FINAL DOCUMENT. Title: Medical Devices Post Market Surveillance: Content of Field Safety Notices. Endorsed by: The Global Harmonization Task Force

Similar documents
PROPOSED DOCUMENT. Global Harmonization Task Force. Title: Medical Devices: Post Market Surveillance: Content of Field Safety Notices

Global Harmonization Task Force

Preparing for the new Regulations for healthcare providers

Final Document. Title: The GHTF Regulatory Model. Authoring Group: Ad Hoc GHTF SC Regulatory Model Working Group

DNVGL-CP-0338 Edition October 2015

Medical Devices cyber risks and threats

Issues in Emerging Health Technologies Bulletin Process

ISO INTERNATIONAL STANDARD

Guidance for Industry and FDA Staff Use of Symbols on Labels and in Labeling of In Vitro Diagnostic Devices Intended for Professional Use

UPDATE TO MEDICAL DEVICE CORRECTION

Type Approval JANUARY The electronic pdf version of this document found through is the officially binding version

Software as a Medical Device (SaMD)

ILNAS-EN 14136: /2004

This document is a preview generated by EVS

1 SERVICE DESCRIPTION

CADTH HEALTH TECHNOLOGY MANAGEMENT PROGRAM Horizon Scanning Products and Services Processes

LOREM IPSUM XXX MEDICAL DEVICES NEWS OCTOBER 2012 SPECIAL POINTS OF INTEREST: XXX EDITORIAL

Convergence and Differentiation within the Framework of European Scientific and Technical Cooperation on HTA

SAUDI ARABIAN STANDARDS ORGANIZATION (SASO) TECHNICAL DIRECTIVE PART ONE: STANDARDIZATION AND RELATED ACTIVITIES GENERAL VOCABULARY

PRIMATECH WHITE PAPER COMPARISON OF FIRST AND SECOND EDITIONS OF HAZOP APPLICATION GUIDE, IEC 61882: A PROCESS SAFETY PERSPECTIVE

Guide on the General and Administrative Aspects of the Voluntary System of Modular Evaluation of Measuring instruments

INTERNATIONAL STANDARD

NEMA Standards Publication ICS Adjustable Speed Electrical Power Drive Systems

Thank you for the opportunity to comment on the Audit Review and Compliance Branch s (ARC) recent changes to its auditing procedures.

MEDICAL TECHNOLOGY REGULATION. Understanding Where We Have Been and Where We Are Going with Harmonization

Technical Meeting on Stakeholder Involvement across the Nuclear Power Plant Life Cycle

NEMA XR X-ray Equipment for Interventional Procedures User Quality Control Mode

EU regulatory system for robots

Prof. Steven S. Saliterman. Department of Biomedical Engineering, University of Minnesota

COMMUNICATION FROM THE COMMISSION TO THE EUROPEAN PARLIAMENT. pursuant to Article 294(6) of the Treaty on the Functioning of the European Union

Australian/New Zealand Standard

ISO INTERNATIONAL STANDARD. Nomenclature Specification for a nomenclature system for medical devices for the purpose of regulatory data exchange

IEEE C802.16h-06/127. IEEE Broadband Wireless Access Working Group <

The Medical Device Regulation: Transitioning between old and new

ETSI EN V1.1.1 ( )

WHO Regulatory Systems Strengthening Program

Deciding When to Submit a 510(k) for a Software Change to an Existing Device Draft Guidance for Industry and Food and Drug Administration Staff

Recast de la législation européenne et impact sur l organisation hospitalière

IEEE l-00/16. IEEE Broadband Wireless Access Working Group <

Reflection Paper on synergies between regulatory and HTA issues. DG SANTE Unit B4 Medical products: safety, quality, innovation

Final draft ETSI EN V1.3.1 ( )

GENERAL DESCRIPTION OF THE CMC SERVICES

Essential requirements for a spectrum monitoring system for developing countries

Safety of Toys Implementing Regulation

AS/NZS :2012. Specification for preservative treatment AS/NZS :2012. Part 4: Laminated veneer lumber (LVL) Australian/New Zealand Standard

Applied Safety Science and Engineering Techniques (ASSET TM )

Meeting The Language Requirements of the EU s Medical Device Regulation

INTERNATIONAL. Medical device software Software life cycle processes

SHTG primary submission process

Playground equipment and surfacing. Part 1: General safety requirements and test methods (EN :2008, MOD) AS :2014

Justin McCarthy John Amoore, Paul Blackett, Fran Hegarty, Richard Scott. Regulations, Guidance and Standards

Test Standard for the Determination of the Visible Entrance Field of an X-Ray Image Intensifier System

Doing, supporting and using public health research. The Public Health England strategy for research, development and innovation

ISO INTERNATIONAL STANDARD. Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology, methodology

This document is a preview generated by EVS

ETSI EN V1.1.2 ( ) Harmonized European Standard

ETSI EN V1.3.1 ( )

January 8, Licensing Requirements for Implantable Medical Devices Manufactured by 3D Printing; Draft Guidance. Dear Sir or Madame:

Medical Device Regulatory Update

CENTER FOR DEVICES AND RADIOLOGICAL HEALTH. Notice to Industry Letters

Australian/New Zealand Standard

Medical Technology Association of NZ. Proposed European Union/New Zealand Free Trade Agreement. Submission to Ministry of Foreign Affairs & Trade

Renewal of EC Design-Examination and Type-Examination Certificates

Australian/New Zealand Standard

ETSI EN V1.1.1 ( )

Standard and guidance for the creation, compilation, transfer and deposition of archaeological archives

ETSI EN V1.5.1 ( ) Harmonized European Standard (Telecommunications series)

A53106 SERIES DC-TO-DC CONVERTER

Co-ordination of the Group of Notified Bodies for the Construction Products Directive 89/106/EEC. GNB-CPD Conference on CPR

Controlling Changes Lessons Learned from Waste Management Facilities 8

Circular letter No. 16

HT1100 Satellite Modem User Guide

Contents. 1. Play and Control PLAYING RULES POST. International Correspondence Chess Federation. Valid from 01/01/2017

MANUAL. Textron Motors Diagnostic Tool. This manual is valid for the following Textron Motors Diagnostic Tool:

Requests for Reconsideration of Library Materials 2011 Annual Report

AS/NZS :2015. Methods of testing bitumen and related roadmaking products AS/NZS :2015

ETSI EN V1.2.1 ( ) Harmonized European Standard (Telecommunications series)

YY / ISO 15223:2000

Product Navigator Submission Guidelines and FAQs

Digital Product Definition Data Practices

IEEE C802.16h-05/001. IEEE Broadband Wireless Access Working Group <

NOTE BY THE DIRECTOR GENERAL STATUS OF THE FOLLOW-UP TO THE RECOMMENDATIONS ON SCIENCE AND TECHNOLOGY MADE TO THE THIRD REVIEW CONFERENCE

IEEE Broadband Wireless Access Working Group < Proposed PAR to convert P802.16d from Amendment to Revision

ICH Q10 Pharmaceutical Quality System

clarification to bring legal certainty to these issues have been voiced in various position papers and statements.

NTCIP 1205:2001 v01.08

TERMS OF REFERENCE Supporting Implementation of HPNSDP. Technical Assistance for Improving TA Mechanism for the next Health Sector Programme

WML- 46### User Manual

Summary 18/03/ :27:42. Differences exist between documents. Old Document: en_ v010501p 17 pages (97 KB) 18/03/ :27:35

IGEM/TD/101 Edition 2 Communication 1740 Adoption of pipe systems by a GT management of UIP activities

ETSI EN V1.4.1 ( )

Counterfeit Medicines Toolkit 4. Information about the International Medical Products Anti-Counterfeiting Taskforce (IMPACT)

80403NT11218A Rev

Parenteral Nutrition Down Under Inc. (PNDU) Working with Pharmaceutical Companies Policy (Policy)

Electronic article surveillance systems

19 and 20 November 2018 RC-4/DG.4 15 November 2018 Original: ENGLISH NOTE BY THE DIRECTOR-GENERAL

ISO/TC145-IEC/SC3C JWG 11 N 64

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

ETSI EN V1.2.3 ( ) Harmonized European Standard (Telecommunications series)

ETSI EG V1.1.1 ( )

Transcription:

GHTF/SG2/N57R8:2006 FINAL DOCUMENT Title: Medical Devices Post Market Surveillance: Content of Field Safety Notices Authoring Group: Study Group 2 Endorsed by: The Global Harmonization Task Force Date: 27 June 2006 Georgette Lalis, GHTF Chair The document herein was produced by the Global Harmonization Task Force, which is comprised of representatives from medical device regulatory agencies and the regulated industry. The document is intended to provide non-binding guidance for use in the regulation of medical devices, and has been subject to consultation throughout its development. There are no restrictions on the reproduction, distribution or use of this document; however, incorporation of this document, in part or in whole, into any other document, or its translation into languages other than English, does not convey or represent an endorsement of any kind by the Global Harmonization Task Force. Copyright 2000 by the Global Harmonization Task Force

Table of Contents 1.0 Scope... 4 2.0 References... 4 3.0 Definitions... 4 4.0 Content of the Field Safety Notice... 5 27 June 2006 Page 2 of 6

Preface The document herein was produced by the Global Harmonization Task Force, a voluntary group of representatives from medical device regulatory agencies and the regulated industry. The document is intended to provide non-binding guidance for use in the regulation of medical devices, and has been subject to consultation throughout its development. There are no restrictions on the reproduction, distribution or use of this document; however, incorporation of this document, in part or in whole, into any other document, or its translation into languages other than English, does not convey or represent an endorsement of any kind by the Global Harmonization Task Force. 27 June 2006 Page 3 of 6

Introduction Manufacturers or their representatives may sometimes need to undertake corrective or preventative action in relation to their medical devices. These include safety related field corrective actions taken by the manufacturer to reduce the risk of harm to patients, operators or others and/or to minimise the re-occurrence of the event. 1.0 Scope This document identifies elements that should and should not be included in safety related notifications issued by the medical device manufacturer or its representative. This document does not cover the distribution method or any requirements for communications to relevant Competent Authorities prior to publication of the safety related notifications. 2.0 References No references 3.0 Definitions Field Safety Corrective Action A field safety corrective action (FSCA) is an action taken by a manufacturer to reduce a risk of death or serious deterioration in the state of health associated with the use of a medical device. In assessing the need of the FSCA the manufacturer may use the methodology described in the harmonised standard EN ISO 14971. This may include: the return of a medical device to the manufacturer or its representative; device modification 1 ; device exchange; device destruction; advice given by manufacturer regarding the use of the device (e.g. where the device is no longer on the market or has been withdrawn but could still possibly be in use e.g. implants) Device modifications may include: retrofit in accordance with the manufacturer's modification or design change; permanent or temporary changes to the labelling or instructions for use; software upgrades including those carried out be remote access; modification to the clinical management of patients to address a risk of serious injury or death related specifically to the characteristics of the device. For example: 1 Note: device modifications may need to be approved by the NCA or third parties. 27 June 2006 Page 4 of 6

For implantable devices it is often clinically unjustifiable to explant the device. Corrective action taking the form of special patient follow-up, irrespective of whether any affected unimplanted devices remain available for return. For any diagnostic device (e.g. IVD, imaging equipment or devices) the retesting of affected patients, samples or the review of previous results. Advice on a change in the way the device is used (e.g. IVDS manufacturer advises revised quality control procedure -use of third party controls or more frequent calibration). Field Safety Notice A communication sent out by a manufacturer or its representative to the device users in relation to a Field Safety Corrective Action. 4.0 Content of the Field Safety Notice The Field Safety Notice should be sent in the official language of the recipient. If the manufacturer or its representative wishes to use another language, a consultation of the competent authority of the recipient is recommended to avoid re-sending requested by the competent authority. The manufacturer or its representative should use common layout techniques to highlight the most important parts of the letter and to have a clearly arranged notice. The Field Safety Notice itself should include the following items A clear title like Urgent Safety Notice on the notice itself, the envelope if sent by mail and the subject line if sent by email or fax The intended Audience: clear statement about the intended recipient of the notice. Concise description of subject device, model/batch/serial number A factual statement explaining the reasons for the FSCA, including description of the problem A clear description of the hazards associated with the specific failure of the device and, where appropriate, the likelihood of occurrence, being mindful of the intended audience The recommended action(s) to be taken by the recipient of the Field Safety Notice including any action(s) recommended for people that have previously used or been treated by affected devices Where appropriate, include time frames by which the action(s) should be taken by the manufacturer and user. Designated contact point for the recipient of the Field Safety Notice to use to obtain further information. The notice may contain a request to inform customers/ or patients who received the product. If relevant, a request for the details of any affected devices that have been transferred to other organisations or have been destroyed to be given to the manufacturer so that follow up can take place and for a copy of the FSN to be passed on to the organisation to which the device has been transferred. 27 June 2006 Page 5 of 6

If relevant, a request that the recipient of the advisory notice alerts other organisations to which incorrect test results from the use of the devices have been sent. For example the failure of diagnostic tests. Manufacturers using a unique reference number to identify the FSCA should include this in the FSN; otherwise include a date (e.g. YYYY/MM/DD). The Field Safety Notice should NOT include any: comments and descriptions that downplay the level of risk any information that is intended to promote a manufacturer or their product s market visibility for the purposes of sales and marketing NOTE: manufacturer or product identifiers that enable or enhance product identification for the purposes of a field safety notice are not considered to be promotional material. 27 June 2006 Page 6 of 6