HAZARDS OF ELECTROMAGNETIC RADIATION TO ORDNANCE (HERO) CONCERNS DURING UXO LOCATION/REMEDIATION

Similar documents
Durable Aircraft. February 7, 2011

Electromagnetic Railgun

Remote Sediment Property From Chirp Data Collected During ASIAEX

Active Denial Array. Directed Energy. Technology, Modeling, and Assessment

A RENEWED SPIRIT OF DISCOVERY

Strategic Technical Baselines for UK Nuclear Clean-up Programmes. Presented by Brian Ensor Strategy and Engineering Manager NDA

THE CASE FOR SAFETY AND SUITABILITY FOR SERVICE ASSESSMENTS TO BE BASED ON A MANUFACTURE TO DISPOSAL SEQUENCE

INTEGRATIVE MIGRATORY BIRD MANAGEMENT ON MILITARY BASES: THE ROLE OF RADAR ORNITHOLOGY

THE NATIONAL SHIPBUILDING RESEARCH PROGRAM

Investigation of a Forward Looking Conformal Broadband Antenna for Airborne Wide Area Surveillance

UNCLASSIFIED UNCLASSIFIED 1

SA Joint USN/USMC Spectrum Conference. Gerry Fitzgerald. Organization: G036 Project: 0710V250-A1

RF Performance Predictions for Real Time Shipboard Applications

Modeling Antennas on Automobiles in the VHF and UHF Frequency Bands, Comparisons of Predictions and Measurements

CFDTD Solution For Large Waveguide Slot Arrays

Automatic Payload Deployment System (APDS)

Department of Energy Technology Readiness Assessments Process Guide and Training Plan

Report Documentation Page

Underwater Intelligent Sensor Protection System

Defense Environmental Management Program

Department of Defense Partners in Flight

Lattice Spacing Effect on Scan Loss for Bat-Wing Phased Array Antennas

Sky Satellites: The Marine Corps Solution to its Over-The-Horizon Communication Problem

Management of Toxic Materials in DoD: The Emerging Contaminants Program

U.S. Army Training and Doctrine Command (TRADOC) Virtual World Project

COM DEV AIS Initiative. TEXAS II Meeting September 03, 2008 Ian D Souza

August 9, Attached please find the progress report for ONR Contract N C-0230 for the period of January 20, 2015 to April 19, 2015.

Solar Radar Experiments

Non-Data Aided Doppler Shift Estimation for Underwater Acoustic Communication

Signal Processing Architectures for Ultra-Wideband Wide-Angle Synthetic Aperture Radar Applications

REPORT DOCUMENTATION PAGE

REPORT DOCUMENTATION PAGE. A peer-to-peer non-line-of-sight localization system scheme in GPS-denied scenarios. Dr.

FAA Research and Development Efforts in SHM

Technology Maturation Planning for the Autonomous Approach and Landing Capability (AALC) Program

Best Practices for Technology Transition. Technology Maturity Conference September 12, 2007

Radar Detection of Marine Mammals

Robotics and Artificial Intelligence. Rodney Brooks Director, MIT Computer Science and Artificial Intelligence Laboratory CTO, irobot Corp

Experimental Observation of RF Radiation Generated by an Explosively Driven Voltage Generator

AUVFEST 05 Quick Look Report of NPS Activities

Marine~4 Pbscl~ PHYS(O laboratory -Ip ISUt

Modeling an HF NVIS Towel-Bar Antenna on a Coast Guard Patrol Boat A Comparison of WIPL-D and the Numerical Electromagnetics Code (NEC)

Report Documentation Page

UNCLASSIFIED INTRODUCTION TO THE THEME: AIRBORNE ANTI-SUBMARINE WARFARE

EFFECTS OF ELECTROMAGNETIC PULSES ON A MULTILAYERED SYSTEM

GLOBAL POSITIONING SYSTEM SHIPBORNE REFERENCE SYSTEM

Munitions Safety - How Safe

USAARL NUH-60FS Acoustic Characterization

Coherent distributed radar for highresolution

Learning from Each Other Sustainability Reporting and Planning by Military Organizations (Action Research)

Modeling of Ionospheric Refraction of UHF Radar Signals at High Latitudes

Adaptive CFAR Performance Prediction in an Uncertain Environment

Characteristics of an Optical Delay Line for Radar Testing

Innovative 3D Visualization of Electro-optic Data for MCM

Passive Localization of Multiple Sources Using Widely-Spaced Arrays With Application to Marine Mammals

Effects of Radar Absorbing Material (RAM) on the Radiated Power of Monopoles with Finite Ground Plane

INFRARED REFLECTANCE INSPECTION

Satellite Observations of Nonlinear Internal Waves and Surface Signatures in the South China Sea

Measurement of Ocean Spatial Coherence by Spaceborne Synthetic Aperture Radar

LONG TERM GOALS OBJECTIVES

Bistatic Underwater Optical Imaging Using AUVs

THE NATIONAL SHIPBUILDING RESEARCH PROGRAM

Reduced Power Laser Designation Systems

Acoustic Monitoring of Flow Through the Strait of Gibraltar: Data Analysis and Interpretation

Loop-Dipole Antenna Modeling using the FEKO code

THE NATIONAL SHIPBUILDING RESEARCH PROGRAM

Modeling and Evaluation of Bi-Static Tracking In Very Shallow Water

DoDTechipedia. Technology Awareness. Technology and the Modern World

IREAP. MURI 2001 Review. John Rodgers, T. M. Firestone,V. L. Granatstein, M. Walter

DEVELOPMENT OF AN ULTRA-COMPACT EXPLOSIVELY DRIVEN MAGNETIC FLUX COMPRESSION GENERATOR SYSTEM

The Algorithm Theoretical Basis Document for the Atmospheric Delay Correction to GLAS Laser Altimeter Ranges

US AIR FORCE EarthRadar FOR UXO CLEANUP

FAST DIRECT-P(Y) GPS SIGNAL ACQUISITION USING A SPECIAL PORTABLE CLOCK

Synthetic Behavior for Small Unit Infantry: Basic Situational Awareness Infrastructure

Academia. Elizabeth Mezzacappa, Ph.D. & Kenneth Short, Ph.D. Target Behavioral Response Laboratory (973)

NEURAL NETWORKS IN ANTENNA ENGINEERING BEYOND BLACK-BOX MODELING

Acoustic Change Detection Using Sources of Opportunity

14. Model Based Systems Engineering: Issues of application to Soft Systems

Mathematics, Information, and Life Sciences

Ocean Acoustics and Signal Processing for Robust Detection and Estimation

A Multi-Use Low-Cost, Integrated, Conductivity/Temperature Sensor

Manufacturing Readiness Levels (MRLs) and Manufacturing Readiness Assessments (MRAs)

PULSED BREAKDOWN CHARACTERISTICS OF HELIUM IN PARTIAL VACUUM IN KHZ RANGE

Key Issues in Modulating Retroreflector Technology

Optimal Exploitation of 3D Electro-Optic Identification Sensors for Mine Countermeasures

Presentation to TEXAS II

Range-Depth Tracking of Sounds from a Single-Point Deployment by Exploiting the Deep-Water Sound Speed Minimum

David Siegel Masters Student University of Cincinnati. IAB 17, May 5 7, 2009 Ford & UM

VHF/UHF Imagery of Targets, Decoys, and Trees

NPAL Acoustic Noise Field Coherence and Broadband Full Field Processing

Effects of Fiberglass Poles on Radiation Patterns of Log-Periodic Antennas

INFRASOUND SENSOR MODELS AND EVALUATION. Richard P. Kromer and Timothy S. McDonald Sandia National Laboratories

3D Propagation and Geoacoustic Inversion Studies in the Mid-Atlantic Bight

Ground Based GPS Phase Measurements for Atmospheric Sounding

Validated Antenna Models for Standard Gain Horn Antennas

US Army Research Laboratory and University of Notre Dame Distributed Sensing: Hardware Overview

Diver-Operated Instruments for In-Situ Measurement of Optical Properties

Project Planning Considerations For Emerging Contaminants. Ed Corl NAVSEA LQAO

Advancing Autonomy on Man Portable Robots. Brandon Sights SPAWAR Systems Center, San Diego May 14, 2008

DARPA TRUST in IC s Effort. Dr. Dean Collins Deputy Director, MTO 7 March 2007

Combining High Dynamic Range Photography and High Range Resolution RADAR for Pre-discharge Threat Cues

Transcription:

HAZARDS OF ELECTROMAGNETIC RADIATION TO ORDNANCE (HERO) CONCERNS DURING UXO LOCATION/REMEDIATION Kurt E. Mikoleit Naval Surface Warfare Center, Dahlgren Division Dahlgren, Virginia ABSTRACT: As part of most Department of Defense (DOD) environmental cleanup efforts, subsurface contaminants such as unexploded ordnance (UXO) and hazardous waste, together with geologic features such as ground water and soil layer boundaries must be located. Many currently available subsurface detection systems being proposed for this work are electromagnetic (EM) emitting devices such as ground penetrating radars, terrain conductivity meters, borehole loggers, and metal detectors. NAVSEAINST 8020.7B currently prohibits these systems from being used on any Navy facility where ordnance is/may be present prior to a hazards of electromagnetic radiation to ordnance (HERO) safety analysis being performed. Unfortunately, many of the Naval personnel in charge of administering EPA mandated environmental clean up efforts are not aware of the safety regulations governing the use of EM emitting devices at Naval installations and the potential threat to remediation personnel and equipment. This paper will discuss applicable safety instructions, their application and limitations, and will present limited HERO safety data for several remote sensing instruments that have been evaluated. INTRODUCTION Currently, geophysical surveys are being planned and conducted by military/defense and contractor personnel at various Department of Defense (DOD) facilities. The goal of these surveys is to locate subsurface contaminants such as unexploded ordnance (UXO) and hazardous waste, together with geologic features such as ground water and soil layer boundaries. Almost all of these surveys require the use of electromagnetic (EM) emitting detection/location systems such as ground penetrating radars, air-borne radars, terrain conductivity meters, borehole loggers, and metal detectors. Also new Congressionally mandated programs have been initiated to design detection systems that will see deeper into the earth with greater accuracy. All of these active systems have the potential to unintentionally detonate, both current DOD ordnance inventory items as well as interred UXO. Subsequent detonation could kill personnel, damage/destroy equipment, and further contaminate soils with energetic material residue.

Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE AUG 1994 2. REPORT TYPE 3. DATES COVERED 00-00-1994 to 00-00-1994 4. TITLE AND SUBTITLE Hazards of Electromagnetic Radiation to Ordnance (HERO) Concerns During UXO Location/Remediation 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Naval Surface Warfare Center,Dahlgren Division,Dahlgren,VA,22448 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR S ACRONYM(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release; distribution unlimited 11. SPONSOR/MONITOR S REPORT NUMBER(S) 13. SUPPLEMENTARY NOTES See also ADM000767. Proceedings of the Twenty-Sixth DoD Explosives Safety Seminar Held in Miami, FL on 16-18 August 1994. 14. ABSTRACT see report 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT a. REPORT unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified Same as Report (SAR) 18. NUMBER OF PAGES 5 19a. NAME OF RESPONSIBLE PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18

BACKGROUND The Navy's Hazards of Electromagnetic Radiation to Ordnance (HERO) program addresses the potential for electromagnetic (EM) radiation to unintentionally initiate electroexplosive devices (EEDs) contained within current Navy and Marine Corp ordnance items. OPNAVINST 8023.2C assigns the Naval Sea Systems Command (NAVSEA) responsibility for the implementation of the Navy HERO program. NAVSEAINST 8020.7B establishes the requirement for the Director, Safety Division to review all planned transmitting and antenna installations afloat and ashore, including mobile and portable, and installations involving ordnance to ensure that potential HERO problem areas are identified. NAVSEA OP 3565 defines the HERO safety criterion, and lists the HERO classification of current Navy and Marine Corp ordnance items. The Naval Surface Warfare Center, Dahlgren Division (NSWCDD), Code F52, Dahlgren Virginia is the center of excellence for HERO within the Navy and has been performing HERO tests and analyses to verify system safety since 1959. These tests and analyses are performed on ordnance items in the stockpile to launch configuration of their life-cycle to the requirements defined in MIL-STD-1385B. In early 1992, as the geophysical survey requirements for the Installation Restoration Program (IRP) became apparent, NSWCDD, as part of its HERO responsibilities, initiated several efforts to address UXO susceptibility to EM radiation. The applicability of NAVSEA OP 3565 and MIL-STD-1385B in these instances is very limited. One effort involved developing a basic understanding of the potential HERO problems with interred UXO and the other was an investigation into the types of subsurface detection devices that could be used during geophysical site surveys. For EM emitting devices operational characteristics such as frequency, output power, antenna type, antenna gain, pulse width, and pulse repetition frequency of the various types of systems were identified. Many of these systems have very different operational characteristics than the EOD location devices currently and previously used for ordnance location. It soon became clear that the potential detection capabilities of ground penetrating radar (GPR) systems make this type of system a prime candidate for IRP geophysical surveys. Therefore some degree of emphasis was placed on investigating GPR systems. However, several other types of EM emitting survey systems such as metal detectors and ground conductivity sensors were also identified. An immediate observation was that many of these survey systems are battery powered and have low average radiated power, typically in the milliwatt, or less, range. However some systems, including GPRs, radiate short pulses at a high pulse repetition rates which produce higher average radiated power levels. The initial technical gut feeling was that these systems would pose no HERO safety problem (especially the low output power devices), but after the test and evaluation of several of these systems, this initial conclusion was found to be erroneous. Using the operational characteristics of typical detection devices, NSWCDD performed a quick-look analysis to determine if any of these systems could potentially present a HERO safety problem. The quick-look analysis covered four commercially available GPR systems operating at different frequencies, in different modulation modes, and with different output power levels. The analysis utilized some simplifying but not unrealistic assumptions of the antenna gain, soil attenuation, EED parameters, etc.. Results indicated that two of the systems produced power

densities, at one foot below the surface, which were well below the published HERO safety criteria. The third system produced power densities, at one foot, very close to the safety criteria. The fourth system, a high power version of the third system, produced power densities significantly above the safety criteria. Based on these conclusions, NSWCDD advised the Naval Facilities Engineering Command (NAVFAC, Code 18) and NAVSEA (Code 665) that a HERO safety review of all proposed survey systems which emit EM energy, for IRP and other environmental/geophysical investigations, should be conducted prior to use at sites which may contain UXO. NAVFAC requested that NAVSEA provide a technical point of contact for guidance in this area. NAVSEA directed NAVFAC to terminate the usage of EM emitting devices for IRP surveys until the effects of EM emitting devices on buried UXO is determined. NSWCDD, Code F52, has been designated by NAVSEA as the technical agent to assist in remedying this problem. To date, dissemination of this NAVSEASYSCOM safety directive has been very limited and no work has been initiated to resolve this potential safety issue. DISCUSSION The IRP and other environmental clean-up efforts may involve sites which contain interred UXO. NAVSEAINST 8020.7B currently prohibits EM emitting detection systems from being used on any Navy facility where ordnance is/may be present prior to a HERO safety analysis being performed. HERO safety criteria exist for current Navy/Marine Corp ordnance inventory items, but no such criteria exist for interred UXO. In many cases where geophysical surveys are required, the types of UXO present are unknown and the UXO may be structurally damaged. Additionally, conductive mixes may be decomposed, the EED circuit safety features may be degraded, and in most cases the UXO will be armed; all of which can potentially increase their susceptibility to EM radiation. Furthermore, the ordnance, is immersed in a soil medium whose conductivity and dielectric effects on the system susceptibility are unknown. NSWCDD proposed a program which, in part, would investigate the EM susceptibility levels of armed, damaged, and aged UXO with the objective of defining an appropriate safety criteria. To date the program has not been funded. To allow these systems to be used during environmental clean up efforts, an appropriate safety criteria and certification process must be defined. This safety criteria and certification process will eliminate most HERO safety concerns and expedite the HERO approval process for uncertified systems. The NAVSEA OP 3565 HERO UNSAFE ORDNANCE criteria is currently being utilized to evaluate specific EM emitting devices. However, the risk exists that this criteria may not provide an adequate safety margin for buried UXO. Passive, non-em emitting systems, such as the MK 12 and MK 26 systems, and acoustic systems currently in use for ordnance location do not present a HERO safety problem and therefore are exempt from the review requirement.

CURRENT ACTIVITY To provide an interim capability to evaluate the HERO safety of site survey systems, NSWCDD is using existing safety criteria. NSWCDD recognizes the risk that, because of the lack of data on the EM susceptibility of damaged and/or aged and armed UXO, these criteria may not be adequate. Therefore until further data is available, they should be treated as the minimum acceptable criteria. For frequencies above 100 khz, electric field environments such as those generated by GPR systems, the HERO UNSAFE levels of NAVSEA OP 3565 are used. The HERO UNSAFE category covers damaged ordnance and ordnance which has exposed wiring. In the absence of more appropriate criteria, buried UXO in an unknown, but probably altered and/or damaged state, must be considered as HERO UNSAFE. For frequencies below 100 khz, systems such as metal detectors and ground conductivity meters which magnetically induce eddy currents in conductive material, the general 16.5 db safety margin of NAVSEA OP 3565 is used for the criterion on induced currents (maximum no-fire current reduced by 16.5 db). The NSWCDD evaluation process for a proposed EM emitting survey system is a combination of measurement data and analysis results. All relevant information describing the emitted EM signal is obtained from published manufacturers literature and, in all cases to date, directly from technical discussions with the system design engineers. NSWCDD has found that the published literature generally does not contain sufficient information to perform an adequate HERO safety analysis. An analytic model of the nature of the EM emissions is developed and exercised to predict the appropriate EM effects as a function of victim (EED circuit) configuration and/or location. The analytical results are compared to experimental data obtained from direct measurements of the EM fields generated by the proposed survey system. These data consist of a set of measurements at different locations and orientations which can be compared to the analytical predictions. If there are discrepancies between the analytical results and the measured data, the model is reworked and measurements are retaken. When the analytical and experimental data are in general agreement, the magnitude of the analytic data is normalized to the measured data. To date three systems, none of which were GPR systems, have been evaluated for use during DOD IRP and other clean-up activities where the presence of UXO was suspected. A Fisher Model 1266-XB metal detector (similar to currently used EOD survey instruments) was certified for use with no restrictions. A Geonics Limited Model EM31-D non-contacting ground conductivity meter was certified for use in its normal operating mode (carried at hip height) but was specifically restricted from one potential operating mode (on the ground for maximum accuracy). Lastly, a Geonics Limited Model EM34-3 ground conductivity meter was restricted for use in its normal operating mode (on the ground) unless a different system (e.g. the certified Fisher Model 1266-

XBmetal detector) was used first to assure that there was no buried UXO within 1 meter of the surface of the earth. CONCLUSIONS Insufficient data exist on the EM susceptibility levels of damaged, aged, and armed UXO to define a high confidence HERO safety criteria. Analytical data exist, some of which has been validated with experimental measurements using the proposed survey systems, which show that existing HERO safety criteria could be violated when some systems are used in the vicinity of shallow buried UXO. Under these conditions, it would be an abrogation of NSWCDD's HERO safety responsibility and imprudent for the DOD not to require a HERO safety review of all uncertified active EM survey systems proposed for use at any sites where UXO may be present. RESOLUTION Immediately notify all DOD activities and environmental contractors of the potential HERO safety problems associated with using any EM emitting devices in close proximity to UXO (Naval Ordnance Center letter in process). Evaluate all uncertified EM emitting subsurface detection devices prior to use at sites which may contain UXO. Initiate a program to define an appropriate HERO safety criteria for UXO and all EM emitting devices. Review the HERO certification process for approved EOD EM emitting detection devices to ensure that all HERO safety requirements have been met.