Development of a Robust Constant Current Source For a Current Source Inverter

Similar documents
Generalized Multilevel Current-Source PWM Inverter with No-Isolated Switching Devices

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

Analysis of Current Source PWM Inverter for Different Levels with No-Insulating Switching Device

Unipolar and Bipolar PWM Inverter

A Modified Single-Phase Quasi z source converter

Mitigation of Harmonics and Interharmonics in VSI-Fed Adjustable Speed Drives

Minimization Of Total Harmonic Distortion Using Pulse Width Modulation Technique

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Lecture Note. DC-AC PWM Inverters. Prepared by Dr. Oday A Ahmed Website:

II. L-Z SOURCE INVERTER

SIMULATION AND DESIGN OF TRANSFORMER LESS SINGLE PHASE SOLAR INVERTER

COMPARATIVE HARMONIC ANALYSIS OF VSI FED INDUCTION MOTOR DRIVE

A Pv Fed Buck Boost Converter Combining Ky And Buck Converter With Feedback

Symmetrical Multilevel Inverter with Reduced Number of switches With Level Doubling Network

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

A Predictive Control Strategy for Power Factor Correction

Multilevel Current Source Inverter Based on Inductor Cell Topology

A Battery-less Grid Connected Photovoltaic Power generation using Five-Level Common-Emitter Current-Source Inverter

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER

COMPARATIVE STUDY OF DIFFERENT TOPOLOGIES OF FIVE LEVEL INVERTER FOR HARMONICS REDUCTION

Design and Evaluation of Solar Inverter for Different Power Factor Loads

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

NPTEL

Shunt active filter algorithms for a three phase system fed to adjustable speed drive

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

International Journal of Advance Engineering and Research Development

International Journal of Advance Engineering and Research Development. Analysis of Power Factor Control Technique for CUK Converter

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Hybrid 5-level inverter fed induction motor drive

Modeling of Statcom. P.M. Sarma and Dr. S.V. Jaya Ram Kumar. Department of Electrical & Electronics Engineering GRIET, Hyderabad, India

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Investigation of Sst Pwm in qzsi

Performance Analysis of Induction Motor Drive Fed by VSI for Various Modulation Index

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Design of Single-Stage Transformer less Grid Connected Photovoltaic System

Z-SOURCE INVERTER WITH A NEW SPACE VECTOR PWM ALGORITHM FOR HIGH VOLTAGE GAIN

CHAPTER - 3 CONVENTIONAL SOURCE INVERTER FED INDUCTION MOTOR DRIVE. output voltage could be fixed or variable at a fixed or variable frequency.

Simulation Study of PWM Techniques for Voltage Source Converters

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Space Vector PWM Voltage Source Inverter Fed to Permanent Magnet Synchronous Motor

Usha Nandhini.M #1, Kaliappan.S *2, Dr. R. Rajeswari #3 #1 PG Scholar, Department of EEE, Kumaraguru College of Technology, Coimbatore, India

ISSN Vol.05,Issue.05, May-2017, Pages:

13. DC to AC Converters

THREE-LEVEL COMMON-EMITTER CURRENT-SOURCE POWER INVERTER WITH SIMPLIFIED DC CURRENT-SOURCE GENERATION

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Development of DC-AC Link Converter for Wind Generator

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

Fifteen Level Hybrid Cascaded Inverter

RECENT development of high-performance semiconductor

COMPENSATION OF VOLTAGE SAG USING LEVEL SHIFTED CARRIER PULSE WIDTH MODULATED ASYMMETRIC CASCADED MLI BASED DVR SYSTEM G.Boobalan 1 and N.

SIMULATION AND FABRICATION OF SINGLE PHASE Z-SOURCE INVERTER FOR RESISTIVE LOAD

International Journal of Advance Engineering and Research Development

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Modeling and Analysis of a Cascaded Battery-Boost Multilevel Inverter Using Different Switching Angle Arrangement Techniques

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

A Switched Boost Inverter Fed Three Phase Induction Motor Drive

VIENNA RECTIFIER FED BLDC MOTOR

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

ISSN: International Journal of Science, Engineering and Technology Research (IJSETR) Volume 1, Issue 5, November 2012

Mitigation of Power Quality Problems Using DVR in Distribution Network for Welding Load

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Three-Phase Five-Level Flying Capacitor Multilevel inverter For Harvesting Solar Power

Cascaded H-Bridge Multilevel Inverter

DESIGN OF SINGLE-STAGE BUCK BOOT CONVERTER FOR INVERTER APPLICATIONS

Design of Single Phase Pure Sine Wave Inverter for Photovoltaic Application

International Journal of Advance Research in Engineering, Science & Technology

DESIGN A D STATCOM FOR VOLTAGE HARMONIC SUPPRESSION IN DISTRIBUTION SYSTEM

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

ECEN 613. Rectifier & Inverter Circuits

Selective Harmonic Elimination (SHE) for 3-Phase Voltage Source Inverter (VSI)

An Innovative Option for Electrical Energy Conservation with a Step-Up DCto-DC Power Converter Based Grid Tie Inverter

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER

PERFORMANCE ANALYSIS OF SEVEN LEVEL INVERTER WITH SOFT SWITCHING CONVERTER FOR PHOTOVOLTAIC SYSTEM

New Approaches for Harmonic Reduction Using Cascaded H- Bridge and Level Modules

29 Level H- Bridge VSC for HVDC Application

SIMULATION, DESIGN AND CONTROL OF A MODIFIED H-BRIDGE SINGLE PHASE SEVEN LEVEL INVERTER 1 Atulkumar Verma, 2 Prof. Mrs.

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

International Journal of Advance Engineering and Research Development THREE PHASE 19 LEVEL MODULAR MULTI LEVEL INVERTER

Design of Chopper Fed Z Source PWM Inverter

Level Shifted Pulse Width Modulation in Three Phase Multilevel Inverter for Power Quality Improvement

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

ISSN Volume.06, Issue.01, January-June, 2018, Pages:

SPWM Switching Strategy for Compensation of Unbalanced and Non Linear Load Effects in Three Phase Four Wire System Using D-Statcom

Speed control of Induction Motor Using Push- Pull Converter and Three Phase SVPWM Inverter

Design and Implementation of a New PWM Based Active Impedance Power Factor Correction (AIPFC)

International Journal of Advance Engineering and Research Development THREE PHASE 19 LEVEL MODULAR MULTI LEVEL INVERTER FOR RENEWABLE ENERGY RESOURCE

Analysis of Asymmetrical Cascaded 7 Level and 9 Level Multilevel Inverter Design for Asynchronous Motor

Indirect Current Control of LCL Based Shunt Active Power Filter

SHUNT ACTIVE POWER FILTER

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Photovoltaic Grid-Connected System Based On Cascaded Quasi-Z-Source Network

When N= 2, We get nine level output current waveform And N th inductor cell ILc (i) is expressed as I. (2) Where i=1, 2, 3 N i

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

A Comparative Study between DPC and DPC-SVM Controllers Using dspace (DS1104)

Transcription:

International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn : 2278-800X, www.ijerd.com Volume 5, Issue 9 (January 2013), PP. 07-13 Development of a Robust Constant Current Source For a Current Source Inverter S.Pradeepa 1, K.Uma Rao 2, Ravishankar Deekshit 3 1,3 B.M.S.College of Enineering, Department of Electrical & Electronics Engineering, Bangalore. 2 R.V.College of Engineering, Department of Electrical & Electronics Engineering, Bangalore.. Abstract:- Current Source Inverter(CSI) has applications in the area of current protection. For CSI fed loads, when connected at a point of common coupling (PCC), the system voltage, may not always be a pure sinusoidal waveform, due to distortions created by other loads at the PCC. This paper presents two simple controllers, namely the comparator type and PI type, to derive and generate a constant current source, as input to be fed to the CSI. Results indicate that these controllers also work effectively even under distorted voltage waveform at the PCC. The controllers are validated for various source conditions and varying load conditions. Keywords:- current source inverter; point of common coupling; constant current source; power quality; distorted voltage waveform. I. INTRODUCTION High power quality and reliability of the power supply are considered to be the most important factors for the supplier and the consumer. These factors are dependent on various parameters like system voltage waveform, current waveform, frequency, nature of load connected to the system and several other issues concerned with power quality. Active filters and controllers when connected to the system, play an important role in improving the power quality of the system. Active filters are classified as current source inverters (CSI) and voltage source inverters(vsi). Both CSI and VSI have various applications, depending on the controllable parameter, which may be voltage or current. The application of a CSI as an active filter, requires a constant current source as its input. This paper proposes two strategies to generate a constant current source. Harmonics is one of the major issues in power quality. Harmonics may be present either in voltage waveforms or current waveforms, both of which bring down the power quality. These distortions in the waveforms leads to increase in Total Harmonic Distortion. THD forms a good metric to assess the effect of the harmonics present and can be used as a yardstick to decide on the derating required in equipment to account for the harmonics. The block diagram of a basic network is shown in Fig. 1, representing a system at a point of common coupling(pcc), where different loads are connected. The system voltage is expected to be a purely sinusoidal waveform, but due non-linear characteristics of certain loads connected at PCC, the system voltage waveform may not be purely sinusoidal. The Current Source Inverter requires a constant current at the DC side and the inverter output voltage is dependent on the load. In this paper, first a simple simulation model is developed to show the basic CSI operation with a Fig. 1: System Representation At A Point Of Common Coupling constant current source. For the CSI we need a constant current source at its input, irrespective of the voltage wave shape of the voltage to the rectifier, from which the current source is derived. In this paper, we have tested two types of controllers, to generate a constant current source from a non-sinusoidal ac source. The first method uses a simple comparator type controller. The second type of controller investigated is by using a PI 7

controller. The simulations are conducted and the performance of the controllers validated under both distorted ac source and varying load conditions. The controllers proposed are found to be robust and perform well under all conditions tested. II. BASIC CSI MODEL A. CSI Model using Current Source The basic single phase CSI model is shown in Fig. 2. To develop the CSI model, a constant DC current source, has been assumed as input. The simulations are carried out and the results of the load current and load voltage waveforms are shown in Fig. 3. It can be observed from the waveforms that, the conduction of the IGBT switches used for the inverter are identical to a single phase bridge operation. The amplitude of the output current remains depends on the magnitude of the input DC current.. Fig.2: Basic CSI Model Fig. 3: Load Current / Load Voltage Waveforms B. CSI Model Without Controller In a practical situation, the constant current source has to be generated from a voltage source, which may be distorted. Therefore, the constant current source generator must be capable of handling such voltage inputs also. When the system source is sinusoidal, and the load is connected at PCC through a CSI, the CSI requires a constant current source at its input. The conventional type of generating a constant current is by connecting a high inductor in series with the DC link for a CSI, in contrast to a high capacitor, connected in shunt for a VSI. The CSI model operated from a pure sinusoidal voltage source is shown in Fig. 4. The inductor is expected to keep the current a constant, and this is fed as input to the CSI. The source voltage, source current, dc link current and the load current waveforms are shown in Fig. 5. It can be observed that the dc link current is a constant. However, the CSI needs to be supplied with a constant dc current, even when it is directly connected through a distorted ac source. It is still possible to generate a constant dc link current by connecting a high series inductor in the dc link. This dc link current magnitude, varies with the load. The simulated results for a particular load, when CSI is fed from a distorted AC source are shown in Fig. 6. It can be observed from the waveforms, shown in the Fig. 5 and 6, that, under both the situations, of a sinusoidal AC source or a distorted source, at a given load condition, the DC link current can be maintained constant due to a high inductor, connected in series. The inductor connected in series has its own limitations. The variation in the magnitude of the dc link current due to the changes in the load is shown in Table 1. It can be observed that there is a wide variation in the dc link current with varying load. 8

Fig. 4: CSI Simulated Model From A Pure AC Source (d) Fig. 5: source voltage waveform source current waveform dc link current (d) load current waveform (d) Figure 6. distorted voltage source source current ) dc link current (d) inverter output current 9

Table 1: V DC and I DC without controller R L Ω AC PURE DISTORTED AC SOURCE SOURCE I DC V DC I DC V DC 5 28.62 145.6 30.77 156.3 10 14.32 145.6 15.39 156.3 15 9.549 145.6 10.27 156.3 20 7.163 145.6 7.701 156.3 III. CSI WITH CONTROLLER A. Comparator Type Controller A simple comparator type controller is added to obtain constant current under varying load conditions The CSI - source current and hence the load current amplitude remains constant even under variable load conditions while CSI output voltage varies. This is necessary when it is required to drive a constant current load. Fig. 7 shows the basic block diagram representation of a complete AC DC AC converter with comparator type controller. Fig. 8 shows the block diagram representation of a comparator type controller along with the gate pulses generated for the switches connected to rectifier bridge. In the comparator, the rectifier output current is compared with a reference constant current to generate the error signal. This error signal is compared with a carrier waveform to generate the gate pulses. Here, the pulse width is controlled by the error signal. With this simple comparator type controller, DC link current is held constant for a range of varying load conditions. Fig.7: Block Diagram Representation Of A Complete Ac Dc Ac Converter Figure 8. Comparator To Generate Gate Pulses The Simulation is carried out using the above concept and the results are verified for generation of constant current when input AC source is a pure sinusoidal waveform and by varying the load at the CSI output. The waveforms for one particular load and reference current for the controller, kept 15 amperes, is shown in Fig. 9. The simulation is repeated, when the input AC source is a distorted waveform. The waveforms for the second case is shown in Fig. 10. From the waveforms, it can be observed that,with the source voltage being either sinusoidal or non-sinusoidal, the simple comparator type controller can generate a constant current source. 10

Fig. 9: Waveforms From A Pure Ac Source with comparator Figure 10. Waveforms From A Distorted Ac Source Table 2. [With Comparator Type Controller] PURE AC DISTORTED R L Ω SOURCE AC SOURCE I DC V DC I DC V DC 5 5.592 31.14 5.545 30.97 10 5.539 58.13 5.475 57.58 15 5.45 84.13 5.4 83.43 20 5.349 109 5.321 108.5 From Table 2, it can be observed that for varying load conditions, the source current for the CSI is maintained constant and the voltage is dependent on the load variations. In this case study, the controller reference current was chosen as 5 amperes. Hence the controller maintained the DC link current at 5 amperes. 11

B. PI CONTROLLER A simple PI controller has been tried to generate a constant DC link current. A Simulink model, using PI controller is shown in Fig. 11. The simulation is carried out for input AC being a pure sine waveform and under varying load. It was observed that, the controller generates a constant current, as an input source to the CSI. The simulated waveforms for the input being pure sinusoidal AC source are shown in Fig. 12. The analysis is also done, when AC source is a distorted waveform. The waveforms for the second case is shown in Fig. 13. From the waveforms, shown in Fig. 12 and Fig. 13, it is observed that, even when the source contains harmonic distortions, the controller is able to generate a constant current magnitude, at the output of AC DC converter. Fig. 11: Simulink Model Using PI Controller Fig.12: Waveforms From A Pure Ac Source with PI controller From the waveforms, shown in Fig. 12 and Fig. 13, it is observed that, even when the source contains harmonic distortions, the controller is able to generate a constant current magnitude, at the output of AC DC converter. The controller is tested for a widely varying range of load and the results are shown in Table 3. The range of load depends upon the reference current defined for the controller. For a constant current source of 5 amperes, the simulation is carried out, using PI controller, and the readings are tabulated in Table 3. These results shown in Table 2 and 3 can be compared with the results that are shown, without a comparator. 12

Fig.13: Waveforms From A Distorted Source with PI controller Table 3. [With PI Controller] PURE AC DISTORTED R L SOURCE AC SOURCE Ω I DC V DC I DC V DC 5 5.024 28.31 5.011 28.35 10 5.024 53.07 5.011 53.01 15 5.011 77.66 5.011 77.81 20 4.984 101.8 5.015 102.5 The entire document should be in Times New Roman or Times font. Type 3 fonts must not be used. Other font types may be used if needed for special purposes. Recommended font sizes are shown in Table 1. IV. CONCLUSION In practice, for current source inverter-fed loads, the basic requirement is constant current source, which is not readily available and needs to be generated. In this paper, two controller, namely a comparator type and a PI type, have been investigated. Both the controllers exhibit superior performance as compared to the case when the controller is not used. Through appropriate design, this concept can be extended for higher power ratings. Further, the Total Harmonic Distortion of the inverter load current waveform, can be held within limits by using appropriate switching techniques for CSI, in addition to the controllers used above. REFERENCES [1]. Mustapha Raou-Moulay Tahar Lamchich Average Current Mode Control Of A Voltage Source Inverter Connected To The Grid: Application To Different Filter Cells, Journal of Electrical Engineering, VOL. 55, NO. 3-4, 2004,77{82 [2]. Middlebrook, R. D., Modeling Current Programmed Buck and Boost Regulators, IEEE Transactions on Power Electronics 4 No. 1 (1989).. [3]. Pedro Gomes Barbosa, Henrique Antonio Carvalho Braga, Márcio do Carmo Barbosa Rodrigues and Estevão Coelho Teixeira, Boost Current Multilevel Inverter And Its Application On Single-Phase Grid-Connected Photovoltaic, IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 21, NO. 4, JULY 2006. [4]. Muhammed H Rashid., Power Electronic Circuits, Devices And Applications Second Edition, Prentice Hall Of India Private Limited. 13