Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR

Similar documents
IDM 61/62T Instruction Digital Multimeter Manual

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

IDM 98-III & IDM 99-III Digital Multimeters

Instruction Manual IDM 66RT Digital Multimeter

IDM 503 & 505 Digital Multimeters

Instruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES

Safety Information. WARNING Identifies hazardous conditions and actions that could cause BODILY HARM or DEATH

Instruction Manual IDM 503 & IDM 505 Digital Multimeters IDM 505

ICM 136R Operating Instruction Electrical Clamp-Multimeter

INSTRUCTION MANUAL IDM17 PEN-TYPE MULTIMETER

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

# Digital Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

Instruction Manual IDM 103N/105N/106N Digital Multimeter EN FR IT

Electrical Multimeter

Instruction Manual IPM φ/1φ Power Clampmeter EN FR IT DE ES

600A Clamp Meters w/tightsight Display

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

200Amp AC Clamp Meter + NCV Model MA250

UT207A/208A/209A Operating Manual. Table of Contents

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

DM-45 Digital Multimeter

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

1.General instructions Specifications Description...7

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

Digital Clamp Meter Model: &

312, 316, 318. Clamp Meter. Users Manual

BENNING. CM7 Electrical Tester. Service Information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

DDM350 Pen-Type Digital Multimeter User s Manual

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

USER'S MANUAL DMR-6700

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

NOTE: Fully read and understand this manual before using this Digital Multimeter.

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

CONTENTS MS2033A. 1.Introduction Safety Information...01

Sales: Technical: Fax:

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

MS8223A. CAT.IIi 600 V

User s Guide. 400A AC/DC Clamp Meter. Model MA220

79/26 Series III Multimeter

15B & 17B. Users Manual. Multimeters

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

KMD-S04 Multímetro de bolsillo

Autoranging Multimeter Extech EX503

400Amp True RMS AC Clamp Meter + NCV

AMM-1022 Digital Multimeter USER`S MANUAL

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

NI 71/72. Multimeter. Manual

MS2030 CAT III 600 V A V AUTO RS232

DVM1190 DIGITAL MULTIMETER

Instruction Manual IDM 103N/105N/106N Digital Multimeter EN FR IT

Pen Multimeter. Model

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

374/375/376 Clamp Meter

12B/18 MultiMeter Instruction Sheet

15B & 17B. Multimeters. Users Manual

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Table of Contents Title Page

netzerotools.com 374/375/376 Users Manual Clamp Meter

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

True RMS Digital Multimeter Model:

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

User Manual Digital Clamp Multimeter. model no.: MSR-C600

374/375/376 Clamp Meter

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

400Amp True RMS AC/DC Clamp Meter Model EX613

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Data sheet IDM 98III Digital Multimeter

Dawson DDM190. Digital Multimeter User s Manual

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

Data sheet IDM 99III Digital Multimeter

Electrical Multimeter

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

374 FC/375 FC/376 FC Clamp Meter

Model 77 Series IV. Digital Multimeter. Users Manual

MODEL: D03128 CLAMP METER

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

OPERATOR S INSTRUCTION MANUAL

DMM8900 SERIES USERS MANUAL

DIGIT & POINTER MULTIMETER

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User Manual. All rights reserved. Specifications are subject to change without notice.

Model UT201/202: OPERATING MANUAL. Table of Contents

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

DM-46 Instruction Manual

Transcription:

Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR

Safety Information Read and understand this Instruction Manual completely before using this instrument. Failure to observe the warnings and cautions in this Instruction Manual may result in injury or death, or damage to the instrument and other equipment or property. If this instrument is used in a manner not specified in these instructions, the protection provided by the instrument may be impaired. WARNING - Examine the instrument and probes before use. Do not use the instrument if it is wet or damaged. - When using test leads or probes, keep your fingers behind the finger guards. - Remove the test lead from the instrument before opening the battery cover or instrument case. - Always use the correct terminals, switch position and range for measurements. - Never attempt a voltage measurement with the test leads inserted into the A input terminals. - Verify the instrument is operating correctly by measuring a known voltage before use. If in doubt, have the instrument serviced. - Do not apply more than the rated voltage, as marked on the instrument, between terminals or between any terminal and earth ground. - Do not attempt a current measurement when the open-circuit voltage is above the fuse protection rating. - Only replace a blown fuse with the correct type and rating as specified in this Instruction Manual. - Use caution when measuring voltages above 30 Vac rms or 60 Vdc. These voltages pose a shock hazard. - To avoid incorrect readings that can lead to electric shock, replace the battery as soon as low battery indicator appears in the display. - Disconnect the circuit power and discharge all high-voltage capacitors before making resistance, current, continuity, diode or capacitance measurements. - Do not use the instrument in a Hazardous Area or around explosive gasses or vapours. - Wear suitable Personal Protective Equipment when working around or near hazardous Live conductors which could be accessible. EN - 2

Caution - Disconnect the test leads from the test points before changing the position of the function rotary switch. - Never connect the instrument to a source of voltage with the function rotary switch in Ω/ / A //Hz position. - If possible, do not work alone, so assistance can be given if required. - Do not expose the instrument to extremes of temperature or high humidity. - Never set the instrument to the A function to measure the voltage of a power supply circuit, as it may result in damage to the instrument and the equipment under test. The following symbols may appear on the instrument and in this Instruction Manual : Risk of electric shock Refer to Instruction Manual Direct Current (dc) Equipment protected throughout by double or reinforced insulation Battery Fuse Earth Alternating Current (ac) Conforms to applicable EU directives Maintenance Do not attempt to repair this Instrument. It contains no user-serviceable parts. Repair or servicing should only be performed by qualified personnel. This instrument should be calibrated yearly, or more frequently if used in harsh conditions or if it is suspected of being inaccurate. For calibration and repair contact RS Components - the address is given at the end of these instructions. Cleaning Periodically wipe the case with a damp cloth and detergent. Do not use abrasives or solvents. EN - 3

Measuring AC/DC Voltage and Frequency Continuity and Diode Test Bad Diode Red Black Red Black Good Diode Red Black Red Black EN - 4

Resistance and Capacitance Measurement (Capacitance for 62T only) Note To improve the measurement accuracy of a small value capacitor, record the reading with the test leads open circuit, then substrate the residual capacitance of the Instrument and leads from the final measurement. C UNKNOWN = C MEASUREMENT - C RESIDUAL MIN MAX Record (For 62T only) EN - 5

Measuring DC / AC Current (For 62T only) Disconnect Temperature C, F DCV R EN - 6

Display Hold Manual Ranging and Auto Ranging Auto Power-off (Battery Saver) 10 min EN - 7

Disable Auto Power-off Non-Contact Voltage Sensing (VoltSense) NCV 1. The VoltSense function will operate irrespective of the position of the function rotary switch, including the OFF position. 2. Remove the test leads from the instrument as they are not used for the VoltSense test. 3. Press and hold the VoltSense button. The LCD display will go blank, a tone will sound and the red LED will illuminate momentarily to confirm the instrument is operational. 4. Hold the Volt sense button down and move the instrument over the area where detection is required. The buzzer will sound and the LED will illuminate when a live conductor is detected. Release the VoltSense button to return to normal operation. EN - 8

Fuse Replacement (For 62T only) WARNING Disconnect the test leads from the circuit and the instrument before removing the rear cover. Caution Use only a replacement fuse of the type and rating given in the specifications. Refer to the following figure to replace the fuse : Battery Replacement When the low battery indicator "" appears on the LCD, replace the batteries with the type given in the specifications. WARNING Disconnect the test leads from the circuit and the instrument before removing the battery cover. Refer to the following figure to replace the batteries : EN - 9

Specifications General Specifications Display : 2000 counts. Polarity Indication : Automatic, positive implied, negative indicated. Overrange Indication : OL or -OL. Batteries Life : 250 hours approx with Alkaline cells. Low Batteries Indication : is displayed when the battery voltage drops below the minimum operating voltage. Auto Power Off : Approx 10 minutes after last operaton. Storage Temperature : -20 to 60 C (-4 F to 140 F) @ 0 to 80% R.H. with the battery removed from the instrument. Operating Ambient : Non-condensating, 10 C (50 F) ; 11 to 30 C (51.8 F to 86 F) @ 80% R.H; 31 to 40 C (87.8 F to 104 F) @ 75% R.H; 41 to 50 C (105.8 F to 122 F) @ 45% R.H. Measurement Category (Installation Category) per IEC 61010-1:2001: V/Ω: CAT.III. 600V, CAT.II. 1000V. A: CAT.III. 600V (for 62T only) Pollution Degree 2 Measurement Category l is for measurements performed on circuits not directly connected to mains. Examples include: Measurements on battery powered equipment and specially protected (internal) mains-derived circuits. Measurement Category ll is for measurements on circuits directly connected to the low voltage installation. Examples include: Household appliances, portable tools and similar equipment. Measurement Category lll is for measurements performed in the building installation. Examples include measurements on distribution boards, junction boxes, socket-outlets and wiring and cables in the fixed installation. Measurement Category lv is for measurements performed at the source of the low-voltage installation. Examples include measurements on primary overcurrent protection devices and electricity meters. EN - 10

Temperature Coefficient : 0.27 x Spec. Accy / C <18 C or >28 C; (0.15 x Spec.Accy / F,< 64.4 F or > 82.4 F). Power Requirements : Qty. 2 x 1.5V Alkaline type AA batteries. Fuse (For 62T only) : 10mmx38 mm 10Amp 600V ac/dc HBC, Littlefuse KLKD10 or equivalent. Dimensions (W x H x D) : 74mm x 156mm x 44mm Accessories : Battery (installed), Test leads and user manual. Measurement rate : Sampling rate 2 times per second nominal. Altitude : 6561.7 ft (2000m) Safety : Complies with EN61010-1:2001, UL61010-1:2001 and IEC 61010-1:2001. Weight : (320g) including battery. Electrical Specifications Accuracy is ±(% reading + number of digits) at 23 C ± 5 C < 80%RH. DC / AC Volts Range 200.0mV * AC Accuracy Unspecified 2.000V * ±(1.5%+5dgt) 50Hz ~ 300Hz 20.00V ~ 200.0V * 750V AC / 1000V DC ±(1.5%+5dgt) 50Hz ~ 500Hz * DC Accuracy : ±(0.5% + 2dgt) Over voltage protection : 1000V DC or 750 V ACrms. Input Impedance : 10MΩ // less than 100pF. * CMRR / NMRR : (Common Mode Rejection Ratio) (Normal Mode Rejection Ratio) V AC : CMRR > 60dB at DC, 50Hz / 60Hz V DC : CMRR > 100dB at DC, 50Hz / 60Hz NMRR > 50dB at DC, 50Hz / 60Hz AC Conversion Type : Average sensing rms indication. AC conversions are ac-coupled, true rms responding, calibrated to the sine wave input. * The minimum LCD reading is 1400 count in Auto Ranging Mode. Crest Factor : C.F. = Peak / Rms + 1.5% addition error for C.F. from 1.4 to 3 + 3% addition error for C.F. from 3 to 4 EN - 11

DC / AC Current (For 62T only) Range DC Accuracy AC Accuracy Voltage Burden 2.000A 10.00A ** ±(1.0% + 3 dgt) ±(1.5% + 5 dgt) 50Hz ~ 500Hz * 2V max Overload Protection : A input : 10A (600V) fast blow fuse * AC Conversion Type : Conversion type and additional specification are same as DC/AC Voltage. ** Ampere Testing Duty Ratio Table Ampere Testing Time Rest Time 10A 4min 10min 9A 5min 10min 8A 7min 10min 7A 10min 10min 6A Continually N/A Resistance Range Accuracy Voltage Burden 200.0 ~ 200.0KΩ ** ±(0.7% + 3 dgt) 2.000MΩ ** 20.00MΩ * ±(1.0% + 3 dgt) ±(1.5% + 3 dgt) 2V max Open circuit Voltage : -1.3V approx. * <100 dgt rolling. EN - 12

Diode Check and Continuity Range Resolution Accuracy 10 mv ±(1.5% + 5 dgt)* * For 0.4V ~ 0.8V Max.Test Current : 1.5mA Max. Open Circuit Voltage : 2V Overload Protection : 600V rms. Frequency (For 62T only) Range Sensitivity Accuracy 2000Hz ~200.0KHz >1.5 Vac rms, <5 Vac rms Frequency : 2.000MHz ~ 20.00MHz >2 Vac rms, <5 Vac rms 0.01%±1digit Overload Protection : 600V rms. Minimum pulse width : >25 ns Duty cycle limits : >30% and <70% Capacitance (For 62T only) Range 2.000nF ~ 200.0µF 2.000mF * Accuracy ±(1.9% + 8 dgt) Overload Protection 600V rms * < 10 dgt of reading rolling. Temperature ( C ) (For 62T only) Temperature Accuracy Overload Protection -20 C ~ 0 C ±(2% + 4 C ) 1 C ~ 100 C ±(1% + 3 C ) 101 C ~ 500 C ±(2% + 3 C ) 600V rms 501 C ~ 800 C ±(3% + 2 C ) EN - 13

Temperature ( F ) (For 62T only) Temperature Accuracy Overload Protection -4 F ~ 32 F ±(2% + 8 F) 33 F ~ 212 F ±(1% + 6 F) 213 F ~ 932 F ±(2% + 6 F) 600V rms 933 F ~ 1472 F ±(3% + 4 F) Limited Warranty This instrument is warranted to the original purchaser against defects in material and workmanship for 3 year from the date of purchase. During this warranty period, RS Components will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not cover disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. RS Components shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you. For full terms and conditions, refer to the current RS Catalogue. EN - 14

Asia Iso-Tech 460 Alexandra Road, #15-01A PSA Building Singapore 119963 USA 7410 Pebble Drive Fort Worth Texas 76118-6961 Europe Iso-Tech PO Box 99 Corby Northamptonshire NN17 9RS United Kingdom Canada 1701 Woodward Drive Ste 108 Ottawa Ontario K2C 0R4, Canada Japan West Tower (12th Floor) Yokohama Business Park 134 Godocho, Hodogaya Yokohama, Kanagawa 240-0005 Japan South America Av. Pdte. Eduardo Frei M. 6001-71 Centro Empresas El Cortijo Conchali, Santiago, Chile