Nuclear Associates

Similar documents
ELECTRONIC CONTROL CONCEPTS 160 Partition Street Saugerties, NY or local phone

Nuclear Associates

Nuclear Associates

Nuclear Associates EZ CR-DIN Phantoms

Nuclear Associates

Nuclear Associates

Applications Note. Successfully using the Model 8000 NERO dental x-ray machine timer performance. max to evaluate

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

Nuclear Associates , &

Process Calibrator. TechChek 820

M. Conner Name: AP Physics C: RC Circuits Lab

Nuclear Associates &

35080M kvp Divider. Operators Manual

Exercise 1: Touch and Position Sensing

Nuclear Associates

Nuclear Associates

GFL-1000 User Manual Ground Fault Locator

Fluke199XRAY. Users Manual. Medical ScopeMeter

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

Nuclear Associates

Nuclear Associates

LANGER EMV-TECHNIK. Operating Instructions. A 100 / A 200 / A 300 Optical Fibre Probe

Nuclear Associates , , CT Head and Body Dose Phantom

ENGR 1110: Introduction to Engineering Lab 7 Pulse Width Modulation (PWM)

Nuclear Associates

M302RM OPERATING MANUAL

Frequency Calibrator with Totalizer

Frequency Calibrator with Totalizer

SERVICE & QUALITY CONTROL KITS

Nuclear Associates

LPB OMNI Broadcast Transmitter Installation Procedure Checklist

Touchless Control: Hand Motion Triggered Light Timer

2.7 GHz FREQUENCY COUNTER with TCXO

EScope Pro (P/N ESO1000) (Patent Pending)

CBCT TM CIRCUIT BREAKER COIL TESTER

NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE

Model 7000 Low Noise Differential Preamplifier

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

INSTRUCTION MANUAL MODEL 4010A. 2 MHz FUNCTION GENERATOR MANUAL DE INSTRUCCIONES MODELO 4010A. 2MHz GENERADOR DE FUNCIONES

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE

Oscilloscope Probes and Accessories

Model 4007DDS. 7 MHz Sweep Function Generator

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

TRACEABLE RADIO-SIGNAL REMOTE THERMOMETER INSTRUCTIONS

USB-UT350(T) Portable Ultrasonic Pulser/Receiver and Analog to Digital Converter. User s Guide

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

Thornwood Drive Operating Manual: Two-SCR General Purpose Gate Firing Board FCRO2100 Revision H

Turbine Temperature Test Set

DL102 Counter Loop Amplifier

Mobile Activation Case

MODULE 06 POWER SUPPLIES

TNT DoseMate Dosimeter Detector

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

Dawson DDM190. Digital Multimeter User s Manual

Construction of a high-voltage Buck-Boost capacitor charger. Transformer and logic

BTM Series Pulsed RF Power Amplifier Modules. Application Note

AM48 XT & AM48e XT Family of Products

Fluke 192/196/199. MS 190 and MA 190. Users Manual Supplement

EECS 318 Electronics Lab Laboratory #2 Electronic Test Equipment

Experiment #2 Half Wave Rectifier

TIA-525 Optical/Electrical Converter Operating Instructions

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

S D 1 Operating Instructions

41P Portable Calibrator User Manual

PIEZO FILM LAB AMPLIFIER

Single-Phase Grid-Tied Inverter (PWM Rectifier/Inverter)

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

Patriot Test Station Monitor

Experiment 1: Instrument Familiarization (8/28/06)

ECE 404 e-notes...copyright 2008 by Gregory M. Wierzba. All rights reserved...fall 2008.

Technical data ESA614 Electrical Safety Analyzer

56-6XX CLEAR-Pb Mobile Barriers

Model 9305 Fast Preamplifier Operating and Service Manual

On-Line Students Analog Discovery 2: Arbitrary Waveform Generator (AWG). Two channel oscilloscope

- Wiring Brochure Universal Reset Module 423e

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Series 1. Remote. Multiple Mode Remote Controlled Electro Stimulation Control Unit. User Manual

DU3 Ultrasonic Vehicle Detector

ORTEC Experiment 1. Introduction to Electronic Signal Analysis in Nuclear Radiation Measurements. Equipment Required: Purpose. Electronic Circuits

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

Introduction to High-Speed Power Switching

PHY 112L Activity 2 Electronics Primer

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

Nuclear Associates Precision Photometer

Introduction to oscilloscope. and time dependent circuits

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Synthesized Transmitter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Model 533 Dual Sum and Invert Amplifier Operating and Service Manual

ELECTROSURGICAL UNIT ANALYZER

Flow Detection MDS Integral or Remote Housing. Installation and Operating Instructions

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

EE-110 Introduction to Engineering & Laboratory Experience Saeid Rahimi, Ph.D. Lab Timer: Blinking LED Lights and Pulse Generator

Exercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE

Lab 1: Introduction to Electronics Measurement Equipment

Model 113 Scintillation Preamplifier Operating and Service Manual

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

CONNECTING THE PROBE TO THE TEST INSTRUMENT

AT-4000 Advanced Tracer User s Manual

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Transcription:

Nuclear Associates 07-453 Digital X-Ray Pulse Counter/Timer Operators Manual February 2005 Manual No. 07-453-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com/rms

Table of Contents Section 1: General Information... 1-1 1.1 Introduction... 1-1 1.2 Description... 1-1 1.3 Specifications... 1-2 1.4 Battery Replacement... 1-2 Section 2: Operation... 2-1 2.1 General Instructions... 2-1 2.2 Oscilloscope Output... 2-2 i

(Blank Page)

General Information Introduction 1 Section 1 General Information 1.1 Introduction The Model 07-453 Digital Pulse Counter measures exposure time for a wide variety of x-ray generators. For half-wave x-rays such as dental machines, the instrument is always used in Pulse mode. The instrument will display the number of pulses. For DC or 3-phase x-rays, the 07-453 is always used in Millisec mode. After an exposure, the instrument will indicate the exposure time in milliseconds. For fullwave x-rays, the operator may need to try both modes. For most full-wave x-rays, especially at low power settings, the 07-453 should be used in Pulse mode. The unit will indicate the number of x-ray pulses. Many full-wave x-ray waveforms have a DC component. In other words, the x-ray output does not drop to zero between pulses. When this occurs, the 07-453 will read 1(one) when used in Pulse mode. The output of a DC x-ray is actually one pulse, so the instrument is reading correctly. To measure the exposure time, simply switch the instrument to Millisec and the instrument will time the x-ray in milliseconds. 1.2 Description NOTE It is important that the user be thoroughly familiar with the contents of this manual before performing any tests on radiation-generating equipment. It is also imperative that the user be thoroughly qualified, and familiar with safety precautions and other practices relating to radiation generators. The Digital X-Ray Pulse Counter/Timer is used to measure the duration of radiation output produced by x- ray generators. This solid-state, digital instrument is designed specifically to aid service personnel in assessing the performance of radiation generator timing controls. The instrument is a noninvasive instrument, which samples the radiation beam of x-rays. The Digital X-Ray Pulse Counter/Timer can be used as follows: 1. To count the number of x-ray pulses produced by half-wave and full-wave rectified machines; typically 60 pulses per second for half-wave rectified machines or 120 pulses per second for fullwave. Dental x-ray machines are typically half-wave rectified. 2. To measure the length of radiation output when the x-ray output is steady-state such that pulsing does not exist. X-rays that generate steady outputs include 3-phase AC medical x-ray machines, capacitor discharge x-ray machines and DC operated x-rays. 3. To measure the on time or relay contact closure time by counting the number of pulses of AC line voltage (65 to 130 VAC) via the front panel input jacks and test leads. The Digital X-Ray Pulse Counter/Timer replaces not only mechanical impulse counters, but also other electronic counters. Its small hand-held size allows it to conveniently fit in a small tool box/jacket pocket. There is no Reset button. The Digital X-Ray Pulse Counter/Timer automatically resets at the beginning of each exposure, holding the reading until the next exposure. 1-1

Nuclear Associates 07-453 Operators Manual The most convenient way of using the Digital X-Ray Pulse Counter/Timer is to place it directly under the x-ray head. Step back, take the exposure and then read the exposure time in pulses or milliseconds. An optional remote sensor is also available to allow use of the instrument at distances of up to 12 ft away from the x-ray. 1.3 Specifications Accuracy Sensitivity Range Display Power Battery Life AC Input Jacks Controls/Indicators Connections Dimensions Weight Accessories Optional Accessories AC Input: +/- 1 count DC Input: 2% or +/- 1 count X-ray Detection: +/- 1 count AC Input: 65 VAC minimum X-ray Input: 50 kvp, 5 ma at 2.0 in from top surface of case, pointed to target on case 9999 pulses 9999 milliseconds 0.4 in liquid crystal 9 V battery; alkaline or equivalent 24 hours continuous; typically 6 months of normal use 130 V AC maximum 65 V AC minimum Input circuit not affected by reversed polarity 3-position switch: Pulse, Off, Milliseconds 4-digit liquid crystal display: 0.4 character Low battery indicator: Low Batt appears in display when battery voltage reaches 4.8 V ± 0.5 V Power-On: LED (green) Oscilloscope output None required for direct exposure measurement 3.15 x 5.8 x 1.6 in (80 x 147 x 40 mm) 0.5 lbs/0.21 kg AC test leads with pluggable alligator clips Remote X-Ray Sensor (Model 07-453-2000) Carrying Case (Model 89-453) Oscilloscope Leads (Model 88-453) 1.4 Battery Replacement The Digital X-Ray Pulse Counter/Timer is supplied with one 9 V alkaline battery. Replace the battery when the Lo Batt indicator shows in the display. Long life alkaline batteries are available from Fluke Biomedical. Any standard 9 V alkaline battery can be used in the Digital X-Ray Pulse Counter/Timer. To replace the battery, slide open the battery compartment on the bottom of the case. Remove the old battery, and install the new battery. 1-2

Operation General Instructions 2 Section 2 Operation 2.1 General Instructions Switch Settings The front panel selector/toggle switch on the Digital X-Ray Pulse Counter/Timer has three positions: OFF, PULSE and MILLISEC. The switch is OFF when in the center position. OFF All power to the instrument is disconnected in the OFF position. Set the switch to OFF when not in use, to conserve battery life. The center position is OFF. PULSE When the switch is moved to the PULSE position, the instrument will be used for measuring output pulses from half-wave or full-wave rectified machines as well as AC line voltage pulses. Normally, each full second of exposure will produce 60 pulses. An exposure of 2/10 second will read 12, for example. MILLISEC With the switch in the MILLISEC position, the instrument will measure the length of time that a DC or 3- phase AC x-ray is on. The display reading will be in milliseconds; i.e., an exposure of 1 second will read 1000; an exposure of 2/10 second will read 200. Connections When reading directly from an x-ray head, no connections are made to the instrument. Point the x-ray head at the target area of the instrument (near the lower left side of the instrument). Take an exposure and read the time on the display in pulses or milliseconds. Oscilloscope Output A jack labeled scope located on the left side of the instrument is the oscilloscope output. It allows the user to connect the instrument to an oscilloscope, so that x-ray waveform can be observed. This connector takes a standard 2.5 mm mono phone plug. Remote Sensor To use the Remote Sensor (optional), connect the plug at the end of the remote sensor cable into the jack labeled remote located on the left side of the Digital X-Ray Pulse Counter/Timer. Point the x-ray head at the target on the Remote Sensor. Stretch the cable out and use as described above. 2-1

Nuclear Associates 07-453 Operators Manual AC Input Connect the two test leads to the two input jacks on the front of the instrument. Since the instrument counts AC pulses, the AC line must be switched by the relay that is in the timer under test. The circuit for AC inputs is completely isolated from the rest of the instrument. No damage to the instrument will occur if the probes are reversed. However, to obtain the best accuracy, the + (red) should be connected to the high side of the line, and the black or - probe should be connected to the low side of the line. 2.2 Oscilloscope Output The Digital X-Ray Pulse Counter/Timer can be, and usually is, used without an oscilloscope, but the scope output feature enables technical analysis of the x-ray output. X-ray generators often have characteristics such as gradual rise times, variations in amplitude, noise, capacitive filtering, and extended decay times. Problems with x-rays can often be diagnosed by observing the output waveform of an x-ray with an oscilloscope. Plug in a standard 2.5 mm mono phone plug into the jack and attach the leads of the scope probe to the phone plug terminals. Set the vertical sensitivity of the scope to 1 V per cm. The scope waveform will be an amplified version of the actual output of the x-ray detector. A cable with a phone plug and a BNC connector for a scope is available from Fluke Biomedical (Model 88-453). The 2.5 mm mono phone plug is available from many vendors including Mouser Electronics, (P/N 177PP053). The Remote Sensor available from Fluke Biomedical (Model 07-453-2000) is particularly useful when observing the x-ray output using an oscilloscope. 2-2

(Blank Page)

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com/rms