Ceramax CPS341D. Technical Information

Similar documents
Memosens CPS96D. Technical Information

Orbipac CPF81/CPF82 and CPF81D/CPF82D

Technical Information Orbipore CPS91D and CPS91

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

Condumax W CLS15 and CLS15D

Condumax CLS15 and CLS15D

Technical Information Memosens CPS96D

Condumax CLS16 and CLS16D

Condumax CLS21 and CLS21D

Technical Information Memosens CLS82D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax CLS21 and CLS21D

Condumax CLS15 and CLS15D

Condumax W CLS15 and CLS15D

Memosens New technology for contactless, inductive, digital transmission of ph signals

Indumax CLS50/CLS50D. Technical Information

Technical Information Condumax CLS15D/CLS15

Technical Information Condumax CLS21D/CLS21

Indumax CLS54D. Technical Information

Tophit CPS491 and CPS491D

Technical Information Smartec CLD18

Tophit CPS441 and CPS441D

Technical Information Smartec CLD18

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Turbimax CUS71D. Technical Information. Ultrasonic interface sensor Immersion sensor for interface measurement

Technical Information Smartec CLD18

Technical Information Indumax CLS50D/CLS50

Tophit CPS491 and CPS491D

Technical Information Indumax CLS54

Smartec S CLD134. Technical Information

Technical Information Memosens CCS50D

Liquisys M CPM223/253

ph / ORP Measurement mypro CPM 431

Indumax H CLS54. Technical Information

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

The transducer component converts the measured signal and displays the actual value.

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

Flow Measurement SITRANS F M

prosonic T FMU230, FMU231

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Inductive Conductivity Meter ILM

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

OPTISENS ORP 8590 Technical Datasheet

SMARTPAT PH 1590 Technical Datasheet

Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13

Digital inductive conductivity transmitter

Measuring and Controlling Unit Multronic

Measuring and Controlling Unit Multronic OC

ph/orp Measurement OPM223/253

Ambient Conditions. Operating Conditions. Pressure

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

ph or ORP Transmitter

OPTISENS PH 8390 Technical Datasheet

Conductivity measurement SmarTec S CLD 132

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

Temperature Sensor with M12 hygienic

Electromagnetic Flow Transmitter

Temperature Sensor with M12 hygienic

Digital ORP sensor for the water and wastewater industry

Conductivity sensor for hygienic applications

Signet ph/orp Electrodes General Purpose

ABB ph/orp analyzer and probe package

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

0 2 1 â Ó. itemp HART TMT182. Technical Information

Bulb ph and ORP Electrodes

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

OPTISENS PH ph sensor. Technical Datasheet

Pharma Temperature Sensor G3/8"

RMA42. Technical Information

Pharma Temperature Sensor G3/8"

IsFET sensor for ph Measurement TopHit CPS 491

SMARTPAT COND 1200 Technical Datasheet

B Operating Instructions V1.00/EN/

BATCHFLUX 5500 C Technical Datasheet

SMARTPAT ORP 8510 Technical Datasheet

Conductivity Transmitter

Pharma-Temperature Sensor M12 hygienic

OPTIFLUX 5000 Technical Datasheet

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Digital ORP sensor for the industrial wastewater industry

Technical Information Liquisys M CLM223/253

omnigrad M TR 46 Technical Information Hygienic in-line RTD thermometer PCP ( ma), HART or PROFIBUS-PA electronic

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

Conductivity measurement

Technical Information OUSBT66

Electro-Magnetic Flowmeters COPA-XE

Temperature Sensor with G1/2" hygienic

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

OPTISENS PH 8100 Technical Datasheet

Signet ph/orp Electrodes

OPTIFLUX 5000 Technical Datasheet

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Ultrasonic level transmitter, non-contact

Digital conductivity transmitter

Sterilizable IsFET sensor for ph Measurement TopHit CPS 441

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Transcription:

Technical Information Ceramax CPS341D Electrode with ph sensitive enamel and digital Memosens technology Meets highest demands of measuring accuracy, pressure, temperature, sterility and durability Application Food production, also highly pasty media Beverage production and filling Quality control Pharmaceutical industry: Water treatment Active ingredient production Active ingredient preparation Fermentation Biotechnology Your benefits Continuous online measurement is possible in the ongoing process Direct installation in container nozzles or piping Self-cleaning by the flowing medium Long-term stability over many years High mechanical loading capacity due to a steel substrate Extremely corrosion-resistant to acids Hygienic design: Inline CIP and SIP-capable Further benefits offered by Memosens technology Maximum process safety through contactless inductive signal transmission Data safety through digital data transmission Easy handling thanks to storage of sensor-specific data in the sensor Predictive maintenance possible thanks to registration of sensor load data in the sensor TI468C/07/EN/06.10 71114968

Function and system design Measuring principle General properties Durability and calibration cycles Important properties Data storage ph measurement The ph value is a measure of the acid or base character of a medium. Depending on the ph value of the medium, the electrode's ph-sensitive enamel provides an electrochemical potential. This is the result of H + ions selectively penetrating the outer layer of the enamel. As a result, an electrochemical boundary layer forms here with an electric potential. An integrated Ag/AgCl reference system forms the required reference electrode. The transmitter converts the measured voltage into the corresponding ph value according to the NERNST equation. Mechanical stability The substrate of the sensor is steel. That makes the sensor mechanically stable when confronted with solids and turbulent flows from agitators. To protect the steel from corrosion and product deposits, it is covered with highly resistant enamel. Working electrode The working electrode consists of yellow, ph-sensitive enamel that is melted onto a large area of the lower end of the sensor in the shape of a ring. This ensures an area many times larger compared to ph glass electrodes or ISFET sensors. The working electrode is connected directly to the metallic reference lead. An inner buffer is not necessary. Reference electrode The Ag/AgCl reference electrode is integrated into the head of the sensor. A sterile 3M KCl solution is used as an electrolyte. This also contains an inhibitor that prevents the reference from aging and thus enables the long operating life. The electrolyte CPS341Z-D5 is delivered in PE bottles with septum and simply used in the stainless steel electrolyte vessel CPS341Z-D1. The conductive connection between reference and medium guarantees a shrunk, aseptic ground joint diaphragm. The pressure in the reference system must be continuously above the operating pressure. Easy installation The sensor is installed, without a basket protector or additional assembly, directly in container nozzles or in the main stream of piping. The orientation can be selected at random. The sensor remains in the process room permanently, even in empty containers. The sensor is factory-calibrated and ready for measurement immediately after being connected to a transmitter with Memosens functionality. Due to the mechanical design, aging of the sensor is very minor and there is no measuring error. In most applications it is sufficient for the sensor to be adjusted once a year with a sample calibration. Maximum process safety The inductive and non-contacting measured value transmission of Memosens guarantees maximum process safety and offers the following benefits: All problems caused by moisture are eliminated. The plug-in connection is non-contacting and therefore free from corrosion. Measured value distortion from moisture is not possible. The plug-in system can even be connected under water. The transmitter is galvanically decoupled from the medium. The result: No more need to ask about "symmetrically high-impedance" or "unsymmetrical" (for ph/orp measurement) or an impedance converter. EMC safety is guaranteed by screening measures for the digital measured value transmission. Data safety through digital data transfer The Memosens technology digitalizes the measured values in the sensor and transfers them to the transmitter contactlessly and free from interference potential. The result: An automatic error message is generated if the sensor fails or the connection between sensor and transmitter is interrupted. The availability of the measuring point is dramatically increased by immediate error detection. Communication with the transmitter Always connect digital sensors to a transmitter with Memosens technology. Data transmission to a transmitter for analog sensors is not possible. The sensor is connected to the cable connection (CYK10) without contact. The power and data are transferred inductively 2 Endress+Hauser

Once connected to the transmitter, the data saved in the sensor are read digitally. You can call up these data using the corresponding DIAG menu. Data that digital sensors save include the following: Manufacturer data Serial number Order code Date of manufacture Calibration data Calibration date Calibration values Number of calibrations Serial number of the transmitter used to perform the last calibration Operational data Date of commissioning Hours of operation under extreme conditions Number of sterilizations Data for sensor monitoring. Measuring system A complete measuring system comprises: Ceramax CPS341D ph sensor Transmitter, e.g. Liquiline CM42 CYK10 measuring cable 1 3 2 Measuring system 4 CM42 transmitter 3 CYK10 measuring cable 2 CPS341D ph sensor a0013857 Input Measured variables Measuring range ph value Temperature 0 to 10 ph (linear range) -2 to 14 ph (application range) 0 to 140 C (32 to 280 F) Endress+Hauser 3

Installation Installation position CPS341D can be installed in any position. 0... 360 Fig. 1: Installation position a0013862 Environment Ambient temperature range Storage temperature Degree of protection The sensor must not be used at temperatures below 0 C (32 F). 0 to 50 C (32 to 120 F) IP 68 (10 m (33 ft) water column, 25 C (77 F), 45 days, 1 M KCl) Electromagnetic compatibility Interference emission and interference immunity as per EN 61326: 2006 Process Process temperature Process pressure Minimum conductivity ph range 0 to 140 C (32 to 280 F) 0 to 6 bar (0 to 87 psi) 50 μs/cm -2 to 14 ph 4 Endress+Hauser

Mechanical construction Dimensions Dimensions a0013874 Weight Material Process connections Temperature sensor Reference system 600 g (1.3 lbs) Sensor body: Porcelain enamel metal substrate (PEMS), chemically resistant and shock resistant Adapter and plug-in head: Stainless steel 1.4404 (AISI 316 L), PVDF, PTFE Electrolyte vessel: Stainless steel 1.4301 (AISI 304) Process connection adapters: Stainless steel 1.4404 (AISI 316 L) M20 Pg 13.5 3/4" 1" Nozzle, DN25 Nozzle, DN30 Varivent DN50/40 Dairy pipe DN50 Dairy pipe DN25 Triclamp DN50 NTC 30KΩ Ag/AgCl with 3 M KCl and inhibitor Endress+Hauser 5

Ordering information Product structure Version 7 Basic Application range A 0 to 10 ph, 0 to 140 C (32 to 280 F), 0 to 6 bar (0 to 87 psi) Process connection adapter 1A Without 1B M20 1C Pg 13.5 1D 3/4" 1E 1" 1F Nozzle DN25 1G Nozzle DN30 1H Varivent DN50/40 1K Dairy pipe DN50 1L Dairy pipe DN25 1M Triclamp, compatible to DN50 Approval 1 Non-Ex area CPS341D- complete order code Accessories In the following sections, you find the accessories available at the time of issue of this documentation. For information on accessories that are not listed here, please contact your local service or sales representation. CPS341Z Correct function of Ceramax CPS341D depends on reliable supply of KCl to the reference part of the sensor. The pressurized electrolyte vessel CPS341Z-D1 is best suited for this. The electrolyte supply can be monitored by the ultrasonic sensor for level monitoring CPS341Z-D2 (air bubble sensor). The ultrasonic sensor requires a supply voltage of 18 to 30 V DC at a max. of 70 ma (without switching current). The signal is output via the relay CPS341Z-D4 as well as optically via the LED display CPS341Z-D3. A1 A2 A3 A4 D1 D2 D3 D4 D5 D6 D7 D8 Accessories for Ceramax CPS341D Welding nozzle DN30, straight Dummy plug for welding nozzle DN30 Welding nozzle DN25, straight Welding nozzle DN25, inclined Electrolyte vessel, stainless steel Ultrasonic sensor level monitoring Cable with LED display Relay, type KCD2-R, P+F KCl electrolyte, sterile, 1 l plastic bottle Purified water, sterile, 1 l plastic bottle Plastic bottle, empty Protection cap CPS341Z- To obtain a valid order code, simply attach the optional features to the order code. If you have any questions, please contact our sales office. Transmitters Liquiline CM44x Multiple-channel transmitter for the connection of digital sensors with Memosens technology Power supply: 85 to 265 V AC, 18 to 36 V DC or 20 to 28 V AC (not CM448) Universally upgradeable SD card slot Alarm relay IP 66 Ordering acc. to product structure (Technical Information TI444C/07/en) 6 Endress+Hauser

Liquiline CM42 Modular two-wire transmitter for Ex and non-ex areas Hart, PROFIBUS or FOUNDATION Fieldbus available Ordering acc. to product structure, Technical Information TI381C/07/en Mycom S CPM153 Transmitter for ph and redox, one or two channel version, Ex or Non-Ex HART or PROFIBUS available Ordering acc. to product structure, Technical Information TI233C/07/en Buffer solutions High-quality buffer solutions of Endress+Hauser - CPY20 The secondary buffer solutions have been referenced to primary reference material of the PTB (German Federal Physico-technical Institute) and to standard reference material of NIST (National Institute of Standards and Technology) according to DIN 19266 by a DKD (German Calibration Service) accredited laboratory. ph value A ph 2.00 (accuracy ± 0.02 ph) C ph 4.00 (accuracy ± 0.02 ph) E ph 7.00 (accuracy ± 0.02 ph) G ph 9.00 (accuracy ± 0.02 ph) I ph 9.20 (accuracy ± 0.02 ph) K ph 10.00 (accuracy ± 0.05 ph) M ph 12.00 (accuracy ± 0.05 ph) Quantity 01 20 x 18 ml (0.68 fl.oz) only buffer solutions ph 4.00 and 7.00 02 250 ml (8.45 fl.oz) 10 1000 ml (0.26 US gal) 50 5000 ml (1.32 US gal) canister for Topcal S Certificates A Buffer analysis certificate Version 1 Standard CPY20- complete order code Measuring cables CYK10 Memosens data cable For digital sensors with Memosens technology Ordering according to product structure, see Technical Information (TI376C/07/en) Endress+Hauser 7

Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI468C/07/EN/06.10 71114968 FM9