supplementary Grounding (2) Supplementary grounding provides a path for external ground referenced interference to enter a facility Avoid use if at all possible H H High Low N Voltage Voltage N Equipment G 8

Supplementary Grounding Solutions Re-derive & Rereference Bond to facility reference DC Grounding 9

DC Grounding Connections NEC 250.162(A) [2005] Two wire, direct-current systems Operating voltage greater than 50V but less than 300V shall be grounded NEC 250.162(B) [2005] Three wire, direct-current systems The neutral shall be grounded NEC 250.164 [2005] Point of connection for direct-current systems Grounding must occur at the first system disconnecting means and not at individual services or at any point of use in the premises wiring Isolated Vs Contiguous Grounding A = Isolated grounding DC return grounded independently Voltage differential possible between AC power and dc system B = Contiguous grounding DC bonded to ac grounding means DC grounding run with ac conductors 10

Separate DC Grounding Conductor DC grounding tied to main facilty grounding DC grounding conductor run independent of ac conductors Attempt to prevent cross-talk between ac and dc conductors Multiple DC Reference Extra dc reference points turns grounding into a dc path DC current flows everywhere (inversely proportional to the dc resistance values). 11

DC Systems and SRG Provides an installation consistent with the IEEE Emerald Book Sources of Unwanted Ground Current 12

Ground Current Due To Utility Distribution Stray Current Open Neutral Interconnected utility neutral and communications grounding Coupling to communications circuits Stray Current HOT NEUTRAL SUB STATION HOUSE 1 BOND WATER PIPE WATER MAIN HOUSE 2 WATER PIPE BOND 13

Open Neutral X HOT NEUTRAL OPEN NEUTRAL SUB STATION WATER PIPE WATER PIPE BOND TO WATER PIPE BOND TO WATER PIPE HOUSE 1 HOUSE 2 WATER MAIN Interconnected Utility Neutrals H High Voltage Low Voltage H N G High Voltage Low Voltage Interconnected Neutral Telco & CATV 14

Utility Transformers L/G Primary L/L Primary Ground Current Due to Facility Distribution N/G Bonds N/G Reversal Multiple Neutral cross service of separately derived sources Induced Currents 15

Neutral/Ground Bonds LEGEND: Load Current Neutral Return Current EGC = Equipment Grunding Conductor A 1 Sub-panel EGC Utilization Equipment Data Link Lne Neutral B D 2 N-G Bond C Eqpt Grounding Conductor Panelboard F E Earth Ground (Main Building Electrical Ground) "Isolated" Ground, Ground Rod, Cold-Water- Pipe Ground, etc. End User Solution to Ground Loops Disconnected N/G bond at power distribution unit Violates code Safety hazard Performance problem Certainly not the correct solution to a problem 16

Neutral and Ground Problems Crossed neutrals N/G reversal AC #1 Load #1 Load AC #2 Load #2 Grounding Conductors & Current Grounded conductor problem Induced current due to grounded conductor placement Phase A Phase B Phase C 17

Tracing Ground Currents Zero Sum Measurements H N 18

Compare Sum & Neutral Summing Bus Bars 19

Checking Branch Circuits Check Transformers N/G bond is the ground fault return point Current patterns help ID sources 20

AC Gaussmeter Measures flux density Milligauss & MicroTeslas Problems arising from flux density CRT waver Induced current flow in data cables Great tool to ID ground loops Easy to use Single axis vs triaxial Interference & Ground Loop Measurements 21

Digital Storage Oscilloscope Digitizing rate -- 100MS/s & higher Bandwidth -- 100MHz & higher Vertical resolution -- 8 bit or better Single channel triggering Some scopes may have or-gate triggering on multiple channels Single ended signal acquisition Differential measurements require multiple channels or external devices. Extended monitoring capabilities Metratek software Stores triggered waveforms & rearms scope DFT of acquired waveforms High Frequency Measurements Everything grounded - interference voltages are small - difficult to distinguish from normal equipment operating noise. Currents much larger, easier to measure Couple using high-frequency transformer Digital storage oscilloscope and spectrum analyzer 22

Conventional Current Transformers Fluke, AEMC Multiple ranges 1mV/A 10mV/A 100mV/A Voltage output versus current output Rogowski Coils Fluke Instruments AEMC Switch selectable ranges 30, 300, 3000 600,6000 Output Voltage signal 23

Hall Effect Current Probes AEMC, Fluke May have multiple ranges Provides a proportional voltage output for DC currents AC currents can also be recorded Requires zero adjustment Calibration required Line Decouplers Oneac, PowerVAR Depending upon model may have L/N low frequency output High frequency L/N and/or N/G output Bandwidth typically from khz to low MHz Isolates scope from measurement point Converts single ended input into differential 24

High Frequency CTs Commercial products Manufacturers EMCO, Tegam, Fischer Custom Communications, Amplifier Research Intended use 50 Ohm interface Scopes & spectrum analyzers Range 100kHz to 100MHz 1MHz to 1GHz Plate Antenna Construction Metal top and bottom Plastic sides Probe 10MegOhm 10x Total capacitance 35pF Intended use Digital storage scopes Record radiated signals, cable potentials, floor potentials 25

Commercial Loop Antenna Manufacturers EMCO, Antenna Research Frequency range depends upon model Ferrite Rod Antennas Construction 6" ferrite rod 100 turns of 24 gauge telephone type wire BNC fitting Termination provided by scope Frequency range 50/60Hz to low khz 26

Conclusion Grounding Items to Avoid Supplementary grounding at equipment Parallel to service entrance grounding Conduit killers No grounding wire loose connections Needless IG use Grounding bypass of separately derived source Grounding "antennas Daisy chain grounding wires in workstation clusters Lift or defeat data cable shielding of disconnect pin 7 for RS-232-C N/G bond removal at transformers to stop ground loops Avoid grounding differentials within facilities Control interference at point of origin 27

Grounding Do's Augment service entrance grounding when needed Match the surroundings Ensure grounding at wye-to-wye service transformers Ensure grounding for padmount transformers inside facilities Use parity grounding for branch circuits Integrate facility grounding into a "Grounding electrode system Remember Kirchoff's laws Use Faraday concept for facility grounding Employ reference grids in raised floor environments Concluding Statements Current Flows in Paths - Kirchoff's Laws Prevail Ground is a path - not a terminus - and understanding the paths is the key to good grounding Interference can compromise good grounding if something looks ugly fix it! Electrical Codes cannot be compromised by grounding practices 28