C Series. Cool Surface System INSTRUCTION MANUAL FRONT VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

Similar documents
ProBuilder Linear CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

Contemporary Collection

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

U1500E Gas Fireplace

Contemporary Collection

MM700R Recess Box Kit Addendum

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

Accentra 52i Pellet Insert Zero Clearance Cabinet Part #

Regency Bellavista B41XT-1 Gas Fireplace

Contemporary Collection

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

Zero Clearance Fireplace 36 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Assembly Instructions

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles.

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS

HZO60 Outdoor Decorative Fireplace

ZERO CLEARANCE MANUAL

INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD. 100mm SLOPING CEILING FLUE KIT

General Installation Instructions LED

LE7000 Provincial Built-in (Zero Clearance) Kit Instructions.

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

INSTALLATION INSTRUCTIONS

SINGLE TRACK BYPASS (patent pending) barn door hardware

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Zero Clearance Fireplace 44 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Pop-Out Slim Video Wall Mount

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

WPS crew Doors Installation instructions

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

Installation Guide. Model #400. Corporate Office: 349 Highland Road East Macedonia, Ohio

MM750 Installation Instructions

Studio Face Xtreme 6020 Installation Instructions (Nickel , Black )

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual

Important Note. Tools Required: Welder capable of fully welding 10 GA.135 steel

GE Monogram. Installation. Instructions. Microwave Oven. Under Cabinet Installation. and. JX827 Series Built-In Kit. Models.

Installation Instructions Student 101 Fume Cupboard

Barn Door & Hardware Installation Guide

Installation Manual MODEL AE-46

6X3 Oscar Shed Assembly Manual

1 PREPARE HEADER AND ROUGH OPENING

Installation Instructions

I n s t a l l a t i o n S p e c i f i c a t i o n s

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

Dura-Lock Roof System

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY

Video Wall Installation Instructions 2W X 3H, 3W X 3H

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

ASSEMBLY INSTRUCTIONS DIY WALL BED KIT QUEEN BI FOLD DOOR CABINET & MECHANISM. Tools Required For Assembly. 6.5mm Masonry Drill Bit

Important Note. Tools Required: Welder capable of fully welding 10 GA.135 steel

Installation Instructions For Heavy Duty (FAS Models) and Median (FAM Models) Air Conditioners

Installation Instructions For Slider Casement Air Conditioners

TYPE "B" GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney.

Install Guide. view our Install video guide online

Please read these Installation Instructions in their entirety prior to installing or operating this equipment.

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Straight Stringer Installation Instructions

Simply lift up on the flexible cover to remove it from the radiator support panel and factory grille, exposing the upper mounting hardware.

Installation Instructions

BEFORE YOU BEGIN Read these instructions completely and carefully.

Installation and Assembly: Ceiling mount for LCD screens up to 29"

BARN DOOR HARDWARE KIT

6X3 Patio Garden Shed Assembly Manual

Why are we giving this guidebook as a FREE download?

Installation and Maintenance Manual IM 770-1

Answer Power Beam and Boundary Screen

MODELS: AE46, AE42, E46, E42, ANE46, ANE42, NE46, NE42

Sliding Door Hardware Installation Instructions ROB ROY

Ford Pocket Style Fender Flares Set of 4

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions

Privacy Wall Glass Selections - Polished Edge Slider Door

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

Installation Instructions

Small Projection port, Small View port Installation procedure

S H E D A S S E M B L Y I N S T R U C T I O N S

General Installation Instructions

Geberit Duofix. Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio

Instructions and best practices for installing the fitting along with ducting tips when using 4 flex duct

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

FOR WALL MOUNT WORKSTATION

ELECTRIC RANGE INSTALLATION MANUAL. Please read these instructions thoroughly before installing and operating the range.

INTERIOR DUCTWORK KIT

Chapter 18. Interior Doors

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Lightplane 3.5 Recessed

Cabinetry Installation

Transcription:

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE C Series Cool Surface System FRONT VENT [50-3463] INSTRUCTION MANUAL 4001609 This Cool Surface System has been tested for compliance to Standards: ANSI Z21.88-2014 and CSA Z2.33-2014. This Cool Surface System has been approved for use on the ENVIRO C34/44/60 Direct Vent fireplaces only and must be installed at the time of fireplace installation. The following instructions must be followed in conjunction with the fireplace installation instructions to comply with the standards and allow safe operation of the installed fireplace. Version Française: www.enviro.com/fr.html 50-3463 1

General Information The purpose of this optional Cool Surface System, or CSS, is to naturally re-direct the convective heat from the fireplace. Using this CSS lowers the temperatures of the front wall for installations where a TV, artwork etc. is desired directly above the fireplace. 2 The outlet of the CSS can be raised 1 higher up the front wall, within 4 of the room s ceiling, or ducted into a different 4 room for a cleaner front wall. Note: You can install the Cool Surface System without the Combustible Facing Kit. Doing so requires a non combustible facing material (see Owner s Manual for fireplace installation instructions). 5 3 Note: Dual Convection Fan Kit (50-3212) may not be used in conjunction with CSS. Prior to installation of the CSS make sure the desired location is large enough to comply with the combustible clearances of both the CSS and the fireplace (see Owner s Manual for fireplace installation instructions). Refer to the Framing and Clearances section of this manual for the required installation dimensions of the CSS. Please refer to Figure 1 and figure 2 to ensure that all CSS parts are accounted for and have not been damaged. Item Description Item Description 1 Main Duct Body 4 Outlet Trim Bezel 2 Right Standoff 5 Vent Collars 3 Left Standoff Figure 1. Cool Surface System Front Vent- Parts Diagram 4 1 vertical vent: The CSS has been designed to allow for installations where a vertical run of vent is required without having to jog the vent pipe around the CSS. The horizontal vent shield supplied with the fireplace is not required (see Owner s Manual) when vertically venting and the vent pipe can simply be run straight up through the cut out in the CSS. 2 2 3 Item Description Item Description 1 C34 Main Panel 4 Trimable Deflector 2 C44 Extension 3 C60 Extension Figure 2. Cool Surface System Combustible Facing Kit - Parts Diagram

Dimensions 9 3 8 " (23.8 cm) 2 3 4 " (7 cm) Standoff 11 7 8 " (30.2 cm) 2 1 2 " (6.6 cm) Standoff 40" (101.6 cm) 45" (114.3 cm) 31 3 4 " (80.6 cm) 1 2 " (1.3 cm) 3 1 2 " (8.9 cm) 2 5 8 " (6.7 cm) 7 5 8 " (19.4 cm) 25" (63.5 cm) 5" Vent Collars 2 1 8 " (5.4 cm) 7 3 8 " (18.7 cm) Figure 3. Cool Surface System Front Vent - Overall Dimensions 36.00 2.48 36.00 0.49 4.75 4.75 26.00 4.75 9.95 2.00 0.92 4.75 0.50 0.50 Figure 4. Cool Surface System Combustible Facing Kit Dimensions 3

Framing & Clearances Framing & Rough Opening: Refer to Figures 5 & 6 for the minimum allowable framing and rough opening of the CSS. CSS Outlet Min. Top and Bottom standoff = 2⅝ (6.7 cm) *All C Series* C34 45" (114 cm) 7 1/2" (2.5 cm) 2 x 4 (On Edge) 2 x 4 (On Edge) 37 1/4" (94.6 cm) Min. Height 4 Figure 5. C34 - CSS Framing & Rough Opening

Framing & Clearances C44 & C60 C60 = 71" (180 cm) C44 = 55" (140 cm) 45" (114 cm) Steel Stud - C60 Only 7 1/2" (2.5 cm) Steel Stud - C60 Only 2 x 4 (On Edge) 37 1/4" (94.6 cm) Min. Height Figure 6. C44/60 - CSS Framing & Rough Opening 5

Framing & Clearances Minimum Clearances - minimum vent: Shown below in Figure 7 are the minimum framing and clearances for the CSS when the fireplace is installed with the minimum allowable vent length: Min. Ceiling Clearance from top of CSS outlet = 4 (10.2 cm) Min. Ceiling Clearance in wall from top of CSS Body = 5⅝ (14.3 cm) CSS Body Min. Rear standoff = 2¾ (69.8 cm) 4" (10.2 cm) 5 5 8 " (14.3 cm) 80 (203 cm) Min. Ceiling 2 3 4 " (69.8 cm) Min. Vent 73 1 4 " (174.9 cm) Side Brace Min. Height 39 (99 cm) Min. Length 5 dia. flex vent (not supplied) 20" (50.8 cm) Min. Depth 6 Figure 7. CSS - Min. Framing & Clearances

Revised Mantel Requirements: Framing & Clearances Refer to Figure 8 for a combustible mantel installation, measurement is from bottom of the unit to the bottom of the mantel. If you are planning on installing a TV above the fireplace refer to page 10 to see the options available. Note: Minimum height of mantle if you intend on using a surround is 31 35 34 M A N T L E H E I G H T 33 32 31 30 29 4 MANTLE 8 MANTLE 12 MANTLE 28 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 M A N T L E D E P T H Figure 8: Minimum Mantel Height 7

Framing & Clearances Min. Height to Ceiling 55-1/16 (1399cm) 12 (305mm) 8 (203mm) 4 (102mm) 33 (84cm) 2-1/16 (75cm) 31 (79cm) Min. Height For Surround 29 (74cm) 8 Figure 9. CSS - Min. Framing & Clearances

Finished Opening: Framing & Clearances Combustible wall material i.e. drywall, shiplap etc. is permitted around the outlet of the CSS with a 3/8 (.95 cm) air gap required around the outside perimeter of the outlet. This creates a finished opening approx. 40¾ x 2⅞ (103.5 x 7.3 cm) in size (Figure 7). 2 7 8 " (7.3 cm) 3 8 " (1 cm) 40 3 4 " (103.5 cm) Figure 10. CSS - Outlet Finished Opening The supplied Outlet Trim Bezel, once installed, covers the air gap for a clean finished install (Figure 8). The Trim Bezel can be adjusted to accommodate finished walls ½ -1 (1.3-2.5 cm) thick and be painted to match the colour of the wall if desired (must be hi-temperature rated). Figure 11. CSS - Outlet with Trim Bezel 9

TV Installation Considerations: Installation Installation and service must be performed by a qualified installer, service agency or the gas supplier. If you are planning to mount a TV above your fireplace some considerations must be made to ensure it is protected from the heat. During testing temperatures did not exceed 121 F (49 C) midway up the front wall (Figure 12 & 13). There is no guarantee that these temperatures will not harm the longevity of your TV. Make sure to consult your TV manufacturer s specifications to find the maximum allowable operating temperature. Since every home and installation is unique, temperatures should be verified at the time of install if possible. If desired, front wall temperatures can be lowered to 104 F (40 C) with the use of a mantle (Figure 13). Refer to page 7 for revised mantle clearances. A TV should not be installed if temperatures exceed the manufacturers maximum allowable temperature. Above Ambient Height from Opening 29 F 41 Above Ambient 29 F 41 Height from Opening 29 F 35 21 F 35 29 F 29 21 F 29 27 F 23 35 F 17 Min. 2-1/2 (6.4cm) 24 F 23 17 F 17 10 Combustible Facing Kit TV must be 5 min from discharge if no mantle 1-1/2 Air Gap behind the TV. (Typically provided by a wall mount) 1/2 Combustible Base Material (Drywall) Up to 1 Combustible Material 38 F 11 49 F 5 Figure 12. CSS - TV Clearances 0 20 F 11 30 F 5 4 Mantle 29 from floor. 1/2 Combustible Base Material (Drywall) Up to 1 Combustible Material. Combustible Facing Kit Min. 2 (5cm) Gap Figure 13. CSS - TV Clearances 0 NOTE: You cannot install a Surround with the mantle at its lowest position. Install mantle at 31 for a Surround

Installation Duct Collars: Prior to fireplace installation, the two supplied duct collars must be attached to the top of the fireplace as shown in the steps below: Step 1: Using a T20 screwdriver, remove the inner and outer cover plates from the fireplace as shown (Figure 14). Each cover plate has four (4) mounting screws. Both sets of cover plates are no longer required and can be recycled. Retain eight (8) of the removed mounting screws to secure the duct collars. Outer Cover Plate (x2) Inner Cover Plate (x2) Duct Collars Figure 14. Cover Plate Removal Step 2: Attach the supplied duct collars to the top of the cabinet as shown (Figure 15). Secure the collars by re-using the eight (8) screws saved in the previous step. The fireplace is now CSS ready! Figure 15. Duct Collars Installed Side Supports / Standoffs: Prior to installation of the CSS the supplied set of side support/standoffs need to be attached to the sides of the main duct body. The side supports also incorporate the rear standoff as shown in figure 16. Side Support / Standoff Rear Standoff Using a T20 screwdriver and the supplied screws 6 screws (3 per side), attach the left support as shown in figure 16. Repeat for the right side support. Figure 16. CSS - Side Supports 11

Cool Surface System - Front Vent: Installation Step 1: Frame in the rough opening for the CSS as shown in Figures 5 & 6 (Pages 4,5) in the desired location following all required clearances as stated in the Framing & Clearances section. Note: Light coloured ceilings may slightly discolour near the outlet when it is installed at minimum clearance (4 / 10.2 cm). Increasing the ceiling clearance will help prevent this. Step 2: Using a T20 screwdriver, remove the screw on each side of the CSS outlet retaining the Outlet Trim Bezel and remove the Bezel (Figure 16). Step 3: Insert the assembled CSS into the framed rough opening by rotating it down slightly to allow the outlet and standoffs to pass through. When installed correctly the front flange of the top standoff should be up against the front face of the top stud (Figure 18). Step 4: Confirm the CSS is centered within the rough opening and secure in place using screws or nails through the four (4) holes along the top edge of the top standoff. Figure 17. Outlet Trim Bezel Screw Step 5: Secure the rear standoffs to support the remainder of the CSS ensuring it is level. If left unlevel, the outlet of the CSS will be out of square causing possible fitment issues with the Outlet Trim Bezel. Step 6: Install the fireplace in the desired location as directed in the Owner s Manual. Leave the front wall open for installation of the flex venting. Note: Flex venting must be non-insulated and listed to UL 1777 and ULC S635 standards Step 7: Connect the required lengths of 5 dia. stainless steel Figure 18. CSS - Top Standoff or aluminium flex vent (not supplied) between the collars on the fireplace and CSS. Secure the venting to the collars using either sheet metal screws or band clamps. Both collars on the CSS must be connected to the fireplace via 5 dia. flex vent. Secure the flex venting where necessary to maintain standard venting clearances: Table 1. Flex Vent - Minimum Clearances Vertical Pipe to the Side Walls 1 (25.4 mm) Horizontal Pipe to the Sides & Bottom 1 (25.4 mm) Above an Elbow Above the Unit 3 (76.2 mm) Above an Elbow Not Above the Unit 3 (76.2 mm) Above Horizontal Vent Pipe 2 (51 mm) 12

NOTE: If using the Combustible Facing kit, skip to end of page and install it now before proceding to the final steps. Step 8: Finish the front wall around the fireplace and CSS outlet as desired. Ensure the finished opening around the CSS outlet is as specified in the Finished Opening section of this manual. Installation 1 4 " (6.4 mm) Warning: CSS outlet MUST NOT be covered or blocked in any way by drapes, furniture etc. Step 9: Finally, install the Outlet Trim Bezel by sliding it into the outlet until the backside contacts the finished wall surface. Next, reinstall the two (2) screws removed in Step 2 Figure 19. Outlet Trim Bezel - Standoff to secure the Outlet Trim Bezel in place. When installed correctly there is a ¼ (6.4 mm) standoff between the back side of the Bezel and finished wall (Figure 19). Installation of the Cool Surface System is now complete and the remaining fireplace installation can be completed as directed in the Owner s Manual. Combustible Facing Kit (Optional): Note: You can install the Cool Surface System without the Combustible Facing Kit. Doing so requires a non combustible facing material (see Owner s Manual for fireplace installation instructions). Step 1: Prior to installation of the Combustible Facing Kit determine your unit. Retreive the trimable defelctor. The deflector is trimable to fit the unit being installed. It comes in the length required to fit a C60 and must be trimmed to fit either the C44 or the C34. Notches on the top and bottom of the trimable deflector show where to cut it. The first notch on the far left will size it for a C44 and the second notch will size it for a C34. As shown ins Figure 20 Figure 20. Trimmable Deflector trim notches 13

Combustible Facing Kit (Optional): Installation Step 2: All the Units use the C34 panel as a base. If installing a C44, use both the C34 and C44 panels. If installing a C60, use both the C34 and C60 panels. Once you have your required panels locate the flanges in the figure 21 below. Bend these flanges inwards 90deg to match the figure 21 below. Figure 21. Rear Panel hand bent flanges Step 3: Verify that all the hand bends shown above are bend inwards 90deg as shown in figure 21. Step 4: All the middle flanges must be bent 90deg inwards towards the unit as shown below in figure 22. Figure 22. Rear Panel hand bent flanges 14

Combustible Facing Kit (Optional): Installation Step 4: Make sure all your hand bend flanges are bent prior to assembly and that you have the correct length deflector before instalation to the unit. Step 5: If installing a C44 or C60, attach your extension piece to the C34 main panel. (Figure 24) Step 6: Remove the top cabinet T20 screws on the left and right side so that you can reuse them to fasten the Combustible Facing Kit asembly to the unit. Step 7: Use the provided self tapping screws to fasten the assembly via the remaining pilot holes on the front and top Step 8: Attach your deflector to your panel configuration as shown below (Figure 23, 24) Figure 23. Combustible Panel C34 Figure 24. Combustible Panels C44 Left, C60 Right 15

Combustible Facing Kit (Optional): Installation Before installing your chosen facing material, a 1/2 base layer must be placed over the framing up to the Combustible Facing Kit assembly as shown below. Up to a 1 thick material may be placed on top of the base layer and the combustible facing kit assembly afterwards. 1/2 Drywall 16 Figure 25. CSS - 1/2 Base Layer

Replacement Parts 2 1 3 Item Description Part Number 1 CSS Instruction Manual 50-3481 2 Outlet Trim Bezel 50-3307 3 Vent Collars (Set of 2) 50-3309 17

18 Notes

Learn more about our products at Detailed Product Lineup Model Photo Galleries Downloadable Manual PDF s Unit Comparison Charts Youtube Burn Example Videos Online Brochures Dealer Locator Tool 19

20 MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.enviro.com October 10, 2017 C-15204