CALEC ST II BACnet MS/TP

Similar documents
IF96014 BACnet COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement

Nemo D4-L+ BACNET COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement. Date: March, 30 th 2012 Vendor Name:

BAS Integration Manual

Electronic pressure-independent characterised control valve with energy monitoring

Sensor BACnet PICS. Contents. 1. Operating elements for addressing and parametrization 2 2. Protocol Implementation Conformance Statement - PICS 3

Electronic pressure-independent characterised control valve with energy monitoring

EPC3000 Programmable Controller

Multi-protocol heating and cooling energy calculator

Choose from our wide range of volume-measuring elements. Our advisers will be pleased to help you select the right ones for your needs.

BACnet Protocol Implementation Conformance Statement

USB BACNET COMMUNICATION OPTION MANUAL

Belimo Gateway MP to BACnet MS/TP - UK24BAC

BAC-IO9 BACnet MS/TP Input / Output Modules, Wall Mounted

USB BACNET COMMUNICATION OPTION MANUAL

Communicative heating and cooling controller, BACnet MS/TP UB200. Summary

BACnet Protocol Implementation Conformance Statement

RF-RXS-B SonNet Wireless Receiver BACnet IP

Output AC L /DC + Power In AC C /DC - Btu ENERGY METER Model: 340 BN/MB S/N Power Out Signal - Sensor Input. Input LED.

TR150 Embedded BACnet Operating Instructions

BACnet communication module for TCX2: AEX-BAC

SRC-110 Series Zone Controllers. BACnet MS/TP. Product sheet CT2.143 SRC-110-BAC

BACnet Integration Manual

BACnet Option Module Instruction Manual

PIR Ready SE7200, SE7300 & SER7300 Series

CALEC ST Innovative solutions in energy measurement

Output AC L /DC + Power In AC C /DC - Btu ENERGY METER Model: 340 BN/MB S/N Power Out Signal - Sensor Input. Shield. Input LED.

MINI and MIX Series I/O modules

Operating Instructions

DTS BACnet MSTP Map Version 3.2U TABLE OF CONTENTS

BACnet communication module for TCX2: AEX-BAC

SKDESC-xB Series Electronic Steam Controller

GE Consumer & Industrial Electrical Distribution. AF-600 FP TM BACnet. Operating Instructions

Supercal 531 Multi function Integrator that lives up to Your highest expectations

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

SAFETY PRECAUTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

MPS PROFIBUS-DP INTERFACE

PIR Ready VT72xx & VT(R) 73xx Series 24 Vac Fan Coil and Zoning Thermostats For Commercial and Lodging HVAC Applications

N30P DIGITAL PANEL METER

Introduction to BAS Technology

Communication. Versatronik 532 & 532D Solar Communication Gateway for solar controls Modbus. Technical, Installation and Configuration Information

EVCB14NIT4X. BACnet Communication Module User Guide

Type EM-IP BACNET/IP INTERFACE, MODBUS/IP INTERFACE, AND WEBSERVER FOR EASYLAB CONTROLLERS AND TAM ADAPTER MODULES

ULTRASONIC D. Compact ultrasonic heat meter

BACnet PTEC Controller Dual Duct 2 AVS - Constant Volume with Two Inlet Sensors and Optional Reheat, Application 6665

User Guide. EVCB14NIT4X-V410-BACnet Guide-EUA docx

Metasys Integrator ESAM E as VND device Application

PLA 33. Power line analyzer. User and service manual. version 2.4

B850 Boiler House Energy Monitor

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

The wireless alternative to expensive cabling...

Installation & Operation Manual

Microprocessor Gas and Steam Flow Computer Energy Flow Computer (Consumption and Enthalpy for Steam) Series: DigiFlow Type: 515

Excel 800 / Excel Web II CABLE SPECIFICATIONS

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

Operating manual for the electronic transmitter UMC3-FF with Foundation-Fieldbus interface

Modbus communication module for TCX2: AEX-MOD

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

Tip 65: Position control with MICROMASTER420 frequency converter

B850 Boiler House Energy Monitor

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

UTM10 Series Ultrasonic Transit-time Flowmeters

Energy Management Energy Meter Type EM340

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

P/N: AX Ordering Part Numbers: SAE J1939 Controller: For baud rate, refer to the table below for the appropriate P/N. Mating Plug Kit: AX070123

BACnet PTEC Controller VAV with CO2 Monitoring, Parallel Fan and AOV or Floating Point Heating, Application 6682

SolarEdge Feed-in Limitation Application Note

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Sales and Engineering Data Sheet ED

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

AG FB-CAN. Absolute encoder viva CAN. Product Manual E-V0204.doc

UN2 - Universal controller Building automation s missing link

SUPPLY NETWORK ANALYZER CVM-96 SERIES

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

HEAT CALCULATOR MODEL 212

PEM353. Universal measuring device

The wireless alternative to expensive cabling...

E8950 NOTICE WARNING. Modbus-to-BACnet Protocol Converter INSTALLATION GUIDE SPECIFICATIONS PRODUCT IDENTIFICATION PRODUCT OVERVIEW

A Super trainer with advanced hardware and software features only found in very expensive equipment.

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/

Din-Mon Smart Meter. Advanced kwh/demand Meters with Communication INSTALLATION INSTRUCTIONS

TOSVERT VF-PS1 series BACnet option unit Instruction Manual BCN001Z

RAY COMPACT ENERGY METER MECHANICAL

Bulletin B1243: RIBTW24B-BCAI RIBMNW24B-BCAI

Monitoring Relays. 3RS10, 3RS11 Temperature Monitoring Relays. Relays, analog adjustable 7/55

ServoPac-A TTA-PRO Positioner

Micronics U1000MKII-HM

SONOMETER TM 1100 Ultrasonic compact energy meter

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Digital Multifunction Meter - RISH Integra 2000

EIG DNP V3.0 Protocol Assignments

IBM Platform Technology Symposium

Energy Management Energy Analyzer Type EM112

RAY MC COMPACT ENERGY METER MECHANICAL

AHRI Standard Standard for Performance Rating of Modulating Positive Displacement Refrigerant Compressors

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

Gas Fired Humidifier SKG Series

Transcription:

Communication description Page 2 9 CALEC ST II BACnet MS/TP Table of contents 1 General information... 2 1.1 Content... 2 1.2 Definition... 2 1.3 Registered trademark and brand names... 2 1.4 Certification according to BACnet standard... 2 2 Hardware... 3 2.1 Communication interface... 3 2.2 Line termination... 3 3 Commissioning... 4 3.1 Commissioning of CALEC ST II with the BACnet MS/TP interface... 4 3.2 BACnet Baud rate... 4 3.3 BACnet MAC address... 4 3.4 Master/slave mode... 4 3.5 Device instance number (DIN)... 4 3.6 Device object name... 5 3.7 Location... 5 3.8 Description... 5 4 CALEC ST II BACnet services and objects... 5 4.1 Supported BACnet services... 5 4.2 Supported BACnet objects... 6 5 BACnet connections, e.g. with water and oil meters... 9 6 Alarm... 9 7 PICS document... 9 8 Troubleshooting... 9 VD 3-125b e 03.2018

1 General information 1.1 Content This communication description includes only specific information about CALEC ST II with the BACnet MS/TP module. Further information is available in the technical documentation of CALEC ST II. Additional documents can be found on the following website: http://www.integra-metering.com/qr/prod/calec-st/11111.html General information about BACnet can be found at www.bacnet.org. 1.2 Definition BACnet is a globally accepted, open standard (ISO Standard 16484-5) in building automation. BACnet assures the inter-operability between devices of different manufacturers. CALEC ST II with BACnet MS/TP interface allows an integration in BACnet networks without using gateways. The physics of RS485 interface is used for transmission. 1.3 Registered trademark and brand names BACnet, as well as the BACnet logo are registered trademarks of ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) in Atlanta, GA (USA). 1.4 Certification according to BACnet standard CALEC ST II with the BACnet MS/TP module is certified according to the following test standards: Test standards ISO 16484-5:2014 ANSI/ASHRAE 135-2012 Addendum ai to ANSI/ASHRAE 135-2012 Addendum al to ANSI/ASHRAE 135-2012 Addendum ar to ANSI/ASHRAE 135-2012 Addendum as to ANSI/ASHRAE 135-2012 Addendum ay to ANSI/ASHRAE 135-2012 Addenda an, at, au, av, aw, ax, and az to ANSI/ASHRAE 135-2012 ANSI/ASHRAE 135.1-2013 Addendum o to ANSI/ASHRAE 135.1-2013 BTL Test Plan 14.0 BTL Specified Tests 14.0 BTL Checklist 14.0 2 CALEC ST II

2 Hardware 2.1 Communication interface INTEGRA METERING AG uses a communication interface defined by BACnet technology with twisted-pair wiring (2-core). CALEC ST II: Overview of supported functions Function Parameter Value description More information Manufacturer ID 431 - This identification is valid for INTEGRA METERING AG and Aquametro AG Data protocol BACnet MS/TP - - BACnet device profile B-ASC - - MAC address 0...127 master and slave 0...254 slave Factory setting: the last 2 digits of the device serial no. Master/slave setting: Changeable via CALEC ST II operating menu. Factory setting: master See: Chapter 3.4 Master/slave mode Baud rate 9600, 19200, 38400, 57600, 76800, 115200 Automatic adjustment See: Chapter 3.2 BACnet Baud rate Device instance number - The last 5 digits of the device serial no. See: Chapter 3.5 Device instance number (DIN) BACnet connection type - RS-485-2.2 Line termination A termination resistor must be connected to both ends of the segment. The technical BACnet MS/TP specifications recommend a 120 Ohm resistor. If CALEC ST II is at the end of a segment, the internal termination resistor can be activated. Operating menu: BAcnEt TRm CALEC ST II 3

3 Commissioning 3.1 Commissioning of CALEC ST II with the BACnet MS/TP interface After connecting the RS-485 cable with the terminals 90a(+) and 91b(-), the following steps need to be performed: Step-by-step instructions Step Action Description 1 Configuration of CALEC ST II for use of application The respective information can be found in the operating instructions of CALEC ST II. 2 Configuration of CALEC ST II for BACnet use According to this description The relevant bus number for the configuration results from the assembly of the BACnet interface in socket # 1 or socket # 2. 3.2 BACnet Baud rate The baud rate adjustment of CALEC ST II will be set automatically after connecting the BTU meter to the network. Supported baud rates are 9600, 19200, 38400, 76800 and 115200. If the Baud rate is changed at the master system during operation, CALEC ST II needs to be restarted. 3.3 BACnet MAC address The BACnet MS/TP MAC address can be changed in the operating menu of CALEC ST II. The applicable range of the BACnet MS/TP MAC address lies between 0 and 254 (for master functionality between 0 and 127, for the slave functionality between 0 and 254). The differentiation between master and slave address range is defined via the operating menu in the menu Mod of CALEC ST II. Operating menu: BAcnEt Adr 3.4 Master/slave mode By means of the BACnet MS/TP mode selection the mode behaviour of CALEC ST II can be selected as master or slave. After 30 seconds the change is active. Operating menu: BAcnEt Mod 3.5 Device instance number (DIN) The device instance number can be changed in the operating menu of CALEC ST II. The last 5 digits of the serial number (CALEC ST II) are the factory setting for the DIN. Operating menu: BAcnEt DIN 4 CALEC ST II

3.6 Device object name The parameter object-name can be overwritten (standard: Calec ST II BACnet ) 3.7 Location The parameter location can be overwritten (standard: No Location set ) 3.8 Description The parameter description can be overwritten (standard: CALEC BTU METER ) 4 CALEC ST II BACnet services and objects 4.1 Supported BACnet services CALEC ST II is a BACnet Application Specific Controller (B-ASC) and supports the following services: BACnet Interoperability Building Blocks (BIBB s) Data Sharing - ReadProperty - B Data Sharing - ReadPropertyMultiple - B Data Sharing - WriteProperty - B Data Sharing WritePropertyMultiple - B Data Sharing - COV - B Device Management - Dynamic Device Binding - B Device Management - Dynamic Object Binding - B Device Management - DeviceCommunicationControl - B Device Management - TimeSynchronization - B Device Management - UTCTimeSynchronization - B Device Management - ReinitializeDevice - B DS-RP-B DS-RPM-B DS-WP-B DS-WPM-B DS-COV-B DM-DDB-B DM-DOB-B DM-DCC-B DM-TS-B DM-UTC-B DM-RD-B CALEC ST II 5

4.2 Supported BACnet objects CALEC ST II with BACnet MS/TP supports the following device objects and variants and their analog inputs. The analog inputs are made available according to the respective device variants. Analog inputs Object no. Designation Volume Mass Flow BDE TGR BDV DTF AI-0 Energy X X X X X X AI-1 Energy-BDE X X X X AI-2 Volume X X X X X AI-3 Volume-BDE X X X AI-4 Mass X AI-5 Auxiliary counter 1 X AI-6 Auxiliary counter 2 X X X X X X X AI-7 Auxiliary counter 3 X X X X X AI-8 Power X X X X X X AI-9 Volume flow X X X X X X AI-10 Mass flow X AI-11 Temperature warm X X X X X X AI-12 Temperature cold X X X X X X AI-13 Temperature difference X X X X X X AI-14 Density X X X X X X AI-15 Energy-TGR X Binary outputs Object no. Designation Volume Mass Flow BDE TGR BDV DTF BO-0 Relay 1 X X X X X X X BO-1 Relay 2 X X X X X X X 6 CALEC ST II

4.2.1 Supported BACnet units of current values CALEC ST II with BACnet MS/TP supports the following units for current values: Energy and Energy-BDE/TGR units Volume and Volume-BDE units Unit BACnet Enum Unit BACnet Enum J 16 cft 79 kj 17 m 3 80 kj/kg 125 Imp.gal. 81 MJ 126 L 82 Wh 18 US.gal. 83 kwh 19 MWh 146 BTU 20 kbtu 147 MBTU 148 thm 21 Th 22 Mass units Unit kg 39 lb 40 Tons 41 BACnet Enum 4.2.2 Supported BACnet units of the auxiliary counters 1...3 The selectable units depend on the setting of the auxiliary counter in CALEC ST II. Energy-related Volume-related Unit BACnet Enum Unit BACnet Enum J 16 cft 79 kj 17 m 3 80 kj/kg 125 Imp.gal. 81 MJ 126 L 82 Wh 18 US.gal. 83 kwh 19 MWh 146 BTU 20 kbtu 147 MBTU 148 thm 21 Th 22 Mass-related Without unit Unit BACnet Enum Unit BACnet Enum kg 39 Without unit 95 lb 40 Tons 41 CALEC ST II 7

4.2.3 Supported BACnet units instant values CALEC ST II with BACnet MS/TP supports the following units for instant values: Power units Volume flow units Unit BACnet Enum Unit BACnet Enum mw 132 cft/s 142 W 47 cft/min 84 kw 48 m 3 /s 85 MW 49 m 3 /min 165 BTU/h 50 m 3 /h 135 kbtu/h 157 Imp.gal./min 86 PS 51 l/s 87 RT 52 l/min 88 l/h 136 US.gal./min 89 Mass flow units Temperature units Unit BACnet Enum Unit BACnet Enum g/s 154 C 62 g/min 155 K 63 kg/s 42 F 64 kg/min 43 kg/h 44 lb/s 119 lb/min 45 lb/h 46 Tons/h 156 Temperature difference units Unit BACnet Enum K 63 8 CALEC ST II

5 BACnet connections, e.g. with water and oil meters There are two auxiliary inputs available to measure pulses from other meters, such as water and oil meters with pulse signals and to directly communicate the result to the BACnet MS/TP network. 6 Alarm CALEC ST II status messages are linked with the BACnet objects. INTEGRA METERING AG differs between the following types of status messages: Device status error All important device errors such as system error need to be verified including their error codes. Measurement value status alarm : Specific messages such as dt alarm have to be verified (further information can be found in the section Error messages, alarms in the operating instructions of CALEC ST II). 7 PICS document The PICS document of CALEC ST II can be found at www.integra-metering.com. Additional documents can be found on the following website: http://www.integra-metering.com/qr/prod/calec-st/11111.html 8 Troubleshooting Communication errors No. Error / malfunction Possible reason Correction 1 CALEC ST II is not communicating in the BACnet MS/TP network 2 After changing the Baud rate on the master system, CALEC CALEC ST II is not communicating via BACnet MS/TP anymore Wiring of the network Terminating resistors Configuratin of CALEC ST II Configuration of BMS CALEC ST II is unable to automatically recognise the set Baud rate Check if the BACnet MS/TP devices are correctly connected. Check, if the termination and bus topology are correct. Check, if the BACnet MAC address and the device instance number are correctly configured and unique within the network Restart CALEC ST II by switching the power supply off and on again. CALEC ST II runs through an initialisation process and takes over the new Baud rate. The adapted Baud rate is displayed in Device Object in the Proprietary Property 10000 CALEC ST II 9

Änderungen vorbehalten / Sous réserve de modifications Modification rights reserved / Copyright INTEGRA METERING AG info@integra-metering.com www.integra-metering.com * CALEC ST II