RF leakage current in electrosurgical units: Influence of the layout in taking measurements

Similar documents
What tests should be done?

Andy Falconer. Principles of surgical diathermy

Electrosurgery Units (ESU s) and their variants

Electrosurgery Units (ESU s) and their variants. D. J. McMahon rev cewood

Application Notes. Electrosurgical Analyzer Primer

ESU-2000 Series Product Overview

QA-ES III Electrosurgical Analyzer

EXCELL NHP/T. A new step AheAd to the future ELECTROSURGICAL UNITS FOR MONOPOLAR AND BIPOLAR USE ISO ALSA IT ISO

ELECTROSURGICAL GENERATOR USER S GUIDE

QA-ES III Electrosurgical Analyzer

Electrosurgery. KLS Martin ME MB 2 SAFETY BY EASY USE

USER S GUIDE. User s Guide Bovie IDS-400

User s Guide Aaron 950

ALSATOM SU MPC SU 50 MPC SU 100 MPC SU 140 MPC SU 140/D MPC SU 140/BD MPC

RAISING THE LEVEL OF PROTECTION IN YOUR ORS

J-470 ELECTROSURGE. Radio Frequency Electrosurgery Unit. Operation Instructions

ELECTROSURGICAL UNIT ANALYZER

MICROWAVE DIATHERMY AND SURGICAL DIATHERMY DIATHERMICS

Electrosurgery. KLS Martin ME 102. The compact Electrosurgical Unit with high Capacity

QUICK SETUP GUIDE SECULIFE ESPRO

surtron.com SURTRON ELECTROSURGICAL units

WHALETEQ. ESU Neutral Electrodes Impedance Tester. Model: HFPA150. User Manual

BOVIE SURGI-CENTER PRO. Electrosurgical Generator. User's Guide

Operator s Manual E L E C T R O S U R G I C A L U N I T

HF- GENERATORS.

PULSAR Generator Operator s Manual

MINIMAL ENERGY. MAXIMUM PRECISION. 1,2, The newest addition to Valleylab energy made to enhance the performance of your electrosurgical handpieces1,2,

Electrosurgical Generator and Smoke Evacuation System Service Manual. Utah Medical Products, Inc. Catalog Numbers ESU-110 & ESU-220

Low / Medium Power Electrosurgery Review 2002

DERM 941 DERM 942 High-Frequency Desiccators

IEC Electrical fast transient / Burst immunity test

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe

PHYSIOFLOW Q-LINK TM

INSTRUCTIONS ESG-400

User s Guide Aaron 940

Meg1 (with Ligasmart)

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

Crossfire Footswitch. User Guide

ELEKTROTOM 505. Service Manual (E)

ARC 200 HF SURGICAL GENERATOR SIMPLY SAFE

LEEP System 1000 Table of Contents

Rigel 377. Instruction Manual 367A550 Issue 2.0. Electrosurgical Analyser. August Seaward Group Issue 2.0

ERBE ERBOTOM ICC 300. Instruction manual 08.00

Instruction Manual. (English-English)

Surge Coupling Decoupling Network (S-CDN) Considerations

perioperativecpd.com The basics of diathermy

D C 01/2019 3

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

AFBR-59F2Z Data Sheet Description Features Applications Transmitter Receiver Package

ERBE. ERBOTOM ICC 80 / 50 Instruction manual 08.00

3.7 Grounding Design for EAST Superconducting Tokamak

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

ELEKTROTOM 610. Operating Instructions. Valid from version 1130

The sensitivity test of 2.45GHz RFID active tag

HF-400. Electrosurgical Analyzer for function tests of HF Surgical Equipment

LC31L-BAT Link Coupler

An Alternative Technique to Perform Surgeriesin Hospital by Surgical Diathermy

DIGITAL LASER DISTANCE METER

MFJ-219/219N 440 MHz UHF SWR Analyzer TABLE OF CONTENTS

Aquamantys 3 Pump Generator User Guide. Revision F

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

GB / IEC/CISPR 11:2010

Rigel Medical 24 Month Warranty Statement

Surgitron Dual Frequency 4.0 MHz Radiowave Technology

Introduction to Medical Electronics Industry Test Analysis and Solution

USER MANUAL MHS-2500I. Please take time to read these instructions before starting to use the scale. Version /17

Testing for EMC Compliance: Approaches and Techniques October 12, 2006

U.S. ARMY MEDICAL DEPARTMENT CENTER AND SCHOOL FORT SAM HOUSTON, TEXAS ELECTROSURGICAL APPARATUS SUBCOURSE MD0363 EDITION 100

FDDI on Copper with AMD PHY Components

Innovating Together. An introduction to Electrosurgery

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

FISCHER CUSTOM COMMUNICATIONS, INC.

BAYLIS MEDICAL COMPANY RADIOFREQUENCY PUNCTURE GENERATOR RFP-100A

Monoblock Management Module (MMM)

OPERATING MANUAL ELECTROSURGICAL UNIT

Wideband resistive voltage divider for a standard wattmeter

BM VET 80, 120, 140, 180 W

Filter Considerations for the IBC

ICARUS ELECTRONIC GAS VOLUME CONVERTER

6. Internal lightning protection

Batteryless wireless transmission system for electronic drum uses piezoelectric generator for play signal and power source

PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet

Radio Frequency Electrosurgical System Specialist

HAWK5000 Operators Manual

Miniature resistance thermometer Model TR33, thread-mounted

Datasheet SHF D Synthesized Clock Generator

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax


Methods for Testing Impulse Noise Tolerance

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Q: What does it mean if the RF generator will not put out full power and the reflected power is nearly equal to forward power?

Overview of the ATLAS Electromagnetic Compatibility Policy

Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013

Cell Management Module (CMM)

MFJ-249B HF/VHF SWR ANALYZER

Technical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.

Course Introduction Purpose Objectives Content Learning Time

Transcription:

Journal of Physics: Conference Series RF leakage current in electrosurgical units: Influence of the layout in taking measurements To cite this article: L Gentile and P Palacios 2007 J. Phys.: Conf. Ser. 90 012043 View the article online for updates and enhancements. Related content - Evaluation of stray radiofrequency radiation emitted by electrosurgical devices M De Marco and S Maggi - The cutting mechanism of the electrosurgical scalpel Eda Gjika, Mikhail Pekker, Alexey Shashurin et al. - Tissue differentiation by means of high resolution optical emission spectroscopy during electrosurgical intervention Ines Bürger, Marcus Scharpf, Jörg Hennenlotter et al. This content was downloaded from IP address 148.251.232.83 on 13/04/2018 at 03:01

RF leakage current in electrosurgical units: Influence of the layout in taking measurements L. Gentile, P. Palacios Cardiology and Cardiovascular Surgery Institute, Favaloro Foundation Biomedical Engineering Department. Av. Belgrano 1746. Bs. As. Argentina E-mail: lgentile@ffavaloro.org Abstract. The RF leakage current in electrosurgical units is a critical parameter to measure, because it may cause accidental burns in patients. The particular standard for electrosurgical units IEC 60601-2-2 indicates the maximum RF leakage levels and defines the elements and their layout to do these measurements. On this paper we show the RF leakage current values of 6 electrosurgical units. We did these measurements in two different ways: in the first one we measured in normal conditions of use in the operating rooms and in the second we followed the mentioned Standard. The results shows differences between one group and the other, observing higher RF leakage current values in the measurements that we did without following the standard s layout. 1. Introduction The radiofrequency (RF) leakage current in electrosurgical units (ESU) is a critical parameter because it involves patients safety. This current flows from active and return electrodes to ground and may cause accidental patient burns. The standard IEC 60601-2-2 [1], particular requirements for the safety of high frequency surgical equipment, limits this parameter to a maximum of 4.5 W measured on a 200 Ω non inductive resistor for monopolar applications. RF leakage current measurement is one of the periodical inspections to do in ESU s [3], [4], because it will indicate a dielectric loss at the power output of these devices. On the other hand, measuring this parameter depends on many factors, such us the device and instrument layout, cables length, height respect to ground and so on. The IEC 60601-2-2 standard sets the instruments and ESU layout to do the RF leakage current measurement, as we show in Figure 1. The goal of setting this layout is to standardize the measurements and ensure repeatability. During functional inspections of ESUs its quite difficult to set the layout of the standard, because the measurements are usually done in the operating rooms where this devices operate. In this situation the ESU lays on a cart at a height different to the suggested by the Standard to do these measurements, and also the lay out of the instrument and the cables is random. In this work we try to quantify the effect of layout modifications when taking RF leakage current measurements, to determine if we must follow exactly the IEC 60601-2-2 layout or if we can directly take the measurements in the operating rooms without following a specific layout. c 2007 IOP Publishing Ltd 1

Figure 1. IEC 60601-2-2 measurement scheme 2. Methods and Materials For the achievement of the measurements we have used an ESU analyzer, model RF-302, manufactured from Biotek. We analized six Valleylab devices: three of them were Force FX model, and three Force 2. All the devices measured are showed in table 1, and their output features are showed in chart 2 y 3, for Force FX and Force 2 respectively. Leakage current measurements have made in two stages. First, we analized each ESU in the normal situation, inside an operation room, with the elements layout like it showed in figure. 2. Then, in the second stage, we have made the measurements with the devices placed in a test table, like IEC 60601-2-2 suggest. The elements layout are showed in figure.1 Figure 2. Out of norm measurement scheme Main differences between measurements in stage 1 and stage 2 are: height ESU to the floor, distance between wires and use of return electrode 2.1. Stage 1 In a normal situation of use inside the operating room in I.C.Y.C.C., we found each device on a stainless steel transport table at a height of 20 cm from the floor. In Each measurement, the RF-302 analyzer stayed on floor and connected to ESU using test wires and an active electrode Conmed, 2

like figure 2 shows. The location of wires was randomly, using another test wire to connect RF-302 to the ground connector placed on the wall. Return electrode to ground and active electrode to ground leakage RF Power was measured from monopolar output using a footswitch. The value was registered using all the available waveforms with the maximum power setup. This measure was called out of norm/rule measurements, because we don t respect the device height, distance between wires and the use of return electrode. Table 1. Electrosurgical units information Name Trademark Model Serial number ESU 1 Valleylab Force FX F5J42368A ESU 2 Valleylab Force FX F5J42380A ESU 3 Valleylab Force FX F5J42389A ESU 4 Valleylab Force 2 F2C17574T ESU 5 Valleylab Force 2 F7C31701T ESU 6 Valleylab Force 2 F7I32747T Table 2. Waveforms, maximum power output and voltage values for Valleylab Force FX. Mode Waveform Max.Power @300Ω Max. voltage Cut Low 300 W 1350 Vpp Cut Pure 300 W 2300 Vpp Cut Blend 200 W 3300 Vpp Coag. Dessicate 120 W 3500 Vpp Coag. Fulgurate 120 W 8500 Vpp Coag. Spray 120 W 9000 Vpp 2.2. Stage 2 In the second stage we measured each device on a test table like IEC60601-2-2 suggests. Fig.1 shows the location of the elements. For connections between ESU and analyzer we used test wires with 4mm plug and croc clips to connect the return electrode. The return electrode used was a disposable split electrode, 3M model 9160F. The measurement instrument (RF-302) used was the same for both stages. 3

3. Results Comparing the measurements done in stages 1 and 2 for return and active electrodes RF leakage current, we can see differences between them. The average and standard deviation are (stage 1 and 2, in this order): Return leakage current [W]: 7.333 ± 1.514; 2.875 ±1.242 Active leakage current [W]: 3.166 ± 0.970; 2.333 ±0.996 We have done a statistic analysis with the T Student test [5] in which we saw a significative difference (p<0.05) between the measurements done in stages Nº1 and Nº2 for return electrode leakage current. For the active electrode leakage current measurements to ground, although the average value is greater in the measurements taking out of norm, there isn t enough statistics evidence to confirm that this difference is significant (p<0.05) In figure 3 and figure 4 we show the highest values measured in both conditions for each 6 ESUs, for return and active leakage current. Etapa Nº2 Etapa Nº1 Etapa Nº2 Etapa Nº1 Potencia [W] 10 9 8 7 6 5 4 3 2 1 0 ESU 1 ESU 2 ESU 3 ESU 4 ESU 5 ESU 6 Potencia [W] 10 9 8 7 6 5 4 3 2 1 0 ESU 1 ESU 2 ESU 3 ESU 4 ESU 5 ESU 6 Figure 3. Return electrode RF leakage power Figure 4. Active electrode RF leakage power 4. Discussion The measurement s results show a significant difference between the values when modifying the ESU s height respect to ground, the cable s length and their layout. In all the cases we measure a higher RF leakage current when taking them in the operating room conditions. In the RF return leakage current measures without following the Standard s conditions, the values we obtained were higher than the maximum allowed by the IEC 60601-2-2 Standard, which is 4.5 watts. On the other hand, when we repeated the measurements following the Standard s layout of the elements involved (ESU, measuring instrument and cables) we obtained all of the values in the allowed range regardless one of the unit (ESU 6), in which the leakage current measured following the Standard is quite higher than the maximum allowed level. (5 watts). 4

When we analyzed the facts of the active electrode s measurements leakage current, we observed that measuring with the IEC layout, the devices have a RF leakage below the maximum level. Measuring with a different layout (stage 1, called out of norm ), we observed that the leakage levels increased in all cases, like it happened measuring from return electrode. Table 3. Waveforms, maximum power output and voltage values for Valleylab Force 2. Mode Waveform Max.Power @300Ω Max. voltage Cut Pure cut 300 W 3500 Vpp Cut Blend 1 250 W 3800 Vpp Cut Blend 2 200 W 4000 Vpp Cut Blend 3 200 W 4000 Vpp Coagulation Coag. 120 W 7000 Vpp 5. Conclusions RF leakage current measurement in this kind of devices is an important parameter that gives information about its safety. We can see an important difference in the measurements according to the layout of the different elements involved. It is necessary to count with a standard procedure to do these measurements, in which the effects of the layout be constant and don t interfere with the desired measuring parameter. Based on the results of this work, measuring RF leakage power in normal conditions of use, will give higher values. Doing this we may consider that an ESU is out of the highest allowed RF leakage because we are doing a wrong procedure. We recommend that to do this kind of measurements you must follow the layout suggested by the IEC 60601-2-2 standard. 6. Appendix We will next describe the elements of figure 1: 1. Main supply 2. Isolated table 3. ESU 4. Active electrode 5. Neutral or return electrode 7. Measuring resistor, 200Ω 8. RF meter 9. Conductive surface connected to ground 5

7. References [1] International Standard IEC 60601-2-2. Medical electrical equipment. Particular requirements for the safety of high frequency surgical equipment. Fourth edition 2006 [2] Bio-tek electrosurgery analyzer RF 302. User s guide.1991 [3] Valleylab Force FX-C, electrosurgical generator. Service manual. 1999 [4] Valleylab Force 2, electrosurgical generator. Service manual. 1991 [5] Montgomery D and Runger C, Applied statistics and probability for engineers, Third edition 2003 6