Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Similar documents
Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-SDE

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDD.22

Electronic timer CT-TGD.22

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Three-phase monitoring relays

Electronic timers CT-S range Selection and ordering details

Electronic timer CT-SDS.22

Electronic timer CT-MFS.21

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Three-phase monitoring relay

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Analog signal converters CC-E I/I

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Three-phase monitoring relay

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relay CM-PFS

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PVE

Control module CP-A CM

Three-phase monitoring relays CM-PFE and CM-PFE.2

Three-phase monitoring relay CM-PBE

Liquid level monitoring relay CM-ENS.2x

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Switching power supplies CP range, Linear power supplies CP-L range. Content

Power supply CP-E 24/0.75

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Thermistor motor protection relays

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/2.5

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-D 24/1.3

Pluggable interface relays CR-P Pcb relays

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Electronic measuring and monitoring relays CM-range

Type CP-S, CP-C & CP-A Switch mode

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Analog signal converters CC range

Thermistor motor protection relays

Liquid level monitors and controls

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Power supply CP-D 12/2.1

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Control module CP-A CM

83 Series - Modular timers 16 A. Features

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Power supply CP-T 48/5.0 Primary switch mode power supply

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Power supply CP-T 24/20.0 Primary switch mode power supply

38 Series - Relay interface modules A

38 Series - Relay interface modules A

02/11/2015

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Power supply CP-T 48/20.0 Primary switch mode power supply

Subject to changes 11/2003 Page 1/7

CP-T range Product group picture

05/09/2012

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Multi-voltage Multi-function. Wiring diagram (without control signal)

Type Nominal voltage (V) Code HSV V

Transcription:

2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection 1 c/o contact Volt-free (dry) control contact Starting the time delay is possible - via an external control contact Pause timing / time storage is possible via an external control contact 2 LEDs for status indication Width 22.5 mm CT-AWS 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the pulse time 3 U/T: green LED - Supply voltage (LED flashes during timing) 4 R1: red LED - Output relay 1 energized 5 Circuit diagram 6 Marker label Approvals a culus b GL e GOST f CCC Marks g CE c C-Tick Order data Type Supply voltage Order code CT-AWS 24 V, 42-48V AC/DC, 110-240 V AC 1SVR 430 143 R0100 Order data (Accessories) Description Remote potentiometer 30.5 mm Remote potentiometer 22.5 mm Remote potentiometer 10.5 mm Adapter for screw mounting on panel Sealable cover Marker label Order code 1SVR 700 800 R1000 1SVR 701 800 R1000 1SVR 214 017 R0900 1SVR 430 029 R0100 1SVR 430 005 R0100 1SVR 366 017 R0100 Application The CT-S range timers are designed for use in industrial applications. They operate over a universal range of supply voltages and a large time delay range, within compact dimensions. The easy-to-set front-face potentiometers, with direct reading scales, provide accurate time delay adjustment. Operating mode The CT-AWS with 1 c/o contact offers 10 time ranges, from 0.05 s to 300 h for the adjustment of the pulse time. The time delay range is rotary switch selectable on the front of the unit. The fine adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the front of the unit. When an external potentiometer is connected to terminals Z1-, the internal adjustment is disabled and external adjustment is enabled. Timing is displayed by a flashing green LED labelled U/T. 1

Function diagram E Impulse-OFF (Trailing edge interval) This function requires continuous supply voltage at terminals A1/B1/B2-A2. Opening control contact -, energizes the output relay immediately and timing begins. The green LED flashes during timing. When the selected pulse time is complete, the flashing green LED turns steady and the output relay deenergizes. Closing control contact -, before the time delay is complete, de-energizes the output relay and the time delay is reset. Timing can be paused by closing control contact X1-. The elapsed time is stored and continues from this time value when X1- is re-opened. This can be repeated as often as required. When an external potentiometer is connected to terminals Z1-, the internal, front-face potentiometer is disabled and the time adjustment is made via the external potentiometer. A1/B1/B2-A2-15-18 15-16 X1- green LED t t 1 t s t 2 2CDC 252 053 F0205 t = adjusted pulse time t s = storage time t = t 1 + t 2 Connection diagram E CT-AWS A1 Z1 15 B1 X1 B1 A1 15 B2 A2 16 18 B2 18 16 A2 2CDC 252 114 F0005 Version: 1SVR 430 143 R0100 A1-A2 Supply: 110-240 V AC B1-A2 Supply: 24 V AC/DC B2-A2 Supply: 42-48 V AC/DC Z1- Remote potentiometer - Control contact to start timing X1- Control contact to pause timing 15-16/18 c/o contact 2

Wiring notes Connection diagram for remote potentiometer L1 A1 Z1 Z1 Z1 2CDC 252 277 F0205 A2 Potentiometer 50 k N Connection diagram for proximity switch (3 wire) with 230 V AC supply L1 L+ A1 230 V / AC 24 V / DC 2CDC 252 279 F0205 N A2 Proximity switch L- Connection diagram for proximity switch (3 wire) with 24 V DC supply L+ B1 2CDC 252 280 F0205 A2 Proximity switch L- Connection diagram for control contacts L1/L+ A1 X1 A2 X1 start timing X1 pause timing / time storage 2CDC 252 278 F0205 N/L- 3

Technical Data Input circuits Supply voltage A1-A2 110-240 V AC B1-A2 24 V AC/DC B2-A2 42-48 V AC/DC Power consumption 110-240 V AC approx. 2.5-12 VA 24 V AC/DC approx. 0.5 VA/W 42-48 V AC/DC approx. 1.8 VA/W Supply voltage tolerance -15...+10 % Supply voltage frequency AC/DC Version DC or 50/60 Hz AC Version 50/60 Hz Control contact connections volt-free (dry) - start timing external X1- time pause, time storage Minimum control pulse length 20 ms Non-load voltage at the control contacts 10-40 V DC (no galvanic separation to supply circuit) Max. current in the control circuit 1 ma Max. cable length to the control inputs 50 m Remote potentiometer connection Z1/Z3-50 kz Max. cable length to remote potentiometer 2 x 25 m, shield connected to potential Duty time 100 % Timing circuit Time ranges 0.05 s - 300 h 1) 0.05-1 s 2) 0.15-3 s 3) 0.5-10 s 4) 1.5-30 s 5) 5-100 s 6) 15-300 s 7) 1.5-30 min 8) 15-300 min 9) 1.5-30 h 10) 15-300 h Recovery time < 50 ms Repeat accuracy (constant parameters) < 0.2 % Timing error within the supply voltage tolerance range < 0.008 % / % d U Timing error within operating temperature range < 0.07 % / C Indication of operational states Supply voltage / timer output relay energized green LED steady / flashing while timing red LED Output circuits 15-16/18 Number of contacts Relays, 1 c/o contact Contact material AgCdO Related voltage acc. to VDE 0110, IEC 60947-1 250 V Maximum switching voltage 250 V AC, 250 V DC Rated switching current acc. to IEC 60947-5-1 AC-12 (resistive) 230 V 4 A AC-15 (inductive) 230 V 3 A DC-12 (resistive) 24 V 4 A DC-13 (inductive) 24 V 2 A Maximum lifetime mechanical 30 x 10 6 switching cycles electrical (AC-12, 230 V, 4 A) 0.1 x 10 6 switching cycles Short circuit proof, max. fuse rating n/c 10 A fast, operating class gl n/o 10 A fast, operating class gl General data Enclosure width 22.5 mm length 78.0 mm depth 100.0 mm Wire size fine-strand with wire end ferrule 2 x 0.75-2.5 mm 2 (18-14 AWG) fine-strand without wire end ferrule rigid 2 x 0.5-4 mm 2 (20-12 AWG) Weight approx. 150 g (5.3 oz) 4

Mounting position any Degree of protection enclosure / terminals IP50 / IP20 Temperature operating -20...+60 C storage -40...+85 C Mounting DIN rail (EN 50022) Standards Product standard IEC 61812-1, EN 61812-1 EMC Directive 89/336/EEC Electromagnetic compatibility IEC 61000-6-2, EN 61000-6-4 ESD acc. to IEC 61000-4-2, EN 61000-4-2 level 3 6 kv / 8 kv HF radiation resistance acc. to IEC 61000-4-3, EN 61000-4-3 level 3 10 V/m Burst acc. to IEC 61000-4-4, EN 61000-4-4 level 3 2 kv / 5 khz Surge acc. to IEC 1000-4-5, EN 61000-4-5 level 4 2 kv L-L HF line emission acc. to IEC 1000-4-6, EN 61000-4-6 level 3 10 V Low Voltage Directive 73/23/EEC Operational reliability acc. to IEC 68-2-6 4 g Mechanical resistance acc. to IEC 68-2-6 6 g Approvals / marks Approvals Marks culus, GL, GOST and CCC CE and C-Tick Isolation data Rated insulation voltage between supply circuit, acc. to VDE 0110, IEC 60947-1 supply up to 240 V: 300 V control circuit and output circuit supply up to 440 V: 500 V Rated impulse withstand voltage between all isolated circuits acc. to VDE 0110, IEC 664 4 kv / 1.2-50 µs Test voltage between all isolated circuits 2.5 kv, 50 Hz, 1 min. Pollution category acc. to VDE 0110, IEC 664, IEC 255-5 III/C Overvoltage category acc. to VDE 0110, IEC 664, IEC 255-5 III/C Environmental testing acc. to IEC 68-2-30 24 h cycle time, 55 C, 93 % rel., 96 h Load limit curves AC load (resistive) V V 300 200 100 80 60 50 40 30 20 2CDC 252 194 F0205 10 0.1 0.2 0.5 1 2 4 6 10 I A DC load (resistive) V V 300 200 100 80 60 50 40 30 20 2CDC 252 193 F0205 10 0.1 0.2 0.5 1 2 4 6 10 I A 5

Derating factor F for inductive AC load 1.0 0.9 0.8 F 0.7 0.6 0.5 2CDC 252 192 F0205 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Contact lifetime /switching cycles N N 10 5 9 8 5 4 3 2 10 4 1 2 3 4 5 6 7 8 I A 2CDC 252 191 F0205 220 V 50 Hz 1 AC 360 cycles/h Dimensional drawings Dimensions in mm 109,5 4.31 22,5.886 102 4.02 78 3.07 2CDC 252 188 F0005 100 3.94 Dimensional drawings (Accessories) ø36 DIA. 1.42 ø30 DIA. 1.18 1...7.39...2.75 2CDC 252 184 F0005 33 40 1.30 1.57 Remote potentiometer 30.5 mm ø29 DIA. 1.14 ø22 DIA..866 1...7.39...2.75 2CDC 252 183 F0005 33 42 1.30 1.65 Remote potentiometer 22.5 mm 6

3,5.138 50 max. 5 1.97 max.2 ø22 DIA..866 26 1.02 20.787 2CDC 252 182 F0005 Remote potentiometer 10.5 mm 4,5.177 62,5 2.46 11,5.453 10.394 22,5.886 2CDC 252 187 F0005 60 2.36 Adapter for screw mounting on panel 2.70 22,5.886 7.275 3,5.138 68,5 2CDC 252 185 F0005 front-to-back size 107 Sealable cover 3A11 20.787 8.315 2CDC 252 186 F0005 Marker label 7

Druckschrift-Nummer. 2CDC 111 024 D0201 Printed in the Federal Republik of Germany (08/05) ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Deutschland Postfach 10 16 80 69006 Heidelberg, Deutschland Internet http://www.abb.com/lowvoltage -> Control Products -> Electronic Relays E-Mail epr-support@stotzkontakt.de