H782. ProcessMultimeter. Instruction

Similar documents
MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS2109A AC/DC Clamp Meter. User Manual. Contents

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

AMM-1022 Digital Multimeter USER`S MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

DIGITAL MULTIMETER INSTRUCTION MANUAL

DIGIT & POINTER MULTIMETER

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Model DIGITAL MULTIMETER

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

DM-45 Digital Multimeter

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

User Manual Digital Multimeter. model no.: MSR-U1000

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

DIGITAL CLAMP METER Use s Manual

DVM1190 DIGITAL MULTIMETER

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

DMM8900 SERIES USERS MANUAL

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

Multifunction Digital

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

User Manual Digital Multimeter

DDM350 Pen-Type Digital Multimeter User s Manual

DIGITAL MULTIMETER AX-588B

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

AC/DC CLAMP METER USER S MANUAL

Digital Clamp Meter. User Manual

Digital Clamp Meter Model: &

1.General instructions Specifications Description...7

VC835 DIGTAL MULTIMETER Operation Manual

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Table of Contents GDM-356. Page

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

True RMS Digital Multimeter Model:

AC750 DIGITAL CLAMP METER

Digital Multimeter, Pen Type

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

KMD-S04 Multímetro de bolsillo

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

The Meter Structure The Figure 2-1 shows the Meter structure.

CONTENTS MS2033A. 1.Introduction Safety Information...01

DCM730. Digital Clamp Meter User s Manual

UT207A/208A/209A Operating Manual. Table of Contents

ProfiScale MULTI Multimeter

MODEL: D03128 CLAMP METER

DIGITAL MULTIMETER OPERATOR S MANUAL

USER'S MANUAL DMR-6700

Digital Multimeter with Backlight

770E DIGITAL MULTIMETER OPERATOR S MANUAL

Analog Technologies VC99. Multimeter FEATURES

Sales: Technical: Fax:

MS8223A. CAT.IIi 600 V

Model : OPERATING MANUAL Table of Contents (1)

INSTRUCTION MANUAL DIGITAL MULTIMETER

Model UT10A: OPERATING MANUAL Table of Contents (1)

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

USER'S MANUAL DMR-4300

DIGITAL MULTIMETER AUTORANGING

User Manual. All rights reserved. Specifications are subject to change without notice.

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Table of Contents Title Page

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

MANUAL DE INSTRUÇÕES DO MULTÍMETRO DIGITAL MODELO MD-6456 Inglês

User Manual. All rights reserved. Specifications are subject to change without notice.

OPERATOR S INSTRUCTION MANUAL

Dawson DDM190. Digital Multimeter User s Manual

400Amp True RMS AC/DC Clamp Meter Model EX613

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Model UT20B: OPERATING MANUAL Table of Contents (1)

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Autoranging Multimeter Extech EX503

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

AX-C Introduction. 2. Safety Information

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Table of Content. The Statement Safety Statement Safety Instructions Safety Operation Specifications Safety Symbols...

METRAVI. Table of Contents

Model UT50D: OPERATING MANUAL. Table of Contents

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

MS2030 CAT III 600 V A V AUTO RS232

Pen-type DIGITAL MULTITESTER

User s Guide. 400A AC/DC Clamp Meter. Model MA220

OPERATING INSTRUCTION

Handheld Digital Multimeter PRO-50A

Transcription:

H782 ProcessMultimeter Instruction

Shenzhen Huayi Instrument Technology Co., Ltd. H782 ProcessMultimeter Content Content 1. Safety Information. 1 1.1 Preparation. 1 1.2 Use. 2 1.3 Marks. 3 1.4 Maintenance. 4 2. Description. 6 2.1 Parts name and relevant description...8 2.2 Display... 10 3. Specification... 12 3.1 Summary... 12 3.2 Technical index... 13 4. Operation guidance.. 20

4.1 Power charging... 20 4.2 Auto power off...21 4.3 Backlight...21 4.4 Reading hold...22 4.5 Function switch...22 4.6 Relative measurement switch...23 4.7 Measurement preparation...24 4.8 DC voltage measurement...25 4.9 AC voltage measurement...26 H782 ProcessMultimeter Content 4.10 DC current measurement. 28 4.11 AC current measurement. 29 4.12 Resistance measurement. 30 4.13 Capacitance measurement. 31 4.14 Diode test. 32 4.15 Circuit break-and-make test. 32 4.16 Frequency measurement. 33 4.17 Triode magnification times measurement 4.18 Temperature measurement thermocouple) (sensor:. 34. 34

4.19 Battery voltage measurement. 35 4.20 Current output. 36 4.21 Voltage output. 37 4.22 Frequency output. 39 4.23 24VDC output. 41 5. Maintenance. 41 5.1 Replace the battery pack. 41 5.2 Replace the protective tube. 42 5.3 Replace the test lead. 43 6. Accessories. 44 H782 ProcessMultimeter Safety information 1. Safety information warning Please pay special attention when using this instrument, improper use may cause electric shock or damage to it. It shall conform to common safety rules and completely follow the safety measures regulated in this instruction. To make the best of the functions of this instrument and ensure safe operation, please

carefully read and follow the use method in this instruction. H782 ProcessMultimeter (hereafter, also referred to as the instrument ) complies with GB/T 13978-92 common technical specifications for digital multimeter and meets GB4793.1-1995 (IEC-1010-1:1990) safety requirements for electronic measuring instrument which subjects to Pollution Grade 2 and Overvoltage Criterion CAT II 1000V/CAT III 600V. Please follow the safety operation guidance to ensure safe use of this instrument. This instrument may serves you well if use and protect it appropriately. 1.1 Preparation 1.1.1 The user must follow standard safety regulations: 1) Normal protection against electric shock 2) Prevent misuse of the instrument H782 PrxocessMultimeter ` Safety information 1.1.2 Check if there is any damage results from transportation after receiving this instrument. 1.1.3 Check and confirm if there is any damage after keeping or transporting the instrument in harsh conditions. 1.1.4 The test leads must be in good condition. Check the test leads for insulativity damage and check the lead wire for exposed metal.

1.1.5 It shall use the test leads attached with the meter to ensure safety. Otherwise if necessary, it must use the same test leads or the one with the same grade. 1.2 Use 1.2.1 It must use the proper input/output jack, function and range. 1.2.2 Do not conduct measurement or output out of the indicated value of protection scope within each range. 1.2.3 Do not contact the tip of test lead (metal part) when connecting the instrument to a circuit under measured. 1.2.4 When measuring, if the measured voltage is higher than 60V DC or 30V AC (virtual value), please be noted to keep fingers behind the finger guard on the probe. 1.2.5 Never measure the voltage higher than 1000V between the measuring terminal and the earth. 1.2.6 If in range of current, resistance, capacitance, diode, break-and-make, temperature, triode or amplification times H782 PrxocessMultimeter ` Safety information test, cares shall be taken to avoid connecting the instrument to the voltage source 1.2.7 Before turning the rotary switch to change measuring function, it shall remove the test lead from the circuit-under-test. 1.2.8 When measuring the switch power circuit, the high-voltage pulse on the test point may damage the instrument.

1.2.9 Do not measure the resistance, capacitance, diode and/or break-and-make that is live. 1.2.10 Do not measure the capacitance before the capacitor is completely discharged. 1.2.11 Never use this instrument near explosive gas, vapor or dust. 1.2.12 If any abnormality or failure found on the instrument, please be sure stop using. 1.2.13 Do not use this instrument unless the bottom case is completely fastened. 1.2.14 Do not store or use this instrument in environment with direct sunshine, high temperature and high humidity. 1.3 Marks Important safety information, please refer to the instruction. There may be dangerous voltage. Dual insulation protection (Category II) CAT The level of pulse withstand voltage provided according to overvoltage (installation) Grade, Pollution Degree 2 H782 PrxocessMeter ` Safety information of IEC-1010-1. CAT The level of pulse withstand voltage provided according to overvoltage (installation) Grade, Pollution Degree 2 of IEC-1010-1 Conform to European Union (EU) directives

Earth ground Protective tube Low battery power 1.4 Maintenance 1.4.1 Please do not attempt to open the bottom case to adjust or repair the instrument, which should only be carried out by the technician who knows the instrument and electric shock risk well. 1.4.2 Before open the battery cover, the test lead shall be removed from the measured circuit. 1.4.3 Once the symbol appears, please charge the instrument with the attached charger immediately to avoid reading error which may cause electric shock. 1.4.4 To avoid combustion, the replacing protective tube must meet specified voltage and current class: F 0.5A/250V (quick fusing) 1.4.5 It shall clean the instrument with wet cloth and detergent, never use abrasive or solvent. 1.4.6 Rotate the rotary switch to OFF when the instrument is not in use. 1.4.7 It shall charge the instrument regularly or remove the battery if it will be not in use for long, in order to avoid damage. H782 PrxocessMeter ` Safety information 2. Description

This meter is a portable and specialized process verification instrument, which presents as a digital verification meter that has both digital multimeter and signal source function, and can measure and output signal simultaneously. Its large liquid crystal digital display can show and measure the output signal value at the same time, and it is equipped with backlight which makes the user easier to read the value. It uses large-capacity rechargeable battery pack and is featured with low voltage indication. Charging and operating for this instrument can be conducted simultaneously (with a charger). Signal output and measurement function of the instrument is mainly designed for on-site verification and service of an instrument in industrial automation field. This instrument is also featured with multimeter function, which makes it an ideal option for field meterman, computer distributed control system maintainer, meter mounter, and can be used as a multimeter by the meterman. - It delivers 24V DC voltage output (I max =30mA), which may be used to supply operating source to two-wire system meter. - Current output. - mv output. - Frequency output. - Voltage output. - The process verification multimeter is used for DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, temperature and break-and-make, diode and triode test. - When using, the instrument displays the measured value and its unit symbol. - The instrument is featured with range auto-switch, reading hold and relative measurement.

H782 ProcessMultimeter Description 2.1 Parts names and relevant descriptions 2 1 6 3 4 7 8 5 9 13 10 12 11

H782 ProcessMultimeter Description 14 15 1) LCD (Liquid crystal display): displays the measured reading and see the magnitude of output signal. 2) Key: to control the output signal to a low increasing speed. 3) Key: to control the output signal to a high increasing speed. 4) /HOLD Key: to control the output signal to a high reducing speed (output display area) or to hold the measured reading (measurement display area) 5) /REL Key: to control the output signal to low reducing speed (output display area) or to read the relative measurement (measurement display area) 6) FUNC Key: to switch among output voltage (output display area), current, frequency, or to switch input signal types (measurement display area). 7) RANGE Key: to switch the range of output signal and turn on/off the backlight. 8) SHIFT Key: to determine whether the key for output or measurement. 9) Rotary switch: to select output measurement function and power switch.

H782 ProcessMultimeter Description 10)INPUT + jack: positive terminal of connection for voltage, current, resistance, frequency, temperature, capacitance, diode, triode, break-and-make position input. 11)INPUT Jack: common terminal for measurement. 12)OUTPUT Jack: negative terminal for output signal. 13)OUTPUT + Jack: positive terminal for output signal 14)Charge Terminal 15)24VDC Output Terminal 2.2 Display 1 2

H782 ProcessMultimeter Description 1) 1Measurement display area 2) 2Output display area Symbol Description Sym bol Description INPUT Input signal Centigrade (temperature) OUTPU T Output signal F Farad (Capacitance) RS232 Reserve Ω Ohm (resistance) AUTO Auto range V Volt (voltage) ~ AC Alternating current Δ H DC Direct current Relative measuremen t Reading hold Buzzing for break-andmake test Diode test A Hz Ampere (current) Hertz (frequency) % Duty cycle (square wave) n μ m k M Unit symbol: nano, micro, milli, kilo, million hfe Triode test Low battery power

H782 ProcessMultimeter Specification 3. Specification It shall define one year as the calibration period of the instrument, which shall be taken place in environment with temperature 18 ~ 28 and relative humidity 75%. 3.1 Summary 3.1.1 30V overload protection for two output terminals. 3.1.2 Auto range. 3.1.3 Overload protection within full range. 3.1.4 The max allowable voltage between the measuring terminal and the earth: 1000V DC or AC (virtual value) 3.1.5 Operation elevation: max 2000m 3.1.6 Display: LCD, which can show output and measured data simultaneously. 3.1.7 Max displayed value: 3999 number. 3.1.8 Polarity indication: auto indicating, - refers to the negative polarity. 3.1.9 Outrange indication: OL or -OL. 3.1.10 Sampling frequency: about 0.4sec/time. 3.1.11 Unit display: display function and electric quantity unit. 3.1.12 Time for auto power off: 15 minutes. 3.1.13 Self-recovery fuse specification: 500mA/250V. 3.1.14 Operating source: 1.2V 4 AA battery pack with

capacity2000mah. 3.1.15 Battery undervoltage indication: LCD shows symbol. 3.1.16 Temperature coefficient: lower than 0.1 accuracy/ 3.1.17 Operating temperature: -10 ~ 40 3.1.18 Storage temperature: -20 ~ 50 3.1.19 Size: 195 92 55mm 3.1.20 Weight: about 600g (including the battery) H782 ProcessMultimeter Specification 3.2 Technical index Operating temperature : 23 5 Relative humidity: <75% 3.2.1 DC voltage Range 400mV 4V 40V 400V 1000V Resolutio n 0.1mV 1mV 10mV 100mV 1V Accuracy ± (0.1% reading + 3 figures) - Input impedance: 10MΩ - Overload protection: 400mV range: 250V DC or AC (virtual value), 4V-1000V range: 1000V DC or 750V AC (virtual value) - Max input voltage: 1000V DC Note: Within the low voltage range, if the test lead is not connected to the circuit under measured, the reading displayed on the instrument may pulse, which should be considered normal for it is caused by the high accuracy of the instrument; if connect the test lead to the circuit

under measured, the true measured value will be captured. H782 ProcessMultimeter Specification 3.2.2 AC voltage Range 4V 40V 400V Resoluti on 1mV 10mV 100mV Accuracy (0.8% reading + 3 figures) 700V 1V (1.0% reading + 10 figures) - Input impedance: 10MΩ - Overload protection: 1000V DC or 700V AC (virtual value) - Max input voltage: 700V AC (virtual value) - Frequency range: 40 ~ 400Hz - Display: mean value (virtual value of sine wave) Note: Within the low voltage range, if the test lead isn t connected to the circuit under measured, the reading displayed on the instrument may pulse, which should be considered normal for it is caused by the high accuracy of the instrument; if connect the test lead to the circuit under measured, the true measured value will be captured.

H782 ProcessMultimeter 3.2.3 DC current Range 400 A 4000 A 40mA 400mA Resolutio n 0.1 A 1 A 10 A 100 A Accuracy (0.1% reading + 5 figures) Specification - Overload protection: A, ma range: quick fusing cartridge fuse 500mA/250V - Voltage drop 400 A range: 400mV, 4000 A range: 4V, 40mA range: 400mV, 400mA range: 4V 3.2.4 AC current Range Resolutio n Accuracy

400 A 4000 A 40mA 400mA 0.1 A 1 A 10 A 100 A (1% reading + 5 figures) - Overload protection: A, ma range: quick fusing cartridge fuse 500mA/250V - Voltage drop 400μA range: 400mV, 4000μA range: 4V, 40mA range: 400mV, 400mA range: 4V, - Frequency range: 40 ~ 400Hz - Display: mean value (virtual value of sine wave) H782 ProcessMultimeter Specification 400μA range: 400mV, 4000μA range: 4V, 40mA range: 400mV, 400mA range: 4V, - Frequency range: 40 ~ 400Hz - Display: mean value (virtual value of sine wave) 3.2.5 Resistance Range Resolutio n 400Ω 0.1Ω 4kΩ 40kΩ 400kΩ 4MΩ 1Ω 10Ω 100Ω 1kΩ Accuracy (0.3% reading + 5 figures) 40MΩ 10kΩ (2.0% reading + 5 figures) - Open-circuit voltage: about 0.25V

- Overload protection: 250V DC or AC (virtual value) 3.2.6 Capacitance Range 40nF 400nF 4 F 40 F 100 F Resolutio n 10pF 0.1nF 1nF 10nF 100nF Accuracy (2.0% reading + 10 figures) - Overload protection: 250V DC or AC (virtual value) --- H782 ProcessMultimeter 3.2.7 Frequency Range 9.999Hz 99.99Hz 999.9Hz 9.999kHz 99.99kHz 199.9kHz >200kHz Resolutio n 0.001Hz 0.01Hz 0.1Hz 1Hz 10Hz 100Hz Accuracy 10 figures Only for reference 1) Measuring range: 0 ~5MHz

2) Input frequency amplitude: when in 0~100kHz, the amplitude is higher than 500mV when in 100kHz~5MHz, the amplitude is higher than 3V. 3)Input frequency amplitude shall not be higher than 10V. 4)Overload protection: 250V DC or AC (virtual value) H782 ProcessMultimeter Specification 3.2.8 Circuit break-and-make test Range Function If the resistance of circuit under measured lower than 40, the buzzer in the instrument makes sounds. - Open-circuit voltage: about 0.5V - Overload protection: 250V DC or AC (virtual value) 3.2.9 Diode test Range Resoluti on 1mV Function Indicate the approximate value of forward voltage of diode

- The forward DC current is about 1mA - The backward DC voltage is about 1.5V - Overload protection: 250V DC or AC (virtual value) 3.2.10 Triode test hfe: 0~4000 - Overload protection: quick fusing cartridge fuse 500mA/250V 3.2.11 Temperature measurement: K-type thermoelectric couple (optional). - Overload protection: quick fusing cartridge fuse 500mA/250V H782 ProcessMultimeter 3.2.12 DC voltage signal Range 10V 100mV Resolutio n 10mV 100μV Accuracy Specification ± (0.1% reading + 5 figures) 3.2.13 DC voltage signal Range Resol ution Accuracy 22mA 10μA ±(0.1% reading + 5 figures)

- Load capacity: 0~800Ω (over 1kΩ below 20mA). 3.2.14 Frequency signal Range Resolution Accuracy 1~100Hz 0.01Hz ±0.1Hz 100Hz ~ 0.1Hz ±0.5 Hz 1kHz 1~10kHz 1Hz ±5 Hz - Square wave, duty cycle 50%, amplitude 4V. 3.2.15 24V DC voltage output Voltage Accurac y Load capacity 24V 2% 30mA H782 ProcessMultimeter Operation guidance 4. Operation guidance 4.1 Power charging Considering the actual condition of field use, AC and DC power sources are both available to this instrument. There are a pack of rechargeable batteries inside this instrument. In condition there is 220V AC current, the attached charger can be used to supply operating source to the instrument (charging the battery at the same time). When the voltage of the battery pack is lower than 4.4V, the symbol (undervoltage) appears. The instrument shall be charged with 220V AC current.

Generally, it shall power off the instrument before charging, and then use the attached charger to charge the battery, which shall follow below steps: 1) Plug the charger into 220V AC socket, then the green Indicator light will be on. 2) Use the connecting cable to connect the charger to the Charge terminal on the top of the instrument, then the indicator light will be converted from green to red, which indicates that the instrument in charging. 3) When the indicator light converted from red to green, it indicates an end to thi charging. The charging shall last for4~6 hours. The battery shall be full charged in each charging, otherwise its service life may be influenced. Generally, a full charged battery can work for more than 24 hours, and under the condition with maximum output current 20mA, it may deliver 8 hours of continuous service. If the work time of the instrument is significantly reduced, it shall take a replacement of the battery into account. H782 ProcessMultimeter Operation guidance 4.2 Auto power off 1) If there is no any operation (except pressing SHIFT) within 15 minutes after power on, the output display area and measurement

display area of the instrument will turn to sleeping state through power off to save electricity energy. 2) After power off, if turn the rotary switch or press any one of /HOLD, /REL and FUNC key, the measurement display area restores to normal operation. If in output state, pressing FUNC key may make the output display area restore to normal operation. 3) If press and hold FUNC key to power on, the auto power off function of measurement display area will be cancelled. 4.3 Backlight 1) If it is difficult to read figures due to poor light condition in measuring, RANGE key may be long pressed for over 2s to turn on the backlight. 2) Long press the RANGE over 2s again may turn off the backlight. 3) After the backlight is on, if RANGE is not long pressed for over 2s, it will be auto turned off 10s later. Note: 1) The illuminant of backlight is LED with high operating current. Though this instrument has timing circuit (the set interval is about 10s, i.e., the backlight will be auto turned off 10s later after turned it on), but frequent use of the backlight will reduce the life of battery, it shall use the backlight as less as possible, unless necessary. 2) The brightness of the backlight will decline along with the reduced voltage of battery pack. H782 ProcessMultimeter Operation guidance 4.4 Reading hold

1)If reading hold is required in measuring, it may press /HOLD, then the buzzer makes a sound, the value displayed in the measurement display area is locked. 2)Press again, then the buzzer makes a sound, the reading hold state is removed. 4.5 Function switch 1)In voltage, current range, press FUNC, the instrument will be switched between AC and DC. 2) In diode and break-and-make range, press FUNC, the instrument will be switched between the two ranges. 4.6 Relative measurement switch 1)When measuring, press /REL, then the instrument go to relative measurement state with initial reading returned to zero. 2) In relative measurement state, if current displayed value is stored in the memory as the reference value, in future measurement, the displayed value will be the difference value results from subtracting the reference value from the input value. i.e., /REL (current reading)= input value reference value. 3) After pressing /REL, the instrument enters into manual range mode. 4) In REL measurement state, by pressing this key again, the relative measurement ( ) function is removed. 5) In reading hold state, by pressing this key, the reading hold is cancelled, and the actual measured valued is stored in the memory as the reference value, in future measurement, the displayed value will be the difference value results from subtracting the reference value from the input value. 6) Press FUNC key or turncap switch both lead to cancel of REL measurement mode to return to normal measurement state (the symbol on the screen disappears).

H782 ProcessMultimeter Operation guidance 7) OL triggering: in REL mode, when the input value higher than the allowable value within this range, it shows OL, press this key again, the relative value measurement function cancels; when OL is showing on the screen, REL mode is not accessible. 4.7 Measurement preparation 1) Turn the rotary switch, switch on the power. If the battery voltage is low ( 4.4V approximately), the display shows the symbol,which indicates that the battery pack needs to be charged. 2) The symbol nearby the input wire indicates the input voltage or current shall not be higher than indicated value, in order to protect the internal line from damage. 3) Turn the rotary switch to required measuring function and range. 4) When connecting wires, the common test wire shall be connected first, then the live test wire. And when removing wires,the live test wire shall be removed first. 5) Never measure high voltage or current when the rotary switch is at Ω scale. And never carry out misoperation of voltage measuring when the rotary switch is at ma or μa scale, inorder to avoid damage to the instrument. 6) Do not connect the test lead to measured signal when turning the rotary switch.

H782 ProcessMultimeter Operation guidance 4.8 DC voltage measurement Warning Electric shock danger. It shall pay special attention to avoid electric shock when measuring high voltage. Do not input voltage higher than DC1000V, higher voltage value display is accessible, but may expose the internal line in risk of damage. 4.8.1 Turn the rotary switch to V scale. It shows measuring unit --- mv, signal type DC and auto switch range mark AUTO in LCD measurement display area at this moment. 4.8.2 If the signal type is AC, it shall press FUNC to switch it to DC. If switching is not available, press SHIFT. ~ 4.8.3 Respectively plug the black test lead and the red test lead into INPUT jack and OUTPUT+ jack. 4.8.4 Connect the test leads to the two terminals of voltage source or load in parallel for measuring. 4.8.5 Read values in the measurement display area of LCD. Polarity indication will show the polarity of terminal connected with the red test lead.

H782 ProcessMultimeter Operation guidance Note 1) Within the low voltage range, if the test lead isn t connected to the circuit under measured, the reading displayed on the instrument may pulse, which should be considered normal for it is caused by the high accuracy of the instrument; if connect the test lead to the circuit under measured, the true measured value will be captured. 4.9 AC voltage measurement Warning Electric shock danger. It shall pay special attention to avoid electric shock when measuring high voltage. Do not input voltage higher than DC750V, higher voltage value display is accessible, but may expose the internal line in risk of damage. ~ 4.9.1 Turn the rotary switch to V scale. It shows measuring unit --- V, signal type DC and auto switch range mark AUTO in LCD measurement display area at this moment. 4.9.2 Press FUNC to switch it to AC measuring state, the measurement display area shows signal type AC. If switching is not available, press SHIFT.

4.9.3 Respectively plug the black test lead and the red test lead into INPUT jack and OUTPUT+ jack. 4.9.4 Connect the test leads to the two terminals of voltage source or load in parallel for measuring. 4.9.5 Read values in the measurement display area of LCD. H782 ProcessMultimeter Operation guidance Note: 1) Within the low voltage range, if the test lead isn t connected to the circuit under measured, the reading displayed on the instrument may pulse, which should be considered normal for it is caused by the high accuracy of the instrument; if connect the test lead to the circuit under measured, the true measured value will be captured. 4.10 DC current measurement Warning Electric shock danger. It shall power off the circuit under measured first, then connect the instrument to circuit in serials for measuring, Do not input current higher than 400mA, excessive current will burn out the protective tube. 4.10.1 Turn the rotary switch to ma or μa,if the range is --- --- unknown, it d better turn it to ma --- ~, LCD shows measuring unit ma or μa with type DC (direct current) at the moment. 4.10.2 If the signal type is AC, it shall press FUNC to switch it to DC. If switching is not available, press SHIFT. ~ ~

4.10.3 Respectively plug the black test lead and the red test lead into INPUT jack and INPUT+ jack. 4.10.4 Connect the test leads to the circuit under measured in serials for measuring. 4.10.5 Read values in the measurement display area of LCD. Polarity indication will show the polarity of terminal connected with the red test lead. H782 ProcessMultimeter Operation guidanc 4.11 AC current measurement Warning Electric shock danger. It shall power off the circuit under measured first, then connect the instrument to circuit in serials for measuring, Do not input current higher than 400mA, excessive current will burn out the protective tube. 4.11.1 Turn the rotary switch to --- ~ ma or --- ~ μa,if the range is unknown, it d better turn it to --- ~ ma, LCD shows measuring unit ma or μa with type DC (direct current) at the moment. 4.11.2 Press FUNC to switch it to AC measuring state with type AC. If switching is not available, press SHIFT. 4.11.3 Respectively plug the black test lead and the red test lead into INPUT NPUT+ jack. 4.11.4 Connect the test leads to the circuit under measured in serials for measuring.

4.11.5 Read values in the measurement display area of LCD. Polarity indication will show the polarity of terminal connected with the red test lead. H782 ProcessMultimeter Operation guidance 4.12 Resistance measurement Warning Electric shock danger. When measuring the impedance of the line, it shall confirm if the circuit source is disconnected and the capacitor on the circuit is completely discharged. 4.12.1 Turn the rotary switch to Ω, LCD shows unit MΩ. And It shows OL when exceeding the max range 40MΩ 4.12.2 Respectively plug the black test lead and the red test lead into INPUT jack and INPUT+ jack. 4.12.3 Connect the test leads to the two terminals of the resistance or circuit under measured for measuring. 4.12.4 Read values in the measurement display area of LCD. Note: 1) When input into an open circuit, LCD shows outrange state OL. 2) If the resistance of the resistor under measured is higher than

1MΩ, it will take several seconds for the instrument to read stably, which is normal for high resistance value reading. H782 ProcessMultimeter Operation guidance 4.13 Capacitance measurement Warning Electric shock danger. It shall discharge the capacitor completely before measuring the capacitor to avoid electric shock. 4.13.1 Turn the rotary switch to, LCD shows measuring unit nf. 4.13.2 Respectively plug the black test lead and the red test lead into INPUT jack and INPUT+ jack. 4.13.3 Connect the test leads to the two terminals of the capacitor after completely discharged for measuring. 4.13.4 Read values in the measurement display area of LCD. Note: 1) If measure a capacitor with large capacity, it will take several seconds for the instrument to read stably (30s at 200μF scale). 2) When input into an open circuit, LCD may show the reading, and /REL key could by pressed to return it to zero for another measuring.

3) When measuring the capacitor is not easy for the test lead, it may use the multitap attached with the instrument. H782 ProcessMultimeter Operation guidance 4.14 Diode test 4.14.1 Turn the rotary switch to. 4.14.2 Respectively plug the black test lead and the red test lead into INPUT jack and INPUT+ jack. 4.14.3 Press FUNC to switch to measuring state. LCD shows type symbol with unit V. If switching is not available, press SHIFT. 4.14.4 Respectively connect the red test lead and the black test lead to the positive pole and negative pole of the diode for testing. 4.14.5 The reading showed in the LCD measurement display area is the forward voltage drop of diode. Note: 1) The reading showed on the instrument is the approximation of forward voltage drop of diode. 2) If the test lead is connected backward or is open-circuit, LCD shows OL. 4.15 Circuit break-and-make test Warning Electric shock danger.

It shall confirm if the circuit source is disconnected and the capacitor on the circuit is completely discharged before testing the circuit break-and-make. 4.15.1 Turn the rotary switch to. 4.15.2 Respectively plug the black test lead and the red test lead into INPUT jack and INPUT+ jack. 4.15.3 Press FUNC to switch to break-and-make test state. LCD shows the type symbol with unit Ω. If switching is not available, press SHIFT. H782 ProcessMultimeter Operation guidance 4.15.4 Connect the test leads to the two terminals of the circuit for measuring. 4.15.5 If the resistance of the circuit under measured is lower than 40, the buzzer inside the instrument will make sounds. 4.15.6 Read the resistance value in the measurement display area of LCD. Note: If the test lead is open-circuit (or the resistance of circuit under measured is higher than 400 ), the display shows OL. 4.16 Frequency measurement 4.16.1 Turn the rotary switch to Hz, LCD shows measurement unit Hz. 4.16.2 Respectively plug the black test lead and the red test lead into INPUT jack and INPUT+ jack.

4.16.3 Connect the test leads to the two terminals of the power source or load for measuring. 4.16.4 Read values in the measurement display area of LCD. 4.17 Triode magnification times hfe measurement 4.17.1 Turn the rotary switch to hfe, LCD shows hfe. 4.17.2 Respectively plug the COM joint pin and the IN joint pin into INPUT jack and INPUT+ jack. 4.17.3 Plug the triode into relevant position of multitap depending on the type of triode (PNP or NPH). 4.17.4 Read values in the measurement display area of LCD. H782 ProcessMultimeter Operation guidance 4.18 Temperature measurement Warning INPUT jack shall not be connected with electricity signal to avoid damage to the instrument. 4.18.1 Turn the rotary switch to, LCD shows measuring unit and measured value OL. 4.18.2 Respectively put the red plug and black plug of the k-type thermoelectric couple into OUTPUT jack+ and INPUT jack, and contact the test probe of the thermoelectric couple with

measured object or area for measuring. 4.18.3 Read values in the measurement display area of LCD. 4.18.4 Make the two test leads short-circuit connected to display environment temperature. Note: There is no cold junction compensation to the k-type thermoelectric couple when measuring the temperature with the instrument. H782 ProcessMultimeter Operation guidance 4.18.3 Read values in the measurement display area of LCD. 4.18.4 Make the two test leads short-circuit connected to display environment temperature. Note: There is no cold junction compensation to the k-type thermoelectric couple when measuring the temperature with the instrument. 4.19 Battery voltage measurement Warning INPUT jack shall not be connected with electricity signal to avoid damage to the

instrument. 4.19.1 Turn the rotary switch to Vbat, the measurement display area of LCD shows the same information as that of voltage measurement. 4.19.2 The reading showed on the measurement display area of LCD is current battery voltage. 4.19.3 When the battery voltage is lower than 4.3V, it shall be charged immediately. Note: This function provides convenience for understanding of the state of the battery used in this instrument timely. H782 ProcessMultimeter Operation guidance 4.20 Current output Warning OUTPUT jack shall not be connected with the voltage higher than 30V to avoid damage to the instrument. 4.20.1 Turn the rotary switch until it leaves OFF to power on. 4.20.2 Press SHIFT to make all keys under used for output state. 4.20.3 Press FUNC to select output signal type (such as current output). The output display area of LCD shows type DC with

measuring unit ma. 4.20.4 Respectively plug the red test clip and the black test clip into OUTPUT+ and OUTPUT, then the current flows out from the red test clip and flow into the black test lead. 4.20.5 The magnitude of signal shall be adjusted with key,, and. 4.20.6 The reading in the measurement display area of LCD is the Note: magnitude of current output current. 1) Current output is source output, which requires the external to constitute a loop. i.e., it shall make a short-circuit connection between the two test clips or connect to appropriate load. 2) Max output current could be up to 24mA when the load resistance is below 800Ω. If the resistance is higher than 800Ω, the current declines. 3) When adjusting the signal, click or to change one or two figures of the output signal approximatively. When pressing and holding any of these keys, the output signal changes continuously. H782 ProcessMete Operation guidance 4) When adjusting the signal, click or to change dozens of figures of the output signal approximatively. When pressing and holding any of these keys, the output signal changes continuously. 5) By pressing + simultaneously, the output current rises to its max value, while pressing +, the output current declines to its min value. 4.21 Voltage output Warning

OUTPUT jack shall not be connected with the voltage higher than 30V to avoid damage to the instrument. 4.21.1 Turn the rotary switch until it leaves OFF to power on the instrument. 4.21.2 Press SHIFT to make all keys under used for output state. 4.21.3 Press FUNC to select output signal type (such as voltage output).then the output display area of LCD shows type D C with measuring unit V. 4.21.4 The voltage output has two scales: 0~10V and 0~100mV, which can be switched using RANGE key to ensure different resolutions. 4.21.5 Respectively plug the red test clip and the black test clip into OUTPUT+ and OUTPUT. The former is the positive terminal of the voltage while the latter is the negative terminal. 4.21.6 The magnitude of signal shall be adjusted with key,, and. 4.21.7 The reading showed in the measurement display area of LCD is the magnitude of current output voltage. H782 ProcessMultimeter Operation guidance Note: 1) There is overload protection for the output, the output voltage load shall not be higher than 20mA. 2) When adjusting the signal, click or to change one or two figures of the output signal approximatively. When pressing and

holding any of these keys, the output signal changes continuously. 3) When adjusting the signal, click or to change dozens of figures of the output signal approximatively. When pressing and holding any of these keys, the output signal changes continuously. 4) By pressing + simultaneously, the output voltage rises to its max value, while pressing +, the output voltage declines to its min value. 4.22 Frequency output Warning OUTPUT jack shall not be connected with voltage higher than 30V to avoid damage to the instrument. 4.22.1 Turn the rotary switch until it leaves OFF to power on the instrument. 4.22.2 Press SHIFT to make all keys under used for output state. 4.22.3 Press FUNC to select output signal type (such as frequency output). Then the output display area of LCD shows measuring unit khz. H782 ProcessMultimeter Operation guidance Then the output display area of LCD shows measuring unit khz.

4.22.4 The frequency output has two scales: 0~1kHz and 0~10kHz, which can be switched using RANGE key to ensure different resolutions. 4.22.5 Respectively plug the red test clip and the black test clip into OUTPUT+ and OUTPUT. The former is the positive terminal of the voltage while the latter is the negative terminal. 4.22.6 The magnitude of signal shall be adjusted with key,, and. 4.22.7 The reading showed on the measurement display area of LCD is the magnitude of current output frequency. Note: 1) The output amplitude of output frequency is 4V, square wave. 2) When adjusting the signal, click or to change one or two figures of the output signal approximatively. When pressing and holding any of these keys, the output signal changes continuously. 3) When adjusting the signal, click or to change dozens of figures of the output signal approximatively. When pressing and holding any of these keys, the output signal changes continuously. 4) By pressing + simultaneously, the output frequency rises to its max value, while pressing +, the output voltage declines to its min value.

H782 ProcessMultimeter Operation guidance 4.23 24V DC output 4.25.1 Turn the rotary switch until it leaves OFF to power on the instrument. 4.25.2 There is 24 V terminal at the front of the instrument for 24V source output. Note: 1)This 24V power source can deliver 30mA current output and contains short-circuit protection device inside. 5. Maintenance 5.1 Replace the battery pack Warning It shall remove the test lead from the circuit under measured before opening the battery cover of the instrument to avoid electric shock danger. 5.1.1 If the service life of battery pack reduced significantly after fully charged, it indicates the battery pack shall be replaced. 5.1.2 Unscrew the fastening screw on the battery cover to remove them. 5.1.3 Replace the used battery pack. 5.1.4 Put the battery cover back. Note: The polarity of battery pack shall not be fitted reversed, and the replacing battery pack shall be with the same specification as the one under replaced.

H782 ProcessMultimeter Maintenance 5.2 Replace the protective tube Warning It shall remove the test lead from the circuit under measured before opening the battery cover of the instrument to avoid electric shock danger. To avoid catching fire, the specified class of replacing protective tube is: F 0.5A/250V (quick fusing) 5.2.1 The protective tube seldom needs replacement, a burn-out of this almost always due to misoperation. 5.2.2 Unscrew the fastening screw on the battery cover and remove them. 5.2.3 Replace the protective tube with the one with specified class. 5.2.4 Put the battery cover back. 5.3 Replace the test lead Warning The replacing test lead shall use the same one as the original test lead or the one with the same class. The test lead shall be in good condition of which the class is : 1000V 10A. If the isolating layer damaged, for instance, the metal wire of the lead exposed, the test lead must be replaced.

H782 ProcessMultimeter Maintenance 6. Accessories 1) Test leads Class: 1000V 10A 2) Thermoelect ric couple 3) Multi-purpos e socket k-type TP01 MS3201 A pair A pair One 3) Instruction H782 One 4) Test clip MS3102 A pair 5) Charger HY-2 One 6) 24V output wire One 7) Certification One

Shenzhen Huayi Instrument Technology Co., Ltd. Address: Building 3, West Floor 9, SEG Technology Industrial Park,

North Huaqiang Road, Shenzhen City (518028) Tel: 86-755-83769588 Fax: 86-755-83768150 Website: WWW.SZHYTECH.NET