SERIES 70 ELECTRIC ACTUATORS THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

Similar documents
SERIES 70 ELECTRIC ACTUATORS

Series 70 24V and 120V Actuator 600 to 18,000 lb.-in.

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Multi-turn Actuators ET RANGE

AWWA. Electric Actuators WE Series Weatherproof CSA Approved TYPE 4 & 4X ,900 in-lbs. torque C CONTROLS

BFS / BFSM SERIES Installation & Maintenance Manual

WE Series FEATURES OPTION CONFIGURATION STANDARD CONFIGURATION

Industrial actuation made easy

Valves with a difference. Electrical Actuators DVC INTERNATIONAL

ELECTRIC ACTUATOR. Quarter turn(rotary type) - ZGQ Series

FEATURES OPTIONAL FEATURES

AE SERIES ACTUATORS 2016 EDITION. The Best Way To Automate Your Process. Modulating Capable. Extended Duty Cycle Models Fast Acting Models

LA-5000 SERIES LINEAR VALVE ACTUATORS

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Electric Actuator. of innovated design. Introducing KIMAX CONTROLS INC. > Patented switch of manual & Motor operation. Clutchless manualoverride.

VALVCON V-SERIES ACTUATOR 115VAC AND 230VAC

Value Valves USA. Electric Actuator DOUBLE ACTING SPRING RETURN.

AE SERIES ACTUATORS. Electric Actuators. Standard Voltages 110/240/380/480V 24VAC/24VDC. Modulating Capable. 100% Duty Cycle Models Fast Acting Models

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

Worcester Controls PB SMART PRODUCTS

Spring Return DuraDrive Proportional Actuator

NEXUS NX50-1, -2 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION

AWWA. Electric Actuators C XC Series CSA Explosion Proof CSA Approved TYPE 4, 4X, 6 & 7 IP67

Explosion proof rotary actuator - On/Off or programmable regulating actuator

ELECTRIC ACTUATORS CONTROLS

VALVCON V Series Actuator. 115VAC and 230VAC

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

658 Current to Position Converters

Economic Style Electric Actuator. ITQ Series

P2/3 LV Series On/Off/Jog / Proportional

Compact Electric Actuator. JFEW Series

Non-Spring Return DuraDrive Modulating Actuator

P25 Medium Heavy Duty Side Mount Pan/Tilt Unit

Series E2000P. Electrical linear actuator. Features SPECIFICATION. Valve Division Wörth am Main. A. Hock MSR- und Electronic Service GmbH

Non-Spring Return EconoDrive Proportional Actuator

ELECTRONIC ROTARY GEAR MOTOR SERIES SED (AR2...SE )

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Technical Instructions Document No EA GQD June 23, OpenAir

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

Section 11 Electronic Position Controls & Encoders

DCS-62 Series Spring Return Electronic Actuator Product Bulletin

Options & Accessories

PF/PFQ. High Amperage plug and receptacle. Main Advantages

Dynamo Brushless DC Motor and GreenDriveTM Manual

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

Options & Accessories

Compact Motorized Actuator

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

OPERATION MANUAL. Linear Valve Actuator. Electrical Valve Actuator. September, nd

MV1000 MEDIUM VOLTAGE AC DRIVE 175 HP TO 16,000 HP

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

AWWA. Electric Actuators C XC Series CSA Explosion Proof CSA Approved TYPE 4, 4X, 6 & 7 IP67

847H. Description. Features. Specifications

Installation and Maintenance Manual HQ Release: February HQ Proportional Control Unit (PCU-A)

AD-8100 & AD-8200 Servo Amplifiers

ICM/ICAD Motorized Valve. Quick Start Guide. Installation, Programming, and Trouble-shooting REFRIGERATION & AIR-CONDITIONING

M4 Hex Nut [ ] M4 T-Nut 20 [20-044] Appx. 1. 3mm. 20 Series profiles (1 per hole) (1 per hole) Ordering Information

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

AC 01.2 HART Technical data Actuator controls

Zero Speed Switch. Instruction Manual PL-363 June Siemens Rev 2.6

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Digital Interface Card DEC005000

PART # mA Positioner

Dialight LED Obstruction. Technical Specification Sheet - Medium Intensity Red

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Rotary Measurement Technology Incremental Encoders

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

INSTRUCTION MANUAL (ATEX / IECEx)

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

Fisher 4200 Series Electronic Position Transmitters

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

5570M Series Intercom Installation and Operation Guide

+GF+ SIGNET Temperature Transmitter Instructions

Compact Motorized Actuator

Fisher 667 Diaphragm Actuators Size 80 and 100

AC 01.2 Modbus TCP/IP

FP-DO-400 and cfp-do-400

Process Control HPP-25

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

Section Heavy Duty Slide Gates Tender No. [ ] Page 1

Glim Cube iguzzini. design Piero Castiglioni SPECIFIC LIGHTING EFFECT LUMINAIRES. Easy maintenance (lamps have longer life)

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

Features. Continuous Duty Cycle Actuators

Fireye. NEXUS FX04 and FX04-1 Servo Motor Installation DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

Electric actuator for quarter-turn valves. For output torques to 17,700 lb. in.

Transcription:

SERIES 70 ELECTRIC ACTUATORS BRAY.COM THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS 1

1 Enclosure The low profile weatherproof enclosure is UL listed Type 4, 4x and IP65. Polyester powder coated die-cast aluminum cover and base, for exceptional corrosion, wear, impact and ultraviolet resistance. 2 High Visibility Position Indicator Prominently labeled and color coded yellow for open, red for close the display indicates valve position through the full range of travel. The O ring sealed dome is made of high impact, heat, chemical and ultraviolet resistant clear polycarbonate and designed to withstand caustic wash down ensuring excellent corrosion protection. 3 Captive Cover Bolts The cover is attached to the base by captive stainless steel bolts placed outside the sealing area. 4 O-Ring Seal For Watertight Enclosure The O-ring seal between the cover and base provides a weatherproof seal preventing internal corrosion. 5 Manual Override Standard on all models. The declutchable manual override prevents handwheel movement during motor operation. When manual operation is desired, pull the handwheel out to expose the yellow stripe around the handwheel shaft, which indicates the handwheel is engaged and manual operation is available. 6 Manual Override Switch Interrupts power to the motor when handwheel operation is engaged. 7 Conduit Entries Two connections in either NPT or metric threads. One entry is for power, the other for control wiring. 8 Motor Gear High torque start motor assembly, designed for fast inspection and maintenance. 9 Output Drive Self-locking worm shaft and worm gear assembly holds the valve in desired position. 10 Mechanical Travel Stop Bolts Designed to prevent over-travel in the open or close direction during manual operation. Travel stop bolts include a locknut to prevent loosening, seals to prevent water ingress, and spacers to prevent adjustment between 0 and 90 limit switch settings. Travel stop bolts permit 5 of over travel. 11 Terminal Strip Actuator limit switches are pre-wired to an easily accessible and clearly marked terminal block for customer wiring. The terminal strip has been placed near the two conduit entries with ample room for running wire leads. An easily accessible green plated ground screw is provided. A wiring diagram is included inside the cover for easy reference. 12 Limit Switch Bracket Simple and secure design to firmly hold limit switch assemblies for accurate and repeatable valve position feedback. 13 Limit Switch CAMs Bray s patented CAM design includes standard green (open) and red (close) CAMs which are adjustable with finger touch or screwdriver. No additional tools necessary. Standard factory setting allows 90 travel between open and close positions. 14 Roller Bearing Provides low friction while securely aligning actuator indicator shaft and CAMs for reliable valve position feedback. 14 15 Oldham Coupler Corrects any misalignment between the valve and actuator without introducing side load to the position indicator shaft assembly. 16 Standard Actuator Control Interposing Relay Board (I.R.B.) 120/220 VAC 50/60Hz On/Off control 15 17 Optional Actuator Controls Servo NXT Modulating Controller 120, 220, 24 VAC 50/60 Hz, 1 phase 24 VDC 24V On/Off Controller (not shown) 2 BRAY.COM

FEATURES 1 2 17 3 13 6 12 4 9 10 5 16 11 8 7 BRAY SERIES 70 ELECTRIC ACTUATORS 3

BENEFITS Hazardous Location Bray s Series 70 electric actuator has many advantages over other actuators including: Voltages: 120, 220, 24VAC 50/60 Hz, 1-phase, 24VDC Output torque 300 lb-in (34 Nm) to 18,000 lb-in (2,034 Nm) UL, CSA and CE certification on most units Low profile, light weight High visibility position indicator Simple manual override handwheel system On-off or modulating control Terminal strip for cable terminations Hand or screw driver adjustment of travel limit cams ISO 5211 for direct mounting Optional hazardous location model available Optional Seacorr coating for harsh environments Sizes 130-180 Sizes 003-065 4 BRAY.COM

SERVO NXT SERVO NXT FEATURES / SPECIFICATIONS Servo is available for modulating service, continuous duty actuators only. Actuator Voltage Input Signal Retransmission signal Independent Isolation 120, 220, 24 VAC 50/60 Hz, 1 phase 24 VDC Configurable 4-20 ma, 0-10, 2-10, 0-5 VDC Configurable 4-20 ma, 0-10, 0-5 VDC Control signal input and output Control signals and power The Servo NXT offers precise modulating service for accurate position control. One touch automatic calibration User-friendly interface Advanced control of proportional band and dead band Automatic pulsing mode for precise positioning Self diagnostics Action on loss of command signal Go to position commands Display Menu Navigation Configuration Calibration Menu driven auto dimming LED Up/Down arrows with select ( ) buttons Menu selectable to non-volatile memory Auto calibration sequence for travel limits Deadband Configurable 1% - 6% Reverse Acting Speed Control Fail Position (loss of input signal) Manual Mode Fault Indications Configurable for inverted input signal Independent for open and close direction Configurable close, open, last Local operation via Servo NXT user interface Loss of command signal Limit switch Handwheel engaged Feedback pot Torque switch Jammed valve / motor stalled Health Monitor Heartbeat - Backlit blinking Bray logo Configurable means the customer, or the factory, can modify the Servo NXT. BRAY SERIES 70 ELECTRIC ACTUATORS 5

OPTIONS 1 2 3 1 Control Station The optional control station features a local-off-remote control switch, an open stop-close switch, and two lights which locally indicate open and close valve position. This weatherproof aluminum enclosure is easily bolted to the four mounting holes located on the S70 conduit entry panel. The Control Station cover includes captive bolts and may be rotated in 90 increments allowing the customer to easily operate and view the control station. Two ¾ NPT cable entries are available in the control station base. Two different multi pin, weatherproof electrical cable connections are also available. 2 Battery Backup Unit (BBU) Designed for use with 24V actuators, the optional BBU provides power to permit the actuator to reach its fail-open or fail-close position in the event of a main power failure. Upon reaching the fail position, the BBU turns off until external power is restored. After main power has been restored, the actuator returns to normal operation. 3 Heater Mounted on the actuator switch plate, a self-regulating heater can be added to prevent potential electrical component damage due to condensation build-up inside the actuator. 4 Potentiometer Optional gear driven 10k ohm potentiometer provides continuous position feedback for a customer control system. Potentiometer is standard with the Servo NXT controller. 5 Auxiliary Switches Up to four additional dry-contact (voltage free) SPDT mechanical switches can be added to indicate travel position for remote customer control systems. 6 Torque Switch Optional torque switches provide protection for the automated valve assembly in the event of an over-torque event. 7 Electrical Cable Connections Pre-wired multi-pin weatherproof cable receptacles allow quick-connect field installation and prevent internal cabling errors which could occur during commissioning. Cord sets can be supplied with connection/flying leads or connection/connection on cord set ends to plug directly into the actuator receptacle. 4 5 6 6 BRAY.COM Optional Seacorr coating 7

TECHNICAL SPECIFICATIONS S70-003 S70-006 S70-008* S70-708* S70-012* S70-712* S70-020* S70-720* S70-030 S70-050 S70-065 S70-130 S70-180 Torque lb-in 300 600 800 1200 2000 3000 5000 6500 13000 18000 Nm 34 68 90 136 226 339 565 734 1469 2034 ISO Mounting Base F07 F07 F07/F12 F07/F12 F07/F12 F12/F16 F12/F16 F12/F16 F12/F16 F12/F16 Weight lbs 11 11 25 25 25 45 45 45 118 118 (Approximate) kg 5 5 11 11 11 20 20 20 54 54 MANUAL OVERRIDE in 3.5 3.5 8 8 8 12 12 12 12 12 Handwheel Dia. mm 89 89 203 203 203 300 300 300 300 300 Gear Ratio 30:1 30:1 30:1 30:1 30:1 30:1 30:1 30:1 90:1 90:1 lbs 16 32 18 28 46 37 62 80 80 80 Rim Pull kg 7.2 14.5 8.2 12.7 20.8 16.8 28.1 36.3 36.3 36.3 *Hazardous Location Units 120VAC Travel Time 90 (Sec) S70-003 S70-006 S70-008* S70-708* S70-012* S70-712* S70-020* S70-720* S70-030 S70-050 S70-065 S70-130 S70-180 Current Draw in Amps 60 Hz 50 Hz FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA 10 12 1.20 2.10 1.40 2.30 15 18 0.78 2.10 1.20 2.10 1.70 2.30 18 22 1.80 3.00 2.30 3.10 30 36 0.60 1.00 0.80 1.00 0.60 2.10 0.78 2.10 1.00 2.10 1.20 3.00 1.60 3.00 2.30 3.10 110 132 2.30 3.10 2.50 3.10 *Hazardous Location Units 220VAC Travel Time 90 (Sec) S70-003 S70-006 S70-008 S70-708 S70-012 S70-712 S70-020 S70-720 S70-030 S70-050 S70-065 S70-130 S70-180 Current Draw in Amps 60 Hz 50 Hz FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA FLA LRA 10 12 0.50 0.76 0.60 0.81 15 18 0.38 0.90 0.50 0.76 0.55 0.90 18 22 0.78 1.40 1.10 1.40 30 36 0.60 0.75 0.65 0.75 0.38 0.90 0.45 0.90 0.50 0.81 0.75 1.2 0.90 1.40 1.10 1.40 110 132 1.30 2.70 1.50 2.70 FLA - Full Load Amperage LRA - Locked Rotor Amperage 24VAC Travel Time 90 (Sec) S70-006 S70-020 S70-050 Current Draw in Amps 60 Hz 50 Hz FLA FLA FLA 60 72 1.80 2.00 4.00 24VDC Travel Time 90 (Sec) 40 1.80 S70-006 S70-020 S70-050 Current Draw in Amps FLA FLA FLA 60 2.00 4.00 Travel Time - Motors 30, 40, 60, 110 second motors are continuous duty 10, 15, 18 second motors are intermittent duty For all other information such as dimensional drawings, wiring diagrams, and EDS files please visit bray.com or contact your local Bray representative. BRAY SERIES 70 ELECTRIC ACTUATORS 7

THE HIGH PERFORMANCE COMPANY BRAY INTERNATIONAL PRIMARY SALES AND SERVICE LOCATIONS USA Houston, Texas CHINA Hangzhou, Zhejiang MEXICO Zapopan, Jalisco RUSSIA Moscow AFRICA Johannesburg COLOMBIA Bogotá MIDDLE EAST Dubai SINGAPORE Ubi Techpark BENELUX Heerhugowaard FRANCE Voiron PACIFIC Melbourne, Australia SOUTH KOREA Seoul BRAZIL Paulinia, Sao Paulo GERMANY Krefeld PERU Lima SOUTHEAST ASIA Malaysia CANADA Montreal INDIA Vadodara POLAND Oświȩcim UNITED KINGDOM Glasgow CHILE Santiago ITALY Milano FLOW-TEK RITE CORPORATION AMRESIST KUGELHAHN MÜLLER USA Houston, Texas CANADA Montreal USA Houston, Texas BRAZIL Paulinia, Sao Paulo VALVTRONIC BRAY/VAAS CHINA Hangzhou, Zhejiang ARGENTINA Buenos Aires INDIA Chennai GERMANY Krefeld HEADQUARTERS Bray International, Inc. 13333 Westland East Blvd. Houston, Texas 77041 Tel: 281.894.5454 bray.com All statements, technical information, and recommendations in this bulletin are for general use only. Consult Bray representatives or factory for the specific requirements and material selection for your intended application. The right to change or modify product design or product without prior notice is reserved. Patents issued and applied for worldwide. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. B-1053_EL_Series 70_9_2017